This article reports a diagnostically and therapeutically challenging case of small intestinal marginal zone lymphoma. The patient presented with recurrent abdominal pain as the chief complaint, and imaging revealed multifocal small bowel wall thickening with high uptake, multisegmental luminal stenosis, and proximal dilation. Initial diagnostic workup, including gastroscopy, colonoscopy, and enteroscopy with biopsy, failed to establish a definitive diagnosis. Empirical anti-tuberculosis therapy was ineffective. A repeat enteroscopic biopsy performed over eight months after symptom onset eventually confirmed the diagnosis of mucosa-associated lymphoid tissue (MALT) extranodal marginal zone lymphoma. Despite three different chemotherapy regimens, the patient's intestinal obstruction symptoms persisted, with imaging still showing multifocal bowel wall thickening and hypermetabolic activity. A critical diagnostic dilemma arose regarding whether the PET/CT-positive lesions represented residual lymphoma or fibrotic scarring, whether further chemotherapy adjustments were warranted, and whether surgical resection was necessary. Multidisciplinary discussion concluded that imaging had limited discriminatory value in this scenario and that surgical intervention should be pursued if feasible. The patient successfully underwent partial small bowel resection, with postoperative pathology confirming no residual lymphoma but significant fibrotic changes. The patient has since resumed a normal diet, with body weight nearly restored to pre-illness levels. This case highlights that fibrotic transformation is a common sequela of treated marginal zone lymphoma and that PET/CT may misleadingly suggest residual disease, potentially leading to unnecessary chemotherapy. Timely surgical intervention is crucial in such scenarios.
2.Evaluation of the function and activity of masticatory muscles using a self-developed wireless surface electromyography system.
Wenbo LI ; Yujia ZHU ; Qingzhao QIN ; Shenyao SHAN ; Zixiang GAO ; Aonan WEN ; Yong WANG ; Yijiao ZHAO
West China Journal of Stomatology 2025;43(3):346-353
OBJECTIVES:
This study aimed to evaluate the repeatability and reliability of a self-developed domestic wireless surface electromyography (sEMG) system (Oralmetry) in assessing the activity of the temporalis and masseter muscles to provide theoretical support for its clinical application.
METHODS:
Twenty-two volunteers were recruited. Through multiple repeated measurements, the sEMG signals of bilateral anterior temporalis and masseter muscles during maximum voluntary clenching were collected using the self-developed sEMG device, Oralmetry, and two commercial sEMG devices (Zebris and Teethan), filtered, screened, and standardized. Seven sEMG indicators for assessing masticatory muscle function were calculated. The intraclass correlation coefficient (ICC) was used to evaluate the repeatability of the measurements from the three sEMG devices, and statistical analysis was conducted to compare the consistency of the seven sEMG indicators obtained from the devices.
RESULTS:
Among the 22 participants, the ICC values of the repeated measurements from the three sEMG devices ranged from 0.88 to 0.99. The measurements of three sEMG indicators (antero-posterior coeffificient, percentage overlapping coeffificient_MM, and percentage overlapping coeffificient_TA) obtained by Zebris were significantly different from those obtained by Oralmetry and Teethan (P<0.05). No significant differences in the measurements of the seven sEMG indicators were found between Oralmetry and Teethan.
CONCLUSIONS
Oralmetry and the two commercial sEMG devices demonstrated good repeatability in capturing sEMG indicators for evaluating masticatory muscle function. In particular, Oralmetry showed the highest ICC values. All three devices also exhibited good consistency in measuring sEMG indicators, and a high agreement was observed between the two wireless sEMG devices (Oralmetry and Teethan). These findings provide theoretical support for the clinical application of Oralmetry.
