1.Evaluation of the Degree of Fibrosis in Chronic Kidney Disease via Clinical Radiomics Nomogram Prediction Model
Xiaomin HU ; Weihan XIAO ; Xuebin LIU ; Chaoxue ZHANG ; Xiachuan QIN
Chinese Journal of Medical Imaging 2025;33(3):331-336
Purpose To explore the value of the clinical radiomics nomogram based on ultrasound in evaluating the degree of fibrosis in chronic kidney disease(CKD).Materials and Methods This retrospective study included 350 patients with CKD in Nanchong Central Hospital from January 2014 to July 2022 who underwent renal biopsy.The patients were categorized by the tubule atrophy with interstitial fibrosis(TA/IF)and divided into a training cohort(n=245)and test cohort(n=105).The patient demographics were evaluated to establish a clinical prediction model.The XGBoost machine learning model was constructed by extracting the radiomics features from the ultrasound images.The clinical radiomics nomogram prediction model was constructed by combining the radiomics score(Rad score)and important clinical features.The diagnostic performance of the three models was evaluated using receiver operating characteristic curve analysis.Results Among the 350 patients with CKD,226 had TA/IF 0 and 124 had TA/IF 1.Based on the clinical characteristics and Rad score,the clinical radiomics nomogram prediction model had the highest area under the curve in the training and testing cohorts,with the area under the curve of 0.938(95%CI 0.909-0.969)and 0.933(95%CI 0.891-0.980),respectively.Conclusion The ultrasound-based radiomics prediction model has potential value for the noninvasive diagnosis of TA/IF in CKD.Nomogram prediction models based on renal Rad scores and clinic may help clinicians to manage patients.
2.Evaluation of the Degree of Fibrosis in Chronic Kidney Disease via Clinical Radiomics Nomogram Prediction Model
Xiaomin HU ; Weihan XIAO ; Xuebin LIU ; Chaoxue ZHANG ; Xiachuan QIN
Chinese Journal of Medical Imaging 2025;33(3):331-336
Purpose To explore the value of the clinical radiomics nomogram based on ultrasound in evaluating the degree of fibrosis in chronic kidney disease(CKD).Materials and Methods This retrospective study included 350 patients with CKD in Nanchong Central Hospital from January 2014 to July 2022 who underwent renal biopsy.The patients were categorized by the tubule atrophy with interstitial fibrosis(TA/IF)and divided into a training cohort(n=245)and test cohort(n=105).The patient demographics were evaluated to establish a clinical prediction model.The XGBoost machine learning model was constructed by extracting the radiomics features from the ultrasound images.The clinical radiomics nomogram prediction model was constructed by combining the radiomics score(Rad score)and important clinical features.The diagnostic performance of the three models was evaluated using receiver operating characteristic curve analysis.Results Among the 350 patients with CKD,226 had TA/IF 0 and 124 had TA/IF 1.Based on the clinical characteristics and Rad score,the clinical radiomics nomogram prediction model had the highest area under the curve in the training and testing cohorts,with the area under the curve of 0.938(95%CI 0.909-0.969)and 0.933(95%CI 0.891-0.980),respectively.Conclusion The ultrasound-based radiomics prediction model has potential value for the noninvasive diagnosis of TA/IF in CKD.Nomogram prediction models based on renal Rad scores and clinic may help clinicians to manage patients.
3.Content Determination of Sinomenine in Qihuang Capsule by HPLC
Yong YANG ; Weizao LUO ; Xuming LIANG ; Weihan QIN ; Dashuang QING ; Dejiang WANG ; Ying WANG
China Pharmacy 2015;(30):4243-4244
OBJECTIVE:To establish a method for the content determination of sinomenine in Qihuang capsule. METHODS:HPLC was performed on the column of welch C18-AQ with mobile phase of methanol-phosphate buffer(gradient elution) at flow rate of 1.0 ml/min,detection wavelength was 264 nm,column temperature was 30 ℃ and volume injection was 10 μl. RESULTS:The linear range of sinomenine was 0.200 3-10.016 0 μg(r=0.999 8),RSDs of precision,stability and reproducibility tests were lower than 1.0%,recovery was 98.80%-100.94%(RSD=0.79%,n=6). CONCLUSIONS:The method is simple,accurate and re-producible,and can be used for the content determination of sinomenine in Qihuang capsule.

Result Analysis
Print
Save
E-mail