1.Nomogram-based predictive model for intra-myometrial contrast agent reflux using imaging features from 4D hysterosalpingo-contrast sonography.
Xia YANG ; Liangying PAN ; Xingping ZHAO ; Jingjia YI ; Lin WANG ; Baiyun ZHANG
Journal of Central South University(Medical Sciences) 2025;50(1):61-71
OBJECTIVES:
According to the World Health Organization (WHO), infertility rates have been steadily rising worldwide. Identifying risk factors for contrast agent reflux into the myometrium during hysterosalpingo-contrast sonography (HyCoSy) is of clinical significance in reducing this complication and improving infertility treatment. However, there is currently no standardized pre-evaluation method for predicting intra-myometrial contrast reflux, with clinical assessment often relying on physician experience and patient symptoms. This study aims to identify imaging risk factors for contrast agent reflux into the myometrium using four-dimensional (4D) HyCoSy and to construct a nomogram-based predictive model to assist in clinical decision-making.
METHODS:
A retrospective analysis was conducted on 1 274 infertile women who underwent 4D HyCoSy at the Women and Children's Hospital of Hunan and the the Third Xiangya Hospital of Central South University from January 1, 2020, to December 15, 2022. Patients were divided into a reflux group (n=234) and a non-reflux group (n=1 040) based on the presence of intra-myometrial contrast reflux. Univariate and multivariable Logistic regression analyses were used to identify significant predictors, which were then used to construct a nomogram model. Internal validation was performed using 500 bootstrap resamples.
RESULTS:
The age of the reflux group was significantly higher than that of the non-reflux group [(31.82±5.27) years vs (30.66±4.83) years, P=0.001 1]. Primary infertility was more common in the non-reflux group (50.96%), while secondary infertility dominated in the reflux group (76.50%), with 72.65% having a history of gynecological surgery (P<0.001). Abnormal menstrual volume and discomfort during the procedure were more common in the reflux group, while the non-reflux group tolerated higher contrast agent doses (P<0.001). Imaging differences included endometrial thickness, tubal wall smoothness, and peritoneal contrast dispersion, with the non-reflux group showing thicker endometrium and smoother, more patent tubes. The nomogram model yielded an area under the curve (AUC) of 0.854, indicating good predictive performance. The AUC of the decision curve analysis (DCA) for internal validation of the model was 0.737. When the threshold probability for contrast agent reflux into the myometrium ranged from 0.05 to 0.95, the maximum net benefit reached 0.18. The net benefit of applying the nomogram predictive model exceeded that of either full intervention or no intervention, indicating that the model demonstrates good clinical predictive performance.
CONCLUSIONS
The nomogram model, based on infertility type, endometrial thickness, contrast agent dose, and discomfort symptoms, effectively predicts intra-myometrial contrast agent reflux after 4D HyCoSy. It provides a valuable tool for clinicians to implement early preventive measures and reduce the risk of contrast leakage and associated complications.
Humans
;
Female
;
Nomograms
;
Contrast Media/adverse effects*
;
Retrospective Studies
;
Adult
;
Ultrasonography/methods*
;
Hysterosalpingography/methods*
;
Infertility, Female/diagnostic imaging*
;
Myometrium/diagnostic imaging*
;
Risk Factors
2.Predictive value of ultrasound-derived quantitative indicators of umbilical cord hypercoiling and hemodynamic parameters for adverse pregnancy outcomes.
Xiaotan TAN ; Qichang ZHOU ; Hongxia YUAN ; Da HOU ; Yunfang ZHU ; Ruji YAO
Journal of Central South University(Medical Sciences) 2025;50(7):1179-1187
OBJECTIVES:
The diagnostic value of ultrasonographic quantitative indicators of umbilical cord coiling, such as the umbilical coiling index (UCI) and pitch value, in identifying hypercoiling and predicting adverse pregnancy outcomes remains controversial. This study aims to evaluate the predictive value of UCI, pitch value, and the cerebroplacental ratio in pregnancies complicated by umbilical cord hypercoiling.
METHODS:
Pregnant women with densely coiled umbilical cords identified by routine obstetric ultrasound at Changsha Maternal and Child Health Hospital between November 2022 and November 2024 were enrolled. Complete clinical data, including UCI, pitch value, and cerebroplacental ratio (CPR), were collected. Pregnancy outcome scores were calculated, and newborns were categorized into the normal outcome group (n=177) and adverse outcome group (n=85), with the latter further subdivided into mild (n=51), moderate (n=19), and severe (n=15) subgroups. Differences in baseline data, UCI, pitch value, and incidence of CRP<1 were compared between groups and among subgroups. Correlations between UCI, pitch value, and adverse pregnancy outcomes were analyzed. Receiver operating characteristic (ROC) curve were used to assess the predictive performance of UCI, pitch value, CPR<1, and their combinations.