Humans
;
Electromyography/methods*
;
Masseter Muscle/physiology*
;
Masticatory Muscles/physiology*
;
Wireless Technology
;
Reproducibility of Results
;
Temporal Muscle/physiology*
;
Male
;
Adult
;
Female
;
Young Adult
3.Development and accuracy evaluation of a photogrammetry-based extraoral scanning system for edentulous implant placement
Yongtao YANG ; Aonan WEN ; Xiangyi SHANG ; Shenyao SHAN ; Wenbo LI ; Qingzhao QIN ; Zixiang GAO ; Yujia ZHU ; Yong WANG ; Yijiao ZHAO
Chinese Journal of Stomatology 2025;60(8):863-870
Objective:To evaluate the accuracy of a self-developed extraoral scanning system based on photogrammetry technology, and to provide evidence for advancing the development and clinical application evaluation of domestically produced scanning devices.Methods:This research group developed a photogrammetry-based implant extraoral scanning system with customized scan bodies. Two distinct edentulous implant resin models were designed and three-dimensional (3D)-printed by Center of Digital Dentistry, Peking University School and Hospital of Stomatology, containing 6 (Model 1) and 8 (Model 2) abutment analogs respectively. Reference data acquisition was performed using a high-precision denture 3D scanner with scan caps mounted on the analogs. Specialized scan bodies were then mounted on the analogs for 3D positional data acquisition using both the self-developed system (experimental group) and the clinically established system (control group). Each system conducted 10 repeated scans per model. Trueness was assessed through root mean square error (RMSE), linear deviation (LD), and angular deviation (AD) relative to reference data, while precision was determined through intra-group RMSE analysis. Systematic comparisons included inter-group performance on identical models and intra-group variability across different models.Results:For Model 1, the experimental group showed statistically significant advantages over controls in intra-group RMSE [(3.10±0.71) μm vs (4.61±1.51) μm, P<0.001], reference-data RMSE [(21.48±0.60) μm vs (32.50±0.63) μm, P<0.001], linear deviation [23.64 (32.35) μm vs 44.86 (55.73) μm, P<0.001], and angular deviation [0.29° (0.29°) vs 0.23° (0.33°), P<0.001]. In Model 2, significant improvements were observed in intra-group RMSE [(4.47±1.58) μm vs (6.21±2.07) μm, P<0.001], reference-data RMSE [(38.84±0.86) μm vs (43.69±1.34) μm, P<0.001], and linear deviation [37.95 (50.68) μm vs 49.71 (58.89) μm, P<0.001]. Both groups exhibited model-dependent variability, with RMSE of precision and trueness of both groups, linear deviation of experimental group, angular deviation of control group showing statistically significant increases (all P<0.001) corresponding to abutment analog quantity. Conclusions:The self-developed scanning system demonstrates superior accuracy in 3D positional acquisition of abutment analogs compared to the contral group system, with implant number identified as a critical determinant of extraoral scanning accuracy.
