1.Analysis of Quality Changes of Small Packaged Alismatis Rhizoma Decoction Pieces Under Different Packaging and Storage Conditions
Gaoting YANG ; Rui XIAN ; Zimin WANG ; Zongyi ZHAO ; Zhiqiong LAN ; Xiaoli PAN ; Min LI
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(2):179-188
ObjectiveTo screen suitable packaging and storage conditions for small packaged Alismatis Rhizoma decoction pieces, laying the foundation for developing standardized storage, maintenance techniques and determining shelf life. MethodsUsing the accelerated stability test method, the small packaged decoction pieces of Alismatis Rhizoma were placed in polyethylene plastic bags, aluminum foil polyethylene composite bags, and cowhide coated paper bags under temperature of (40±2) ℃ and relative humidity of (75±5)% conditions, the quality testing was conducted at the end of the 0th, 1st, 2nd, 3rd, and 6th month, respectively. Using long-term stability test method, an orthogonal experiment was designed to investigate storage conditions, packaging materials, and packaging methods. At the end of the 0th, 1st, 3rd, 6th, 9th, 12th, 18th, and 24th month, the quality of small packaged Alismatis Rhizoma decoction pieces was tested under different packaging and storage conditions(including 2 packaging methods:vacuum packaging and sealed packaging, 3 storage conditions:room temperature, cool, and modified atmosphere, 3 packaging materials:cowhide coated paper bag, aluminum foil polyethylene composite bag, and polyethylene plastic bag). Then, the G1-entropy weight method combined with orthogonal experiment was used to analyze the quality changes of the decoction pieces under different packaging and storage conditions to identify optimal packaging and storage conditions. The quality testing indicators for Alismatis Rhizoma decoction pieces were expanded beyond those specified in the 2020 edition of the Pharmacopoeia of the People's Republic of China. In addition to the existing indicators(characteristics, moisture content, extractives, and the total content of 23-acetyl alisol B and 23-acetyl alisol C), new indicators including color value, water activity, total triterpenoid content, and alisol B content have been added. ResultsThe accelerated stability test results indicated that the quality of small packaged Alismatis Rhizoma decoction pieces was more stable when packaged in aluminum foil-polyethylene composite materials compared to cowhide-coated paper bags and polyethylene plastic bags. Analysis of the long-term stability test results using the G1-entropy weight method combined with orthogonal experiment revealed that storage conditions had the greatest impact on both raw and salt-processed products, followed by packaging materials, while the packaging method had the least influence. For both types of small packaged Alismatis Rhizoma decoction pieces, modified atmosphere storage demonstrated superior efficacy compared to cool storage or room temperature storage. Storage in aluminum foil-polyethylene composite bags was superior to polyethylene plastic bags or cowhide-coated paper bags. However, the stability of sealed raw products was better than vacuum-packed ones, whereas vacuum-packed salt-processed products exhibited greater stability than their sealed counterparts. ConclusionBased on the results of the quality changes of small packaged Alismatis Rhizoma decoction pieces under different storage conditions, it is recommended that the suitable storage packaging conditions for small packaged raw products are sealed packaging with aluminum foil polyethylene composite bags and controlled atmosphere storage, and the suitable storage and packaging conditions for small packaged salt-processed products are vacuum packaging with aluminum foil polyethylene composite bags and controlled atmosphere storage.
2.Recent Advances of Carbon Dots in Chemiluminescence
Yu-Jie XIAO ; Xuan TAN ; Yue ZHAO ; Ke CHENG ; Xue ZHANG ; Xian YANG ; Hong ZHENG
Chinese Journal of Analytical Chemistry 2025;53(1):27-37
Chemiluminescence,as a self-luminous phenomenon that does not require light,heat,acoustic,electric and magnetic excitation,has been widely used in the fields of analytical chemistry,cold light source and bio-imaging because of its advantages including high sensitivity,wide linear range,simple equipment and fast detection speed compared with other analytical techniques.Carbon dots(CDs)are a class of nanomaterials with excellent photoluminescence properties and high biocompatibility.CDs are stable,easy to prepare and abundant in types,and researchers have introduced many types of CDs into different chemiluminescence systems.In this paper,the applications of CDs in common chemiluminescence systems and the possible mechanisms of action were discussed,and the research progresses on the application of CDs in different chemiluminescence detection fields in recent years were summarized.Finally,the development trend of CDs in chemiluminescence was analyzed.
