1.Optimization of Processing Technology of Calcined Pyritum Based on QbD Concept and Its XRD Fingerprint Analysis
Xin CHEN ; Jingwei ZHOU ; Haiying GOU ; Lei ZHONG ; Tianxing HE ; Wenbo FEI ; Jialiang ZOU ; Yue YANG ; Dewen ZENG ; Lin CHEN ; Hongping CHEN ; Shilin CHEN ; Yuan HU ; Youping LIU
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(13):197-205
ObjectiveBased on the concept of quality by design(QbD), the processing process of calcined Pyritum was optimized, and its X-ray diffraction(XRD) fingerprint was established. MethodsThe safety, effectiveness and quality controllability of calcined Pyritum were taken as the quality profile(QTPP), the color, hardness, metallic luster, phase composition, the contents of heavy metals and hazardous elements were taken as the critical quality attributes(CQAs), and the calcination temperature, calcination time, paving thickness and particle size were determined as the critical process parameters(CPPs). Differential thermal analysis, X-ray diffraction(XRD) and inductively coupled plasma mass spectrometry(ICP-MS) were used to analyze the correlation between the calcination temperature and CQAs of calcined Pyritum. Then, based on the criteria importance through intercriteria correlation(CRITIC)-entropy weight method, the optimal processing process of calcined Pyritum was optimized by orthogonal test. Powder XRD was used to analyze the phase of calcined Pyritum samples processed according to the best process, and the mean and median maps of calcined Pyritum were established by the superposition of geometric topological figures, and similarity evaluation and cluster analysis were carried out. ResultsThe results of single factor experiments showed that the physical phase of Pyritum changed from FeS2 to Fe7S8 during the process of temperature increase, the color gradually deepened from dark yellow, and the contents of heavy metals and harmful elements decreased. The optimized processing process of calcined Pyritum was as follows:calcination temperature at 750 ℃, calcination time of 2.5 h, paving thickness of 3 cm, particle size of 0.8-1.2 cm, vinegar quenching 1 time[Pyritum-vinegar(10∶3)]. After calcination, the internal structure of Pyritum was honeycomb-shaped, which was conducive to the dissolution of active ingredients. XRD fingerprints of 13 batches of calcined Pyritum characterized by 10 common peaks were established. The similarities of the relative peak intensities of the XRD fingerprints of the analyzed samples were>0.96, and it could effectively distinguish the raw products and unqualified products. ConclusionTemperature is the main factor affecting the quality of calcined Pyritum. After processing, the dissolution of the effective components in Pyritum increases, and the contents of heavy metals and harmful substances decrease, reflecting the function of processing to increase efficiency and reduce toxicity. The optimized processing process is stable and feasible, and the established XRD fingerprint can be used as one of the quality control standards of calcined Pyritum.
2.Optimization of Processing Technology of Calcined Pyritum Based on QbD Concept and Its XRD Fingerprint Analysis
Xin CHEN ; Jingwei ZHOU ; Haiying GOU ; Lei ZHONG ; Tianxing HE ; Wenbo FEI ; Jialiang ZOU ; Yue YANG ; Dewen ZENG ; Lin CHEN ; Hongping CHEN ; Shilin CHEN ; Yuan HU ; Youping LIU
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(13):197-205
ObjectiveBased on the concept of quality by design(QbD), the processing process of calcined Pyritum was optimized, and its X-ray diffraction(XRD) fingerprint was established. MethodsThe safety, effectiveness and quality controllability of calcined Pyritum were taken as the quality profile(QTPP), the color, hardness, metallic luster, phase composition, the contents of heavy metals and hazardous elements were taken as the critical quality attributes(CQAs), and the calcination temperature, calcination time, paving thickness and particle size were determined as the critical process parameters(CPPs). Differential thermal analysis, X-ray diffraction(XRD) and inductively coupled plasma mass spectrometry(ICP-MS) were used to analyze the correlation between the calcination temperature and CQAs of calcined Pyritum. Then, based on the criteria importance through intercriteria correlation(CRITIC)-entropy weight method, the optimal processing process of calcined Pyritum was optimized by orthogonal test. Powder XRD was used to analyze the phase of calcined Pyritum samples processed according to the best process, and the mean and median maps of calcined Pyritum were established by the superposition of geometric topological figures, and similarity evaluation