1.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
2.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
3.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
4.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
5.Pregnancy outcomes of patients with positive anticentromere antibodies receiving in vitro fertilization-embryo transfer
Yuqing TIAN ; Yi'er ZHOU ; Yuhang FAN ; Sufeng CHEN ; Xiaoyan GUO ; Yiqi YU ; Xiangli WU ; Weihai XU ; Jing SHU
Journal of Zhejiang University. Medical sciences 2024;53(3):342-350
Objective:To analyze the pregnancy outcomes in patients with positive anti-centromere antibodies(ACA)receiving in vitro fertilization(IVF)-embryo transfer(ET)and natural conception.Methods:A case-control study was used to retrospectively analyze the clinical data of 3955 patients who received IVF-ET therapy and had the results of antinuclear antibody(ANA)spectrum at Zhejiang Provincial People's Hospital from June 2016 to June 2023.Patients with positive ACA and negative ACA were matched at a ratio of 1∶3 using propensity score matching.Embryo outcomes of IVF were compared between the two groups,and the impact of different fertilization methods and the use of immunosuppressants on pregnancy outcomes were analyzed using self-matching.The natural conception and disease progress were followed up for ACA-positive patients after IVF failure.Results:The ACA-positive patients accounted for 0.86%of all IVF patients(34/3955)and 2.51%of total ANA-positive IVF patients.Regardless of whether patients received conventional IVF(c-IVF)or intracytoplasmic sperm injection(ICSI),the ACA-positive group exhibited significant differences in oocyte maturity and fertilization compared to the ACA-negative group(both P<0.01).Moreover,the ACA-positive group had a decreased number of D3 suboptimal embryos and D3 optimal embryos(both P<0.05).In 5 cases of ACA-positive patients who underwent ICSI cycles,the two pronucleus(2PN)rate did not increase compared to c-IVF cycles(P>0.05),and there was a decrease in the number of D3 high-quality embryos and D3 suboptimal embryos(both P<0.05).After 1-2 months of immuno-suppressant treatment,12 ACA-positive patients underwent c-IVF/ICSI again,and there were no changes in egg retrieval and fertilization before and after medication(both P>0.05),but there was an improvement in the 2PN embryo cleavage rate(P<0.05).The number of embryos transferred was similar between the ACA-positive and negative groups,but the ACA-positive group had significantly lower embryo implantation rate and clinical pregnancy rate compared to the ACA-negative group(both P<0.05),with no significant differences in the miscarriage rate between the two groups(P>0.05).Twenty-seven ACA-positive patients attempted natural conception or artificial insemination after IVF failure,resulting in a total of 7 cases of clinical pregnancy.Conclusions:Serum ACA positivity may disrupt oocyte maturation and normal fertilization processes,with no improvement observed with ICSI and immunosuppressant use.However,ACA-positive patients may still achieve natural pregnancy.
6.Bendamustine combined with pomalidomide and dexamethasone in relapsed multiple myeloma with extramedullary disease: a multicenter study.
Hong Ying WU ; Xia ZHOU ; Xiao Xia CHU ; Xiu Zhi DENG ; Cheng Lu YUAN ; Xue Hong RAN ; Guo Qiang LIU ; Chuan Bo FAN ; Hong Yuan HAO ; Yu Ping ZHONG
Chinese Journal of Hematology 2023;44(8):667-671
Objective: To evaluate the efficacy and safety of bendamustine combined with pomalidomide and dexamethasone (BPD regimen) in the treatment of relapsed multiple myeloma (MM) with extramedullary disease. Methods: This open, single-arm, multicenter prospective cohort study included 30 relapsed MM patients with extramedullary disease diagnosed in seven hospitals including Qingdao Municipal Hospital. The patients were treated with BPD regimen from February 2021 to November 2022. This study analyzed the efficacy and adverse reactions of the BPD regimen. Results: The median age of the 30 patients was 62 (47-72) years, of which 18 (60% ) had first-time recurrence. The overall response rate (ORR) of the 18 patients with first-time recurrence was 100%, of which three (16.7% ) achieved complete remission, 10 (55.5% ) achieved very good partial remission (VGPR), and five (27.8% ) achieved partial remission (PR). The ORR of 12 patients with recurrence after second-line or above treatment was 50%, including zero patients with ≥VGPR and six patients (50% ) with PR. Three cases (25% ) had stable disease, and three cases (25% ) had disease progression. The one-year progression free survival rate of all patients was 65.2% (95% CI 37.2% -83.1% ), and the 1-year overall survival rate was 90.0% (95% CI 76.2% -95.4% ). The common grade 3-4 hematology adverse reactions included two cases (6.7% ) of neutropenia and one case (3.3% ) of thrombocytopenia. The overall adverse reactions are controllable. Conclusions: The BPD regimen has good efficacy and tolerance in relapsed MM patients with extramedullary disease.