3.Nontarget Screening and Identification of Novel Per-and Polyfluoroalkyl Substances in Cosmetics Using Ultra-High Performance Liquid Chromatography-High-Resolution Mass Spectrometry
Xin-Ling LI ; Tao YANG ; Wen-Yao LIANG ; Jian-Hua TAN ; Xian-Zhi PENG
Chinese Journal of Analytical Chemistry 2025;53(4):640-651,中插23-中插28
Cosmetics may be an important source of human exposure to per-and polyfluoroalkyl substances(PFASs),posing risks to human health.In this study,a nontarget screening method for PFASs in cosmetics was developed using ultra-high performance liquid chromatography-high-resolution mass spectrometry(UHPLC-Q-Orbitrap HRMS)based on the Kendrick mass defect(KMD).The sample was extracted by ultrasonic assisted extraction prior to being analyzed by UHPLC-Q-Orbitrap HRMS.Acquisition of HRMS data was achieved in both full scan and data-dependent(Full MS/dd MS2)mode.The data collected by HRMS were imported into an in-lab built R script for processing.Samples retained the mass spectra peaks with KMD values in the range of 0.85-1 or 0-0.15 for in-and out-of-library matching;when KMD deviation(δKMD)<0.001 and CF 2 mass error(δMS)<15 ppm,it was considered as a potential PFASs homologues.According to matches of parent ions(MS),fragment ions(MS2)and retention time(RT)with the in-house built PFASs database,the screened and identified potential PFASs were categorized to 5 confidence levels(CL1-CL5).A total of 15 kinds of PFASs homologues with confidence level of CL3 and above were screened from 13 cosmetics products and 8 cosmetic raw materials,including perfluoroalkyl alcohol,hydroperfluoroalkyl sulfonic acid,chloroperfluoroalkyl sulfonic acid,etc.with concentrations ranging from 1.9 ng/g to 98.1 ng/g.The nontarget screening method could be used to screen and identify PFASs homologues feasibly and therefore provided data basis for management and control of PFASs addition in cosmetics.
4.Simultaneous Determination of 21 Kinds of Aconitum Alkaloids in Biological Specimens and Herbal Wines Using Ultra-Performance Liquid Chromatography-Tandem Mass Spectrometry
Ju YANG ; Guo-Jun LI ; Xian-Mou FAN ; Rui-Bin ZHAO ; Shao-Ming SU ; Xu-Xian FU ; En-Jin ZHU ; Qi-Lin HUANG ; Yao QIN ; Li-Na LI
Chinese Journal of Analytical Chemistry 2025;53(8):1391-1401,后插1-后插6,封3
A method for simultaneous determination of 21 kinds of Aconitum alkaloids(ATS)in biological specimens and infused liquor using ultra-performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS)was developed.The biological samples were pretreated with methanol-acetonitrile(1∶2,V/V)for protein precipitation,while infused liquors were diluted 100-fold with acetonitrile,followed by centrifugation,and filtration by a 0.22-μm membrane.Chromatographic separation was carried out on an EC-C18 column using gradient elution with the mixture of 10 mmol/L ammonium acetate and 0.2%formic acid as mobile phase A and acetonitrile as mobile phase B.With this method,all the analytes were separated within 9.5 min.The samples were detected in positive ESI mode with dynamic multiple reaction monitoring(MRM)and quantified via external standard calibration.The results showed that the concentrations of the analytes in the range of 2-1000 ng/mL had excellent linearity(R2>0.9992)with the peak area.The developed method was successfully used for detection of 21 kinds of aconitum alkaloids,with limits of detection of 0.5-2 ng/mL,quantification limits of 2-6 ng/mL,intra/inter-day precision≤6.0%,spiked recoveries of 89.4%-100.9%,extraction recoveries of 74.2%-104.4%,and matrix effects ranging from-11.1%to 9.2%in blood/urine.The method was applied to detection of 12 samples from 4 fatal aconite poisoning cases,and all 21 kinds of ATS with total alkaloid concentrations of 0.04-4.18 μg/mL in blood and 154.96-422.83 μg/mL in medicinal liquors were detected.Tissue distribution revealed that the order of concentrations from highest to lowest is as follows:urine(157.22 μg/mL)>gastric contents(51.37 μg/mL)>kidney(21.6 μg/g)>whole blood(4.18 μg/mL)>liver(0.03 μg/g).This method showed many advantages such as simple pretreatment,low detection limits,accurate quantification,broad analyte coverage,and superior anti-interference capability in complex matrices,proving ideal for forensic and toxicological analysis of aconitum alkaloids.