and cluster analysis were carried out. ResultsThe results of single factor experiments showed that the physical phase of Pyritum changed from FeS2 to Fe7S8 during the process of temperature increase, the color gradually deepened from dark yellow, and the contents of heavy metals and harmful elements decreased. The optimized processing process of calcined Pyritum was as follows:calcination temperature at 750 ℃, calcination time of 2.5 h, paving thickness of 3 cm, particle size of 0.8-1.2 cm, vinegar quenching 1 time[Pyritum-vinegar(10∶3)]. After calcination, the internal structure of Pyritum was honeycomb-shaped, which was conducive to the dissolution of active ingredients. XRD fingerprints of 13 batches of calcined Pyritum characterized by 10 common peaks were established. The similarities of the relative peak intensities of the XRD fingerprints of the analyzed samples were>0.96, and it could effectively distinguish the raw products and unqualified products. ConclusionTemperature is the main factor affecting the quality of calcined Pyritum. After processing, the dissolution of the effective components in Pyritum increases, and the contents of heavy metals and harmful substances decrease, reflecting the function of processing to increase efficiency and reduce toxicity. The optimized processing process is stable and feasible, and the established XRD fingerprint can be used as one of the quality control standards of calcined Pyritum.
3.Effectiveness of additional anti-rotation steel plate assisted intramedullary nail technology in aseptic femoral non-union.
Wei WANG ; Miaomiao YANG ; Xiaowen DENG ; Fan LI ; Wenbo LI ; Weiwei SHEN ; Peisheng SHI ; Jie SHI ; Chuangbing LI ; Yun XUE ; Qiuming GAO
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(9):1170-1174
OBJECTIVE:
To explore the effectiveness of additional anti-rotation steel plate assisted intramedullary nail technology in treatment of aseptic femoral non-union patients.
METHODS:
A retrospective analysis was conducted on 21 patients with aseptic femoral non-union who admitted between September 2020 and October 2024 and treated with additional anti-rotation steel plate assisted intramedullary nail technology. There were 17 males and 4 females, aged 25-67 years (mean, 44 years). There were 19 cases of femoral anterograde intramedullary nail fixation, 1 case of femoral retrograde intramedullary nail fixation, and 1 case of steel plate fixation with fatigue fracture. There were 9 cases of hypertrophic non-union and 12 cases of atrophic non-union. All patients had varying degrees of fracture end atrophy/sclerosis. Among them, 20 patients who were fixed with intramedullary nails underwent removal of soft tissue and hardened bone at the fracture end, and cortical treatment resulted in the appearance of "chili sign" at the fracture end. Iliac bone grafting and anti-rotation steel plate fixation were performed. One patient with steel plate fixation was removed the steel palte and fixed with a retrograde intramedullary nail, while the hardened bone at the fracture end was removed, iliac bone grafting and anti-rotation steel plate fixation were performed. Postoperative follow-up observation included the incision healing, maximum knee flexion range of motion, bone healing, length of lower limbs, and subjective satisfaction. The lower extremity functional scale (LEFS) score was used to evaluate the lower limb function.
RESULTS:
All incisions healed by first intention. All patients were followed up 7-26 months (mean, 15.5 months). At last follow-up, the femoral fracture healed with the obvious callus formation at the fracture end; the maximum knee flexion range of motion was 95°-127° (mean, 112.67°). The LEFS score increased from 29.9±6.7 before operation to 75.9±3.0 at last follow-up, and the difference was significant (t=-29.622, P<0.001). Except for 1 patient who underwent intramedullary nail dynamic treatment before operation and had a lower limb shortening of about 0.9 cm, the other patients had bilateral lower limbs of equal length. All patients had no postoperative infections, mal-union of fractures, deep vein thrombosis, joint stiffness, or other complications.
CONCLUSION
The use of additional anti-rotation steel plate assisted intramedullary nail technology in the treatment of aseptic femoral non-union not only overcomes the drawbacks of insufficient stability at the fracture end of intramedullary nails, but also overcomes the shortcomings of biased fixation with steel plates. It has the advantages of minimal trauma, effective maintenance of fracture stability, and ideal postoperative functional recovery, making it an effective treatment for aseptic femoral non-union.