4.Development and accuracy evaluation of a photogrammetry-based extraoral scanning system for edentulous implant placement
Yongtao YANG ; Aonan WEN ; Xiangyi SHANG ; Shenyao SHAN ; Wenbo LI ; Qingzhao QIN ; Zixiang GAO ; Yujia ZHU ; Yong WANG ; Yijiao ZHAO
Chinese Journal of Stomatology 2025;60(8):863-870
Objective:To evaluate the accuracy of a self-developed extraoral scanning system based on photogrammetry technology, and to provide evidence for advancing the development and clinical application evaluation of domestically produced scanning devices.Methods:This research group developed a photogrammetry-based implant extraoral scanning system with customized scan bodies. Two distinct edentulous implant resin models were designed and three-dimensional (3D)-printed by Center of Digital Dentistry, Peking University School and Hospital of Stomatology, containing 6 (Model 1) and 8 (Model 2) abutment analogs respectively. Reference data acquisition was performed using a high-precision denture 3D scanner with scan caps mounted on the analogs. Specialized scan bodies were then mounted on the analogs for 3D positional data acquisition using both the self-developed system (experimental group) and the clinically established system (control group). Each system conducted 10 repeated scans per model. Trueness was assessed through root mean square error (RMSE), linear deviation (LD), and angular deviation (AD) relative to reference data, while precision was determined through intra-group RMSE analysis. Systematic comparisons included inter-group performance on identical models and intra-group variability across different models.Results:For Model 1, the experimental group showed statistically significant advantages over controls in intra-group RMSE [(3.10±0.71) μm vs (4.61±1.51) μm, P<0.001], reference-data RMSE [(21.48±0.60) μm vs (32.50±0.63) μm, P<0.001], linear deviation [23.64 (32.35) μm vs 44.86 (55.73) μm, P<0.001], and angular deviation [0.29° (0.29°) vs 0.23° (0.33°), P<0.001]. In Model 2, significant improvements were observed in intra-group RMSE [(4.47±1.58) μm vs (6.21±2.07) μm, P<0.001], reference-data RMSE [(38.84±0.86) μm vs (43.69±1.34) μm, P<0.001], and linear deviation [37.95 (50.68) μm vs 49.71 (58.89) μm, P<0.001]. Both groups exhibited model-dependent variability, with RMSE of precision and trueness of both groups, linear deviation of experimental group, angular deviation of control group showing statistically significant increases (all P<0.001) corresponding to abutment analog quantity. Conclusions:The self-developed scanning system demonstrates superior accuracy in 3D positional acquisition of abutment analogs compared to the contral group system, with implant number identified as a critical determinant of extraoral scanning accuracy.
5.Deep learning algorithms for intelligent construction of a three-dimensional maxillo-facial symmetry reference plane
Yujia ZHU ; Hua SHEN ; Aonan WEN ; Zixiang GAO ; Qingzhao QIN ; Shenyao SHAN ; Wenbo LI ; Xiangling FU ; Yijiao ZHAO ; Yong WANG
Journal of Peking University(Health Sciences) 2025;57(1):113-120
Objective:To develop an original-mirror alignment associated deep learning algorithm for intelligent registration of three-dimensional maxillofacial point cloud data,by utilizing a dynamic graph-based registration network model(maxillofacial dynamic graph registration network,MDGR-Net),and to provide a valuable reference for digital design and analysis in clinical dental applications.Methods:Four hundred clinical patients without significant deformities were recruited from Peking University School of Stomatology from October 2018 to October 2022.Through data augmentation,a total of 2 000 three-dimensional maxillofacial datasets were generated for training and testing the MDGR-Net algorithm.These were divided into a training set(1 400 cases),a validation set(200 cases),and an internal test set(200 cases).The MDGR-Net model constructed feature vectors for key points in both original and mirror point clouds(X,Y),established correspondences between key points in the X and Y point clouds based on these feature vectors,and calculated rotation and translation matrices using singular value decomposi-tion(SVD).Utilizing the MDGR-Net model,intelligent registration of the original and mirror point clouds were achieved,resulting in a combined point cloud.The principal component analysis(PCA)algorithm was applied to this combined point cloud to obtain the symmetry reference plane associated with the MDGR-Net methodology.Model evaluation for the translation and rotation matrices on the test set was performed using the coefficient of determination(R2).Angle error evaluations for the three-dimensional maxillofacial symmetry reference planes were constructed using the MDGR-Net-associated method and the"ground truth"iterative closest point(ICP)-associated method were conducted on 200 cases in the inter-nal test set and 40 cases in an external test set.Results:Based on testing with the three-dimensional maxillofacial data from the 200-case internal test set,the MDGR-Net model achieved an R2 value of 0.91 for the rotation matrix and 0.98 for the translation matrix.The average angle error on the internal and external test sets were 0.84°±0.55° and 0.58°±0.43°,respectively.The construction of the three-dimensional maxillofacial symmetry reference plane for 40 clinical cases took only 3 seconds,with the model performing optimally in the patients with skeletal Class Ⅲ malocclusion,high angle cases,and Angle Class Ⅲ orthodontic patients.Conclusion:This study proposed the MDGR-Net association method based on intelligent point cloud registration as a novel solution for constructing three-dimensional maxillo-facial symmetry reference planes in clinical dental applications,which can significantly enhance diagnos-tic and therapeutic efficiency and outcomes,while reduce expert dependence.