5.Preparation,Properties and In Vitro Release Behavior Study of Inclusion Complex of Taxifolin with 2-Hydroxypropyl-β-cyclodextrin
Shui-Xian MA ; Xin TAO ; Yun-Han YANG ; Sha XIA ; Yu-Xiang YANG ; Li YANG ; Li-Juan YANG
Chinese Journal of Analytical Chemistry 2025;53(10):1684-1693
The inclusion complex of taxifolin(TAX)with hydroxypropyl-β-cyclodextrin(HP-β-CD)was prepared by saturated aqueous solution method,and the preparation conditions such as molar ratio,volume ratio of solution,inclusion temperature and inclusion time were selected by single-factor experiment.The orthogonal design of three-level four-factor L9(34)was used to screen the preparation process of the inclusion complex,and the inclusion complex was prepared with optimal preparation process.The prepared inclusion complex was characterized by scanning electron microscopy(SEM),nuclear magnetic resonance(1H NMR,2D NMR),Fourier transform infrared spectroscopy(FT-IR),ultraviolet-visible(UV-Vis)absorption spectroscopy and X-ray powder diffraction(XRD).The inclusion ratio,biostability,solubility and in vitro release of the inclusion complex were investigated.The results of orthogonal experiments showed that the optimum conditions for preparation of the inclusion complex were as follows:the molar ratio of TAX to HP-β-CD was 1:1,the volume ratio of methanol to ultra-pure water was 1:8,the inclusion time was 8 h,and the inclusion temperature was 30℃.Under the optimal conditions,the inclusion ratio between TAX and HP-β-CD was calculated to be 1:1 by Job's curve method.According to the change of UV-vis absorption spectra,the host-guest complexation constant of 4.9488×104 L/mol was obtained by Benesi-Hildebrand curve method.The solubility of TAX increased from 1.2665 mg/mL to 19.3469 mg/mL after inclusion,demonstrating that HP-β-CD could serve as an effective host molecule for TAX,which could significantly enhance the bio-stability and solubility of the formed inclusion complex.
6.Optimization of Laser-Induced Breakdown Spectroscopy Parameters for Phosphorus Detection in Water Using Orthogonal Experiment
Xin-Yan YANG ; Xin WANG ; Wen-Wen ZHOU ; Yi-Heng LI ; Peng ZHU ; Bin WANG ; Xian-Feng ZHENG
Chinese Journal of Analytical Chemistry 2025;53(11):1921-1930
Aerosol-assisted plasma amplification laser-induced breakdown spectroscopy(LIBS)was employed for phosphorus detection in water.To address the multivariate coupling effects in LIBS and nebulization sampling system,an orthogonal experiment was employed to systematically optimize the key experimental parameters.Using the orthogonal experimental design,the parametric effects of laser energy(output voltage),signal acquisition delay,liquid velocity,and gas velocity on the signal to background ratio(SBR)of P I 213.618 nm were evaluated,and the optimal conditions were achieved,including laser energy of 86 mJ,delay time of 3 μs,gas velocity of 1.05 mL/min,and liquid velocity of 60 μL/min,which were in agreement with the control-variable optimization results.Moreover,the SBR response trends at P I 213.618 nm with all experimental parameters was strong in consistency with control-variable optimization results,which demonstrated the validity of the orthogonal array experimental design.This study established an efficient and accurate parameter optimization methodology for complex LIBS systems,significantly advancing the application of LIBS in environmental monitoring.
7.The relationship between the level of Caveolin-1 and HMGB-1 in cerebrospinal fluid and the severity of sepsis and their predictive value
Xian WANG ; Jing WANG ; Zhonghui YANG ; Jing LU ; Shuo LIANG ; Liru CUI
International Journal of Laboratory Medicine 2025;46(3):281-286
Objective To explore the relationship between the level of Caveolin-1 and high mobility group protein B1(HMGB-1)in cerebrospinal fluid and the severity of sepsis and their predictive value.Methods A total of 102 children with sepsis were selected in a hospital from June 2021 to December 2023.According to neonatal critical case scoring criteria,the children were divided into mild group(n=41)and severe group(n=61).According to the diagnostic criteria of purulent meningitis and the results of cerebrospinal fluid examina-tion,the children were divided into sepsis complicated with purulent meningitis group(n=16)and simple sepsis group(n=86).The clinical data of the children were collected,and the levels of Caveolin-1,HMGB-1 and inflammatory factors[hypersensitive C-reactive protein(hs-CRP),procalcitonin(PCT)and