1.Analysis of the results of external quality control for EBER in situ hybridization in 38 laboratories
Qing CAI ; Wenyang GUO ; Xiaowei XUE ; Detian WANG ; Xianbo WANG ; Weixun ZHOU
Chinese Journal of Clinical and Experimental Pathology 2025;41(7):918-923
Purpose The results of EBER in situ hybridization on the external quality assessment(EQA)organ-ized by the pathology Equipment Branch of the China Association of Medical Equipment were analyzed,for providing technical support for the standardization and normalization of the technology.Methods Paraffin-embedded sections of confirmed EBV-positive diffuse large B-cell lymphoma were selected as the evaluation specimens.Additionally,EBER in situ hybridization liquid cell controls were applied to the slides as evaluation references.A questionnaire was distrib-uted to collect staining information and methodologies from participating laboratories.Finally,the stained slides were collected and independently evaluated by pathology experts from the association according to predefined scoring criteria.Results A total of 38 pathology laboratories from 7 provinces and municipalities directly under the central government participated in the EQA,including 32 hospital pathology departments and 6 independent clinical laboratories.21 par-ticipants used manual staining,and others(17)used automated staining method by immunohistochemistry(IHC)stainers.The overall qualification rate of EBER in situ hybridization staining was 94.74%(36/38),and the excellent& good rate was 26.32%(10/38).The excellent & good rate of automated staining(41.12%,7/17)was significant-ly higher than that of manual staining(14.29%,3/21)(x2=4.852,P=0.028).The positive cell line control showed good consistency with the tissue control(Kappa=0.909,r=0.944).Conclusion The EBER in situ hybrid-ization technique in most of the pathology laboratories in the external quality assessment is qualified.There is a statisti-cally significant difference in the excellent & good rate between different staining methods.EBER in situ hybridization using automated IHC stainers is recommended as the preferred method.There is no difference in the performance of positive cell line control and tissue control.Some laboratories' staining techniques need to be improved.
2.Analysis of the results of external quality control for EBER in situ hybridization in 38 laboratories
Qing CAI ; Wenyang GUO ; Xiaowei XUE ; Detian WANG ; Xianbo WANG ; Weixun ZHOU
Chinese Journal of Clinical and Experimental Pathology 2025;41(7):918-923
Purpose The results of EBER in situ hybridization on the external quality assessment(EQA)organ-ized by the pathology Equipment Branch of the China Association of Medical Equipment were analyzed,for providing technical support for the standardization and normalization of the technology.Methods Paraffin-embedded sections of confirmed EBV-positive diffuse large B-cell lymphoma were selected as the evaluation specimens.Additionally,EBER in situ hybridization liquid cell controls were applied to the slides as evaluation references.A questionnaire was distrib-uted to collect staining information and methodologies from participating laboratories.Finally,the stained slides were collected and independently evaluated by pathology experts from the association according to predefined scoring criteria.Results A total of 38 pathology laboratories from 7 provinces and municipalities directly under the central government participated in the EQA,including 32 hospital pathology departments and 6 independent clinical laboratories.21 par-ticipants used manual staining,and others(17)used automated staining method by immunohistochemistry(IHC)stainers.The overall qualification rate of EBER in situ hybridization staining was 94.74%(36/38),and the excellent& good rate was 26.32%(10/38).The excellent & good rate of automated staining(41.12%,7/17)was significant-ly higher than that of manual staining(14.29%,3/21)(x2=4.852,P=0.028).The positive cell line control showed good consistency with the tissue control(Kappa=0.909,r=0.944).Conclusion The EBER in situ hybrid-ization technique in most of the pathology laboratories in the external quality assessment is qualified.There is a statisti-cally significant difference in the excellent & good rate between different staining methods.EBER in situ hybridization using automated IHC stainers is recommended as the preferred method.There is no difference in the performance of positive cell line control and tissue control.Some laboratories' staining techniques need to be improved.
3.Protective effects of lead collars on the thyroid in radiotherapy after breast cancer surgery
Xuemei CHEN ; Xiaobo JIANG ; Fuqiang CHEN ; Jiawei WU ; Weixun CAI ; Meijuan ZHOU
Chinese Journal of Radiological Health 2022;31(1):1-5
Objective :
To investigate the protective effects of different types of lead collars on the thyroid during radio-
therapy after breast-conserving surgery.
Methods:
Forty breast cancer patients undergoing radiotherapy after breast-con-
serving surgery were randomly divided into four groups to wear different lead collars for thyroid protection: control group (0 mm Pb), common material group (0.5 mm Pb), common material group (2 mm Pb), and new radiation-shielding material group (2 mm Pb). Radiation doses inside and outside lead collars were monitored. A questionnaire survey was conducted to acquire information on patient acceptance of the lead collars.
Results:
All the groups (except the control group) showed
significant differences between scattered radiation doses inside and outside lead collars (P < 0.05). The scattered radiation was attenuated by 33.64% on average in the 2-mm new material group, which was significantly higher than in the other groups (P < 0.05). After radiotherapy, there was no significant change in the color and appearance of skin under lead collars in any group. All the patients were normal at the first thyroid ultrasound re-examination. The 2-mm new material lead collar was the most acceptable.
Conclusion
The lead collar made of the new radiation-shielding material has a good protective
effect on the thyroid gland, and is easily accepted by patients, which can be promoted for application.
4.The 462nd case: chronic watery diarrhea and acute kidney injury
Yuehui NI ; Ji LI ; Weixun ZHOU ; Yaping LUO ; Qingwei JIANG ; Yang LIU ; Cai YUE ; Gang SUN ; Jiaming QIAN
Chinese Journal of Internal Medicine 2018;57(4):309-312
A 60-year-old man presented with severe watery diarrhea for 2 months complicated with weight loss and acute kidney injury.He did not respond well to antidiarrheal medicines,empirical antibiotics and dietary exclusion of gluten or even complete bowel rest.The final diagnosis of autoimmune enteropathy (AIE) was made based on histopathologic findings of endoscopic biopsy from duodenal mucosa after excluding neoplastic disease,inflammatory bowel disease,and infectious diarrhea,etc.Chronic diarrhea and oliguria alleviated after the administration of corticosteroids.

Result Analysis
Print
Save
E-mail