6.Safety and efficacy of acute stent implantation during endovascular treatment for patients with emergent large vessel occlusion due to intracranial atherosclerotic stenosis
Tian LIN ; Wanling WEN ; Juan DU ; Zheng WU ; Xiangkai KONG ; Wenbo DUAN ; Xiaoyun ZHANG ; Bin DU ; Yiling CAI ; Yongqiang CUI
Chinese Journal of Internal Medicine 2024;63(3):272-278
Objective:To investigate the efficacy and safety of acute stent implantation during endovascular treatment for patients with emergent large vessel occlusion due to intracranial atherosclerotic stenosis.Methods:A retrospective analysis was carried out on 46 patients with emergent large vessel occlusion due to intracranial atherosclerotic stenosis who received endovascular treatment at the Strategic Support Force Medical Center from January 2015 to August 2022. Twenty-seven patients underwent balloon angioplasty alone and 19 patients underwent acute stent implantation. The baseline characteristics, modified thrombolysis in cerebral infarction (mTICI) score of the responsible vessels, modified Rankin scale (mRS) score 90 days after operation, incidence of symptomatic intracranial hemorrhage and mortality of the two groups were evaluated.Results:The proportion of effective recanalization of the offending vessels (mTICI≥2b) in the acute stenting group was slightly higher than that in the balloon angioplasty group (16/19 vs. 81.5%), but the difference was not statistically significant ( P>0.05). Besides, there was no significant difference in the median of mRS between the acute stenting group [3.0(0, 4.0)] and the balloon angioplasty group [4.0(1.0, 5.0)] 90 days after operation ( P>0.05). In terms of safety, the incidence of symptomatic intracranial hemorrhage and mortality were comparable between the two groups ( P>0.05). Conclusions:The effect of acute stent implantation during endovascular treatment for patients with emergent large vessel occlusion due to intracranial atherosclerotic stenosis is not inferior to that of balloon angioplasty, and it does not increase the risk of intracranial bleeding complications.
7.Insights into Treatment of Modern Epidemic Diseases from Xiangsu Powder (香苏散) inTreatment of Cold Epidemics
Shizhe SHAN ; Bo WEN ; Wenbo SHAO ; Yanxing XUE
Journal of Traditional Chinese Medicine 2024;65(9):966-969
The prescription of Xiangsu Powder (香苏散) reflects the exquisite balance in treating both the superficial and deep layers, harmonizing the body's vital energy and blood, and addressing the functions of the triple energizer simultaneously. Its application in treating cold epidemics has been a long time, yet its importance in modern disease treatment is often overlooked. Based on the treatment principles demonstrated by Xiangsu Powder in treating cold epidemics, it is proposed that in the treatment of modern epidemic diseases, the dual principles of cold and heat should not be neglected. When cold pathogens stagnate at the surface, they should be dispersed and detoxified, using methods that induce sweating to expel them from the surface. When cold and dampness coexist, efforts should be made to regulate the flow of vital energy, blood, and body fluids to restore the proper functioning of the three burners. When cold-induced pathogenic factors are severe and toxic, aromatic herbs should be utilized to dispel turbidity and avoid contamination. Throughout the entire course of treating epidemic diseases, attention should be paid to inducing sweating without damaging the body's vital energy, while also protecting the body's righteous qi, with the aim of providing refe-rence for the treatment of modern epidemic diseases.
