1.Transcatheter aortic valve replacement for aortic regurgitation complicated by Takayasu arteritis: A case report
Jianbin GAO ; Jian LI ; Yu YANG ; Mier MA ; Kairui YANG ; Wei LUO ; Ning WANG ; Da ZHU ; Wenbin OUYANG ; Xiangbin PAN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2026;33(01):163-166
Patients with Takayasu arteritis combined with aortic valve disease often have a poor prognosis following surgical valve replacement, frequently encountering complications such as perivalvular leakage, valve detachment, and anastomotic aneurysm. This article presents a high-risk case wherein severe aortic valve insufficiency associated with Takayasu arteritis was successfully managed through transcatheter aortic valve implantation via the transapical approach. The patient had satisfactory valve function with no complications observed during the six-month postoperative follow-up. This case provides a minimally invasive and feasible alternative for the clinical management of such high-risk patients.
2.Experimental study on the ultrasound visibility of a novel interventional catheter and delivery system: In vitro and animal experiments
Ziping LI ; Wenbin OUYANG ; Zizheng LIU ; Ning ZHOU ; Jie DONG ; Shouzheng WANG ; Xiangbin PAN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2026;33(05):784-790
Objective To assess the echogenicity of the ultrasound-guided catheter and its associated delivery system. Methods The study consisted of in vitro characterization experiments and animal studies. In the in vitro phase, the acoustic and mechanical properties of the ultrasound-guided catheter were compared with those of the traditional MPA2 catheter, including parameters such as echo intensity, recognizability, and angle dependence. In the animal experiments, a ventricular septal defect (VSD) model was established in miniature pigs to compare the procedural performance of the ultrasound-guided delivery system versus the conventional system. Evaluation indicators included the time required for the system to cross the VSD, the detection rate of the system within the right ventricle, and the occurrence of intraoperative complications. Results The ultrasound-guided catheter demonstrated a significantly higher mean echo intensity than the MPA2 catheter [(237.3±1.8) dB vs. (190.9±13.1) dB, P<0.001] and a markedly improved recognizability rate (82.3%±5.6% vs. 26.7%±3.2%, P<0.001), along with better angle independence and image quality. In animal experiments, the ultrasound-guided delivery system significantly reduced the time required to cross the VSD [(18.5±5.7) min vs. (30.3±4.5) min, P<0.001] and substantially increased the detection rate within the right ventricle (100.0% vs. 30.0%). No severe complications occurred in any experimental animal. Conclusion The ultrasound-guided catheter and its corresponding delivery system exhibite superior ultrasound visibility and operational performance in both in vitro and animal experiments, indicating strong potential for clinical application.
3.Research progress on artificial intelligence application in the perioperative period of cardiovascular surgery
Hong JIANG ; Zeye LIU ; Xiangbin PAN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(01):54-59
With the advancement and development of computer technology, the medical decision-making system based on artificial intelligence (AI) has been widely applied in clinical practice. In the perioperative period of cardiovascular surgery, AI can be applied to preoperative diagnosis, intraoperative, and postoperative risk management. This article introduces the application and development of AI during the perioperative period of cardiovascular surgery, including preoperative auxiliary diagnosis, intraoperative risk management, postoperative management, and full process auxiliary decision-making management. At the same time, it explores the challenges and limitations of the application of AI and looks forward to the future development direction.
4.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
5.Transcatheter Closure of Patent Ductus Arteriosus With a Fully Biodegradable Occluder Under the Sole Guidance of Transthoracic Echocardiography:a Case Report
Zizheng LIU ; Ying'ao ZHAO ; Jianing CUI ; Ning ZHOU ; Jing DONG ; Fengwen ZHANG ; Wenbin OUYANG ; Xiangbin PAN
Chinese Circulation Journal 2025;40(9):919-921
This article presents the first reported successful case of patent ductus arteriosus closure using a fully biodegradable occluder under the sole guidance of transthoracic echocardiography.Compared to traditional methods that require radiation and metal occluders,this technique,which combines echocardiography guidance with biodegradable devices,reduces iatrogenic injury and procedural risks,demonstrating favorable clinical outcomes.
