1.In vitro biocompatibility of graded glass infiltrated ultra-translucent zirconia
Qiya ZHANG ; Yixiang TONG ; Shijiao YANG ; Yumeng ZHANG ; Ling DENG ; Wei WU ; Yao XIE ; Jian LIAO ; Ling MAO
Chinese Journal of Tissue Engineering Research 2026;30(2):443-450
BACKGROUND:In previous studies,glass materials were infiltrated into 5Y-PSZ ultra-translucent zirconia by a double sintering method to prepare 5Y-PSZ-YGI graded glass infiltrated ultra-translucent zirconia materials that can maintain high transparency and high flexural strength.OBJECTIVE:To evaluate the in vitro biocompatibility of 5Y-PSZ-YGI graded glass infiltrated ultra-translucent zirconia materials.METHODS:(1)Glass materials were infiltrated into 5Y-PSZ ultra-translucent zirconia by double sintering to prepare 5Y-PSZ-YGI graded glass infiltrated ultra-translucent zirconia.5Y-PSZ-YGI graded glass infiltrated ultra-translucent zirconia(or 5Y-PSZ ultra-translucent zirconia,3Y-TZP transparent zirconia)was placed in DMEM culture medium containing 10%fetal bovine serum for 12,24 and 72 hours,and the surface area ratio of culture medium to sample was 3 mL/cm2,and the 12-,24-and 72-hour material extracts were obtained.(2)After culturing mouse fibroblast L929 for 24 hours,the original culture medium was discarded and divided into 7 groups for culture:the control group was replaced with DMEM culture medium containing 10%fetal bovine serum by volume,and the other 6 groups were replaced with 24-hour extract of 3Y-TZP transparent zirconia,24-hour extract of 5Y-PSZ ultra-translucent zirconia,24-hour extract of 5Y-PSZ-YGI graded glass infiltrated ultra-translucent zirconia,72-hour extract of 3Y-TZP transparent zirconia,72-hour extract of 5Y-PSZ ultra-translucent zirconia,and 72-hour extract of 5Y-PSZ-YGI graded glass infiltrated ultra-translucent zirconia.After 1,3,and 5 days of culture,cell growth was observed under a microscope,and the cell proliferation rate was obtained by CCK-8 assay to determine cytotoxicity.(3)Human anticoagulated blood was mixed with 5Y-PSZ-YGI graded glass infiltrated ultra-translucent zirconia,5Y-PSZ ultra-translucent zirconia,and 3Y-TZP transparent zirconia,and the hemolysis rate was detected after 0.5 hours.Human anticoagulated blood was mixed with 12-hour extract of 3Y-TZP transparent zirconia,12-hour extract of 5Y-PSZ ultra-translucent zirconia,and 12-hour extract of 5Y-PSZ-YGI graded glass infiltrated ultra-translucent zirconia,and the hemolysis rate was detected after 0.5 hours.RESULTS AND CONCLUSION:(1)Under the microscope,it could be seen that the number of cells in each group increased with the extension of culture time,and the cell morphology of each experimental group was basically the same as that of the control group.The cytotoxicity grade of the 24-hour extract of 3Y-TZP transparent zirconia group on the first day of culture was grade 0,and the cytotoxicity grade of the other experimental groups at each time period was grade 1.(2)Neither the material nor the material extract caused obvious hemolytic reaction,and the hemolytic rate was less than 5%.(3)The results showed that 5Y-PSZ-YGI graded glass infiltrated ultra-translucent zirconia had no significant effect on the growth and proliferation of mouse fibroblasts L929,and did not cause hemolytic reaction with human blood,and had good in vitro biocompatibility.
