1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Expert Consensus on the Ethical Requirements for Generative AI-Assisted Academic Writing
You-Quan BU ; Yong-Fu CAO ; Zeng-Yi CHANG ; Hong-Yu CHEN ; Xiao-Wei CHEN ; Yuan-Yuan CHEN ; Zhu-Cheng CHEN ; Rui DENG ; Jie DING ; Zhong-Kai FAN ; Guo-Quan GAO ; Xu GAO ; Lan HU ; Xiao-Qing HU ; Hong-Ti JIA ; Ying KONG ; En-Min LI ; Ling LI ; Yu-Hua LI ; Jun-Rong LIU ; Zhi-Qiang LIU ; Ya-Ping LUO ; Xue-Mei LV ; Yan-Xi PEI ; Xiao-Zhong PENG ; Qi-Qun TANG ; You WAN ; Yong WANG ; Ming-Xu WANG ; Xian WANG ; Guang-Kuan XIE ; Jun XIE ; Xiao-Hua YAN ; Mei YIN ; Zhong-Shan YU ; Chun-Yan ZHOU ; Rui-Fang ZHU
Chinese Journal of Biochemistry and Molecular Biology 2025;41(6):826-832
With the rapid development of generative artificial intelligence(GAI)technologies,their widespread application in academic research and writing is continuously expanding the boundaries of sci-entific inquiry.However,this trend has also raised a series of ethical and regulatory challenges,inclu-ding issues related to authorship,content authenticity,citation accuracy,and accountability.In light of the growing involvement of AI in generating academic content,establishing an open,controllable,and trustworthy ethical governance framework has become a key task for safeguarding research integrity and maintaining trust within the academic community.This expert consensus outlines ethical requirements across key stages of AI-assisted academic writing-including topic selection,data management,citation practices,and authorship attribution.It aims to clarify the boundaries and ethical obligations surrounding AI use in academic writing,ensuring that technological tools enhance efficiency without compromising in-tegrity.The goal is to provide guidance and institutional support for building a responsible and sustainable research ecosystem.
3.Application of ArcherQA for independent dose verification of SRT plans for CyberKnife
Xuyao YU ; Yuwen WANG ; Yang DONG ; Daguang ZHANG ; Yongchun SONG ; Qiang REN ; Xi PEI ; Zhiyong YUAN ; Wei WANG ; Jianrong DAI
Chinese Journal of Radiation Oncology 2025;34(11):1139-1145
Objective:To evaluate the feasibility of using the domestic ArcherQA system for fast and simplified independent verification of CyberKnife (CK) stereotactic radiotherapy (SRT) plans.Methods:SRT plans of 57 patients treated with CK at Tianjin Medical University Cancer Institute and Hospital from August 2021 to August 2022 were retrospectively analyzed, including 15 intracranial, 30 pulmonary, and 12 abdominal tumors cases. Point-dose and planar-dose verifications were performed using an ionization chamber and radiochromic films embedded in a homogeneous phantom, and the results were compared with those calculated by the treatment planning system (TPS). The localization CT images and corresponding SRT plans were imported into the ArcherQA system for independent dose verification and analysis. The correlation between ArcherQA results and phantom measurements was analyzed, with comparisons of target mean dose differences and γ pass rates.Results:Phantom measurement results showed, the measured point-dose differences for intracranial, lung, and abdominal plans were -0.94% ± 3.22%, 1.92% ± 2.05%, and 2.12% ± 0.77%, respectively. The mean dose differences in target dose calculation between ArcherQA and TPS: intracranial in the gross tumor volume (GTV) regions were 0.34% ± 2.21%, lung tumor GTV were -2.47% ± 2.46%, and abdominal tumor GTV were 0.80% ± 2.61%, respectively. Among them, the abdominal GTV region showed the highest correlation between ArcherQA and measured results ( r=0.78). The average two-dimensional γ pass rates (2 mm/2%, threshold=10%) measured using phantom films were 95.92% ± 2.35% for intracranial, 95.70% ± 2.74% for lung, and 96.74% ± 3.41% for abdominal tumors plans, respectively. The three-dimensional ArcherQA results showed comparable γ pass rates (1 mm/2%, threshold=10%) for lung and abdominal GTV and PTV regions, with similar medians and data dispersion to film measurements. Conclusions:The ArcherQA system enables rapid and efficient independent dose verification of CK SRT plans without the need for additional hardware. The verification results show good correlation with phantom measurements, supporting its potential as an auxiliary quality assurance tool in clinical CK SRT implementation.