6.Report of Successful Percutaneous Closure of Patent Foramen Ovale Using Fully Biodegradable Occluder Solely under Echocardiography Guidance
Yiming YAN ; Ziping LI ; Fengwen ZHANG ; Hongmei SU ; Ying'ao ZHAO ; Jing DONG ; Guangzhi ZHAO ; Wenbin OUYANG ; Xiangbin PAN
Chinese Circulation Journal 2025;40(10):1033-1035
This article reports the first case of percutaneous closure of patent foramen ovale(PFO)using a biodegradable occluder under echocardiography guidance.The patient is a 43-year-old female diagnosed with PFO-related stroke.The procedure was successfully completed under echocardiography guidance without complications.During the 48-month follow-up period,the patient experienced no recurrent strokes,and the occluder was fully degraded.
7.Feasibility Exploration of Zero-ray Radiofrequency Catheter Ablation of Atrial Fibrillation Guided by Transthoracic Echocardiography Combined With Three-dimensional Mapping System
Tianjie FENG ; Guangzhi ZHAO ; Jing DONG ; Cheng WANG ; Fengwen ZHANG ; Shouzheng WANG ; Jun LIU ; Guodong NIU ; Min TANG ; Fujian DUAN ; Xiangbin PAN
Chinese Circulation Journal 2025;40(4):374-379
Objectives:To explore the feasibility of zero-ray radiofrequency catheter ablation for paroxymal atrial fibrillation under the guidance of transthoracic echocardiography combined with three-dimensional mapping system.Methods:This is a single-center prospective observational study.A total of 12 patients with paroxysmal atrial fibrillation who underwent radiofrequency catheter ablation in Fuwai Hospital,Chinese Academy of Medical Sciences from June 1,2024 to September 30,2024 were included.All patients underwent successful percutaneous puncture,atrial septal puncture under the guidance of transthoracic echocardiography,and all patients underwent left atrial modeling and discharge ablation under the guidance of transthoracic echocardiography combined with three-dimensional mapping system.The disappearance of pulmonary vein potential was confirmed after the ablation operation and as the ablation endpoint and successful ablation marker.The operation results and 1-month and 3-month follow-up results of the patients were observed.Results:There were 12 patients with paroxysmal atrial fibrillation,9 males and 3 females,aged(56.8±11.2)years,with a history of paroxysmal atrial fibrillation(4.2±2.3)years.The mean left atrial diameter was(36.5±2.5)mm,the left ventricular end-diastolic diameter was(47.8±4.1)mm,and the left ventricular ejection fraction was 55%-65%.The mean overall operation time was(102.25±14.51)min,the ultrasound operation time was(29.58±6.23)min,and the catheter operation time was(33.08±4.10)min.All patients completed circumferential pulmonary vein isolation without intraoperative complications.The hospitalization time was 2-6 days.At the 1-month follow-up after ablation,all patients showed sinus rhythm on 24-hour ambulatory electrocardiogram,and 2 patients had occasional atrial premature contractions without recurrence of atrial fibrillation.At the 3-month follow-up,two patients had occasional premature atrial contractions,and no recurrence of atrial fibrillation was recorded on the electrocardiogram of all patients.Conclusions:It is feasible to complete radiofrequency catheter ablation of paroxysmal atrial fibrillation under the guidance of transthoracic echocardiography combined with three-dimensional mapping system.
