1.Prognostic significance of TRIM28 elevation in non-M3 acute myeloid leukemia
Siqi GONG ; Cong LI ; Mengmeng FAN ; Huiping WANG ; Wanqiu ZHANG ; Xue LIANG ; Qianshan TAO ; Qiang HONG ; Zhimin ZHAI
Acta Universitatis Medicinalis Anhui 2026;61(2):301-308
ObjectiveTo clarify the expression of TRIM28 in non-M3 acute myeloid leukemia (AML) and its correlation with clinical indicators and prognosis, and to further explore the effect of TRIM28 expression levels on the proliferation and apoptosis of AML cells using small interfering RNA. MethodsThe GSE34577 dataset was analyzed using R software to compare TRIM28 expression between healthy controls and non-M3 acute myeloid leukemia (AML) patients. Clinical samples from non-M3 AML patients were collected, with TRIM28 expression levels measured using real-time quantitative PCR (qPCR). The analysis focused on correlations between TRIM28 expression and various clinical indicators, treatment efficacy, and patient prognosis. Furthermore, small interfering RNA (siRNA) technology was employed to downregulate TRIM28 expression in human primary AML cells (HL60 cell line). The effects on cell proliferation and apoptosis were then assessed through CCK-8 assays and flow cytometry, respectively. ResultsThe results showed that TRIM28 was up-regulated in non-M3 AML of both online database GSE34577 and clinical samples (P<0.000 1), TRIM28 expression of new diagnosis group and relapsed refractory group was higher than iron deficiency anemia group (P<0.01), and there was no significance between different French-American-British classification systems subtype. TRIM28 expression was higher in non-M3 AML patients with a poor genetic prognosis stratified as moderate than in the good prognosis group, and TRIM28 expression was associated with NPM1 combined with the FLT3-ITD mutation, positively correlated with age, bone marrow blast, peripheral blood blast and white blood cell, negatively correlated with hemoglobin. In addition, interference TRIM28 greatly inhibited cell proliferation and promoted cell apoptosis. ConclusionThis study reveals that TRIM28 is highly expressed in non-M3 AML and associated with prognosis, and plays a key role in the proliferation and apoptosis of AML cells, suggesting that TRIM28 may serve as a novel therapeutic target for non-M3 AML.
2.Compact Fundus Imaging System Using Shack-Hartmann Wavefront Sensing for High-speed Auto-focus
Zhe-Kai LIN ; Long CHEN ; Geng-Yong ZHENG ; Jin-Tian HUANG ; Jia-Xin DONG ; Shang-Pan YANG ; Wen-Zheng DING ; Ding-An HAN ; Xue-Hua WANG ; Ya-Guang ZENG
Progress in Biochemistry and Biophysics 2026;53(4):1076-1086
ObjectiveThe widespread adoption of portable fundus cameras for primary care and community screening is hindered by limitations in current autofocus(AF) technologies. Image-based methods relying on sharpness evaluation require iterative searches, resulting in slow convergence, while projection-based techniques are susceptible to optical artifacts and calibration errors. To address these challenges, this study introduces a novel AF system based on direct wavefront sensing, designed to deliver simultaneous high speed, high precision, and operational robustness within the compact form factor essential for portable ophthalmic devices. MethodsOur approach fundamentally reimagines the AF process by directly measuring the ocular wavefront aberration. We developed a custom portable fundus camera integrating a miniaturized Shack-Hartmann wavefront sensor (SHWS) into the optical path. An 850 nm laser diode projects a point source onto the retina via oblique illumination to minimize corneal reflections. Light scattered from this spot carries the eye’s refractive error through the imaging optics and is directed to the SHWS, positioned at a plane optically conjugate to the primary color CMOS imaging sensor. A microlens array within the SHWS samples the incident wavefront, generating a pattern of focal spots on a CCD. Real-time centroid analysis of these spots provides a map of local wavefront slopes. These measurements are processed through a singular value decomposition (SVD) algorithm to fit a Zernike polynomial basis set, enabling real-time reconstruction of the wavefront phase. The defocus component (S) is extracted from the second-order Zernike coefficients, providing a direct, quantitative measure of the refractive error in diopters. This value serves as a precise error signal in a closed-loop control system, which commands a voice-coil actuated focusing lens to its null position in a single, deterministic step, eliminating the need for iterative search algorithms. ResultsComprehensive evaluation demonstrated the system’s high performance. Testing on a calibrated model eye (OEMI-7) established a highly linear relationship between the computed defocus S and