1.Association between long-term exposure to low-dose ionizing radiation and metabolic syndrome among medical radiologists
Changyong WEN ; Xiaoman ZHOU ; Xiaolian LIU ; Yiqing LIAN ; Weizhen GUO ; Yanting CHEN ; Xin LAN ; Mingfang LI ; Sufen ZHANG ; Weixu HUANG ; Jianming ZOU ; Huifeng CHEN
Journal of Environmental and Occupational Medicine 2025;42(10):1209-1215
Background In recent years, the increasingly widespread application of nuclear and medical radiation technologies has resulted in a large number of occupational populations exposed to low-dose ionizing radiation (LDIR). At present, there is no consistent conclusion on the effects of long-term exposure to LDIR on the metabolic health of the occupational population. Objective To explore the association between long-term exposure to LDIR and metabolic syndrome (MetS) among medical radiologists. Methods A cross-sectional study was conducted to enroll
3.Dentate Gyrus Morphogenesis is Regulated by an Autism Risk Gene Trio Function in Granule Cells.
Mengwen SUN ; Weizhen XUE ; Hu MENG ; Xiaoxuan SUN ; Tianlan LU ; Weihua YUE ; Lifang WANG ; Dai ZHANG ; Jun LI
Neuroscience Bulletin 2025;41(1):1-15
Autism Spectrum Disorders (ASDs) are reported as a group of neurodevelopmental disorders. The structural changes of brain regions including the hippocampus were widely reported in autistic patients and mouse models with dysfunction of ASD risk genes, but the underlying mechanisms are not fully understood. Here, we report that deletion of Trio, a high-susceptibility gene of ASDs, causes a postnatal dentate gyrus (DG) hypoplasia with a zigzagged suprapyramidal blade, and the Trio-deficient mice display autism-like behaviors. The impaired morphogenesis of DG is mainly caused by disturbing the postnatal distribution of postmitotic granule cells (GCs), which further results in a migration deficit of neural progenitors. Furthermore, we reveal that Trio plays different roles in various excitatory neural cells by spatial transcriptomic sequencing, especially the role of regulating the migration of postmitotic GCs. In summary, our findings provide evidence of cellular mechanisms that Trio is involved in postnatal DG morphogenesis.
Animals
;
Dentate Gyrus/metabolism*
;
Mice
;
Morphogenesis/physiology*
;
Neurons/pathology*
;
Cell Movement
;
Mice, Inbred C57BL
;
Autism Spectrum Disorder/pathology*
;
Mice, Knockout
;
Neural Stem Cells
;
Male
;
Neurogenesis
;
Autistic Disorder/genetics*
4.Analysis of effectiveness of Holosight robot navigation-assisted percutaneous cannulated screw fixation in treatment of femoral neck fractures.
Weizhen XU ; Zhenqi DING ; Hui LIU ; Jinhui ZHANG ; Yuanfei XIONG ; Jin WU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(6):673-679
OBJECTIVE:
To investigate the effectiveness of Holosight robotic navigation-assisted percutaneous cannulated screw fixation for femoral neck fractures.
METHODS:
A retrospective analysis was conducted on 65 patients with femoral neck fractures treated with cannulated screw fixation between January 2022 and February 2024. Among them, 31 patients underwent robotic navigation-assisted screw placement (navigation group), while 34 underwent conventional freehand percutaneous screw fixation (freehand group). Baseline characteristics, including age, gender, fracture side, injury mechanism, Garden classification, Pauwels classification, and time from injury to operation, showed no significant differences between the two groups ( P>0.05). The operation time, intraoperative blood loss, fluoroscopy frequency, fracture healing time, and complications were recorded and compared, and hip function was evaluated by Harris score at last follow-up. Postoperative anteroposterior and lateral hip X-ray films were taken to assess screw distribution accuracy, including deviation from the femoral neck axis, inter-screw parallelism, and distance from screws to the femoral neck cortex.
RESULTS:
No significant difference was observed in operation time between the two groups ( P>0.05). However, the navigation group demonstrated superior outcomes in intraoperative blood loss, fluoroscopy frequency, deviation from the femoral neck axis, inter-screw parallelism, and distance from screws to the femoral neck cortex ( P<0.05). No incision infections or deep vein thrombosis occurred. All patients were followed up 12-18 months (mean, 16 months). In the freehand group, 1 case suffered from cannulated screw dislodgement and nonunion secondary to osteonecrosis of femoral head at 1 year after operation, 1 case suffered from screw penetration secondary to osteonecrosis of femoral head at 5 months after operation; and 1 case suffered from nonunion secondary to osteonecrosis of femoral head at 6 months after operation in the navigation group. All the 3 patients underwent internal fixators removal and total hip arthroplasty. There was no significant difference in the incidence of complications between the two groups ( P>0.05). The fracture healing time and hip Harris score at last follow-up in the navigation group were significantly better than those in the freehand group ( P<0.05).