8.Echocardiography-guided Transcatheter Aortic Valve Replacement After Aortic Bioprosthetic Failure:a Case Report
Guangzhi ZHAO ; Shouzheng WANG ; Xiangbin PAN
Chinese Circulation Journal 2025;40(3):290-292
This article reports a case of transcatheter aortic valve replacement guided by echocardiography only for the treatment of aortic valve bioprosthesis failure.The patient developed bioprosthesis stenosis eight years after surgical bioprosthetic aortic valve replacement and underwent successful transcatheter aortic valve-in-valve replacement under echocardiography guidance.This offers a new treatment option for valve replacement after bioprosthetic valve failure under echocardiography guidance,and demonstrates the feasibility of echocardiography-guided interventional transcatheter valve-in-valve replacement.Also,this report discusses the technique details in valve positioning,reducing the risk of complications and improving prognosis.
9.Feasibility Exploration of Zero-ray Radiofrequency Catheter Ablation of Atrial Fibrillation Guided by Transthoracic Echocardiography Combined With Three-dimensional Mapping System
Tianjie FENG ; Guangzhi ZHAO ; Jing DONG ; Cheng WANG ; Fengwen ZHANG ; Shouzheng WANG ; Jun LIU ; Guodong NIU ; Min TANG ; Fujian DUAN ; Xiangbin PAN
Chinese Circulation Journal 2025;40(4):374-379
Objectives:To explore the feasibility of zero-ray radiofrequency catheter ablation for paroxymal atrial fibrillation under the guidance of transthoracic echocardiography combined with three-dimensional mapping system.Methods:This is a single-center prospective observational study.A total of 12 patients with paroxysmal atrial fibrillation who underwent radiofrequency catheter ablation in Fuwai Hospital,Chinese Academy of Medical Sciences from June 1,2024 to September 30,2024 were included.All patients underwent successful percutaneous puncture,atrial septal puncture under the guidance of transthoracic echocardiography,and all patients underwent left atrial modeling and discharge ablation under the guidance of transthoracic echocardiography combined with three-dimensional mapping system.The disappearance of pulmonary vein potential was confirmed after the ablation operation and as the ablation endpoint and successful ablation marker.The operation results and 1-month and 3-month follow-up results of the patients were observed.Results:There were 12 patients with paroxysmal atrial fibrillation,9 males and 3 females,aged(56.8±11.2)years,with a history of paroxysmal atrial fibrillation(4.2±2.3)years.The mean left atrial diameter was(36.5±2.5)mm,the left ventricular end-diastolic diameter was(47.8±4.1)mm,and the left ventricular ejection fraction was 55%-65%.The mean overall operation time was(102.25±14.51)min,the ultrasound operation time was(29.58±6.23)min,and the catheter operation time was(33.08±4.10)min.All patients completed circumferential pulmonary vein isolation without intraoperative complications.The hospitalization time was 2-6 days.At the 1-month follow-up after ablation,all patients showed sinus rhythm on 24-hour ambulatory electrocardiogram,and 2 patients had occasional atrial premature contractions without recurrence of atrial fibrillation.At the 3-month follow-up,two patients had occasional premature atrial contractions,and no recurrence of atrial fibrillation was recorded on the electrocardiogram of all patients.Conclusions:It is feasible to complete radiofrequency catheter ablation of paroxysmal atrial fibrillation under the guidance of transthoracic echocardiography combined with three-dimensional mapping system.
10.Two Cases of Transcatheter Aortic Valve Replacement Guided by Echocardiography Alone for Severe Aortic Stenosis
Shouzheng WANG ; Guangzhi ZHAO ; Xiaopeng HU ; Hao SHI ; Bo PENG ; Xu WANG ; Xiangbin PAN
Chinese Circulation Journal 2025;40(3):284-289
Transcatheter aortic valve replacement(TAVR)has become an important therapeutic approach for severe aortic stenosis.However,complications associated with TAVR cannot be overlooked,among which contrast agents induced acute kidney injury(AKI)is a common complication.To explore methods to reduce the occurrence of AKI,this article reports two cases of successful treatment of severe aortic stenosis by TAVR under pure echocardiographic guidance,both of whom were elderly women aged 75 and 69,respectively,and both were implanted with a Evolute Pro 26 mm valve.Postoperative echocardiography showed good valve positioning and function.

Result Analysis