the focusing lens position across a ±20 Diopter (D) compensation range, achievable within a 5 mm mechanical travel. The system achieved a focusing precision of 0.08 D, corresponding to an 18-fold improvement over a conventional projection spot-size method tested under identical conditions. The total focus acquisition time, encompassing wavefront measurement, computation, and lens actuation, averaged under 0.5 s. Clinical validation with 25 human volunteers (50 eyes, refractive range -15 D to +10 D) confirmed practical efficacy. The wavefront-sensing AF succeeded in 92% of attempts with a mean time of 0.5 s, substantially outperforming a projection-based benchmark which achieved only a 32% success rate with an average time of 4.25 s. The system provided instantaneous directional guidance and maintained stability during minor ocular movements. Objective assessment of image quality, via amplitude contrast of retinal vasculature, showed consistent and significant enhancement following AF correction across the entire tested diopter range. ConclusionThis work successfully implements and validates a direct wavefront-sensing autofocus paradigm for portable fundus cameras. By directly quantifying and compensating for the optical defocus aberration, this method bypasses the fundamental limitations of image-processing and projection-based techniques, enabling rapid, precise, and deterministic diopter compensation. The developed system delivers an exceptional combination of a wide operational range (±20 D), high accuracy (0.08 D), fast convergence (0.5 s), and a compact physical footprint. This technology provides a practical and high-performance focusing solution capable of enhancing the reliability, throughput, and diagnostic utility of portable retinal imaging in large-scale screening applications. Future efforts will be directed towards system cost optimization and performance adaptation for diverse ocular conditions.
3.Application and Prospects of Simultaneous Multicomponent Extraction Technology in Biological Samples
Kun-Peng ZHANG ; Zi-Hong YE ; Zhi-Chao XUE
Progress in Biochemistry and Biophysics 2026;53(5):1400-1414
With the rapid development of the biopharmaceutical field, the efficient and simultaneous extraction of multiple biological components from biological samples has become a critical process for advancing scientific research. The ability to simultaneously extract various molecular components such as metabolites, DNA, RNA, and proteins is pivotal for multi-omics studies, which aim to comprehensively understand the molecular mechanisms of biological systems. Traditional methods often extract these components separately, leading to challenges such as sample loss, time consumption, contamination, and inconsistencies across different data types. In contrast, simultaneous extraction techniques address these issues by maintaining the consistency of each biological component’s physiological state, improving data reliability and facilitating integration across omic platforms. This review systematically summarizes recent advances in simultaneous extraction technologies, focusing on methods such as methanol/chloroform extraction, TRIzol reagent extraction, and modified Folch extraction, which have shown significant promise in improving the efficiency and integrity of biological sample preparation. These methods offer various advantages, such as reduced sample volume requirements, decreased contamination risk, and enhanced extraction consistency, which are crucial for studies involving small sample sizes or precious clinical specimens. Among these, methanol/chloroform extraction stands out for its simplicity, low cost, and ability to extract a wide range of biological molecules. However, it does face limitations, such as its inefficiency in extracting lipids and potential RNA contamination. On the other hand, the TRIzol reagent method has become a widely adopted technique due to its ability to simultaneously isolate RNA, proteins, and metabolites from the same sample. Despite its effectiveness, the TRIzol method has limitations in RNA quality, especially when handling complex samples or those with high protein content. Modified Folch extraction, which combines liquid-liquid extraction with commercial kits, offers a highly efficient way to extract polar metabolites, lipids, RNA, DNA, and proteins from small tissue samples. This method has proven advantageous in terms of extraction yield, especially for challenging or rare samples, although it requires precise handling to avoid cross-contamination between phases. The integration of automated platforms, microfluidics, and high-throughput systems is another exciting avenue for improving simultaneous extraction. Automation facilitates large-scale, reproducible sample processing with minimal