1.Temporal trends in the frequency of meat, egg and milk consumption among primary and secondary school students in rural central and western China, 2015-2023
Chinese Journal of School Health 2026;47(3):332-336
Objective:
To analyze the trends of the frequency of meat, egg, and milk consumption among rural primary and junior high school students in central and western China covered by the Nutrition Improvement Program for Rural Compulsory Education Students (NIPRCES) from 2015 to 2023, so as to provide basis for formulating more targeted nutrition intervention policies and health education strategies.
Methods:
Using data from six rounds of monitoring and evaluation (2015-2021 and 2023), the study included 323 870 students from grade 3 to 9 across 22 provinces (autonomous regions and municipalities) in central and western China. The consumption frequencies of meat, egg, and milk over the past week were collected via questionnaires. The Cochran-Armitage trend test was used to analyze temporal trends, and multivariable Logistic regression models were employed to analyze factors associated with the frequency of meat, egg and milk consumption and to test for interaction effects between the year and gender, region, and grade level.
Results:
From 2015 to 2023, the proportion of students consuming meat, egg, and milk ≥1 time/day increased from 23.20 %, 10.71%, and 0.74% to 35.53%, 22.09%, and 26.63%, respectively. Trend tests indicated a significant upward trend for the daily intake of all three food categories for meat, egg and milk over the years ( Z =67.18, 64.90, 93.14, all P <0.01). Multivariable Logistic regression analysis showed that the daily meat intake was lower in the central region than in the western region ( OR=0.77, 95%CI =0.76-0.78), whereas the daily intake of eggs ( OR=1.19, 95%CI =1.17-1.22) and milk ( OR= 1.27 , 95%CI =1.24-1.29) was higher in the central region (all P <0.05). Compared with grade 3-4 students, junior high school students had lower daily intake of meat, eggs, and milk≥1 time/day ( OR =0.95, 0.77, 0.77, all P <0.05), with a declining trend as grade increased. Girls also had lower daily intake of meat, eggs, and milk ≥1 time/day than boys ( OR =0.95,0.93,0.91, all P < 0.05). Significant interactions were observed between year and region, as well as between year and grade (all P <0.05).
Conclusion
From 2015 to 2023, the NIPRCES improved the intake level of among rural students, but the situation of relatively insufficient intake of egg and milk among females, junior high school students and those in the western region still exists.
2.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
3.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
4.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
5.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
6.Deep space environment empowering drug design and development.
Yanpeng FANG ; Bin FENG ; Weizheng LI ; Liyong ZHU ; Fei CHEN ; Wenbin ZENG
Journal of Central South University(Medical Sciences) 2025;50(8):1371-1384
The unique characteristics of the deep space environment, microgravity, cosmic radiation, and extreme temperature fluctuations, are emerging as major driving forces for pharmaceutical innovation. These factors provide new avenues for optimizing drug formulations, improving crystal structure quality, and accelerating the discovery of therapeutic targets. Advances in deep space research not only help overcome critical bottlenecks in terrestrial drug development but also promote progress in structure-based drug design and deepen understanding of cellular stress-response mechanisms. Current progress in space-based pharmaceutical research primarily includes the study of disease mechanisms under microgravity, protein crystallization in microgravity, and drug development utilizing deep space radiation and resources. However, the operational complexity, high costs, and limited data reproducibility of space experiments remain key challenges hindering widespread application. Looking ahead, with the integration of automation, artificial intelligence analysis, and on-orbit manufacturing, deep space drug development is expected to achieve greater scalability and precision, opening a new frontier in biopharmaceutical science.
Drug Design
;
Drug Development/methods*
;
Humans
;
Weightlessness
;
Space Flight
;
Artificial Intelligence
;
Extraterrestrial Environment
7.Transcatheter closure of atrial septal defect using fully biodegradable occluder under ultrasound guidance: A case report
Ying' ; ao ZHAO ; Yiming YAN ; Ziping LI ; Hang LI ; Fengwen ZHANG ; Fang FANG ; Guangzhi ZHAO ; Jing DONG ; Chuangshi WANG ; Jiande WANG ; Wenbin OUYANG ; Xiangbin PAN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(12):1796-1799
Currently, transcatheter intervention is the preferred treatment for patients with anatomically suitable atrial septal defects. However, the use of nickel-titanium alloy occluders in interventional procedures results in lifelong presence of the implant in the body, leading to complications such as metal allergies and arrhythmias in some patients. To overcome the short-term and long-term complications associated with the presence of metal, and to avoid radiation exposure and metal toxicity, this paper reports a case of successful transcatheter closure of atrial septal defect in a pediatric patient with metal allergies using fully biodegradable occluder under ultrasound guidance, achieving excellent results by interventional therapy.
