1.Transcatheter aortic valve replacement for aortic regurgitation complicated by Takayasu arteritis: A case report
Jianbin GAO ; Jian LI ; Yu YANG ; Mier MA ; Kairui YANG ; Wei LUO ; Ning WANG ; Da ZHU ; Wenbin OUYANG ; Xiangbin PAN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2026;33(01):163-166
Patients with Takayasu arteritis combined with aortic valve disease often have a poor prognosis following surgical valve replacement, frequently encountering complications such as perivalvular leakage, valve detachment, and anastomotic aneurysm. This article presents a high-risk case wherein severe aortic valve insufficiency associated with Takayasu arteritis was successfully managed through transcatheter aortic valve implantation via the transapical approach. The patient had satisfactory valve function with no complications observed during the six-month postoperative follow-up. This case provides a minimally invasive and feasible alternative for the clinical management of such high-risk patients.
2.Experimental study on the ultrasound visibility of a novel interventional catheter and delivery system: In vitro and animal experiments
Ziping LI ; Wenbin OUYANG ; Zizheng LIU ; Ning ZHOU ; Jie DONG ; Shouzheng WANG ; Xiangbin PAN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2026;33(05):784-790
Objective To assess the echogenicity of the ultrasound-guided catheter and its associated delivery system. Methods The study consisted of in vitro characterization experiments and animal studies. In the in vitro phase, the acoustic and mechanical properties of the ultrasound-guided catheter were compared with those of the traditional MPA2 catheter, including parameters such as echo intensity, recognizability, and angle dependence. In the animal experiments, a ventricular septal defect (VSD) model was established in miniature pigs to compare the procedural performance of the ultrasound-guided delivery system versus the conventional system. Evaluation indicators included the time required for the system to cross the VSD, the detection rate of the system within the right ventricle, and the occurrence of intraoperative complications. Results The ultrasound-guided catheter demonstrated a significantly higher mean echo intensity than the MPA2 catheter [(237.3±1.8) dB vs. (190.9±13.1) dB, P<0.001] and a markedly improved recognizability rate (82.3%±5.6% vs. 26.7%±3.2%, P<0.001), along with better angle independence and image quality. In animal experiments, the ultrasound-guided delivery system significantly reduced the time required to cross the VSD [(18.5±5.7) min vs. (30.3±4.5) min, P<0.001] and substantially increased the detection rate within the right ventricle (100.0% vs. 30.0%). No severe complications occurred in any experimental animal. Conclusion The ultrasound-guided catheter and its corresponding delivery system exhibite superior ultrasound visibility and operational performance in both in vitro and animal experiments, indicating strong potential for clinical application.
3.Biomechanical characteristics of walking in patients with idiopathic scoliosis:cross-sectional analysis of three-dimensional motion capture
Yanyun GOU ; Meijin HOU ; Zheng JIANG ; Shaoqing CHEN ; Xiang CHEN ; Yuzhan GAO ; Xiangbin WANG
Chinese Journal of Tissue Engineering Research 2025;29(3):471-477
BACKGROUND:The biomechanical analysis of scoliosis cases is limited,with only independent analysis focusing on the spine or lower limbs,thus lacking a comprehensive evaluation of the multidimensional body.As a result,it becomes challenging to reflect the movement relationship between the trunk and lower limbs during daily activities,which hinders comprehensive clinical treatment guidance. OBJECTIVE:To explore the relationship between different segments of the spine and the kinematics/kinetics of the lower limbs during gait activities by measuring spinal kinematics in scoliosis patients,to provide a comprehensive and multi-level assessment of the biomechanical differences between scoliosis patients and the normal population,consequently offering evidence-based guidance for the prevention and treatment of scoliosis. METHODS:A cross-sectional study was conducted from July 2020 to June 2021 at the Rehabilitation Hospital Affiliated to Fujian University of Traditional Chinese Medicine in Fuzhou University City.A total of 28 scoliosis patients and 28 normal individuals in the same age group were included.Three-dimensional motion capture system was used to capture gait kinematic data at a sampling frequency of 100 Hz.Two force plates(AMTI 400600,sampling frequency 1 500 Hz)were embedded in a 10-meter-long 2.4-meter-wide level ground walkway(with an effective data collection length of 4 m)to collect kinetic data.The differences in spatial-temporal parameters,kinematics,and kinetics of gait between the two groups were compared.Immediately after inclusion,all subjects underwent full spinal X-ray measurements to compare the differences between the scoliosis and normal groups. RESULTS AND CONCLUSION:(1)Patients with scoliosis exhibited reduced relative rotational range of motion between the shoulder and trunk,as well as between the thorax and pelvis,compared to the normal group(P<0.05).However,the rotational range of motion in the pelvis was larger in patients with scoliosis compared to the normal group(P<0.05).(2)Patients with scoliosis showed decreased range of motion in the hip and knee joints,as well as reduced peak torque in hip joint flexion and extension,and lower peak values of ground reaction forces in the concave and convex directions,in comparison to the normal group(P<0.05).(3)Patients with scoliosis demonstrated greater asymmetry indices in knee joint range of motion,relative rotational range of motion between the shoulder and trunk,and between the thorax and pelvis,when compared to the normal group(P<0.05).(4)These findings illustrate a rigid movement pattern among the shoulder,thorax,and pelvis in patients with scoliosis during level walking.There is a reduction in range of motion in the hip and knee joints,as well as decreased peak torque values in hip joint flexion and extension,and ground reaction forces in the concave and convex directions.These characteristics can serve as foundational elements for assessing rehabilitation and developing treatment plans.