4.Clinical Application of Ultrasound-guided Cervical Plexus Block Combined with Superior Laryngeal Nerve Block in Tracheostomy in Burn Patients
Shuang-ping OU ; Jiang-tao LIU ; Xi LIAO ; Pei-yang XU ; Ming LIU
Progress in Modern Biomedicine 2025;25(11):1822-1829
Objective:To investigate the clinical application of ultrasound-guided cervical plexus block combined with superior laryngeal nerve block in tracheotomy for burn patients.Methods:A total of 88 burn patients who underwent tracheotomy from January 2022 to December 2022 were divided into observation group(44 cases)and matched group(44 cases).The matched group received conventional general anesthesia,while the observation group underwent ultrasound-guided cervical plexus block combined with superior laryngeal nerve block.The operation time,anesthetic effect,intraoperative hemodynamic parameters,postoperative complications,and patient satisfaction were compared.Results:The surgery time in the observation group was shorter than that in the matched group(P<0.05).The anesthetic effect in the observation group was superior to that in the matched group,with more stable intraoperative hemodynamics,and smaller fluctuations in heart rate and mean arterial pressure(P<0.05).The incidence of postoperative cough reflex,hoarseness,postoperative pain score,and respiratory complications in the observation group were lower than those in the matched group(P<0.05).Patient satisfaction in the observation group was higher than that in the matched group(P<0.05).Conclusion:Ultrasound-guided cervical plexus block combined with superior laryngeal nerve block for tracheotomy in burn patients can effectively improve anesthetic effect,reduce operation time,stabilize intraoperative hemodynamics,reduce postoperative complications,and improve patient satisfaction,which is worthy of clinical application.
5.Prevalence and molecular characterization of Shiga toxin-producing Esch-erichia coli in domestic goats in the Chengkou District of Chongqing
Jing-jing PENG ; Bin HU ; Xi YANG ; Yi LI ; Hai HUANG ; Wen-shuang LIU ; Yu MENG ; Li-jun WANG ; Yan-wen XIONG ; Yi YUAN ; Pei-bin HOU
Chinese Journal of Zoonoses 2025;41(5):529-536
This study investigated the infection status,drug resistance,and molecular characteristics of Shiga toxin-producing Escherichia coli(STEC)in domestic goats in Chengkou county,Chongqing.In August 2023,283 fecal samples were collected from households in Chengkou county.After enrichment with EC broth and inoculation onto selective media,samples that tested positive for stx1/stx2 were selected for further isolation.The positive strains were investigated with antimicrobial susceptibility testing and whole genome sequencing.According to the whole genomic sequences,the stx subtypes,serotypes,multi-locus sequence types,virulence genes,drug resistance genes,and phylogenetic relationships of the STEC strains were analyzed.Forty-six strains of STEC were isolated from 283 goat fecal samples,thus resulting in a detection rate of 16.25%.The 46 STEC strains were categorized into 12 O∶H serotypes,among which O76∶H19 and O8∶H7 predominated,each represented by 9 strains.Five STEC strains were identified as serotype O157∶H7.The 46 STEC strains were categorized into 11 sequence types(STs),among which ST675 and ST196 predominated,each represented by nine strains,accounting for a 19.57%proportion.The strains were categorized into 7 stx subtypes,among which stx1c(26/46,56.52%),followed by stx2k(9/46,19.57%)predominated.All nine Stx2k-STEC strains were identified as serotype O8∶H7 and sequence type ST196.In antimicrobial susceptibility testing,2 STEC strains were resistant to ampicillin,one strain was resistant to ampicillin/sulbactam,one strain was resistant to cefazolin,and one strain was resistant to cefoxitin.Nine Stx2k-STEC strains were found to carry the beta-lactam resistance gene blaEC-18.Antimicrobial sensitivity tests revealed that the nine Stx2k-STEC strains were sensitive to all 15 tested antibiotics.Moreover,phylogenetic analysis indicated that the 9 Stx2k-STEC strains were remarkably similar but showed high genetic diversity with respect to that of the Stx2k-STEC strains isolated from other regions in China.Goatsare an important animal reservoir for STEC in theChengkou district of Chongqing,and novel sequence type Stx2k-STEC strains distinct from those found in other regions of China were identified in this region.