2.Influenza prediction and holiday effects analysis based on Prophet-LSTM model
Wenlin CHENG ; Junjun MAO ; Yizhe WANG ; Jiabing WU
Journal of Public Health and Preventive Medicine 2026;37(1):8-12
Objective To investigate the impact of holiday effects and prevention/control measures on the development characteristics and incidence trends of influenza in Hefei City using a Prophet-LSTM hybrid model, and to validate the applicability of the Prophet-LSTM model in influenza prediction by comparing the performance of different forecasting models. Methods Influenza incidence data from Hefei City (2016–2024) were collected to construct a Prophet-LSTM feature analysis and prediction model to analyze the impact of holiday effects and intervention measures on influenza incidence trends. Comparative models (ARIMA, GRU, and TimeGPT) were established and evaluated on the same test set. Results The data analysis revealed significantly increased influenza incidence during holidays (e.g., New Year's Day, Spring Festival, and National Day), while prevention and control measures led to declining trends. The Prophet-LSTM model demonstrated high consistency between the predicted and actual values, outperforming the comparative models with superior MAE (0.209), MSE (0.195), and IA (0.914), indicating higher prediction accuracy and trend-fitting capability. Conclusion The Prophet-LSTM model effectively captures spatiotemporal characteristics of influenza incidence, exhibits enhanced predictive performance when incorporating holiday effects and intervention measures, and demonstrates significant advantages and application value in influenza forecasting.
3.In vitro biocompatibility of graded glass infiltrated ultra-translucent zirconia
Qiya ZHANG ; Yixiang TONG ; Shijiao YANG ; Yumeng ZHANG ; Ling DENG ; Wei WU ; Yao XIE ; Jian LIAO ; Ling MAO
Chinese Journal of Tissue Engineering Research 2026;30(2):443-450
BACKGROUND:In previous studies,glass materials were infiltrated into 5Y-PSZ ultra-translucent zirconia by a double sintering method to prepare 5Y-PSZ-YGI graded glass infiltrated ultra-translucent zirconia materials that can maintain high transparency and high flexural strength.OBJECTIVE:To evaluate the in vitro biocompatibility of 5Y-PSZ-YGI graded glass infiltrated ultra-translucent zirconia materials.METHODS:(1)Glass materials were infiltrated into 5Y-PSZ ultra-translucent zirconia by double sintering to prepare 5Y-PSZ-YGI graded glass infiltrated ultra-translucent zirconia.5Y-PSZ-YGI graded glass infiltrated ultra-translucent zirconia(or 5Y-PSZ ultra-translucent zirconia,3Y-TZP transparent zirconia)was placed in DMEM culture medium containing 10%fetal bovine serum for 12,24 and 72 hours,and the surface area ratio of culture medium to sample was 3 mL/cm2,and the 12-,24-and 72-hour material extracts were obtained.(2)After culturing mouse fibroblast L929 for 24 hours,the original culture medium was discarded and divided into 7 groups for culture:the control group was replaced with DMEM culture medium containing 10%fetal bovine serum by volume,and the other 6 groups were replaced with 24-hour extract of 3Y-TZP transparent zirconia,24-hour extract of 5Y-PSZ ultra-translucent zirconia,24-hour extract of 5Y-PSZ-YGI graded glass infiltrated ultra-translucent zirconia,72-hour extract of 3Y-TZP transparent zirconia,72-hour extract of 5Y-PSZ ultra-translucent zirconia,and 72-hour extract of 5Y-PSZ-YGI graded glass infiltrated ultra-translucent zirconia.After 1,3,and 5 days of culture,cell growth was observed under a microscope,and the cell proliferation rate was obtained by CCK-8 assay to determine cytotoxicity.(3)Human anticoagulated blood was mixed with 5Y-PSZ-YGI graded glass infiltrated ultra-translucent zirconia,5Y-PSZ ultra-translucent zirconia,and 3Y-TZP transparent zirconia,and the hemolysis rate was detected after 0.5 hours.Human anticoagulated blood was mixed with 12-hour extract of 3Y-TZP transparent zirconia,12-hour extract of 5Y-PSZ ultra-translucent zirconia,and 12-hour extract of 5Y-PSZ-YGI graded glass infiltrated ultra-translucent zirconia,and the hemolysis rate was detected after 0.5 hours.RESULTS AND CONCLUSION:(1)Under the microscope,it could be seen that the number of cells in each group increased with the extension of culture time,and the cell morphology of each experimental group was basically the same as that of the control group.The cytotoxicity grade of the 24-hour extract of 3Y-TZP transparent zirconia group on the first day of culture was grade 0,and the cytotoxicity grade of the other experimental groups at each time period was grade 1.(2)Neither the material nor the material extract caused obvious hemolytic reaction,and the hemolytic rate was less than 5%.(3)The results showed that 5Y-PSZ-YGI graded glass infiltrated ultra-translucent zirconia had no significant effect on the growth and proliferation of mouse fibroblasts L929,and did not cause hemolytic reaction with human blood,and had good in vitro biocompatibility.