CONCLUSION
Compared to freehand percutaneous screw fixation, Holosight robotic navigation-assisted cannulated screw fixation for femoral neck fractures achieves higher precision, reduced intraoperative radiation exposure, smaller incisions, and superior postoperative hip function recovery.
Humans
;
Femoral Neck Fractures/diagnostic imaging*
;
Bone Screws
;
Fracture Fixation, Internal/instrumentation*
;
Male
;
Female
;
Retrospective Studies
;
Robotic Surgical Procedures/methods*
;
Middle Aged
;
Aged
;
Adult
;
Treatment Outcome
;
Operative Time
;
Fracture Healing
;
Surgery, Computer-Assisted/methods*
;
Fluoroscopy
5.Experience of parents engaging in kangaroo mother care for preterm infants in the NICU:a qualitative Meta-synthesis
Weizhen ZOU ; Liqing YUE ; Bingyu LI ; Xiuwen CHEN ; Bin PENG ; Tiange ZHANG ; Qiang PENG ; Huiqiong CHEN ; Moyan LIU
Chinese Journal of Nursing 2025;60(20):2534-2541
Objective To systematically evaluate and analyze qualitative studies of parental engagement in kangaroo mother care experiences for preterm infants in the NICU,aiming to provide references for promoting the early recovery of preterm infants in NICU and improving the quality of nursing services.Methods Relevant were searched for qualitative studies of parental engagement in kangaroo mother care for preterm infants in NICU.The search time limit was from the construction of the database to July 19,2024.The quality of the included literature was assessed using the Joanna Brigg Institute's(JBI)Australian Centre for Evidence-Based Health Care's Quality Assessment Criteria for Qualitative Research,and the results were integrated using the meta-integration methods.Results A total of 17 papers were included in the literature,and 61 findings were extracted,grouped into 10 new categories.These were further synthesized into 4 integrated findings:physical and psychological perceptions of participation in kangaroo mother care;challenges to participation in kangaroo mother care;facilitators of participation in kangaroo mother care;expectations and suggestions for kangaroo mother care.Conclusion Hospital administrators should further improve the management specifications of kangaroo mother care for preterm infants in NICU,optimize resource allocation and strengthen publicity.At the same time,healthcare professionals should actively promote the establishment of peer and family support systems and increase participation in kangaroo mother care to facilitate early recovery of preterm infants in NICU and to continuously promote the improvement of nursing service quality.
6.Analysis on appraisal of ophthalmic medical malpractice
Weizhen CHEN ; Zhitao GE ; Shi LIU ; Zhihu ZHANG ; Lihong LIU ; Jiaqi ZHANG ; Shuangxue HAN
Chinese Journal of Forensic Medicine 2025;40(4):415-419
Objective To identify the key points of forensic appraisal in ophthalmic medical-injury compensation cases and propose targeted measures to prevent disputes.Methods A retrospective analysis was conducted of the appraisal conclusions from 15 ophthalmology medical-injury liability lawsuits handled at a single tertiary hospital over the past five years.We summarized the constitutive characteristics of liability cases,causes of medical injury,and issues encountered during appraisal.Results Among cases undergoing medical-injury liability appraisal,retinal diseases and ocular tumors predominated.The main issues included inadequate informed consent,failure to exercise due care during surgery/treatment,non-standard medical record documentation,insufficient attention to medical risks,and inadequate clinical assessment.Conclusions By summarizing common faults in ophthalmic disputes and problems revealed by forensic appraisal,targeted responses can be implemented to ensure patient safety and promote high-quality medical services.