8.Safety of high-carbohydrate fluid diet 2 h versus overnight fasting before non-emergency endoscopic retrograde cholangiopancreatography: A single-blind, multicenter, randomized controlled trial
Wenbo MENG ; W. Joseph LEUNG ; Zhenyu WANG ; Qiyong LI ; Leida ZHANG ; Kai ZHANG ; Xuefeng WANG ; Meng WANG ; Qi WANG ; Yingmei SHAO ; Jijun ZHANG ; Ping YUE ; Lei ZHANG ; Kexiang ZHU ; Xiaoliang ZHU ; Hui ZHANG ; Senlin HOU ; Kailin CAI ; Hao SUN ; Ping XUE ; Wei LIU ; Haiping WANG ; Li ZHANG ; Songming DING ; Zhiqing YANG ; Ming ZHANG ; Hao WENG ; Qingyuan WU ; Bendong CHEN ; Tiemin JIANG ; Yingkai WANG ; Lichao ZHANG ; Ke WU ; Xue YANG ; Zilong WEN ; Chun LIU ; Long MIAO ; Zhengfeng WANG ; Jiajia LI ; Xiaowen YAN ; Fangzhao WANG ; Lingen ZHANG ; Mingzhen BAI ; Ningning MI ; Xianzhuo ZHANG ; Wence ZHOU ; Jinqiu YUAN ; Azumi SUZUKI ; Kiyohito TANAKA ; Jiankang LIU ; Ula NUR ; Elisabete WEIDERPASS ; Xun LI
Chinese Medical Journal 2024;137(12):1437-1446
Background::Although overnight fasting is recommended prior to endoscopic retrograde cholangiopancreatography (ERCP), the benefits and safety of high-carbohydrate fluid diet (CFD) intake 2 h before ERCP remain unclear. This study aimed to analyze whether high-CFD intake 2 h before ERCP can be safe and accelerate patients’ recovery.Methods::This prospective, multicenter, randomized controlled trial involved 15 tertiary ERCP centers. A total of 1330 patients were randomized into CFD group ( n = 665) and fasting group ( n = 665). The CFD group received 400 mL of maltodextrin orally 2 h before ERCP, while the control group abstained from food/water overnight (>6 h) before ERCP. All ERCP procedures were performed using deep sedation with intravenous propofol. The investigators were blinded but not the patients. The primary outcomes included postoperative fatigue and abdominal pain score, and the secondary outcomes included complications and changes in metabolic indicators. The outcomes were analyzed according to a modified intention-to-treat principle. Results::The post-ERCP fatigue scores were significantly lower at 4 h (4.1 ± 2.6 vs. 4.8 ± 2.8, t = 4.23, P <0.001) and 20 h (2.4 ± 2.1 vs. 3.4 ± 2.4, t= 7.94, P <0.001) in the CFD group, with least-squares mean differences of 0.48 (95% confidence interval [CI]: 0.26–0.71, P <0.001) and 0.76 (95% CI: 0.57–0.95, P <0.001), respectively. The 4-h pain scores (2.1 ± 1.7 vs. 2.2 ± 1.7, t = 2.60, P = 0.009, with a least-squares mean difference of 0.21 [95% CI: 0.05–0.37]) and positive urine ketone levels (7.7% [39/509] vs. 15.4% [82/533], χ2 = 15.13, P <0.001) were lower in the CFD group. The CFD group had significantly less cholangitis (2.1% [13/634] vs. 4.0% [26/658], χ2 = 3.99, P = 0.046) but not pancreatitis (5.5% [35/634] vs. 6.5% [43/658], χ2 = 0.59, P = 0.444). Subgroup analysis revealed that CFD reduced the incidence of complications in patients with native papilla (odds ratio [OR]: 0.61, 95% CI: 0.39–0.95, P = 0.028) in the multivariable models. Conclusion::Ingesting 400 mL of CFD 2 h before ERCP is safe, with a reduction in post-ERCP fatigue, abdominal pain, and cholangitis during recovery.Trail Registration::ClinicalTrials.gov, No. NCT03075280.