Humans
;
Male
;
Fracture Fixation, Intramedullary/instrumentation*
;
Female
;
Bone Plates
;
Middle Aged
;
Adult
;
Femoral Fractures/surgery*
;
Retrospective Studies
;
Bone Nails
;
Aged
;
Fractures, Ununited/surgery*
;
Treatment Outcome
;
Bone Transplantation/methods*
;
Steel
;
Fracture Healing
4.Renal autotransplantation for the treatment of complex renal aneurysm in a child: A case report.
Lei YU ; Wenbo YANG ; Yufan YANG ; Qiang WANG
Journal of Peking University(Health Sciences) 2025;57(2):396-399
Renal autotransplantation (RA) offers significant technical advantages for the management of certain complex renal vascular diseases, such as complex renal aneurysms and renal artery malformations. This report describes a case of a 5-year-old child with a complex left renal artery aneurysm combined with multiple aneurysms. The child was admitted to Peking University People's Hospital in December 2023 due to a one-year history of intermittent abdominal pain, with an abdominal mass detected in the past month. Computed tomography angiography(CTA) revealed multiple vascular anomalies, including: (1) a left renal artery aneurysm, (2) an abdominal aortic aneurysm, and (3) a right iliac artery aneurysm. After a comprehensive evaluation of these findings, the surgical team developed a treatment plan that involved the excision of the left renal artery aneurysm, autotransplantation of the left kidney, and resection of the abdominal aortic aneurysm with an artificial vascular catheterization. During surgery, it was discovered that the left renal artery anatomy was highly complex. The artery had two primary branches, along with an additional polar artery located at the lower pole. The aneurysm was identified at the distal end of the renal artery trunk, with a pronounced bulging at the intersection between the main renal artery trunk and its secondary branches. Due to these structural complexities, the team decided to use an ex vivo surgical approach to repair the aneurysm. Ex vivo repair involves temporarily removing the kidney from the body to repair the renal artery aneurysm with enhanced precision, enabling the surgical team to meticulously reconstruct the complex vascular architecture without the constraints of in vivo manipulation. The ex vivo repair of the renal artery aneurysm was successful, allowing for accurate vascular reconstruction and avoiding potential intraoperative complications. Following the reconstruction, the kidney was autotransplanted back into the child's body, and blood flow was effectively restored to the organ. The therapeutic outcome was excellent, with the child experiencing no postoperative complications. The patient recovered well and was discharged from the hospital in stable condition. This case underscores the value of renal autotransplantation combined with ex vivo repair for pediatric patients with complicated renal artery aneurysms. Through this report, we aim to provide insights and considerations for the surgical treatment of similar cases in children with complex renal vascular anatomy.
Child, Preschool
;
Humans
;
Aneurysm/surgery*
;
Aortic Aneurysm, Abdominal/diagnostic imaging*
;
Computed Tomography Angiography
;
Iliac Aneurysm/surgery*
;
Kidney Transplantation/methods*
;
Renal Artery/abnormalities*
;
Transplantation, Autologous
5.A rapid method for detecting prfA and hly toxin genes of Listeria monocytogenes using double nucleic acid colloidal gold strips.
Yan LIU ; Jianyu YANG ; Yujiao ZHOU ; Wenbo DING ; Xianyu ZHANG ; Linran GAO ; Beizhen PAN ; Jifei YANG ; Yundong ZHAO
Journal of Southern Medical University 2025;45(2):387-394
OBJECTIVES:
To detect prfA and hly toxin genes of Listeria monocytogenes using polymerase chain reaction (PCR) and colloidal gold technology.
METHODS:
L. monocytogenes DNA was extracted by boiling method. With prfA and hly of L. monocytogenes as the target genes, the 5' ends of upstream and downstream primers of prfA gene were labeled with 6-FAM and biotin, and the 5' ends of upstream and downstream primers of hly gene were labeled with digoxin and biotin, respectively, to establish the toxin gene detection method. Using cloning transformation, sequencing analysis, cloning of positive control products, the detection kid was developed and its specificity, sensitivity, reproducibility and stability were tested, followed by verification with sample testing.
