1.Transcatheter aortic valve replacement for aortic regurgitation complicated by Takayasu arteritis: A case report
Jianbin GAO ; Jian LI ; Yu YANG ; Mier MA ; Kairui YANG ; Wei LUO ; Ning WANG ; Da ZHU ; Wenbin OUYANG ; Xiangbin PAN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2026;33(01):163-166
Patients with Takayasu arteritis combined with aortic valve disease often have a poor prognosis following surgical valve replacement, frequently encountering complications such as perivalvular leakage, valve detachment, and anastomotic aneurysm. This article presents a high-risk case wherein severe aortic valve insufficiency associated with Takayasu arteritis was successfully managed through transcatheter aortic valve implantation via the transapical approach. The patient had satisfactory valve function with no complications observed during the six-month postoperative follow-up. This case provides a minimally invasive and feasible alternative for the clinical management of such high-risk patients.
2.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
3.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
4.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
5.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
6.Risks, mechanisms, and prevention strategies for cerebrovascular diseases in lunar astronauts under deep.
Lei TANG ; Qiaoling TANG ; Ye LI ; Li WANG ; Feng ZHANG ; Xiangbin ZHANG ; Ran LIU ; Le ZHANG
Journal of Central South University(Medical Sciences) 2025;50(8):1337-1345
As human deep space exploration enters a practical phase, ensuring astronaut health and safety has become a critical determinant of mission success. The cerebrovascular system, essential for maintaining brain function, is highly sensitive to environmental changes. Cerebrovascular diseases represent one of the characteristic adverse effects of deep space conditions such as microgravity and high-energy radiation, and have emerged as a frontier challenge in space medicine. Based on experiences from manned space missions, major research challenges persist, particularly the lack of experimental data specific to the lunar environment and the unclear threshold for low-dose radiation-induced injury. Elucidating the mechanisms and multifactorial interactions by which deep space environments impact cerebrovascular structure and function, and summarizing the key risk factors, pathological processes, and recent advances in monitoring and early-warning technologies for cerebrovascular diseases in lunar astronauts, and of crucial importance. A comprehensive understanding of the interplay between deep space environmental stressors and cerebrovascular injury, as well as the development of personalized prevention and intervention strategies, will provide both theoretical and practical foundations for safeguarding cerebrovascular health in future Chinese deep space missions, while promoting progress in related biomedical research, technological innovation, and international collaboration.
Humans
;
Astronauts
;
Cerebrovascular Disorders/etiology*
;
Space Flight
;
Weightlessness/adverse effects*
;
Risk Factors
;
Moon
7.Anesthesia management experience in transcatheter ultrasound-guided percutaneous interventional treatment of congenital heart disease at a mobile operating platform
Chunmei XIE ; Da ZHU ; Shouzheng WANG ; Yaling FENG ; Jiang LU ; Jianbin GAO ; Ke YANG ; Xinghuan LI ; Deyuan ZHANG ; Xiangbin PAN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(10):1467-1472
Objective To explore the anesthesia management experience in the interventional treatment of pediatric congenital heart diseases (CHD) percutaneously guided by transthoracic echocardiography (TTE) on a mobile operating platform. Methods From March to July 2023, a total of 13 patients from remote areas underwent interventional treatment for CHD on the mobile operating platform of Fuwai Yunnan Cardiovascular Hospital. Patients who received non-tracheal intubation general anesthesia were retrospectively included. Results Eight children who had difficulty cooperating with the surgery (due to young age, emotional tension, crying) received monitored anesthesia care with local anesthesia supplemented by sedative and analgesic drugs while maintaining spontaneous breathing under the monitoring and management of an anesthesiologist (i.e., non-tracheal intubation general anesthesia). Among them, there were 5 males and 3 females, with an age of (6.95±3.29) years and a body weight of (19.50±6.04) kg. Through transthoracic echocardiography, they were diagnosed with atrial septal defect (6 patients), residual shunt after patent ductus arteriosus ligation (1 patient), and severe pulmonary valve stenosis (1 patient). The surgery proceeded smoothly, with satisfactory anesthesia and surgical effects, complete analgesia, and satisfactory postoperative recovery. There was 1 patient of body movement and 1 patient of respiratory depression during the operation, and both patients completed the surgery successfully after treatment. All children had no serious surgery- and anesthesia-related complications. The anesthesia time was 40.5 (34.5, 47.5) min, the surgery time was 39.0 (33.0, 45.5) min, and the recovery time was 43.0 (28.0, 52.5) min Conclusion Interventional surgery for CHD guided by TTE at a mobile platform is a minimally invasive approach without radiation damage. Non-tracheal intubation general anesthesia with spontaneous breathing can be safely and effectively implemented in children who cannot cooperate.