6.Impact of ischemia time and storage periods on RNA quality of fresh-frozen breast cancer and esophageal cancer tissue samples in biobank
Yang-si ZHENG ; Xuan-hao LIN ; Fan LI ; Kun-sheng XIAO ; Xi-feng CHEN ; Chun-peng LIU ; Pei-xiu YAO ; Shao-hong WANG
Fudan University Journal of Medical Sciences 2025;52(3):437-445
Objective To investigate the effects of ischemia time and storage periods on RNA quality in fresh-frozen breast cancer(BC)and esophageal cancer(EC)tissue samples in order to establish evidence-based protocols for biobank sample management.Methods The tumor(T)and paired normal(N)tissue samples from 6 cases of BC and 6 cases of EC were collected and cryopreserved in Biobank,Shantou Central Hospital.Mirror paraffin-embedded tissues were simultaneously prepared into sections for morphological analysis.The samples were divided into two groups of<15 min and 15-30 min according to ischemia time,and RNA quality was analyzed at 4 storage periods of 8-10 months(T1),14-16 months(T2),26-28 months(T3)and 38-40 months(T4).Results In 96 analyzed samples,93.8%(90/96)exhibited high quality(RIN≥6),with 89.6%(43/48)in BC and 97.9%(47/48)in EC.Significant differences in RIN were observed between BC group and EC group(8.050 vs.8.600,P=0.009).In EC group,RIN value was significantly negatively correlated with RNA yield(P<0.001).Moreover,RIN values of tumor-normal pairs exhibited markedly significant differences(7.550 vs.9.000,P<0.001).In contrast,no significant difference was detected in BC group(8.200 vs.7.700,P=0.348).Statistical analysis showed that RIN value was positively correlated with 28S/18S(P<0.001),but had no correlation with tumor content(P=0.676)and necrotic content(P=0.055).Neither ischemia time(<15 min vs.15-30 min:8.200 vs.8.300,P=0.932)nor storage periods(T1-T4:8.400,7.700,8.450,8.600,P=0.163)compromised RNA quality.Conclusion Organ origin and tissue type could influence RNA quality of fresh-frozen tissue samples.However,limited ischemia time(≤30 min)and long-term storage period(38-40 months)do not adversely affect RNA quality in fresh-frozen breast cancer and esophageal cancer tissue samples.
7.Best essential surgical technique training course to improve surgical residents′ laparoscopic peritoneal suturing skills: a cohort study
Zhenghao CAI ; Haiqin SONG ; Jing SUN ; Pei XUE ; Luyang ZHANG ; Chao WU ; Hiju HONG ; Xi CHENG ; Sen ZHANG ; Minhua ZHENG ; Lu ZANG ; Ruijun PAN ; Jianwen LI ; Bo FENG
Journal of Surgery Concepts & Practice 2025;30(2):132-137
Objective To explore the effectiveness of an integrated laparoscopic simulation training course (best essential surgical technique training, BEST) in enhancing laparoscopic peritoneal suturing techniques in surgical residents.Methods As an integrated two-stage program, the BEST course applied basic laparoscopic training system with simple molds in phase Ⅰ training, and then adopted advanced laparoscopic training system, 3D Laparoscope and ex-vivo animal models in phase Ⅱ training. The laparoscopic suturing techniques were practiced in phase Ⅱ training. From August 2021 to July 2024, surgical residents in the second year of the national standardized training program were divided into pilot and control groups based on whether they had undergone the BEST course. Two cases of laparoscopic peritoneal suture were performed by the surgical residents under supervision in the department of gastrointestinal surgery. The operative time, quality of suture, and independent completion rate were compared between the two groups.Results A total of 33 surgical residents (19 in pilot group and 14 in control group) were included in this study, and a total of 66 cases of laparoscopic peritoneal suture were performed (38 in pilot group and 28 in control group). The operative time was significantly shorter in pilot group than that in control group (15.7 min vs. 17.5 min, P=0.025). The quality of suture was significantly better in pilot group compared to control group (P=0.023). In pilot group, all peritoneal sutures were performed by residents independently, whereas in control group, 3 cases (10.7%) were assisted by the supervisor, and the independent completion rate was different significantly (P=0.039).Conclusions The BEST course can help improve surgical residents′ laparoscopic peritoneal suturing techniques and could be promoted in the national standardized training program for surgical residents.
8.Identification of Complex Samples Based on Broad Learning System and Physicochemical Indicators
Jia-Qi XIE ; Qiang ZHANG ; Pei-Ran LIU ; Ya-Fei YANG ; Xi-Hui BIAN
Chinese Journal of Analytical Chemistry 2025;53(6):944-954,中插16-中插21
Compared to traditional machine learning algorithms,which often suffer from low feature extraction efficiency,insufficient nonlinear pattern recognition capabilities and slow training speeds,the broad learning system(BLS)enhances the learning ability and efficiency by horizontally expanding the network structure.BLS offers advantages such as a simple structure,fast training speed,and strong generalization capabilities.While BLS has demonstrated potential in various fields,but its application in identification of complex samples has not been fully explored.This research investigated the feasibility of using BLS algorithm for identification of complex samples based on physicochemical indicators.Using the iris,wine,and breast cancer datasets,the length and width of petals and sepals of iris flowers,the physicochemical properties of wine,and the nuclear characteristics of breast cancer cells were used as input variables to establish BLS models for identifying iris species,wine varieties,and benign versus malignant nucleus.The model performance was evaluated by confusion matrices,accuracy,and runtime.Compared with partial least squares-discriminant analysis(PLS-DA),soft independent modeling of class analogies(SIMCA),and artificial neural networks(ANN),the results indicated that BLS demonstrated significant advantages in computational efficiency and recognition accuracy.Thus,BLS was an efficient and reliable method for identification of complex samples.