RESULTS:
The concentration of L. monocytogenes DNA extracted by boiling method was 148.81±0.97 ng/μL, and the A260/A280 ratio ranged from 1.8 to 2.0. The PCR products showed a 100% homology with the gene sequences in GenBank database after cloning, transformation and sequencing. The colloidal gold strip yielded positive results only for L. monocytogenes samples without cross-reactions with Staphylococcus aureus, Escherichia coli or Bacillus cereus, and its minimum detection limit was 10-2 ng/μL, demonstrating a 10-fold greater sensitivity of the test than agarose gel electrophoresis. The test also showed good reproducibility of the results when performed by different operators with good stability of the test strips after storage for 6 to 12 months. The test results showed that this kit could accurately and quickly detect L.monocytogenes in the test samples.
CONCLUSIONS
The detection kit developed in this study can simultaneously detect prfA and hly toxin genes of L. monocytogenes with good specificity, sensitivity, reproducibility and stability for use in food safety inspection.
Listeria monocytogenes/isolation & purification*
;
Gold Colloid
;
Bacterial Toxins/genetics*
;
Polymerase Chain Reaction/methods*
;
Hemolysin Proteins/genetics*
;
Bacterial Proteins/genetics*
;
DNA, Bacterial/genetics*
;
Food Microbiology
;
Heat-Shock Proteins
6.Development of Core Outcome Set for Clinical Effectiveness Trials of Heart Failure with Preserved Ejection Fraction
Yongcheng LIU ; Yujiao SHI ; Siyu LIU ; Chenguang YANG ; Wenbo QIAO ; Xiaoyu LIANG ; He ZHANG ; Lizhi LI ; Guoju DONG
World Science and Technology-Modernization of Traditional Chinese Medicine 2025;27(5):1335-1342
Objective To develop a core outcome set(COS)for clinical effectiveness trials of heart failure with preserved ejection fraction(HFpEF).Methods Outcome measures were collected through database literatures search,clinical experts questionnaire survey and semi-structured patients interview.Then,the outcome measures pool was constructed and domains were divided.Candidate outcome measures of COS were screened through two rounds of Delphi survey.Finally,a consensus meeting was held to determine COS and reach a consensus.Results A total of 317 outcome measures which could be divided into 6 domains were collected through literature research,questionnaire survey and semi-structured interview.15 candidate outcome measures of COS were screened through two rounds of Delphi survey.Finally,the consensus meeting reached consensus on a COS with 6 entries.Conclusion In this study,a COS for clinical effectiveness trials of HFpEF was developed,which is conducive to the standardization of efficacy evaluation.
7.Surgical strategies of contracted nose correction
Weiliang ZENG ; Xiancheng WANG ; Yang SUN ; Xiang XIONG ; Xianxi MENG ; Wenbo LI ; Zhongjie YI ; Zhihua QIAO
Chinese Journal of Plastic Surgery 2025;41(8):781-788
Objective:To evaluate the treatment strategies and outcomes for contracted nasal deformity.Methods:A retrospective review was conducted of the patients with contracted noses who underwent surgery at the Department of Plastic and Aesthetic Surgery, the Second Xiangya Hospital of Central South University, between January 2021 and January 2024. Based on the pathologic-anatomic features and severity of the deformity, patients were categorized as having mild, moderate or severe contraction. Mild cases received extensive subcutaneous dissection and framework reconstruction with various grafts. Moderate cases underwent preoperative nasal-skin distraction and intra-operative reconstruction with lower lateral or septal cartilage. Severe cases, in addition to reconstruction of the lower lateral cartilage and nasal septum, underwent individualized repair, including mucosal or cutaneous defect resurfacing. Postoperative follow-up assessed nasal appearance, complications and recurrence of contraction. Nasal aesthetics were quantified with visual analogue scale (VAS, 0-10 points; higher scores = less deformity), and patient satisfaction with the rhinoplasty outcome evaluation (ROE) questionnaire (0 = very dissatisfied, 100 = very satisfied) before surgery and at final follow-up. Paired t-test was used for VAS and ROE comparisons; categorical variables were analyzed with the χ2 test. A P-value < 0.05 denoted statistical significance. Results:A total of 96 patients were included, comprising 7 males and 89 females, aged (27.4 ± 8.0) years (19-58 years). There were 64 cases of mild, 19 cases of moderate, and 13 cases of severe contracted nose deformities. Postoperative follow-up(14.0 ± 4.6) months (6-19 months). No cases of abnormal nasal appearance, infection, necrosis, scar hyperplasia, or recurrence of contracted nose were observed during follow-up. Significant improvements in nasal aesthetic outcomes were observed. The VAS scores for mild, moderate, and severe contracted noses increased significantly from preoperative values of 4.7 ± 1.0, 3.0 ± 1.2, and 2.2± 1.1 to postoperative values of 8.6 ± 0.7, 8.9 ± 0.7, and 8.2 ± 0.9, respectively (all P < 0.01). Similarly, the ROE scores improved significantly from 59.1 ± 10.0, 34.2 ± 12.1, and 28.5± 6.3 preoperatively to 90.2 ± 9.5, 91.5 ± 7.5, and 93.3 ± 5.8 postoperatively (all P < 0.01). Conclusion:Selecting appropriate surgical methods based on the pathological and anatomical characteristics and severity of contracted nose deformities can achieve favorable outcomes. Postoperative nasal aesthetic appearance is significantly improved, and patient satisfaction is high.