tumor necro-sis factor-α(TNF-α)]in cerebrospinal fluid of the children were detected by enzyme-linked immunosorbent assay.Multivariate Logistic regression analysis was conducted to analyze the factors affecting the severity of sepsis,and the receiver operating characteristic curve was drawn to analyze the diagnostic value of Caveolin-1 and HMGB-1 in the severity of sepsis and the prediction value of purulent meningitis in the children.Results Compared with mild group,cerebrospinal fluid levels of Caveolin-1 and HMGB-1 in severe group were signifi-cantly increased,and the difference was statistically significant(P<0.05).The levels of PCT,hs-CRP and TNF-α in severe group were significantly higher than those in mild group,and the difference was statistically significant(P<0.05).Multivariate Logistic regression analysis showed that PCT,hs-CRP,TNF-α,Caveolin-1 and HMGB-1 levels were all risk factors for the severity of sepsis in children(P<0.05).The combined diag-nosis of Caveolin-1 and HMGB-1 was significantly better than that of Caveolin-1(Z=2.109,P=0.035),HMGB-1(Z=2.099,P=0.036),PCT(Z=2.487,P=0.013),hs-CRP(Z=2.419,P=0.016)and TNF-α(Z=3.441,P=0.001)were diagnosed alone.Compared with simple sepsis group,cerebrospinal fluid Caveo-lin-1 and HMGB-1 levels in sepsis complicated with purulent meningitis group were significantly increased,and the difference was statistically significant(P<0.05).The combined prediction of Caveolin-1 and HMGB-1 was significantly better than that of Caveolin-1(Z=2.621,P=0.009)and HMGB-1(Z=1.997,P=0.046)alone.Conclusion There are significant increases in the levels of Caveolin-1 and HMGB-1 in chil-dren with severe sepsis or sepsis complicated with purulent meningitis.Caveolin-1 and HMGB-1 have a certain clinical value in evaluating the severity of sepsis in children and predicting whether they are complicated with purulent meningitis.
8.Evaluation of the performance and application value of EasyNAT nucleic acid test kits for influenza A/B viruses and Mycoplasma pneumoniae based on cross-primed amplification technology
Shaolan YANG ; Xing LI ; Tao XIAN ; Yafei LI ; Li JIANG ; Shi HUA
International Journal of Laboratory Medicine 2025;46(17):2142-2147
Objective To evaluate the performance and clinical application value of EasyNAT nucleic acid test kits for influenza A virus(Flu A),influenza B virus(Flu B),and Mycoplasma pneumoniae(MP)based on cross-primed amplification(CPA)technology.Methods In compliance with relevant standards,the detection limits,cross-reactivity,and anti-interference abilities of the EasyNAT Flu and MP nucleic acid test kits were validated using influenza(Flu)and MP reference materials.Additionally,a total of 811 suspected Flu or MP infection patients who visited the hospital from January 1 to July 5,2024 were enrolled in this study.Their oropharyngeal swabs were collected and tested using reverse transcription quantitative polymerase chain reac-tion(RT-qPCR)as the gold standard to evaluate the concordance and compliance of the EasyNAT Flu and MP nucleic acid test kits,thus assessing their clinical application value.Results The EasyNAT Flu and MP nucleic acid test kits yielded positive results in 8 repeated tests at the detection limit concentrations of the ref-erence materials.No pathogen-specific peaks were detected in Flu and MP negative samples that had been spiked with common cross-reacting pathogens.Furthermore,the detection results of Flu or MP positive sam-ples were unaffected by the presence of interfering substances.Among the 811 clinical samples,the sensitivity of the EasyNAT Flu A test was 97.33%,and the sensitivity for Flu B was 98.47%,both with a specificity of 98.04%.The EasyNAT MP nucleic acid test showed a sensitivity of 97.95%and specificity of 99.03%.The results demonstrated a high degree of agreement with RT-qPCR(Kappa values were over 0.900).Further-more,detection rates of the EasyNAT Flu test kits showed no difference in positive samples with different Ct values(Flu A:χ2=4.20,P=0.08;Flu B:χ2=2.22,P=0.31)and MP test kits showed significant differences in positive samples with different cycle threshold values(χ2=11.84,P<0.01).Conclusion The EasyNAT Flu and MP nucleic acid test kits exhibit excellent detection performance with high sensitivity and specificity.Moreover,the products are easy to operate,offer rapid detection,and provide accurate results.These features make them suitable for primary healthcare settings,with significant potential for clinical application.