8.A case of dMMR/MSI-H/TMB-H colon cancer with brain metastasis treated with PD-1 monoclonal antibody
Tao XIANG ; Hangyu ZHANG ; Weijia FANG ; Wenbin CHEN
Journal of Zhejiang University. Medical sciences 2024;53(1):58-63
A 70-year-old man had radical surgery for colon cancer one year before the symptoms of memory loss and decreasing cognitive function.Subsequent magnetic resonance imaging revealed a brain mass,which was surgically resected and confirmed to be metastatic intestinal adenocarcinoma.Immunohistochemistry of the primary tumor and brain metastasis showed mismatch repair deficiency.The patient received adjuvant chemotherapy after surgery.However,the brain metastasis relapsed one month after the last chemotherapy.Genetic testing on the resected colon tumor samples confirmed microsatellite instability-high with a high tumor mutation burden by 77.7 muts/Mb.The patient was subsequently treated with programmed death-1(PD-1)monoclonal antibody pembrolizumab(keytruda).The brain metastatic lesions were completely shrunk,and a complete clinical response was achieved.
9.Clinical efficacy of percutaneous balloon mitral valvuloplasty under echocardiographic guidance for moderate to severe mitral stenosis during pregnancy
Peijian WEI ; Wenchao LI ; Hang LI ; Fang FANG ; Fengwen ZHANG ; Wenbin OUYANG ; Shiguo LI ; Deyuan ZHANG ; Yixian LIN ; Xiangbin PAN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2024;31(09):1333-1337
Objective To investigate the effect of percutaneous balloon mitral valvuloplasty under echocardiographic guidance for patients with moderate to severe mitral stenosis during pregnancy. Methods A retrospective observational study was conducted to include pregnant women who were diagnosed with moderate to severe mitral stenosis and underwent percutaneous balloon mitral valvuloplasty under echocardiographic guidance in Fuwai Hospital from August 2018 to June 2022, and their baseline characteristics, surgical outcomes, echocardiographic results, and follow-up results were analyzed. Results A total of 3 pregnant women aged 30-35 years, with gestational age of 19-26 weeks, and New York Heart Association (NYHA) function class Ⅲ were included. All the procedures were successfully performed. The mitral valve orifice area increased from 0.9 cm2 preoperatively to 2.1 cm2 postoperatively. The mean transvalvular pressure gradient decreased from 15.0 mm Hg preoperatively to 6.7 mm Hg postoperatively. No perioperative adverse events occurred. The follow-up time ranged from 3 to 48 months. All patients delivered uneventfully and returned to normal life, with maternal-fetal safety. Conclusion Percutaneous balloon mitral valvuloplasty under echocardiographic guidance is a feasible and effective procedure for the treatment of patients with moderate to severe mitral stenosis in pregnancy, with satisfactory maternal-fetal outcomes.
10.Nursing effect of PDCA circulating nursing model based on health concept on patients with valvular heart disease
Liying XING ; Wenbin FANG ; Li LI
China Modern Doctor 2024;62(1):78-81
Objective To explore the nursing effect of PDCA circulation nursing model based on health concept on patients with valvular heart disease.Methods A total of 116 patients with valvular heart disease hospitalized in Jinhua People's Hospital from December 2018 to December 2021 were selected as study objects.According to random number table method,the included patients were divided into control group and observation group,with 58 cases in each group.The patients in control group received routine nursing intervention,while the patients in observation group received PDCA circulation nursing intervention.The quality of life,self-rating anxiety scale(SAS)score,self-rating depression scale(SDS)score,complications and nursing satisfaction of two groups were compared.Results After nursing,the scores of physical function,psychological function,social function and overall quality of life in two groups were significantly higher than those before nursing(P<0.05),and the scores of above indexes of patients in observation group were significantly higher than those in control group(P<0.05).After nursing,SAS and SDS scores of two groups were significantly lower than those before nursing(P<0.05),and SAS and SDS scores of observation group were significantly lower than those of control group(P<0.05).The complication rate of observation group was significantly lower than that of control group(χ2=4.668,P=0.003).There was no significant difference in nursing satisfaction between two groups(χ2=2.511,P=0.113).Conclusion Patients with valvular heart disease can improve their quality of life,relieve anxiety and depression,and reduce complications by using PDCA circulation nursing model based on health concept.


Result Analysis
Print
Save
E-mail