human error, while microfluidics provides high precision in sample handling and enables real-time monitoring of extraction efficiency. These innovations not only enhance the speed and reproducibility of sample preparation but also open new possibilities for single-cell analysis, where sample volumes are often limited, and extraction efficiency is critical. In addition to the technical aspects, the review also highlights the importance of optimizing extraction protocols for specific sample types, such as clinical tissues, plants, and microorganisms. For example, the challenge of extracting multiple components from cancer tissues, where sample degradation and contamination risks are high, can be mitigated by carefully selecting extraction reagents and minimizing sample handling steps. Similarly, in plant studies, where metabolite diversity is vast, the simultaneous extraction methods must be optimized to account for the unique composition of plant tissues, which often include complex secondary metabolites and cell wall components. Looking forward, the development of more efficient and standardized simultaneous extraction methods will be crucial for advancing multi-omics research. There is a growing need for protocols that can be tailored to specific research needs, ensuring both reproducibility and flexibility in diverse applications. Additionally, combining these extraction methods with high-resolution analytical techniques such as mass spectrometry and next-generation sequencing will further enhance the potential of multi-omics studies to provide comprehensive insights into biological systems. As these technologies continue to evolve, their application in personalized medicine, environmental research, and agriculture holds great promise for addressing critical scientific challenges. In conclusion, while simultaneous extraction technologies have made significant strides, several challenges remain in optimizing extraction efficiency, ensuring reproducibility, and reducing costs. Future research should focus on refining extraction protocols, developing innovative extraction reagents, and expanding the scope of these methods to cater to a broader range of biological samples. Ultimately, the continued integration of these advanced techniques will revolutionize the way biological samples are prepared, analyzed, and understood in the context of multi-omics research.
4.Application and Prospects of Simultaneous Multicomponent Extraction Technology in Biological Samples
Kun-Peng ZHANG ; Zi-Hong YE ; Zhi-Chao XUE
Progress in Biochemistry and Biophysics 2026;53(5):1400-1414
With the rapid development of the biopharmaceutical field, the efficient and simultaneous extraction of multiple biological components from biological samples has become a critical process for advancing scientific research. The ability to simultaneously extract various molecular components such as metabolites, DNA, RNA, and proteins is pivotal for multi-omics studies, which aim to comprehensively understand the molecular mechanisms of biological systems. Traditional methods often extract these components separately, leading to challenges such as sample loss, time consumption, contamination, and inconsistencies across different data types. In contrast, simultaneous extraction techniques address these issues by maintaining the consistency of each biological component’s physiological state, improving data reliability and facilitating integration across omic platforms. This review systematically summarizes recent advances in simultaneous extraction technologies, focusing on methods such as methanol/chloroform extraction, TRIzol reagent extraction, and modified Folch extraction, which have shown significant promise in improving the efficiency and integrity of biological sample preparation. These methods offer various advantages, such as reduced sample volume requirements, decreased contamination risk, and enhanced extraction consistency, which are crucial for studies involving small sample sizes or precious clinical specimens. Among these, methanol/chloroform extraction stands out for its simplicity, low cost, and ability to extract a wide range of biological molecules. However, it does face limitations, such as its inefficiency in extracting lipids and potential RNA contamination. On the other hand, the TRIzol reagent method has become a widely adopted technique due to its ability to simultaneously isolate RNA, proteins, and metabolites from the same sample. Despite its effectiveness, the TRIzol method has limitations in RNA quality, especially when handling complex samples or those with high protein content. Modified Folch extraction, which combines liquid-liquid extraction with commercial kits, offers a highly efficient way to extract polar metabolites, lipids, RNA, DNA, and