4.Novel X-Clip transcatheter edge-to-edge repair system for treating severe functional mitral regurgitation: The first case report
Jiaqi DAI ; Da ZHU ; Shouzheng WANG ; Xiangbin PAN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(04):567-570
For patients with moderate-to-severe functional mitral regurgitation (FMR) who continue to experience heart failure symptoms despite optimized medical and device therapy, transcatheter mitral valve edge-to-edge repair (TEER) is increasingly becoming a reliable treatment option. With the continuous research and development and improvement of TEER-related devices, there are currently dozens of domestically developed TEER devices undergoing clinical trials in China. In this study, we report the first case of a patient with severe FMR treated with the X-Clip® TEER system. The patient, a 60-year-old male, suffered FMR attributed to dilated cardiomyopathy. Preoperative transthoracic echocardiography showed severe mitral regurgitation (4+). He underwent percutaneous repair using the X-Clip® system, and immediate postoperative ultrasound showed mild mitral regurgitation. At the 1-month follow-up, the patient’s symptoms and New York Heart Association (NYHA) functional class improved, and a follow-up transthoracic echocardiogram showed mild mitral regurgitation (1+).
5.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
6.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
7.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
8.Csde1 Mediates Neurogenesis via Post-transcriptional Regulation of the Cell Cycle.
Xiangbin JIA ; Wenqi XIE ; Bing DU ; Mei HE ; Jia CHEN ; Meilin CHEN ; Ge ZHANG ; Ke WANG ; Wanjing XU ; Yuxin LIAO ; Senwei TAN ; Yongqing LYU ; Bin YU ; Zihang ZHENG ; Xiaoyue SUN ; Yang LIAO ; Zhengmao HU ; Ling YUAN ; Jieqiong TAN ; Kun XIA ; Hui GUO
Neuroscience Bulletin 2025;41(11):1977-1990
Loss-of-function variants in CSDE1 have been strongly linked to neuropsychiatric disorders, yet the precise role of CSDE1 in neurogenesis remains elusive. In this study, we demonstrate that knockout of Csde1 during cortical development in mice results in impaired neural progenitor proliferation, leading to abnormal cortical lamination and embryonic lethality. Transcriptomic analysis revealed that Csde1 upregulates the transcription of genes involved in the cell cycle network. Applying a dual thymidine-labelling approach, we further revealed prolonged cell cycle durations of neuronal progenitors in Csde1-knockout mice, with a notable extension of the G1 phase. Intersection with CLIP-seq data demonstrated that Csde1 binds to the 3' untranslated region (UTR) of mRNA transcripts encoding cell cycle genes. Particularly, we uncovered that Csde1 directly binds to the 3' UTR of mRNA transcripts encoding Cdk6, a pivotal gene in regulating the transition from the G1 to S phases of the cell cycle, thereby maintaining its stability. Collectively, this study elucidates Csde1 as a novel regulator of Cdk6, sheds new light on its critical roles in orchestrating brain development, and underscores how mutations in Csde1 may contribute to the pathogenesis of neuropsychiatric disorders.
