1.Dihuang Yinzi Improves Cognitive Function of Mouse Model of Learning and Memory Impairments by Regulating Synaptic Plasticity via SIRT2
Wenting WANG ; Yangjing HAO ; Wenna SU ; Qinqing LI ; Shifeng CHU ; Junlong ZHANG ; Wenbin HE
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(6):9-17
ObjectiveTo investigate the effects of Dihuang Yinzi on the cognitive function in the mouse model of learning and memory impairments induced by scopolamine (SCOP) and explore the treatment mechanism. MethodsA mouse model of learning and memory impairment was induced by intraperitoneal injection of SCOP. Sixty male C57BL/6J mice were randomized into six groups: control (0.9% NaCl, n=10), model (SCOP 1 mg·kg-1·d-1, n=10), low-, medium-, and high-dose Dihuang Yinzi (SCOP 1 mg·kg-1·d-1 + Dihuang Yinzi 5.5, 11.0, and 22.0 g·kg-1·d-1, n=10), and donepezil (SCOP 1 mg·kg-1·d-1 + donepezil 0.84 mg·kg-1·d-1, n=10). Mice were administrated with corresponding drugs for 6 weeks. Modeling started in the 4th week, and mice in other groups except the control group were injected with SCOP intraperitoneally 40 min after daily gavage. Behavioral testing began in the 5th week, 30 min after modeling each day. The Morris water maze and novel object recognition tests were carried out to evaluate the spatial learning and memory function of mice. Nissl staining was employed to observe the survival of neurons and Nissl bodies in the hippocampal CA1 region. Western blot was employed to determine the protein levels of silent information regulator 2 (SIRT2), α-amino-3-hydroxy-5-methyl-4-isoxazole propionic acid (AMPA) receptor 1 (GluA1), protein kinase A (PKA), cAMP response element-binding protein (CREB), phosphorylated-CREB (p-CREB), postsynaptic density protein 95 (PSD95), growth-associated protein-43 (GAP-43), and synaptophysin (SYN) in the hippocampus. Immunofluorescence was used to detect the expression of doublecortin (DCX) in the hippocampal dentate gyrus (DG) region. ResultsCompared with the control group, the model group showed impaired learning and memory (P<0.01), obvious neuronal damage in the hippocampal CA1 region, a reduction in neuron survival (P<0.01), a decrease in DCX expression in the hippocampal DG region (P<0.01), down-regulated proteins levels of GluA1, PKA, p-CREB/CREB, PSD95, SYN, and GAP-43 in the hippocampal tissue (P<0.05, P<0.01), and an up-regulated protein level of SIRT2 (P<0.01). Compared with the model group, the medium- and high-dose Dihuang Yinzi groups and the donepezil group showed improvements in learning and memory (P<0.05, P<0.01), while the low-, medium-, and high-dose Dihuang Yinzi groups and the donepezil group had increased neuron survival (P<0.05, P<0.01). The medium-dose Dihuang Yinzi group and the donepezil group showed increased DCX expression (P<0.05, P<0.01). The medium- and high-dose Dihuang Yinzi groups and the donepezil group showed up-regulation in the protein levels of GluA1, PKA, p-CREB/CREB, PSD95, SYN, and GAP-43 (P<0.05, P<0.01) and down-regulation in the protein level of SIRT2 (P<0.01). ConclusionDihuang Yinzi can improve the cognitive function in the mouse model of learning and memory impairments induced by SCOP by inhibiting the upregulation of SIRT2, activating the PKA/CREB signaling pathway, improving synaptic plasticity, and reducing hippocampal neuronal damage.
2.Effect of Acupuncture with the Method of Soothing the Liver and Regulating the Mind on the TLR4/NF-κB Pathway in the Hippocampus of Lipopolysaccharide-Induced Depression Model Mice
Bingxin WU ; Yi ZHOU ; Sibo HAN ; Xichang HUANG ; Junye MA ; Baile NING ; Shanze WANG ; Wenbin FU
Journal of Traditional Chinese Medicine 2025;66(5):526-531
ObjectiveTo explore the potential mechanism of acupuncture with the method of soothing the liver and regulating the mind in improving depressive disorder. MethodsEighteen C57BL/6J mice were randomly divided into blank group, model group, and acupuncture group, with 6 mice in each group. The model group and the acupuncture group were subjected to depression induction by intraperitoneal injection of lipopolysaccharide (LPS), while the blank group received an equal volume of normal saline once daily for seven consecutive days. Concurrently, the acupuncture group received "soothing the liver and regulating the mind" acupuncture intervention starting from the first day of modeling, once daily for 14 days; whereas the blank group and the model group were only restrained without acupuncture. The sucrose preference test was used to assess sucrose preference rate, the open-field test to measure center stay time and total travel distance, and the forced swim test to evaluate immobility time. Hematoxylin-eosin (HE) staining was performed to observe hippocampal morphological changes. Enzyme-linked immunosorbent assay (ELISA) was used to detect levels of interleukin-1β (IL-1β), interleukin-6 (IL-6), and tumor necrosis factor-α (TNF-α) in hippocampal tissue. Western blot analysis was conducted to examine the protein expression levels of Toll-like receptor 4 (TLR4) and nuclear factor-κB (NF-κB) in the hippocampus. ResultsCompared to the blank group, the model group showed a significant reduction in sucrose preference rate, center stay time, and total travel distance, along with a significant increase in immobility time in the forced swim test, hippocampal IL-1β, IL-6, and TNF-α levels, as well as TLR4 and NF-κB protein expression (P<0.01), and the histological examination revealed blurred hippocampal neuronal boundaries, loose arrangement, and some neurons exhibiting nuclear pyknosis and deep staining. Compared to the model group, the acupuncture group demonstrated a significant increase in sucrose preference rate, center stay time, and total travel distance, along with a significant reduction in immobility time in the forced swim test, hippocampal IL-1β, IL-6, and TNF-α levels, and TLR4 and NF-κB protein expression (P<0.01), and the histological analysis showed that hippocampal neurons in the acupuncture group were more tightly arranged, with reduced nuclear pyknosis and deep staining. ConclusionAcupuncture with the "soothing the liver and regulating the mind" method can significantly improve depression-like behavior, potentially by inhibiting the hippocampal TLR4/NF-κB signaling pathway and alleviating inflammatory responses.