Humans
;
Middle Aged
;
Aged
;
Multiple Myeloma/drug therapy*
;
Bendamustine Hydrochloride/therapeutic use*
;
Prospective Studies
;
Dexamethasone/therapeutic use*
;
Antineoplastic Combined Chemotherapy Protocols/therapeutic use*
7.Formulation optimization and analysis of taste-masking effect of licorzine granules based on sensory evaluation and electronic tongue method
Li-min WANG ; Shu-ye QI ; Wei-feng ZHANG ; Peng SHEN ; Bao-ming NING ; Da-yong SHI ; Xue-ping WU ; Jie YANG
Acta Pharmaceutica Sinica 2023;58(11):3191-3197
Licorzine granules are common preparations for children zinc deficiency. Considering the long course of treatment, the taste of licorzine granules may become a main factor affecting medication adherence. To date there have been no taste evaluation research into licorzine granules yet. In this study, both sensory evaluation and electronic tongue method were utilized to optimize licorzine granules formulations, evaluate the tastes of licorzine, excipients, optimized formulation
8.Comparative study on the methods to determine disintegration time of oral soluble films
Di GAO ; Guo-xiang LI ; Shu-ye QI ; Xue-ping WU ; Chao-qiang XIAO ; Shu-wang HE ; Jie YANG ; Wei-feng ZHANG
Acta Pharmaceutica Sinica 2023;58(11):3204-3209
Disintegration time is a key parameter that affects the palatability and compliance of oral soluble films. At present, there is no standard method to determine the disintegration time of oral soluble films. In this study, we compared the six methods (pharmacopoeial disintegration method, petri dish method, sponge surface method, slide frame and ball method, partially immersed into liquid (without weight attached) and partially immersed into liquid (with weight attached)) to determine the
9.Antiviral and Antibacterial Effect of Chicoric Acid: A Review
Chao WU ; Junqiang LI ; Xiaojuan CONG ; Yuan GAO ; Fei YU ; Yanyu LYU ; Min YANG ; Jian LI ; Shuai FENG ; Feng LI
Chinese Journal of Experimental Traditional Medical Formulae 2022;28(24):220-228
Chicoric acid, a hydroxycinnamic acid with the molecular formula C22H18O12, is an important active ingredient in Taraxacum mongolicum, Echinacea purpurea, Cichorium intybus and other natural plants, and it helps plants protect themselves from insects and infection from viruses, bacteria, fungi, and nematodes. Modern pharmacological research suggests that chicoric acid has significant bioactivities such as anti-inflammatory, antioxidant, immune-regulating, antibacterial, antiviral and anti-tumor properties. The first reported bioactivity of chicoric acid is its inhibitory effect on human immunodeficiency virus (HIV). With the development and application of molecular biology and related technologies, the inhibitory activities of chicoric acid on other viruses as well as its mechanism of action have been frequently reported. Another study indicates that chicoric acid has significant inhibitory effects on different pathogenic bacteria. This paper summarized the research progress on the antiviral and antibacterial effects of chicoric acid through a comprehensive review of relevant literature in China and abroad in the past 20 years. Studies have shown that chicoric acid has significant inhibitory activities against various viruses such as HIV, hepatitis B virus (HBV), respiratory syncytial virus (RSV), and herpes simplex virus (HSV), as well as different pathogenic bacteria such as Staphylococcus aureus, Yersinia enterocolitica and Mycobacterium tuberculosis. This study is expected to provide references for in-depth research on chicoric acid against pathogenic microorganisms and antiviral and antibacterial study of traditional Chinese medicine.
10.Analysis on the infection source of the first local cluster epidemic caused by the VOC/Gamma variant of SARS-CoV-2 in China.
Yang YU ; Ji Yu ZHANG ; Hai MA ; Yang HAN ; Li Xiao CHENG ; Xue Ying TIAN ; Ju Long WU ; Yan LI ; Yu Wei ZHANG ; De Ying CHEN ; Ji Zhao LI ; Jin Bo ZHANG ; Ze Xin TAO ; Zeng Qiang KOU ; Aiqiang XU
Chinese Journal of Preventive Medicine 2022;56(12):1789-1794
Objective: To investigate a SARS-CoV-2 epidemic reported in Rongcheng City, Weihai, Shandong Province. Methods: The SARS-CoV-2 nucleic acid positive patients and their close contacts were investigated, and the whole genome sequencing and genetic evolution analysis of 9 variant viruses were carried out. An infection source investigation and analysis were carried out from two sources of home and abroad, and three aspects of human, material and environment. Results: A total of 15 asymptomatic infections were reported in this epidemic, including 13 cases as employees of workshop of aquatic products processing company, with an infection rate of 21.67% (13/60). Two cases were infected people's neighbors in the same village (conjugal relation). The first six positive persons were processing workers engaged in the first process of removing squid viscera in the workshop of the company. The nucleic acid Ct value of the first time were concentrated between 15 and 29, suggesting that the virus load was high, which was suspected to be caused by one-time homologous exposure. The whole genome sequence of 9 SARS-CoV-2 strains was highly homologous, belonging to VOC/Gamma (Lineage P.1.15). No highly homologous sequences were found from previous native and imported cases in China. It was highly homologous with the six virus sequences sampled from May 5 to 26, 2021 uploaded by Chile. The infection source investigation showed that the company had used the squid raw materials captured in the ocean near Chile and Argentina from May to June 2021 over the last 14 days. Many samples of raw materials, products and their outer packages in the inventory were tested positive for nucleic acid. Conclusion: This epidemic is the first local epidemic caused by the VOC/Gamma of SARS-CoV-2 in China. It is speculated that the VOC/Gamma, which was prevalent in South America from May to June 2021, could be imported into China through frozen squid.
Humans
;
SARS-CoV-2
;
COVID-19
;
Epidemics
;
China/epidemiology*

Result Analysis
Print
Save
E-mail