proteins from small tissue samples. This method has proven advantageous in terms of extraction yield, especially for challenging or rare samples, although it requires precise handling to avoid cross-contamination between phases. The integration of automated platforms, microfluidics, and high-throughput systems is another exciting avenue for improving simultaneous extraction. Automation facilitates large-scale, reproducible sample processing with minimal human error, while microfluidics provides high precision in sample handling and enables real-time monitoring of extraction efficiency. These innovations not only enhance the speed and reproducibility of sample preparation but also open new possibilities for single-cell analysis, where sample volumes are often limited, and extraction efficiency is critical. In addition to the technical aspects, the review also highlights the importance of optimizing extraction protocols for specific sample types, such as clinical tissues, plants, and microorganisms. For example, the challenge of extracting multiple components from cancer tissues, where sample degradation and contamination risks are high, can be mitigated by carefully selecting extraction reagents and minimizing sample handling steps. Similarly, in plant studies, where metabolite diversity is vast, the simultaneous extraction methods must be optimized to account for the unique composition of plant tissues, which often include complex secondary metabolites and cell wall components. Looking forward, the development of more efficient and standardized simultaneous extraction methods will be crucial for advancing multi-omics research. There is a growing need for protocols that can be tailored to specific research needs, ensuring both reproducibility and flexibility in diverse applications. Additionally, combining these extraction methods with high-resolution analytical techniques such as mass spectrometry and next-generation sequencing will further enhance the potential of multi-omics studies to provide comprehensive insights into biological systems. As these technologies continue to evolve, their application in personalized medicine, environmental research, and agriculture holds great promise for addressing critical scientific challenges. In conclusion, while simultaneous extraction technologies have made significant strides, several challenges remain in optimizing extraction efficiency, ensuring reproducibility, and reducing costs. Future research should focus on refining extraction protocols, developing innovative extraction reagents, and expanding the scope of these methods to cater to a broader range of biological samples. Ultimately, the continued integration of these advanced techniques will revolutionize the way biological samples are prepared, analyzed, and understood in the context of multi-omics research.
5.Enzyme-directed Immobilization Strategies for Biosensor Applications
Xing-Bao WANG ; Yao-Hong MA ; Yun-Long XUE ; Xiao-Zhen HUANG ; Yue SHAO ; Yi YU ; Bing-Lian WANG ; Qing-Ai LIU ; Li-He ZHANG ; Wei-Li GONG
Progress in Biochemistry and Biophysics 2025;52(2):374-394
Immobilized enzyme-based enzyme electrode biosensors, characterized by high sensitivity and efficiency, strong specificity, and compact size, demonstrate broad application prospects in life science research, disease diagnosis and monitoring, etc. Immobilization of enzyme is a critical step in determining the performance (stability, sensitivity, and reproducibility) of the biosensors. Random immobilization (physical adsorption, covalent cross-linking, etc.) can easily bring about problems, such as decreased enzyme activity and relatively unstable immobilization. Whereas, directional immobilization utilizing amino acid residue mutation, affinity peptide fusion, or nucleotide-specific binding to restrict the orientation of the enzymes provides new possibilities to solve the problems caused by random immobilization. In this paper, the principles, advantages and disadvantages and the application progress of enzyme electrode biosensors of different directional immobilization strategies for enzyme molecular sensing elements by specific amino acids (lysine, histidine, cysteine, unnatural amino acid) with functional groups introduced based on site-specific mutation, affinity peptides (gold binding peptides, carbon binding peptides, carbohydrate binding domains) fused through genetic engineering, and specific binding between nucleotides and target enzymes (proteins) were reviewed, and the application fields, advantages and limitations of various immobilized enzyme interface characterization techniques were discussed, hoping to provide theoretical and technical guidance for the creation of high-performance enzyme sensing elements and the manufacture of enzyme electrode sensors.