4.Analysis of risk factors for sodium valproate-induced hyperammonemia in neurocritical patients and construction of risk prediction model
Wan XU ; Jin WU ; Jiaojiao MAO ; Jingjing MA ; Yao FEI
China Pharmacy 2026;37(8):1039-1044
OBJECTIVE To investigate the risk factors for sodium valproate (VPA)-induced hyperammonemia in neurocritical patients, and to construct a risk prediction model. METHODS Clinical data were retrospectively collected from 172 neurocritical patients who received VPA treatment in the Department of Critical Care Medicine, the Fourth Affiliated Hospital of Soochow University from January 2022 to June 2025. Patients were divided into the hyperammonemia group (73 cases) and the normal group (99 cases) based on their blood ammonia levels. Univariate analysis and LASSO regression analysis were used to screen for predictive variables. Independent factors were identified through multivariate Logistic regression analysis, and a nomogram was constructed accordingly. The performance of the model was evaluated using receiver operating characteristic (ROC) curve, calibration curve, and decision curve analysis (DCA). RESULTS Combination of univariate analysis and LASSO regression analysis screened out seven predictive variables: body mass index (BMI)≥24.0 kg/m 2 , concomitant use of benzodiazepines, VPA blood concentration, hemoglobin, serum urea, average daily VPA dose, and albumin. Multivariate Logistic regression analysis showed that concomitant use of benzodiazepines, BMI≥24.0 kg/m 2 , VPA blood concentration, albumin and serum urea level (with odds ratios of 1.615, 1.538, 1.623, 1.942 and 0.637, respectively; 95% confidence intervals of 1.128-2.359, 1.059-2.251, 1.112-2.431, 1.106-3.598 and 0.402-0.980, respectively) were all significantly associated with VPA-induced hyperammonemia in neurocritical patients ( P <0.05). The nomogram prediction model constructed based on these variables was evaluated, showing that the area under the ROC curve was 0.810 for the test set and 0.844 for the validation set. The calibration curves closely approximated t he actual curves, and the application of this model could improve the clinical net benefit. CONCLUSIONS Concomitant use of benzodiazepines, BMI≥24.0 kg/m 2 , high VPA blood concentration and high albumin level are independent risk factors for VPA-induced hyperammonemia in neurocritical patients, while high serum urea level is an independent protective factor. The risk prediction model constructed based on these factors exhibits good discrimination, consistency, and clinical applicability, making it applicable for predicting the risk of VPA-induced hyperammonemia in neurocritical patients.