8.Study on the Effectiveness and Safety of Linggui Qihua No.2 Prescription in Treating Heart Failure with Preserved Ejection Fraction
Siyu LIU ; Wenbo QIAO ; Xiaoyu LIANG ; Yujiao SHI ; Yongcheng LIU ; Chenguang YANG ; Guoju DONG
Chinese Journal of Information on Traditional Chinese Medicine 2025;32(6):167-172
Objective To investigate the efficacy and safety of Linggui Qihua No.2 Prescription(LGQH2)in patients with heart failure with preserved ejection fraction(HFpEF).Methods Totally 60 HFpEF patients were randomly divided into experimental group and control group according to random number table method,with 30 patients in each group.On the basis of standardized treatment for heart failure,the experimental group was given LGQH2 granules,13 g/time,twice a day,orally;the control group was given placebo granules of LGQH2,with the same administration method as the experimental group.The treatment course for both groups was 4 weeks.6-minute walking distance(6MWD),Kansas City Cardiomyopathy Questionnaire(KCCQ)score,TCM syndrome score and serum NT-proBNP levels.Echocardiography was used to detect the ratio of early diastolic blood flow velocity(E)at the mitral valve to early diastolic myocardial motion velocity(e')at the mitral annulus,left atrial diameter(LAD),left ventricular end-diastolic diameter(LVEDD)and interventricular septal thickness(IVST).Adverse reactions and events were also recorded.Results Compared with before treatment,both groups showed significant improvement in 6MWD,KCCQ score,TCM syndrome score,serum NT proBNP,and E/e'after treatment(P<0.05),and there was no statistical significance in LAD,LVEDD and IVST between the two groups(P>0.05);after treatment,the experimental group showed better improvement in 6MWD,KCCQ score,TCM syndrome score and E/e'compared to the control group(P<0.05).During the research process,neither group of patients experienced any adverse reactions or events.Conclusion LGQH2 Prescription can effectively enhance exercise tolerance and cardiac function of HFpEF patients,alleviate symptoms,improve quality of life,and inhibit diastolic dysfunction of the heart,without notable adverse reactions.