7.Finite element analysis of three internal fixation methods for type AO/OTA A3 distal femoral fractures
Jinhui ZHANG ; Hui LIU ; Weizhen XU ; Yuanfei XIONG ; Jianping ZHANG ; Jin WU
Chinese Journal of Tissue Engineering Research 2025;29(27):5728-5734
BACKGROUND:The age distribution of patients with distal femur fracture is bimodal,being more common in young adults with high-energy injuries and older individuals with low-energy injuries.In cases of complex distal femoral fractures,a single less invasive stabilization system or retrograde femoral nail is insufficient to provide a stable environment for fracture healing and combined fixation is often necessary.OBJECTIVE:A novel combined fixation method(less invasive stabilization system combined with retrograde tibial nail)was developed for the treatment of type A3 distal femur fractures.Using finite element analysis,the bio-mechanical properties of this method were compared with two common combined fixation methods—dual plate(less invasive stabilization system combined with locking compression plate)and nail plate combination(less invasive stabilization system combined with retrograde femoral nail).This study aims to provide a theoretical basis for the selection of clinical internal fixation methods for distal femur fracture.METHODS:CT images of a 23-year-old healthy male volunteer were utilized to reconstruct the femur three-dimensional model using Mimics and Geomagic Studio software.This model was then compared with in vitro finite element analysis data from existing literature to validate the accuracy of the femoral three-dimensional model.The three-dimensional model of type A3 distal femur fractures and internal fixation were then created using Creo 5.0 software.Three kinds of different combined fixation methods(less invasive stabilization system+retrograde tibial nail,less invasive stabilization system+locking compression plate,less invasive stabilization system+retrograde femoral nail)were assembled and subjected to Boolean operation to establish three sets of finite element models.These models were then imported into Abaqus finite element analysis software to assign material properties,apply consistent boundary conditions,and submit calculations under three loads(normal standing,slow walking,and descending stairs).The resulting stress distribution within the internal fixation as well as overall and local deformation of the femur was analyzed.Furthermore,the failure risk and anti-deformation ability of the new combined fixation method(less invasive stabilization system combined with retrograde tibial nail)were evaluated.RESULTS AND CONCLUSION:(1)Although the anti-deformation ability of the less invasive stabilization system combined with retrograde tibial nail was approximately 10%lower than that of the less invasive stabilization system combined with locking compression plate,it was comparable to that of less invasive stabilization system combined with retrograde femoral nail and demonstrated good anti-deformation ability.(2)The stiffness of the femur with all three combined fixation methods remained consistent during gait,while femur displacement increased linearly with load,indicating high stability.(3)The failure risk associated with less invasive stabilization system combined with retrograde tibial nail was lower than that of the other two methods,with a 2.94%reduction in failure risk compared to less invasive stabilization system combined with locking compression plate.(4)This new combined fixation method offers distinct advantages in terms of anti-deformation ability,safety,and effectiveness,laying a theoretical foundation for further clinical application.
8.Analysis of infection status and genetic evolution of B2L and F1L genes in epidemic orf virus isolates from primary goat and sheep-producing areas in Anhui Province from 2021 to 2023
Liujun ZHANG ; Jiale CHEN ; Xing FENG ; Weizhen CHEN ; Yafei DENG ; Bo WANG ; Guolin ZUO ; Shaojun HE ; Honglei XIN ; Deyi LIU
Chinese Journal of Zoonoses 2025;41(7):697-703
This study was aimed at investigating the infection status of orf virus(ORFV)and the genetic evolution characteristics of epidemic ORFV isolates from Anhui province.A total of 303 clinical samples collected from major meat sheep breeding cities in An-hui during 2021-2023 were subjected to ORFV detection with fluorescence quantitative PCR(qPCR).The full-length B2L and F1L genes of ORFV in the positive samples were amplified through conventional PCR and sequenced.Genetic evolution analysis of the B2L and F1L genes was conducted after sequencing.The qPCR results indicated a total ORFV positivity rate in the clinical samples of 48.8%(148/303).Multiple sequence comparisons indicated that the B2L genes of 56 sample isolates shared 96.7%-100.0%DNA and 97.4%-100.0%amino acid sequence identity.Moreover,the F2L genes of 56 sample isolates shared 95.1%-100.0%DNA and 95.0%-100.0%amino acid sequence identity.The genetic evolution tree constructed with the B2L gene DNA sequences indicated sample iso-lates and 21 reference strains located in subgroup 1,and 26 sheep-derived sample isolates and 17 reference strains located in sub-group 2.Among them,the goat-derived sample isolate FY-TYA was located in the same sub-branch as the human-derived reference strain Gansu,whereas the goat-derived sample isolate FY-XQC was located in the same sub-branch as the reference strains China Vaccine and OV-HLJ-04.The genetic evolution tree constructed with the F1L gene DNA sequences showed,the goat sample isolates FY-XQA and FY-XQC were located in the same sub-branch as the sheep-derived reference strain Xinjiang.ORFV infection was rela-tively widespread in the major meat sheep breeding areas of Anhui province,and the DNA and amino acid sequences of the B2L and F1L genes of current circulating ORFV isolates showed different degrees of genetic variation,among which F1L gene had a high de-gree of variation.Furthermore,some goat-derived sample isolates were closely related to human,vaccine,and sheep-derived refer-ence strains.These results may serve as a reference for the prevention and control of ORFV infection in Anhui province.