5.Comparative Analysis of Clinical Efficacy of Traditional Chinese Medicine Manipulative Reduction Combined with Small Splint Fixation Versus Surgical Treatment for Type A Distal Radius Fracture
Yang SHAO ; Zihan WANG ; Jianwei WANG ; Guoda DAI ; Hengyan CUI ; Zhen HUA ; Tingchen ZHU ; Shaoshuo LI ; Jun MAO ; Fenghua CHEN ; Shuai TAO ; Mao WU
Journal of Traditional Chinese Medicine 2026;67(10):1078-1085
ObjectiveTo compare the clinical efficacy of traditional Chinese medicine (TCM) manipulative reduction combined with small splint fixation versus surgical treatment for type A distal radius fracture (DRF) and to explore the factors influencing the choice of treatment. MethodsA multi-center retrospective study was conducted, collecting data from 1237 type A DRF patients treated in 11 hospitals in Jiangsu province from September, 2023 to April, 2025. Among them, 851 patients in the TCM group received manipulative reduction combined with small splint fixation, and 386 patients in the surgical group underwent open reduction and internal fixation. Visual analog scale (VAS) scores for pain and radiographic indicators including palmar tilt, ulnar deviation, and radial height were compared before treatment, 5-7 days after treatment, and 4-6 weeks after treatment. The wrist joint function scores including Dienst and Gartland-Werley scores at 12 weeks after treatment were recorded. Subgroup analysis was conducted for the excellent rate of Dienst and Gartland-Werley scores, stratified by age (<50, 50-59, 60-69, ≥70 years old) and AO subtypes (A1, A2, A3). A multivariate logistic regression model was used to identify independent factors influencing treatment choice. ResultsOn 5-7 days after treatment, the surgical group had lower VAS scores than the TCM group, while 4-6 weeks after treatment, the TCM group showed lower VAS scores than the surgical group (P<0.01). In terms of radiographic indicators, except for the palmar tilt before treatment being higher in the surgical group than in the TCM group (P<0.01), there were no significant differences in palmar tilt, ulnar deviation, and radial height at other timepoints (P>0.05). Twelve weeks after treatment, the surgical group had a higher average Gartland-Werley score and the excellent rate than the TCM group (P<0.01). Subgroup analysis showed that in patients with A2 type DRF aged 50-59 and 60-69 years old, the excellent rates of Dienst and Gartland-Werley scores in the TCM group were higher than those in the surgical group (P<0.05). Multivariate logistic regression analysis revealed that age, palmar tilt, ulnar deviation, and the degree of swelling on the affected side were independent factors influencing the choice of treatment (P<0.05). ConclusionBoth TCM manipulative reduction combined with small splint fixation and surgical treatment for type A DRF can achieve good therapeutic effects. TCM manipulative reduction combined with small splint fixation has certain advantages in medium- and long-term pain relief, especially in elderly patients, where wrist joint function recovery is more stable. Age, palmar tilt, ulnar deviation, and swelling degree are the main factors influencing the treatment choice.
6.Clinical Efficacy and Radiographic Outcomes of Manipulative Reduction Combined with Small Splint Fixation for Distal Radius Fractures:A Retrospective Multicenter Study with Propensity Score Matching
Mao WU ; Guoda DAI ; Yang SHAO ; Shaoshuo LI ; Zhen HUA ; Hengyan CUI ; Tingchen ZHU ; Dipeng LI ; Jintao LIU ; Ming ZHOU ; Peimin WANG ; Liyong ZHANG ; Jianwei WANG
Journal of Traditional Chinese Medicine 2026;67(10):1086-1092
ObjectiveTo observe the clinical efficacy and radiographic outcomes of manipulative reduction combined with small splint fixation in the treatment of distal radius fractures. MethodsThe clinical data of 1051 patients with distal radius fractures were retrospectively collected from five hospitals included in the Jiangsu Diagnosis and Treatment Data Platform for Traditional Chinese Medicine(TCM) Dominant Diseases. Propensity score matching at a 1∶4 ratio was applied, resulting in 580 cases selected for final analysis, which comprised 448 patients in the TCM group(manipulative reduction plus small splint fixation) and 132 in the surgical treatment group(open reduction and internal fixation). Each group was further stratified into type A, B, and C subgroups based on AO fracture classification. Radiographic indicators including palmar tilt, radial inclination, and radial height were compared between groups before treatment and 1 day, 1 week, and 4-6 weeks after treatment, and pain visual analog scale(VAS) scores before treatment and 1 week and 4-6 weeks after treatment were also compared. Wrist joint function was