Animals
;
Neurogenesis/genetics*
;
Cell Cycle/genetics*
;
Mice, Knockout
;
Mice
;
Neural Stem Cells/metabolism*
;
DNA-Binding Proteins/metabolism*
;
Cyclin-Dependent Kinase 6/genetics*
;
Cell Proliferation
;
3' Untranslated Regions
;
Cerebral Cortex/embryology*
;
RNA-Binding Proteins
;
Mice, Inbred C57BL
9.One-year outcomes of a novel domestic transcatheter aortic valve system in severe aortic stenosis: a multicenter cohort study
Yuehuan LI ; Jiawei ZHOU ; Lai WEI ; Yingqiang GUO ; Liang MA ; Huiming GUO ; Xiangbin PAN ; Dongjin WANG ; Fanyan LUO ; Jue WANG ; Minxin WEI ; Deguang FENG ; Yingbin XIAO ; Liming LIU ; Jian′an WANG ; Jiangang WANG ; Haibo ZHANG
Chinese Journal of Surgery 2025;63(11):1052-1058
Objective:To examine the safety and effectiveness of a novel domestic transcatheter aortic valve system in addressing severe aortic valve stenosis.Methods:This prospective, multicenter, single-arm target-value clinical trial enrolled patients with severe aortic stenosis meeting inclusion criteria from 13 Chinese centers between July 2021 and April 2022. The primary endpoint was all-cause mortality at 1-year post-procedure. Secondary endpoints included safety outcomes (30-day all-cause mortality, 1-year major adverse cardiovascular events, device success) and efficacy parameters (transvalvular pressure gradient, paravalvular leak severity, New York Heart Association(NYHA)class improvement, and quality of life). Survival analysis was performed using the Kaplan-Meier analysis.Results:The study included 134 patients, 85 males and 49 females, with an age of (73.6±5.6)years (range: 65.1 to 91.8 years). Bicuspid aortic valve morphology was present in 59.7% (80/134). Device success rate was 99.3%, with one case converted to open surgery due to coronary obstruction. All-cause mortality was 0.8% (95% CI: 0.1% to 5.3%) at both 30-day and 1-year follow-up, significantly lower than the 25% target value ( P<0.01). Permanent pacemaker implantation rates remained 2.2% (3/134) at both timepoints. Stroke incidence was 0.7% (1/134) at 30 days and 1.5% (2/134) at 1 year. Myocardial infarction rates were 0.7% (1/134) at both intervals. The postoperative transvalvular pressure gradient of the aortic valve was (6.6±3.1) mmHg(1 mmHg=0.133 kPa) (range: 4 to 8 mmHg). Among the patients, 32 cases (23.9%) had mild paravalvular leakage, 4 cases (3.0%) had moderate paravalvular leakage, and no severe paravalvular leakage was observed. NYHA class Ⅰ and Ⅱ patients increased from 18.7% preoperatively to 99.3% postoperatively. Conclusion:The novel domestic transcatheter aortic valve system demonstrates satisfactory 1-year safety and efficacy outcomes in treating severe aortic stenosis.
10.Animal study results of a novel designed transcatheter mitral valve replacement system
Da ZHU ; Shouzheng WANG ; Jianbin GAO ; Zhiling LUO ; Ke YANG ; Chunmei XIE ; Pengxu KONG ; Shuyi FENG ; Hong JIANG ; Xiangbin PAN
Chinese Journal of Cardiology 2025;53(3):287-292
Objective:To preliminarily assess the biocompatibility and durability of the TruDelta TM transcatheter mitral valve replacement (TMVR) system. Method:Six adult sheep were divided into 3 groups based on the duration of follow-up: 30 days ( n=1), 90 days ( n=3) and 180 days ( n=2). The TruDelta TM TMVR system was implanted through a transapical approach under transesophageal echocardiographic guidance. The operability of the TMVR system was evaluated using an instrument performance evaluation scale (consisting of 39 items), with scores ranging from 1 (worst) to 10 (best) assigned by the operator. Echocardiography was conducted preoperatively, immediately after surgery, and at 30, 90, and 180 days post-implantation. At the last follow-up time point, the intervention mitral valve membrane and major organs were dissected for observation. The artificial valves were taken for hematoxylin eosin (HE) staining and observed under a scanning electron microscope. Result:All six procedures were successfully completed using 29S size TruDelta TM TMVR device. At the final follow-up, echocardiogram demonstrated good valve function without obvious paravalvular leakage, with a transvalvular gradient of (7.8±3.2) mmHg (1 mmHg=0.133 kPa) and a mitral valve orifice area of (1.8±0.2) cm 2. Autopsy findings revealed no structural valve failure and almost complete endothelialization (>75%) with 90 to 180 days. Both HE staining and scanning electron microscopy confirmed optimal endothelialization of the valve stent. Conclusion:The preclinical animal study indicates that the TruDelta TM device exhibits favorable biocompatibility and durability.

Result Analysis
Print
Save
E-mail