8.Transcatheter closure of atrial septal defect using fully biodegradable occluder under ultrasound guidance: A case report
Ying' ; ao ZHAO ; Yiming YAN ; Ziping LI ; Hang LI ; Fengwen ZHANG ; Fang FANG ; Guangzhi ZHAO ; Jing DONG ; Chuangshi WANG ; Jiande WANG ; Wenbin OUYANG ; Xiangbin PAN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(12):1796-1799
Currently, transcatheter intervention is the preferred treatment for patients with anatomically suitable atrial septal defects. However, the use of nickel-titanium alloy occluders in interventional procedures results in lifelong presence of the implant in the body, leading to complications such as metal allergies and arrhythmias in some patients. To overcome the short-term and long-term complications associated with the presence of metal, and to avoid radiation exposure and metal toxicity, this paper reports a case of successful transcatheter closure of atrial septal defect in a pediatric patient with metal allergies using fully biodegradable occluder under ultrasound guidance, achieving excellent results by interventional therapy.
9.Establishment of patent ductus arteriosus model in Bama miniature pigs using autogenous jugular vein
Jian LI ; Wenchao LI ; Fengwen ZHANG ; Donglin ZHUANG ; Peijian WEI ; Hang LI ; Min ZHANG ; Wenbin OUYANG ; Xiangbin PAN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2024;31(12):1832-1837
Objective To explore the method and feasibility of establishing patent ductus arteriosus (PDA) model in Bama miniature pig by using autologous jugular vein, and to provide a large animal model for the development of PDA occluder and the study of pulmonary hypertension associated with congenital heart disease. Methods Five male Bama miniature pigs weighing about 45 kg were selected to gain the PDA model of the autogenous jugular vein, which was fixed by glutaraldehyde and anastomosed between the ascending aorta and the main pulmonary artery. The patency of PDA was confirmed by echocardiography and angiocardiography immediately and one week after the operation. Two animals were selected to undergo transcatheter closure of PDA via femoral vein 1 week after the operation, and the rest were euthanized to obtain PDA and lung tissue for pathological examination. Results The PDA model was successfully established in all five animals with a success rate of 100.0%. Immediately and 1 week after the operation, echocardiography and angiography showed that PDA blood flow was unobstructed, and hematoxylin-eosin staining showed that PDA endothelialization was good. One week after the operation, two animals were successfully treated with transcatheter femoral vein occlusion. The pathological examination of lung tissue showed thickening of the intima and muscular layer of pulmonary arterioles, thickening of pulmonary interstitium and infiltration of neutrophils. Conclusion It is safe and feasible to establish a large animal model of PDA by using autogenous jugular vein anastomosis between the ascending aorta and the main pulmonary artery. The model can be used for the development of PDA interventional occlusive devices and the pathophysiological study of congenital heart disease-related pulmonary hypertension.
10.Early outcome of balloon-expandable valves in the treatment of severe aortic stenosis: A single-center study
Yihang LI ; Jingnan ZHANG ; Fang FANG ; Junyi WAN ; Liang XU ; Xiangbin PAN ; Gejun ZHANG
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2024;31(07):1007-1013
Objective To evaluate the safety and early-stage efficacy of transcatheter aortic valve replacement (TAVR) for severe aortic stenosis (AS) using a new generation balloon-expandable (BE) valve by collecting the baseline and follow-up data. Methods We retrospectively reviewed the clinical data of severe AS patients who received TAVR with BE valve (Sapien 3) in Fuwai Hospital from September 2020 to June 2022. We collected the echocardiographic data as well as follow-up results at post-procedure, 1, 3, 6 and 12 months. According to the Sievers classification criteria, the patients were divided into a normal group and a bicuspid aortic valve group. Results Finally 62 patients were collected, including 31 females and 31 males with an average age of 71.44±9.17 years. There was 61 patients implanted successfully with BE valve and only 1 was transferred to surgical replacement. There was no mortality or severe complications. Echocardiographic assessment showed significant reduction of the pressure gradient (P<0.001) and the effect was consistent to postoperative 12 months. After the treatment of patients with different aortic valve morphology using balloon dilation, the condition of valve stenosis improved. Conclusion The use of BE valves has good safety and early efficacy in patients with severe AS of different valve morphology.

Result Analysis
Print
Save
E-mail