assessed 12 weeks after treatment, using the Dienst wrist function score and the Gartland and Werley(G-W) wrist function score. Additionally, the radiographic indicators at different timepoints and the 12-week wrist function levels were compared between groups across different fracture types. ResultsNo statistically significant difference was observed in radiographic indicators and VAS scores at all timepoints before and after treatment, as well as wrist joint function grades assessed by the Dienst score and the G-W score at 12 weeks after treatment (P>0.05). Compared to those before treatment, both groups showed increased palmar tilt, radial inclination, and radial height 1 week and 4-6 weeks after treatment, and decreased VAS scores (P<0.05). Compared to those 1 week after treatment, both groups showed a decrease in palmar tilt, an increase in radial inclination and radial height, and a reduction in VAS score 4-6 weeks after treatment(P<0.05). In type A and B subgroups, the surgical treatment group had a higher radial inclination than the TCM group 4-6 weeks after treatment, while in the type C subgroup, a higher radial height was shown in the surgical treatment group than in the TCM group 4-6 weeks after treatment(P<0.05). In type C subgroup, there was significant difference between groups in the wrist joint function by G-W scores 12 weeks after treatment(P<0.05). ConclusionManipulative reduction combined with small splint fixation can maintain fracture alignment and alleviate pain in treating distal radius fractures, which achieves therapeutic outcomes comparable to surgical treatment. It is particularly suitable for type A and B fractures and can be considered an effective treatment option for distal radius fractures.
7.Construction and Clinical Validation of a Deep Learning-Based Automatic Measurement Model for Palmar Tilt and Radial Inclination in Distal Radius Fractures
Guoda DAI ; Jianwei WANG ; Mao WU ; Bin KANG ; Yang SHAO ; Hengyan CUI ; Shaoshuo LI ; Tingchen ZHU ; Zhen HUA ; Zhongming SHEN ; Jintao LIU ; Ming ZHOU
Journal of Traditional Chinese Medicine 2026;67(10):1093-1100
ObjectiveTo construct an automatic measurement model for palmar tilt and radial inclination suitable for traditional Chinese medicine (TCM) clinical scenarios, and to validate its accuracy and efficiency in TCM manipulative reduction settings. MethodsData on anteroposterior (AP) and lateral X-rays of distal radius fractures were collected from patients admitted to 18 TCM/ integrated TCM and western medicine hospitals in Jiangsu province between September 1st, 2023, and September 1st, 2024, via the Jiangsu Diagnosis and Treatment Big Data Platform for TCM Dominant Diseases. A medical image segmentation framework based on multi-scale feature fusion and edge-awareness was employed, combined with anatomical knowledge specific to TCM orthopedics, to optimize the feature extraction strategy of an artificial intelligence (AI) model. This framework enabled automatic segmentation of fracture regions and measurement of distal radius palmar tilt and radial inclination. The accuracy of the AI model in measuring radial inclination and volar tilt was validated, and the measurement time and average time gain rate of the AI model were compared to those of manual measurement. ResultsA total of 15,444 AP and lateral X-ray images of distal radius fractures were collected, and were divided into a training set (11,144 images, 5066 AP and 6078 lateral), a validation set (3700 images, 1840 AP and 1860 lateral), and an independent test set (600 images, 300 AP and 300 lateral) after preprocessing. In the measurement of 300 AP X-rays in the independent test set for radial inclination, when the degree error between AI measurement and manual measurement was <3° and <5°, AI measurement accuracy was 83% and 93%, respectively. In 300 lateral X-rays in the test set for palmar tilt, when AI measurements had an error of <3° and <5° compared to manual measurements, corresponding accuracy rate was 78% and 90%, respectively. For 50 X-ray images, AI measurement time was (1.37±0.05) min for radial inclination while manual measurement time was (22.57±2.52) min (P<0.001); in terms of palmar tilt, the AI measurement time was (1.33±0.14) min, shorter than (23.70±2.80) min for manual measurement time (P<0.001). Average time gain rates for manual and AI measurements were 93.93% and 94.39% respectively. ConclusionAn automatic measurement model for palmar tilt and radial inclination in distal radius fractures has been established, enabling more accurate and efficient assessment as well as providing a tool to support the quantitative evaluation of the efficacy of TCM manipulative reduction and large-sample clinical research.
