1.Prediction and diagnosis of immune checkpoint inhibitor-related adverse eventsnoma cells via matrix metalloproteinase-9
Chinese Journal of Cancer Biotherapy 2025;31(8):793-798
[摘 要] 以免疫检查点抑制剂(ICI)为主的免疫治疗在激活T细胞、解除免疫抑制的同时可诱发免疫相关不良反应(irAE)。随着ICI在实体瘤中的广泛应用,irAE已成为临床常见问题,严重影响免疫治疗持续获益和患者生活质量。因此,应用ICI前需进行患者基线评估,如对有自身免疫性疾病、器官移植、病毒感染等特殊人群评估获益与风险。同时,irAE的预测及早期识别很重要,应结合临床因素,如基础性疾病、既往用药及治疗史;宿主因素,如肠道菌群及特定基因多态性;以及生物标志物,包括肿瘤突变负荷、炎症指标、自身抗体等综合预测irAE。此外,irAE的早期症状,如乏力、咳嗽、胆红素升高、转氨酶升高等需要与感染、肿瘤进展、非ICI相关的不良反应鉴别。irAE属于排除性诊断,还需借助影像、病理及多学科会诊等手段鉴别。积极开展irAE的机制研究及前瞻性临床试验有助于推动irAE的精准预测与治疗发展。
2.Simplified all-arthroscopic Broström technique in treatment of chronic lateral ankle instability in adolescents.
Xiancheng HUANG ; Sufen YE ; Canfeng LI ; Yong LUO ; Jiatong LI ; Mingyang ZOU ; Tian YOU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(4):457-461
OBJECTIVE:
To investigate effectiveness of simplified all-arthroscopic Broström technique in treatment of chronic lateral ankle instability in adolescents.
METHODS:
A clinical data of 21 adolescent patients with chronic lateral ankle instability, who met the selection criteria and were admitted between June 2023 and May 2024, was retrospectively analyzed. There were 18 males and 3 females with an average age of 16.0 years (range, 13-18 years). There were 9 cases of left ankle joint injury and 12 cases of right ankle joint injury. Anterior talofibular ligament (ATFL) injury was diagnosed by arthroscopy in all patients. There were 11 cases of cartilage injury, 5 cases of avulsion fractures, and 6 cases of ankle impingement syndrome. The time from first sprain to operation ranged from 3-60 months (mean, 12.0 months). The ATFL was repaired and the ankle joint stability was restored by simplified all-arthroscopic Broström technique. Visual analogue scale (VAS) score, Tegner score, American Orthopaedic Foot and Ankle Society (AOFAS) score, Karlsson ankle function scale (KAFS) score, Foot and Ankle Outcome Score (FAOS) were used to evaluate ankle pain and function. MRI was used to evaluate the ligament healing.
RESULTS:
All patients were followed up 8-15 months (mean, 12.6 months). After operation, 1 patient suffered from superficial peroneal nerve injury, 1 patient developed anterior scar impingement on the ankle, 2 patients had superficial wound infection, and 1 patient suffered from sprain again. The VAS score, Tenger score, AOFAS score, KAFS score, and FAOS score significantly improved when compared with the preoperative scores ( P<0.05). MRI examination showed the ligament healing and good tension.
CONCLUSION
For adolescent patients with chronic lateral ankle instability, using simplified all-arthroscopic Broström technique to repair ATFL can effectively alleviate ankle pain, improve stability, and achieve good effectiveness.
Humans
;
Joint Instability/surgery*
;
Male
;
Adolescent
;
Female
;
Arthroscopy/methods*
;
Ankle Joint/physiopathology*
;
Retrospective Studies
;
Ankle Injuries/surgery*
;
Lateral Ligament, Ankle/injuries*
;
Treatment Outcome
;
Chronic Disease
;
Range of Motion, Articular
3.Single-cell transcriptomic analysis reveals immune dysregula-tion and macrophage reprogramming in diabetic foot ulcers.
Chunli HUANG ; Yu JIANG ; Wei JIAO ; Ying SUI ; Chunlei WANG ; Yongtao SU
Journal of Zhejiang University. Medical sciences 2025;54(5):602-610
OBJECTIVES:
To elucidate the underlying mechanisms of macrophage-mediated inflammation and tissue injury in diabetic foot ulcer (DFU).
METHODS:
Skin tissue samples were collected from patients with DFU and with non-DFU. A total of 79 272 high-quality cell transcriptomes were obtained using single-cell RNA sequencing. An unbiased clustering approach was employed to identify cell subpopulations. Seurat functions were used to identify differentially expressed genes between DFU and non-DFU groups, and gene ontology (GO) enrichment analysis was used to reveal gene function. Furthermore, cell-cell communication network construction and ligand-receptor interaction analysis were performed to reveal the mechanisms underlying cellular interactions and signaling regulation in the DFU microenvironment from multiple perspectives.
RESULTS:
The results revealed a significant expansion of myeloid cells in DFU tissues, alongside a marked reduction in structural cells such as endothelial cells, epithelial cells, and smooth muscle cells. Major cell types underwent functional reprogramming, characterized by immune activation and impaired tissue remodeling. Specifically, macrophages in DFU skin tissues exhibited a shift toward a pro-inflammatory M1 phenotype, with upregulation of genes associated with inflammation and oxidative stress. Cell communication analysis further demonstrated that M1 macrophages served as both primary signal receivers and influencers in the COMPLEMENT pathway mediated communication network, and as key signal senders and mediators in the secreted phosphoprotein 1 (SPP1) pathway mediated communication network, actively shaping the inflammatory microenvironment. Key ligand-receptor interactions driving macrophage signaling were identified, including C3-(ITGAM+ITGB2) and SPP1-CD44.