6.A Fitting Method for Photoacoustic Pump-probe Imaging Based on Phase Correction
Zhuo-Jun XIE ; Hong-Wen ZHONG ; Run-Xiang LIU ; Bo WANG ; Ping XUE ; Bin HE
Progress in Biochemistry and Biophysics 2025;52(2):525-532
ObjectivePhotoacoustic pump-probe imaging can effectively eliminate the interference of blood background signal in traditional photoacoustic imaging, and realize the imaging of weak phosphorescence molecules and their triplet lifetimes in deep tissues. However, background differential noise in photoacoustic pump-probe imaging often leads to large fitting results of phosphorescent molecule concentration and triplet lifetime. Therefore, this paper proposes a novel triplet lifetime fitting method for photoacoustic pump-probe imaging. By extracting the phase of the triplet differential signal and the background noise, the fitting bias caused by the background noise can be effectively corrected. MethodsThe advantages and feasibility of the proposed algorithm are verified by numerical simulation, phantom and in vivo experiments, respectively. ResultsIn the numerical simulation, under the condition of noise intensity being 10% of the signal amplitude, the new method can optimize the fitting deviation from 48.5% to about 5%, and has a higher exclusion coefficient (0.88>0.79), which greatly improves the fitting accuracy. The high specificity imaging ability of photoacoustic pump imaging for phosphorescent molecules has been demonstrated by phantom experiments. In vivo experiments have verified the feasibility of the new fitting method proposed in this paper for fitting phosphoometric lifetime to monitor oxygen partial pressure content during photodynamic therapy of tumors in nude mice. ConclusionThis work will play an important role in promoting the application of photoacoustic pump-probe imaging in biomedicine.
7.Controllability Analysis of Structural Brain Networks in Young Smokers
Jing-Jing DING ; Fang DONG ; Hong-De WANG ; Kai YUAN ; Yong-Xin CHENG ; Juan WANG ; Yu-Xin MA ; Ting XUE ; Da-Hua YU
Progress in Biochemistry and Biophysics 2025;52(1):182-193
ObjectiveThe controllability changes of structural brain network were explored based on the control and brain network theory in young smokers, this may reveal that the controllability indicators can serve as a powerful factor to predict the sleep status in young smokers. MethodsFifty young smokers and 51 healthy controls from Inner Mongolia University of Science and Technology were enrolled. Diffusion tensor imaging (DTI) was used to construct structural brain network based on fractional anisotropy (FA) weight matrix. According to the control and brain network theory, the average controllability and the modal controllability were calculated. Two-sample t-test was used to compare the differences between the groups and Pearson correlation analysis to examine the correlation between significant average controllability and modal controllability with Fagerström Test of Nicotine Dependence (FTND) in young smokers. The nodes with the controllability score in the top 10% were selected as the super-controllers. Finally, we used BP neural network to predict the Pittsburgh Sleep Quality Index (PSQI) in young smokers. ResultsThe average controllability of dorsolateral superior frontal gyrus, supplementary motor area, lenticular nucleus putamen, and lenticular nucleus pallidum, and the modal controllability of orbital inferior frontal gyrus, supplementary motor area, gyrus rectus, and posterior cingulate gyrus in the young smokers’ group, were all significantly different from those of the healthy controls group (P<0.05). The average controllability of the right supplementary motor area (SMA.R) in the young smokers group was positively correlated with FTND (r=0.393 0, P=0.004 8), while modal controllability was negatively correlated with FTND (r=-0.330 1, P=0.019 2). ConclusionThe controllability of structural brain network in young smokers is abnormal. which may serve as an indicator to predict sleep condition. It may provide the imaging evidence for evaluating the cognitive function impairment in young smokers.