8.Association of polychlorinated biphenyl exposure with platelet parameters across different glycemic states: The moderating role of a healthy lifestyle
Zhuo CHEN ; Huilin LOU ; Taimeng CHEN ; Fangyuan LIN ; Xueyan WU ; Yao GUO ; Haoran XU ; Mengke CHENG ; Peihan CHEN ; Yilin ZHOU ; Zhenxing MAO ; Xin TANG
Journal of Environmental and Occupational Medicine 2026;43(5):535-541
Background Platelet parameters are important indicators of cardiovascular risk, and environmental pollutants such as polychlorinated biphenyls (PCBs) may impair platelet function through oxidative stress. Objective To investigate the differential effects of single and mixed exposure to PCBs on platelet parameters among individuals with normal glucose tolerance (NGT), impaired fasting glucose (IFG), and type 2 diabetes mellitus (T2DM), and to evaluate the potential modifying role of a healthy lifestyle. Methods This study included 2249 participants (including 707 with NGT, 759 with IFG, and 783 with T2DM). Plasma PCB concentrations were measured using triple quadrupole gaschromatography-tandem mass spectrometry. Generalized linear regression was used to assess the associations between individual PCB congeners and platelet parameters. Quantile g-computation (QGC) and Bayesian kernel machine regression (BKMR) models were used to evaluate the overall effects of PCBs mixture exposure on platelet parameters across different glycemic states, as well as its interaction with healthy lifestyle score (HLS). Results Generalized linear regression analyses showed significant differences in the effects of PCBs on platelet parameters across different glycemic states (P<0.05). After adjusting for confounders, PCBs mixture exposure was significantly associated with lower platelet counts (PLT) in individuals with NGT (b=−10.60, 95%CI: −16.48, −4.71) and IFG (b=−12.91, 95%CI: −18.90, −6.92), whereas no significant association was observed in individuals with T2DM (P=0.051). Mean platelet volume (MPV) and platelet-large cell ratio (P-LCR) increased significantly with higher PCBs exposure levels across all three groups (P<0.05). BKMR analysis showed a positive association between PCBs mixture exposure and P-LCR, with the strongest association observed in the NGT group. Furthermore, a significant interaction was observed between HLS and PCBs mixture exposure, and a higher HLS attenuated the effects of PCBs on P-LCR. Conclusion Glycemic glycemic states may modify the effects of PCBs on platelets. Individuals with NGT appear more sensitive to PCBs exposure, whereas the T2DM state may attenuate this effect. Moreover, healthy lifestyles, including not smoking, moderate alcohol consumption, maintaining moderate-to-high physical activity, a healthy diet, and an appropriate body mass index (BMI), may mitigate the adverse effects of most PCBs on platelet parameters.