CONCLUSIONS
This study establishes a comprehensive single-cell atlas of DFU, revealing the role of macrophage-driven cellular networks in chronic inflammation and impaired healing. These findings may offer potential novel therapeutic targets for DFU treatment.
Humans
;
Macrophages/immunology*
;
Diabetic Foot/pathology*
;
Single-Cell Analysis
;
Transcriptome
;
Gene Expression Profiling
;
Inflammation
;
Skin
;
Cell Communication
;
Signal Transduction
;
Cellular Reprogramming
4.Expert consensus on the diagnosis and treatment of cemental tear.
Ye LIANG ; Hongrui LIU ; Chengjia XIE ; Yang YU ; Jinlong SHAO ; Chunxu LV ; Wenyan KANG ; Fuhua YAN ; Yaping PAN ; Faming CHEN ; Yan XU ; Zuomin WANG ; Yao SUN ; Ang LI ; Lili CHEN ; Qingxian LUAN ; Chuanjiang ZHAO ; Zhengguo CAO ; Yi LIU ; Jiang SUN ; Zhongchen SONG ; Lei ZHAO ; Li LIN ; Peihui DING ; Weilian SUN ; Jun WANG ; Jiang LIN ; Guangxun ZHU ; Qi ZHANG ; Lijun LUO ; Jiayin DENG ; Yihuai PAN ; Jin ZHAO ; Aimei SONG ; Hongmei GUO ; Jin ZHANG ; Pingping CUI ; Song GE ; Rui ZHANG ; Xiuyun REN ; Shengbin HUANG ; Xi WEI ; Lihong QIU ; Jing DENG ; Keqing PAN ; Dandan MA ; Hongyu ZHAO ; Dong CHEN ; Liangjun ZHONG ; Gang DING ; Wu CHEN ; Quanchen XU ; Xiaoyu SUN ; Lingqian DU ; Ling LI ; Yijia WANG ; Xiaoyuan LI ; Qiang CHEN ; Hui WANG ; Zheng ZHANG ; Mengmeng LIU ; Chengfei ZHANG ; Xuedong ZHOU ; Shaohua GE
International Journal of Oral Science 2025;17(1):61-61
Cemental tear is a rare and indetectable condition unless obvious clinical signs present with the involvement of surrounding periodontal and periapical tissues. Due to its clinical manifestations similar to common dental issues, such as vertical root fracture, primary endodontic diseases, and periodontal diseases, as well as the low awareness of cemental tear for clinicians, misdiagnosis often occurs. The critical principle for cemental tear treatment is to remove torn fragments, and overlooking fragments leads to futile therapy, which could deteriorate the conditions of the affected teeth. Therefore, accurate diagnosis and subsequent appropriate interventions are vital for managing cemental tear. Novel diagnostic tools, including cone-beam computed tomography (CBCT), microscopes, and enamel matrix derivatives, have improved early detection and management, enhancing tooth retention. The implementation of standardized diagnostic criteria and treatment protocols, combined with improved clinical awareness among dental professionals, serves to mitigate risks of diagnostic errors and suboptimal therapeutic interventions. This expert consensus reviewed the epidemiology, pathogenesis, potential predisposing factors, clinical manifestations, diagnosis, differential diagnosis, treatment, and prognosis of cemental tear, aiming to provide a clinical guideline and facilitate clinicians to have a better understanding of cemental tear.
Humans
;
Dental Cementum/injuries*
;
Consensus
;
Diagnosis, Differential
;
Cone-Beam Computed Tomography
;
Tooth Fractures/therapy*
6.Human Cytomegalovirus Infection and Embryonic Malformations: The Role of the Wnt Signaling Pathway and Management Strategies.
Xiao Mei HAN ; Bao Yi ZHENG ; Zhi Cui LIU ; Jun Bing CHEN ; Shu Ting HUANG ; Lin XIAO ; Dong Feng WANG ; Zhi Jun LIU
Biomedical and Environmental Sciences 2025;38(9):1142-1149
Human cytomegalovirus (HCMV) poses a significant risk of neural damage during pregnancy. As the most prevalent intrauterine infectious agent in low- and middle-income countries, HCMV disrupts the development of neural stem cells, leading to fetal malformations and abnormal structural and physiological functions in the fetal brain. This review summarizes the current understanding of how HCMV infection dysregulates the Wnt signaling pathway to induce fetal malformations and discusses current management strategies.
Humans
;
Cytomegalovirus Infections/virology*
;
Wnt Signaling Pathway
;
Pregnancy
;
Female
;
Cytomegalovirus/physiology*
;
Pregnancy Complications, Infectious/virology*
;
Congenital Abnormalities/virology*
;
Animals
7.A Potential Novel Targeted Drug for the Treatment of Pulmonary Arterial Hypertension:Imatinib
Shanshan XIE ; Ye LI ; Lingling YU ; Jinjin WAN ; Zhiying HUANG ; Huanyu LIN ; Weifang ZHANG
Herald of Medicine 2024;43(2):262-266
Pulmonary hypertension has a high mortality rate,and although targeted therapy is available,it is still incurable,and the long-term prognosis for patients is poor.As a tyrosine kinase inhibitor,imatinib was approved for marketing in China in 2002 for the treatment of chronic myelogenous leukemia and other tumor diseases.In addition to the antitumor effects,imatinib was found to improve hemodynamics and exercise tolerance in patients with severe pulmonary arterial hypertension,but the safety was suboptimal.With the emergence of new formulations of imatinib targeted at the lungs,it is expected to become a new targeted drug for pulmonary arterial hypertension.
8.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
9.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
10.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.

Result Analysis
Print
Save
E-mail