9.Exploration on the acceptability of routine biochemical test results for serum samples with varying degrees of chylous high triglyceride
Xi ZHANG ; Qing YANG ; Tao KANG ; Ge LI ; Zhiyang WANG ; Li ZHANG ; Xue WANG ; Pei LI ; Kan ZHONG ; Yanguo TAN
International Journal of Laboratory Medicine 2025;46(7):780-785
Objective To explore the acceptability of routine biochemical test results for serum samples with varying degrees of chylous high triglyceride(TG).Methods Blood samples of 69 patients with different degrees of lipids were collected,including 33 patients with mild to moderate lipids(1.7 mmol/L≤TG<5.6 mmol/L)and 36 patients with severe lipids(TG≥5.6 mmol/L).Twenty-nine biochemical tests were detected before and after high-speed centrifugation.The result acceptability before high speed centrifugation of serum was compared with the results after high speed centrifugation as the gold standard[TG and total cholesterol(TC)before centrifugation].The acceptable criteria were subject to the following three conditions at the same time.Firstly,correlation coefficient(R2)was greater than or equal to 0.95.Secondly,the slope of linear re-gression equation was 1.00±0.05.Thirdly,for the same index,the number of samples whose result bias be-fore and after centrifugation was less than 1/2 total allowable error(TEa)in more than 90%of the total sam-ple numbers.Results Firstly,in the mild to moderate lipemia group,22 tests met the criteria,7 tests did not,including total protein(TP),albumin(ALB),TG,aspartate aminotransferase(AST),carbon dioxide(CO2),α-L-fucosidase(AFU),lactate dehydrogenase(LDH)(bias<10%),and the coincidence rate was 75.9%.In the severe lipemia group,12 tests met the criteria,17 tests did not,including pre-albumin(PA),AFU,γ-glu-tamyltransferase(γ-GT),LDH,AST,TC,direct bilirubin(DBIL),CO2,5'-nucleotidase(5'-NT),small and low-density lipoprotein cholesterol(sd-LDL-C),high density lipoprotein cholesterol(HDL-C),low-density lipoprotein cholesterol(LDL-C),adenosine deaminase(ADA),cystatin C(CysC),glycosylated albumin(GA),total bilirubin(TBIL)(bias>10%),the coincidence rate was 41.4%,and there was a statistically sig-nificant difference in the coincidence rate between the two groups(P<0.05).Secondly,there was no statisti-cally significant difference in the acceptability of results between continuous monitoring method and endpoint method detection methods(P>0.05).Conclusion Most test results of direct determination with mild or moderate lipemia samples are acceptable,and the bias of unacceptable tests is small(<10%),so it is recom-mended to issue a test report without further sample treatment.However,due to the large number of unacceptable tests and larger bias(>10%),severe lipemia samples should be determined after high-speed centrifugation.
10.Monte Carlo simulation study of the effect of filter on radiotherapy dosimetry in superficial X-ray therapy apparatus
Li TAO ; Hui ZHANG ; Yikai WU ; Junyi LIU ; Miao QI ; Ning GAO ; Yankui CHANG ; Xi PEI ; Zhi CHEN ; Xie XU
Chinese Journal of Radiological Medicine and Protection 2025;45(3):194-201
Objective:To explore the dosimetry optimization strategy based on filter thickness and shape selection for the bulb superficial X-ray radiotherapy unit.Methods:Monte Carlo code TOPAS was used to model tubular equipment, and the dose distribution from six X-ray energies (50-150 kV) and five conventional aluminum filters (0.5-3.0 mm) with different thickness were simulated in the water model. The percentage depth dose (PDD) curve along the central axis, the center-axis profile dose at different depths, and the lateral dose distribution were analyzed. The dose distribution of three different designs of aluminum filters (conventional cylindrical, conical and oblique cylindrical filters) was compared to evaluate the effect of dosimetric optimization of different filter shapes.Results:Under the same energy, increasing the thickness of the filter can optimize the superficial skin dose, and the optimization effect of depth dose uniformity can be increased by 26% at a depth of 5.5 mm at 70 kV energy. The raised, flat and inclined dose distribution modes can be achieved by using conventional cylindrical, conical and inclined aluminum filters.Conclusions:By selecting the appropriate X-ray energy and filter thickness, an ideal dose distribution matching the tumor depth can be achieved. The application of personalized filters is also of great significance for diverse target areas.

Result Analysis
Print
Save
E-mail