8.Internal tension relieving technique assisted anterior cruciate ligament reconstruction to promote ligamentization of Achilles tendon grafts in small ear pigs in southern Yunnan province
Bohan XIONG ; Guoliang WANG ; Yang YU ; Wenqiang XUE ; Hong YU ; Jinrui LIU ; Zhaohui RUAN ; Yajuan LI ; Haolong LIU ; Kaiyan DONG ; Dan LONG ; Zhao CHEN
Chinese Journal of Tissue Engineering Research 2025;29(4):713-720
BACKGROUND:We have successfully established an animal model of small ear pig in southern Yunnan province with internal tension relieving technique combined with autologous Achilles tendon for anterior cruciate ligament reconstruction,and verified the stability and reliability of the model.However,whether internal tension relieving technique can promote the ligamentalization process of autologous Achilles tendon graft has not been studied. OBJECTIVE:To investigate the differences in the process of ligamentalization between conventional reconstruction and internal reduction reconstruction of the anterior cruciate ligament by gross view,histology and electron microscopy. METHODS:Thirty adult female small ear pigs in southern Yunnan province were selected.Anterior cruciate ligament reconstruction was performed on the left knee joint with the ipsilateral knee Achilles tendon(n=30 in the normal group),and anterior cruciate ligament reconstruction was performed on the right knee joint with the ipsilateral knee Achilles tendon combined with the internal relaxation and enhancement system(n=30 in the relaxation group).The autogenous right forelimb was used as the control group;the anterior cruciate ligament was exposed but not severed or surgically treated.At 12,24,and 48 weeks after surgery,10 animals were sacrificed,respectively.The left and right knee joint specimens were taken for gross morphological observation to evaluate the graft morphology.MAS score was used to evaluate the excellent and good rate of the ligament at each time point.Hematoxylin-eosin staining was used to evaluate the degree of ligament graft vascularization.Collagen fibers and nuclear morphology were observed,and nuclear morphology was scored.Ultrastructural remodeling was evaluated by scanning electron microscopy and transmission electron microscopy. RESULTS AND CONCLUSION:(1)The ligament healing shape of the relaxation group was better at various time points after surgery,and the excellent and good rate of MAS score was higher(P<0.05).Moreover,the relaxation group could obtain higher ligament vascularization score(P<0.05).(2)The arrangement of collagen bundles and fiber bundles in the two groups gradually tended to be orderly,and the transverse fiber connections between collagen gradually increased and thickened,suggesting that the strength and shape degree of the grafts were gradually improved,but the ligament remodeling in the relaxation group was always faster than that in the normal group at various time points after surgery.(3)The diameter,distribution density,and arrangement degree of collagen fibers in the relaxation group were better than those in the normal group at all time points,especially in the comparison of collagen fiber diameter between and within the relaxation group(P<0.05).
9.Mechanism of Feibi prescription on mitochondrial apoptosis of alveolar epithelial cells in mice with pulmonary fibrosis
Xue CHENG ; Huanxi JING ; Yunke ZHANG ; Hong FANG
Chinese Journal of Tissue Engineering Research 2025;29(11):2334-2339
BACKGROUND:Studies have shown that mitochondrial apoptosis of alveolar epithelial cells plays an important role in the pathogenesis of pulmonary fibrosis,and Feibi prescription can attenuate pulmonary fibrosis and inhibit the transformation of extracellular mechanisms in mice with pulmonary fibrosis. OBJECTIVE:To investigate the mechanism of Feibi prescription on mitochondrial apoptpsis of alveolar epithelial cells in bleomycin induced pulmonary fibrosis mice. METHODS:Forty male C57BL/6 mice were randomly divided into blank control group,model group,pirfenidone group,and Feibi prescription group.There were 10 mice in each group.Except for the blank control group,the other three groups were intraperitoneally injected with bleomycin(7.5 mg/kg per day)for 10 continuous days to establish the model of pulmonary fibrosis.On day 1 after modeling,the mice in corresponding drug