9.Analysis of five-wind differentiation and treatment system of tic disorder based on the "manifestation-qi transformation" theory
Wenbo LIU ; Wenli SHI ; Bingxiang MA ; Xiaoyang TIAN ; Yudi LI ; Yingying WEN
Journal of Beijing University of Traditional Chinese Medicine 2024;47(8):1075-1080
Tic disorder (TD) is a neurodevelopmental disorder. According to the core symptoms,it can be classified as "liver wind","wind syndrome",and "concurrent". The clinical syndrome of TCM is based on wind,and the pathogenesis is based on the liver. However,the clinical symptoms of this disease are relatively complicated. Based on the " manifestation-qi transformation" theory,this study further explores the liver wind,lung wind,heart wind,spleen wind,and kidney wind from the pathological basis of intrinsic wind rash movement and proposes that the liver wind caused by hyperactivity of liver yang is the main cause of intrinsic wind rash movement in TD,and the lung wind caused by lung loss is the main cause. The liver is related to the heart,spleen,and kidney. Together,the five-wind affect the onset,development,and outcome of TD. Based on this understanding of the pathogenesis,it is necessary to identify the specific syndromes of the patients. The five-wind differentiation and treatment system uses the method of calming the liver and dispelling the lungs to treat the root of the internal wind rash movement. Xiaochaihu Decoction,Sangju Decoction,Cang'erzi Powder,and other prescriptions can be used with modification and subtract and use method of controlling heart fire,transporting spleen soil,and nourishing kidney water to treat derived images. Meanwhile,Xieqing Pill,Daochi Powder,Yigong Powder,Erchen Decoction,Liuwei Dihuang Pill,and other prescriptions can be used with modification.
10.A preliminary investigation of the key parameters of average value articulator based on mandibular movement trajectories in 100 adults with individual normal occlusion
Shenyao SHAN ; Yujia ZHU ; Junjie WANG ; Aonan WEN ; Zixiang GAO ; Qingzhao QIN ; Wenbo LI ; Yong WANG ; Yijiao ZHAO
Chinese Journal of Stomatology 2024;59(12):1228-1233
Objective:To explore the method of obtaining the key parameters of the average value articulator in healthy people based on mandibular movement trajectory data, with a view to providing a reference for the clinical application of the average value articulator.Methods:One hundred healthy volunteers (42 males and 58 females) with individual normal occlusion, aged 18-55 years old, who met the inclusion criteria were recruited from Beijing, and their mandibular movement trajectory data were collected. The left and right sagittal condylar inclination(SCI) and transversal condylar inclination(TCI) were obtained from the values of the articulator parameters which were generated in the mandibular movement analysis system.The SCI and TCI were grouped by gender and calculated separately for the two groups and the overall sample; the gender differences in the two parameters and the differences between the mean values of the two parameters and the average value articulator empirical values (35° for SCI and 15° for TCI) for the overall sample were compared.Results:The differences between SCI (35.8°±7.4°) and TCI [11.2° (11.3°)] in males and the corresponding parameters [35.6°±8.3° and 10.8° (9.5°), respectively] in females were not statistically significant ( t=0.10, P=0.922; Z=-0.60, P=0.552); the overall sample SCI (35.7°±7.9°) did not differ statistically from the average value articulator empirical value ( t=1.23, P=0.221), and the overall sample TCI [10.9° (10.3°)] was significantly smaller than the average value articulator empirical value ( W=5 825.00, P<0.001). Conclusions:The mandibular movement trajectory data of 100 adults with individual normal occlusion in this study shows that the gender factor does not affect the setting of the key parameters of the average value articulator, the SCI of the average value articulator empirical values is appropriate, and the TCI has the possibility of being on the large side. In the clinical use of the articulator to assist in the design of restorations, the parameter values should be rationally adjusted according to the actual situation of the patient′s dentition and mandibular movement.