9.Development and accuracy evaluation of a photogrammetry-based extraoral scanning system for edentulous implant placement
Yongtao YANG ; Aonan WEN ; Xiangyi SHANG ; Shenyao SHAN ; Wenbo LI ; Qingzhao QIN ; Zixiang GAO ; Yujia ZHU ; Yong WANG ; Yijiao ZHAO
Chinese Journal of Stomatology 2025;60(8):863-870
Objective:To evaluate the accuracy of a self-developed extraoral scanning system based on photogrammetry technology, and to provide evidence for advancing the development and clinical application evaluation of domestically produced scanning devices.Methods:This research group developed a photogrammetry-based implant extraoral scanning system with customized scan bodies. Two distinct edentulous implant resin models were designed and three-dimensional (3D)-printed by Center of Digital Dentistry, Peking University School and Hospital of Stomatology, containing 6 (Model 1) and 8 (Model 2) abutment analogs respectively. Reference data acquisition was performed using a high-precision denture 3D scanner with scan caps mounted on the analogs. Specialized scan bodies were then mounted on the analogs for 3D positional data acquisition using both the self-developed system (experimental group) and the clinically established system (control group). Each system conducted 10 repeated scans per model. Trueness was assessed through root mean square error (RMSE), linear deviation (LD), and angular deviation (AD) relative to reference data, while precision was determined through intra-group RMSE analysis. Systematic comparisons included inter-group performance on identical models and intra-group variability across different models.Results:For Model 1, the experimental group showed statistically significant advantages over controls in intra-group RMSE [(3.10±0.71) μm vs (4.61±1.51) μm, P<0.001], reference-data RMSE [(21.48±0.60) μm vs (32.50±0.63) μm, P<0.001], linear deviation [23.64 (32.35) μm vs 44.86 (55.73) μm, P<0.001], and angular deviation [0.29° (0.29°) vs 0.23° (0.33°), P<0.001]. In Model 2, significant improvements were observed in intra-group RMSE [(4.47±1.58) μm vs (6.21±2.07) μm, P<0.001], reference-data RMSE [(38.84±0.86) μm vs (43.69±1.34) μm, P<0.001], and linear deviation [37.95 (50.68) μm vs 49.71 (58.89) μm, P<0.001]. Both groups exhibited model-dependent variability, with RMSE of precision and trueness of both groups, linear deviation of experimental group, angular deviation of control group showing statistically significant increases (all P<0.001) corresponding to abutment analog quantity. Conclusions:The self-developed scanning system demonstrates superior accuracy in 3D positional acquisition of abutment analogs compared to the contral group system, with implant number identified as a critical determinant of extraoral scanning accuracy.
10.Role and clinical application progress of exosome-derived non-coding RNA in microenvironment of osteoarthritis
Zhichao LI ; Zhenguo YANG ; Lei WANG ; Wenbo WANG ; Jingcai XUE ; Wenbin LIU ; Hui CAO
Chinese Journal of Tissue Engineering Research 2025;29(13):2784-2792
BACKGROUND:Osteoarthritis is a common degenerative joint disease,and the etiology and development of its pathogenesis are still unclear.Timely diagnosis and treatment of early osteoarthritis are crucial,and there is currently no definite and effective method.Extracellular vesicles come from a wide range of sources,including non-coding RNAs such as small RNAs,circular RNAs,and long chain non-coding RNAs.Extracellular vesicles non-coding RNAs can be directly delivered from primitive cells to neighboring or remote cells,regulating cell activity through intercellular communication and playing an important regulatory role in reshaping the bone and joint microenvironment.OBJECTIVE:To summarize the intervention effects of exosome-derived non-coding RNAs on the joint microenvironment of osteoarthritis and the progress made in clinical application,and to clarify the potential of exosome-derived non-coding RNAs in the diagnosis and treatment of osteoarthritis.METHODS:Search terms "exosomes,non-coding RNA,osteoarthritis,application,signal pathway,synovial fluid,cartilage cells,cartilage matrix,subchondral,mechanism" were used for the search on PubMed database.Finally,66 related articles were included for review analysis.RESULTS AND CONCLUSION:(1) Exosome-derived non-coding RNAs play an important regulatory role in the joint microenvironment during the pathogenesis of osteoarthritis,mainly reflected in:exosome non-coding RNAs regulating the inflammatory response in the joint,degeneration of chondrocytes and cartilage matrix,subchondral bone remodeling,and intercellular communication.(2) The non-coding RNAs in exosomes can serve as biomarkers for osteoarthritis,aiding in the early diagnosis and monitoring of disease progression and prognosis.(3) Exosome non-coding RNAs serve as therapeutic targets for osteoarthritis.Exosomes carry miRNAs to the articular chondrocytes and cartilage matrix to play a regulatory role.(4) Exosomes non-coding RNAs can improve the effect of cartilage tissue engineering by regulating gene expression and promoting intercellular communication to repair or regenerate damaged cartilage.(5) In future research,researchers should continue to explore the intervention mechanism of non-coding RNAs derived from exosomes on osteoarthritis,and apply them to clinical practice in combination with the latest research outcomes in cartilage tissue engineering,which will effectively help solve the pain of osteoarthritis patients.

Result Analysis
Print
Save
E-mail