3.Clinical applicability analysis of predictive models for radiation-induced lung injury in non-small cell lung cancer
Feng GUO ; Meng ZHANG ; Aonan DU ; Wenbin SHEN ; Honglin CHEN ; Qiang WANG
Chinese Journal of Radiological Health 2025;34(1):126-134
Objective To develop and validate a model to predict the risk of radiation-induced lung injury (RILI) and assess its clinical feasibility. Methods Clinical data from 125 patients with non-small cell lung cancer (NSCLC) were included in the study. The patients were divided into training group (88 cases) and validation group (38 cases). Key predictive factors were identified using univariate and multivariate logistic regression analyses combined with least absolute shrinkage and selection operator (LASSO) regression. A predictive model was constructed and evaluated using a nomogram, receiver operating characteristic (ROC) curve, calibration curve, and decision curve analysis. Results The key variables identified by the model were tumor volume (P = 0.017), Eastern Cooperative Oncology Group performance status score (P = 0.035), 95% of the minimum dose to the target volume (P = 0.028), percentage of bilateral lung volume receiving 20 Gy of radiation (P < 0.001), and neutrophil-to-lymphocyte ratio (P = 0.021). The ROC curve showed that the areas under the curve (AUC) for the model in the training and validation groups were 0.987 and 0.992, respectively, indicating good predictive ability. The calibration curve and decision curve further confirmed the accuracy and clinical practicability of the model. Conclusion The predictive model proposed in this study can accurately assess the risk of developing RILI in patients with NSCLC who have undergone radiotherapy, demonstrating its potential value in clinical practice.
4.Treating premature ejaculation combined with anxiety and depression based on the "four-dimensional integration" of the "holism of body and spirit" theory
Yi WEI ; Zhiming HONG ; Junfeng QIU ; Zilong CHEN ; Hao KUANG ; Yangling ZENG ; Quan WANG ; Wenbin ZHOU
Journal of Beijing University of Traditional Chinese Medicine 2025;48(3):418-423
Premature ejaculation refers to a sexual dysfunction in which men experience a short intravaginal ejaculation latency and a lack of control over ejaculation during sexual activity. The onset of this condition is often accompanied by anxiety and depression, which can seriously affect the quality of the patient′s sexual life and the relationship between partners. Based on the "integration of body and spirit" theory in traditional Chinese medicine, our team believes that this condition is a comorbidity of physical and spiritual factors. We propose that the core pathogenesis of this disease lies in the "loss of form and essence, impairment of spirit, and depression of the mind, "while the primary treatment principle involves "nourishing form and regulating spirit." As a result, a new diagnosis and treatment approach of "four-dimensional integration" is summarized in this study. The disease is treated through the four dimensions of shape, body, spirit, and emotion. Traditional Chinese medicine is used to adjust the shape in cases where the physical form is damaged. For individuals with depression of heart and liver qi, the treatment focuses on soothing the heart and smoothing liver qi, and the modified Wangyou Powder and Xuanzhi Decoction is used. In cases where the heart and kidney function are compromised, the treatment involves nourishing both the heart and kidney while restoring interaction between the heart and the kidney, and modified Jihuo Yansi Elixir is used. To reduce the sensitivity of the glans penis, the patient′s body is washed with a traditional Chinese medicine formula, and a delicate fumigation formula is decocted for external washing. For those who are not in tune with their god, psychological counseling can be used to regulate their spirit and advocate "self-partner" and psychotherapy. If there are issues with intimacy, partners should focus on cooperating during foreplay, sexual intercourse, and post-coital interactions. Overall, the treatment aims to harmonize the body and spirit, addressing both physical and psychological factors through a comprehensive, multi-dimensional approach. This method provides new perspectives and ideas for the clinical diagnosis and treatment of this condition.