9.Stress analysis of computer aided design/computer aided manufacture post-core materials with different elastic moduli
Liangwei XU ; Xitian TIAN ; Lin CHEN ; Hongyan GAO ; Xian ZHU ; Guican YANG ; Yinghao CHEN
Chinese Journal of Tissue Engineering Research 2025;29(10):2061-2066
BACKGROUND:Post and core restoration is a common choice for tooth defects,but the repair effects of various post and core materials are different. OBJECTIVE:To evaluate the stress distribution at the post and core,tooth root,and bonding agent site of post and core models made of different elastic modulus post and core materials using finite element method. METHODS:A three-dimensional root canal treated maxillary central incisor model was built using three-dimensional modeling software,which was restored with a full ceramic crown.The post and core materials in the restoration used nanoceramic resin(elastic modulus=12.8 GPa),composite resin(elastic modulus=16 GPa),hybrid ceramic(elastic modulus=34.7 GPa),glass ceramic(elastic modulus=95 GPa),titanium alloy(elastic modulus=112 GPa),and zirconia(elastic modulus=209.3 GPa).The model was fixed in cortical bone.A 100 N concentrated force of 45° from the long axis of the tooth was applied to 1/3 of the crown and tongue side of the central incisor.The stress distribution of the post and core,dentin,and tooth-root bonding agent in the model was repaired by the maximum principal stress criterion. RESULTS AND CONCLUSION:(1)When the post and core materials with higher elastic modulus was used,the post-core stress in the repair model was more concentrated.When the elastic modulus of the post and core materials(nanoceramic resin and composite resin)was close to dentin,the stress distribution of the post and core was more uniform.The stress distribution of dentin in all restoration models was similar regardless of post and core materials.When the post and core with higher elastic modulus was used,more stress concentration was shown at the post and root bonding agent in the repair model.(2)The maximum stress values at the post and core,tooth root,and the bonding agent site of post and tooth root in the nanoceramic resin model were 31.00,33.21,and 0.51 MPa,respectively.The maximum stress values at the post and core,tooth root,and the bonding agent between the post and tooth root in the composite resin model were 36.84,33.14,and 0.59 MPa,respectively.In the mixed ceramic model,the maximum stress values at the post and core,tooth root,and the bonding agent between the post and tooth root were 64.05,32.83,and 1.00 MPa,respectively.In the glass ceramic model,the maximum stress values at the post and core,tooth root,and the bonding agent between the post and tooth root were 112.30,32.69,and 1.73 MPa,respectively.In the titanium alloy model,the maximum stress values of the post and core,tooth root,and the bonding agent between the post and tooth root were 120.00,32.17,and 1.86 MPa,respectively.In the zirconia model,the maximum stress values of the post and core,tooth root,and the bonding agent between the post and tooth root were 148.80,31.85,and 2.28 MPa,respectively.(3)The higher the elastic modulus of the post and core material,the higher the maximum stress at the post and core during restoration.The elastic modulus of the post and core material had no significant effect on the maximum stress of the dental bonding agent and dentin.
10.Prediction of quality markers for cough-relieving and phlegm-expelling effects of Kening Granules based on plasma pharmacology combined with network pharmacology and pharmacokinetics.
Qing-Qing CHEN ; Yuan-Xian ZHANG ; Qian WANG ; Jin-Ling ZHANG ; Lin ZHENG ; Yong HUANG ; Yang JIN ; Zi-Peng GONG ; Yue-Ting LI
China Journal of Chinese Materia Medica 2025;50(4):959-973
This study predicts the quality markers(Q-markers) for the cough-relieving and phlegm-expelling effects of Kening Granules based on pharmacodynamics, plasma drug chemistry, network pharmacology, and pharmacokinetics. Strong ammonia solution spray and phenol red secretion assays were employed to evaluate the cough-relieving and phlegm-expelling effects of Kening Granules. Twentysix absorbed prototype components of Kening Granules were identified by ultra high performance liquid chromatography coupled with QExactive Plus quadrupole/Orbitrap high resolution mass spectrometry(UHPLC-Q-Exactive Plus Orbitrap HRMS). Through network pharmacology, 11 potential active components were screened out for the cough-relieving and phlegm-expelling effects of Kening Granules. The 11 components acted on 40 common targets such as IL6, TLR4, and STAT3, which mainly participated in PI3K/Akt, HIF-1, and EGFR signaling pathways. Pharmacokinetic quantitative analysis was performed for 7 prototype components. Three compounds including azelaic acid, caffeic acid, and vanillin were identified as Q-markers for the cough-relieving and phlegm-expelling effects of Kening Granules based on their effectiveness, transmissibility, and measurability. The results of this study are of great significance for clarifying the pharmacological substance basis, optimizing the quality standards, and promoting the clinical application of Kening Granules.
Drugs, Chinese Herbal/administration & dosage*
;
Network Pharmacology
;
Cough/blood*
;
Male
;
Humans
;
Animals
;
Rats
;
Rats, Sprague-Dawley
;
Biomarkers/blood*
;
Quality Control
;
Chromatography, High Pressure Liquid
;
Antitussive Agents/chemistry*

Result Analysis
Print
Save
E-mail