9.Analysis of infection status and genetic evolution of B2L and F1L genes in epidemic orf virus isolates from primary goat and sheep-producing areas in Anhui Province from 2021 to 2023
Liujun ZHANG ; Jiale CHEN ; Xing FENG ; Weizhen CHEN ; Yafei DENG ; Bo WANG ; Guolin ZUO ; Shaojun HE ; Honglei XIN ; Deyi LIU
Chinese Journal of Zoonoses 2025;41(7):697-703
This study was aimed at investigating the infection status of orf virus(ORFV)and the genetic evolution characteristics of epidemic ORFV isolates from Anhui province.A total of 303 clinical samples collected from major meat sheep breeding cities in An-hui during 2021-2023 were subjected to ORFV detection with fluorescence quantitative PCR(qPCR).The full-length B2L and F1L genes of ORFV in the positive samples were amplified through conventional PCR and sequenced.Genetic evolution analysis of the B2L and F1L genes was conducted after sequencing.The qPCR results indicated a total ORFV positivity rate in the clinical samples of 48.8%(148/303).Multiple sequence comparisons indicated that the B2L genes of 56 sample isolates shared 96.7%-100.0%DNA and 97.4%-100.0%amino acid sequence identity.Moreover,the F2L genes of 56 sample isolates shared 95.1%-100.0%DNA and 95.0%-100.0%amino acid sequence identity.The genetic evolution tree constructed with the B2L gene DNA sequences indicated sample iso-lates and 21 reference strains located in subgroup 1,and 26 sheep-derived sample isolates and 17 reference strains located in sub-group 2.Among them,the goat-derived sample isolate FY-TYA was located in the same sub-branch as the human-derived reference strain Gansu,whereas the goat-derived sample isolate FY-XQC was located in the same sub-branch as the reference strains China Vaccine and OV-HLJ-04.The genetic evolution tree constructed with the F1L gene DNA sequences showed,the goat sample isolates FY-XQA and FY-XQC were located in the same sub-branch as the sheep-derived reference strain Xinjiang.ORFV infection was rela-tively widespread in the major meat sheep breeding areas of Anhui province,and the DNA and amino acid sequences of the B2L and F1L genes of current circulating ORFV isolates showed different degrees of genetic variation,among which F1L gene had a high de-gree of variation.Furthermore,some goat-derived sample isolates were closely related to human,vaccine,and sheep-derived refer-ence strains.These results may serve as a reference for the prevention and control of ORFV infection in Anhui province.
10.Finite element analysis of three internal fixation methods for type AO/OTA A3 distal femoral fractures
Jinhui ZHANG ; Hui LIU ; Weizhen XU ; Yuanfei XIONG ; Jianping ZHANG ; Jin WU
Chinese Journal of Tissue Engineering Research 2025;29(27):5728-5734
BACKGROUND:The age distribution of patients with distal femur fracture is bimodal,being more common in young adults with high-energy injuries and older individuals with low-energy injuries.In cases of complex distal femoral fractures,a single less invasive stabilization system or retrograde femoral nail is insufficient to provide a stable environment for fracture healing and combined fixation is often necessary.OBJECTIVE:A novel combined fixation method(less invasive stabilization system combined with retrograde tibial nail)was developed for the treatment of type A3 distal femur fractures.Using finite element analysis,the bio-mechanical properties of this method were compared with two common combined fixation methods—dual plate(less invasive stabilization system combined with locking compression plate)and nail plate combination(less invasive stabilization system combined with retrograde femoral nail).This study aims to provide a theoretical basis for the selection of clinical internal fixation methods for distal femur fracture.METHODS:CT images of a 23-year-old healthy male volunteer were utilized to reconstruct the femur three-dimensional model using Mimics and Geomagic Studio software.This model was then compared with in vitro finite element analysis data from existing literature to validate the accuracy of the femoral three-dimensional model.The three-dimensional model of type A3 distal femur fractures and internal fixation were then created using Creo 5.0 software.Three kinds of different combined fixation methods(less invasive stabilization system+retrograde tibial nail,less invasive stabilization system+locking compression plate,less invasive stabilization system+retrograde femoral nail)were assembled and subjected to Boolean operation to establish three sets of finite element models.These models were then imported into Abaqus finite element analysis software to assign material properties,apply consistent boundary conditions,and submit calculations under three loads(normal standing,slow walking,and descending stairs).The resulting stress distribution within the internal fixation as well as overall and local deformation of the femur was analyzed.Furthermore,the failure risk and anti-deformation ability of the new combined fixation method(less invasive stabilization system combined with retrograde tibial nail)were evaluated.RESULTS AND CONCLUSION:(1)Although the anti-deformation ability of the less invasive stabilization system combined with retrograde tibial nail was approximately 10%lower than that of the less invasive stabilization system combined with locking compression plate,it was comparable to that of less invasive stabilization system combined with retrograde femoral nail and demonstrated good anti-deformation ability.(2)The stiffness of the femur with all three combined fixation methods remained consistent during gait,while femur displacement increased linearly with load,indicating high stability.(3)The failure risk associated with less invasive stabilization system combined with retrograde tibial nail was lower than that of the other two methods,with a 2.94%reduction in failure risk compared to less invasive stabilization system combined with locking compression plate.(4)This new combined fixation method offers distinct advantages in terms of anti-deformation ability,safety,and effectiveness,laying a theoretical foundation for further clinical application.

Result Analysis
Print
Save
E-mail