5.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
6.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
7.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
8.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
9.Preparation and evaluation of quality,targeting and cytotoxicity of triptolide-loaded targeting nanoparticles
Moli YIN ; Wenbin LUO ; Jingzhe XU ; Zebo TANG ; Ni GUO ; Youxing LAO ; Huiyan WANG
China Pharmacy 2025;36(12):1457-1462
OBJECTIVE To prepare nanoparticle-based targeting preparation loaded with triptolide (TP), and evaluate its quality, targeting ability and cytotoxic effects. METHODS Polymer nanoparticles carrying TP-targeted folic acid (FA) receptor (TP@PLGA-PEG-FA) were fabricated using poly (lactic-co-glycolic acid)/polyethylene glycol/FA (PLGA-PEG-FA) as the carrier by emulsion and volatilization technique. The morphology and distribution were observed, and their particle size, Zeta potential, polydispersity index (PDI), drug loading capacity and encapsulation efficiency were measured. Their stability, blood compatibility, in vitro drug release, uptake by RAW264.7 cells (localization with fluorescent dye Cy3.5), and in vitro cytotoxicity were evaluated. RESULTS TP@PLGA-PEG-FA exhibited spherical shape and uniform distribution, with particle size of (122.60±0.02) nm, Zeta potential of (-17.6±0.6)mV, and PDI of 0.26±0.02; drug loading capacity and encapsulation efficiency of TP were measured to be (7.78±0.05)% and (68.62±0.03)%, respectively. The hemolysis rates of 100, 200, 300, 400 µg/mL TP@PLGA- PEG-FA were 0.77%, 0.92%, 1.34% and 1.63%, respectively. There were no significant changes in particle size, PDI and Zeta potential when TP@PLGA-PEG-FA were placed in 4 ℃ water for 14 days and in DMEM culture medium containing 10% fetal bovine serum at 37 ℃ for 12 h. The cumulative release rate of TP@PLGA-PEG-FA was (84.83±0.29)% in phosphate buffer at pH5.5 for 72 h, which was significantly higher than the cumulative release rates in phosphate buffer solutions at pH7.4 and 6.5 for 72 h ([ 42.37±0.35)% and (63.83±0.29)% , respectively] (P<0.05). Activated RAW264.7 cells took up significantly more Cy3.5@PLGA-PEG-FA than they took up Cy3.5@PLGA-PEG-FA+free FA and Cy3.5@PLGA-PEG. When the mass concentration of TP was≥15.63 ng/mL, the survival rates of activated cells in the TP@PLGA-PEG-FA groups were significantly lower than those of the same mass concentration of free TP groups (P<0.05). CONCLUSIONS The prepared TP@PLGA-PEG-FA has high stability, good blood compatibility, active targeting and cytotoxicity to inflammatory cells.
10.Feasibility and safety of a new portable endoscopic system for the diagnosis and treatment of abdominal trauma in animal models
Ting ZHANG ; Wenbin ZOU ; Chunhui JIANG ; Zhen WANG ; Liping CAI ; Zhaoshen LI ; Zhuan LIAO
Chinese Journal of Digestive Endoscopy 2024;41(1):25-29
Objective:To compare the feasibility and safety of a new portable endoscopic system and the conventional endoscopic system for the detection and emergency treatment of abdominal trauma in animal models.Methods:Three healthy Bama pigs, which were fasted and water deprivation for 8 h before surgery and then underwent induction anesthesia. A layer-by-layer incision was made into the abdominal cavity of Bama pigs. An artificial pneumoperitoneum was established using a laparoscopic pneumoperitoneum machine. A bullet model was inserted into the abdominal cavity to build the bullet wound model. After the bullet model was removed, a shrapnel model was inserted into the mid-abdomen to build the shrapnel wound model. The two types of endoscopic system were used to detect, remove bullet model or shrapnel model of the three Bama pigs respectively. The procedure order of the two systems was assigned according to the random number table method. The surgical success, operation time, endoscopy pipeline patency, endoscopic operation satisfaction, adverse events and equipment defects were recorded.Results:Three surgeries were performed using the new portable endoscopic system and three other surgeries using the conventional endoscopic system, all of which were successful. The time of the new portable endoscopic system to find and remove the bullet model, and the shrapnel model were 232.33±11.68 s, 300.33±57.70 s, 170.00±44.44 s and 52.67±2.52 s, respectively. The corresponding time of the conventional endoscopic system were 232.67±21.20 s ( t=-0.054, P=0.962), 256.67±67.00 s ( t=0.880, P=0.472), 176.00±52.42 s ( t=-0.111, P=0.922), 58.67±14.84 s ( t=-0.832, P=0.493), respectively. There was no significant difference between the two systems ( P>0.05). The endoscopy tubes of the two endoscopic systems were both smooth. The operator was satisfied with the endoscopic procedures of both endoscopic systems, and no adverse event or device defect occurred. Conclusion:The portable endoscopic system proves to be safe and feasible for the diagnosis and treatment of abdominal trauma in animal models.


Result Analysis
Print
Save
E-mail