groups were intragastrically administered with pirfenidone(51.43 mg/kg per day)or Feibi prescription(12.86 mg/kg per day).Drug administration lasted for 28 days.Then,morphological changes of lung tissue in mice were observed by hematoxylin-eosin staining and Masson staining.The levels of interleukin-1,interleukin-6,interleukin-17,and interleukin-37 in the serum were detected by ELISA,and the expression of Bax,Bcl-2,Beclin-1,and Caspase3 in the lung tissue was detected by western blot assay. RESULTS AND CONCLUSION:Morphological observation of lung tissue showed that in the model group,the alveolar septum and alveolar lumen were infiltrated with a large number of inflammatory cells,and there were large clusters of fibrous foci;in the pirfenidone group,alveolar septa were thickened,with a small infiltration of inflammatory cells and the appearance of pulmonary fibrous foci;in the Feibi prescription group,the alveolar structure was widened,with a small amount of inflammatory cell infiltration,and the alveolar structure was almost not obviously damaged,with a small number of lung fibrous foci.Compared with the blank control group,the mass concentrations of interleukin-1,interleukin-6,interleukin-17,and interleukin-37 were significantly higher in the model group(P<0.01),while the levels were significantly lower in the two drug groups than the model group(P<0.01).Moreover,the mass concentrations of interleukin-1,interleukin-6,interleukin-17,and interleukin-37 in the Feibi prescription group were lower than those in the pirfenidone group.Compared with the blank control group,the expression of Bax and Caspase3 proteins in the lung tissue of mice was significantly higher in the model group,while the expression of Bax and Caspase3 proteins was significantly lower in the two drug groups than the model group.Compared with the blank control group,the expression of Bcl-2 and Beclin-1 proteins in the lung tissue of mice was significantly lower in the model group,while the expression of Bcl-2 and Beclin-1 proteins was significantly higher in the two drug groups than the model group.To conclude,Feibi prescription can reduce pulmonary fibrosis and its mechanism may be related to the downregulation of interleukin-1,interleukin-6,interleukin-17,and interleukin-37 levels.This prescription can also reduce the apoptosis of alveolar epithelial cells by regulating mitochondrial apoptosis-related proteins,Bax,Bcl-2,Beclin-1 and Caspase3.
10.Usefulness of intraoperative choledochoscopy in laparoscopic subtotal cholecystectomy for severe cholecystitis
Rui-Hui ZHANG ; Xiang-Nan WANG ; Yue-Feng MA ; Xue-Qian TANG ; Mei-Ju LIN ; Li-Jun SHI ; Jing-Yi LI ; Hong-Wei ZHANG
Annals of Hepato-Biliary-Pancreatic Surgery 2025;29(2):192-198
Laparoscopic subtotal cholecystectomy (LSC) has been a safe and viable alternative to conversion to laparotomy in cases of severe cholecystitis. The objective of this study is to determine the utility of intraoperative choledochoscopy in LSC for the exploration of the gallbladder, cyst duct, and subsequent stone clearance of the cystic duct in cases of severe cholecystitis. A total of 72 patients diagnosed with severe cholecystitis received choledochoscopy-assisted laparoscopic subtotal cholecystectomy (CALSC). A choledochoscopy was performed to explore the gallbladder cavity and/or cystic duct, and to extract stones using a range of techniques. The clinical records, including the operative records and outcomes, were subjected to analysis. No LSC was converted to open surgery, and no bile duct or vascular injuries were sustained. All stones within the cystic duct were removed by a combination of techniques, including high-frequency needle knife electrotomy, basket, and electrohydraulic lithotripsy. A follow-up examination revealed the absence of residual bile duct stones, with the exception of one common bile duct stone, which was extracted via endoscopic retrograde cholangiopancreatography. In certain special cases, CALSC may prove to be an efficacious treatment for the management of severe cholecystitis. This technique allows for optimal comprehension of the situation within the gallbladder cavity and cystic duct, facilitating the removal of stones from the cystic duct and reducing the residue of the non-functional gallbladder remnant.

Result Analysis
Print
Save
E-mail