9.Association of polychlorinated biphenyl exposure with platelet parameters across different glycemic states: The moderating role of a healthy lifestyle
Zhuo CHEN ; Huilin LOU ; Taimeng CHEN ; Fangyuan LIN ; Xueyan WU ; Yao GUO ; Haoran XU ; Mengke CHENG ; Peihan CHEN ; Yilin ZHOU ; Zhenxing MAO ; Xin TANG
Journal of Environmental and Occupational Medicine 2026;43(5):535-541
Background Platelet parameters are important indicators of cardiovascular risk, and environmental pollutants such as polychlorinated biphenyls (PCBs) may impair platelet function through oxidative stress. Objective To investigate the differential effects of single and mixed exposure to PCBs on platelet parameters among individuals with normal glucose tolerance (NGT), impaired fasting glucose (IFG), and type 2 diabetes mellitus (T2DM), and to evaluate the potential modifying role of a healthy lifestyle. Methods This study included 2249 participants (including 707 with NGT, 759 with IFG, and 783 with T2DM). Plasma PCB concentrations were measured using triple quadrupole gaschromatography-tandem mass spectrometry. Generalized linear regression was used to assess the associations between individual PCB congeners and platelet parameters. Quantile g-computation (QGC) and Bayesian kernel machine regression (BKMR) models were used to evaluate the overall effects of PCBs mixture exposure on platelet parameters across different glycemic states, as well as its interaction with healthy lifestyle score (HLS). Results Generalized linear regression analyses showed significant differences in the effects of PCBs on platelet parameters across different glycemic states (P<0.05). After adjusting for confounders, PCBs mixture exposure was significantly associated with lower platelet counts (PLT) in individuals with NGT (b=−10.60, 95%CI: −16.48, −4.71) and IFG (b=−12.91, 95%CI: −18.90, −6.92), whereas no significant association was observed in individuals with T2DM (P=0.051). Mean platelet volume (MPV) and platelet-large cell ratio (P-LCR) increased significantly with higher PCBs exposure levels across all three groups (P<0.05). BKMR analysis showed a positive association between PCBs mixture exposure and P-LCR, with the strongest association observed in the NGT group. Furthermore, a significant interaction was observed between HLS and PCBs mixture exposure, and a higher HLS attenuated the effects of PCBs on P-LCR. Conclusion Glycemic glycemic states may modify the effects of PCBs on platelets. Individuals with NGT appear more sensitive to PCBs exposure, whereas the T2DM state may attenuate this effect. Moreover, healthy lifestyles, including not smoking, moderate alcohol consumption, maintaining moderate-to-high physical activity, a healthy diet, and an appropriate body mass index (BMI), may mitigate the adverse effects of most PCBs on platelet parameters.
10.Effect of storage conditions on long-term preservation of PRP growth factors
Qing QI ; Zhaojie LI ; Qiong WU ; Pingping MAO ; Yangzi SUN ; Jianfeng LUAN ; Shujun WANG
Chinese Journal of Blood Transfusion 2025;38(6):759-765
Objective: To compare the changes in the concentration of relevant growth factors released from platelet-rich plasma (PRP) stored at -80℃ by cryopreservation and at 4℃ by refrigerated lyophilization over 2 years, aiming to provide a theoretical basis for prolonging PRP storage duration. Methods: PRP (n=15) was separated using a blood cell separator and stored under -80℃ cryopreservation (F-PRP group) and 4℃ refrigerated freeze-drying conditions (FD-PRP group). The contents of growth factors (PDGF-AA, PDGF-BB, EGF, TGF-β1, and VEGF) in both groups were measured by ELISA at 1, 3, 6, 9, 12 and 24 months. Results: PDGF-AA and VEGF maintained good stability in both groups for up to 24 months. PDGF-BB and TGF-β1 showed high stability in the first 12 months but their stability decreased gradually from 12th to 24th months. EGF demonstrated good stability in the first 6 months, and its stability gradually decreased from the 9th to 24th months. Comparing the F-PRP and FD-PRP groups, the concentrations of the five growth factors in the FD-PRP group were either not statistically different or higher than those in the F-PRP group at all time points. Specifically, the concentrations of EGF were significantly higher in the FD-PRP group at all time points. Conclusion: Both -80℃ freezing and 4℃ freeze-drying enable long-term preservation of PRP. Freeze-drying imposes less stringent storage requirements and facilitates growth factor compared to frozen storage.


Result Analysis
Print
Save
E-mail