RESULTS:
Compared with the normal outcome group, the adverse outcome group had higher age, parity, parity, incidence of CPR<1, and UCI, while gestational age at delivery and pitch values were lower (all P<0.05). The incidence of obesity, gestational diabetes mellitus, and hypertensive disorders of pregnancy did not differ significantly between the 2 groups (all P>0.05). The normal outcome group showed lower UCI and higher pitch values than all 3 adverse outcome subgroups (all P<0.05), while differences among the 3 adverse subgroups were not significant (all P>0.05). UCI was positively correlated with adverse pregnancy outcomes (rs=0.350, P<0.05), whereas pitch value was negatively correlated (rs=-0.286, P<0.05). ROC curve analysis showed that the area under the curve (AUC) values for predicting adverse outcomes were 0.837 for UCI, 0.886 for pitch value, and 0.610 for CPR<1, with sensitivities of 77.6%, 82.4%, and 27.1% and specificities of 78.5%, 83.6%, and 94.9%, respectively. The combined UCI+CPR<1 and pitch value+CPR<1 models yielded AUCs of 0.841 and 0.886, with sensitivities of 78.8% and 81.2% and specificities of 78.5% and 84.2%, respectively. No significant differences were found between the AUCs of UCI and pitch value (P>0.05), but both outperformed CPR<1 alone (both P<0.001). The combined models showed no significant improvement over UCI or pitch value alone (both P>0.05), though both were superior to CPR<1 alone (both P<0.001).
CONCLUSIONS
Most umbilical cord hypercoiling cases had favorable outcomes, with UCI, pitch value, CPR<1 and their combinations demonstrating significant predictive value for adverse pregnancy outcomes.
Humans
;
Female
;
Pregnancy
;
Pregnancy Outcome
;
Adult
;
Ultrasonography, Prenatal/methods*
;
Umbilical Cord/diagnostic imaging*
;
Hemodynamics
;
Predictive Value of Tests
;
Infant, Newborn
;
ROC Curve
3.Interventional endosonography comes of age: an update on endoscopic ultrasonography-guided drainage and anastomosis procedures.
Tiing Leong ANG ; Christopher Jen Lock KHOR
Singapore medical journal 2025;66(8):420-425
Endoscopic ultrasonography (EUS) has progressed beyond diagnostic imaging to include EUS-guided tissue acquisition and EUS-directed therapies. This review provides an update on EUS-guided drainage and anastomotic procedures, and other therapeutic procedures. Today, EUS-guided drainage of symptomatic walled-off pancreatic fluid collections is the norm, with endoscopic necrosectomy as an adjunct. For high-risk surgical patients unsuitable for cholecystectomy, EUS-guided gallbladder drainage of acute cholecystitis is an option. Additionally, EUS-guided drainage of obstructed biliary and pancreatic ductal system can be performed as salvage procedures after unsuccessful endoscopic retrograde cholangiopancreatography (ERCP). Bariatric procedures such as Roux-en-Y gastric bypass alter the gastric anatomy, hindering access to the major papilla. This can be overcome by creating a conduit through the excluded stomach using EUS-directed transgastric ERCP. Gastric outlet obstruction and afferent loop syndrome can be treated using EUS-guided gastrojejunostomy. These therapeutic interventions are a major advancement in the field of interventional EUS, achieving significant clinical impact.
Humans
;
Endosonography/methods*
;
Drainage/methods*
;
Cholangiopancreatography, Endoscopic Retrograde/methods*
;
Ultrasonography, Interventional/methods*
;
Anastomosis, Surgical/methods*
4.Effect of ultrasound-guided foraminal electroacupuncture on spinal cord injury based on the Wnt/β-catenin signaling pathway.
Weixian WU ; Bin CHEN ; Jing LIU ; Li WANG ; Feizhen CHEN ; Yanling WU
Chinese Acupuncture & Moxibustion 2025;45(10):1442-1449
OBJECTIVE:
To observe the effects of ultrasound-guided foraminal electroacupuncture on neuronal apoptosis and motor function in rats with spinal cord injury (SCI), and to explore the potential underlying mechanisms.
METHODS:
Thirty-six SPF-grade Sprague-Dawley rats were randomly assigned to a sham operation group, a model group, and an ultrasound-guilded electroacupuncture group (electroacupuncture group), with 12 rats in each group. In the sham operation group, the spinal cord was exposed and then the incision was sutured without contusion. In the other two groups, SCI models were established using a modified Allen's impact method. On days 1, 3, 7, and 14 after modeling, the electroacupuncture group received electroacupuncture intervention at the T9/T10 and T10/T11 intervertebral foramen under ultrasound guidance, avoiding spinal cord injury. Stimulation parameters were dense-disperse wave at 2 Hz/100 Hz and 1-2 mA for each session. Following interventions on days 1, 3, 7, and 14, the Basso-Beattie-Bresnahan (BBB) score was assessed; the inclined plane test was used to assess hindlimb grip strength in rats. After the intervention, HE staining was used to observe spinal cord morphology; TUNEL staining was used to detect neuronal apoptosis; ELISA was used to measure the serum levels of interleukin (IL)-6, IL-1β, and tumor necrosis factor-alpha (TNF-α); Western blot was used to analyze the protein expression of Wnt-4, β-catenin, c-Myc, Bax, Bcl-2, and NeuN in spinal tissue; quantitative real-time PCR was used to detect the mRNA expression of Wnt-4, β-catenin, c-Myc, Bax, Bcl-2, and NeuN.
RESULTS:
Compared with the sham operation group, the model group showed significantly reduced BBB scores (P<0.05), and reduced inclined plane angles (P<0.05) at all time points. Compared with the model group, the electroacupuncture group exhibited increased BBB scores on days 3, 7, and 14 (P<0.05), and higher inclined plane angles on days 1, 3, 7, and 14 (P<0.05). Compared with the sham operation group, the model group showed disorganized spinal cord structure with increased inflammatory cells and necrotic neurons, higher number of apoptotic neurons in spinal tissue (P<0.05), elevated serum IL-6, IL-1β, and TNF-α levels (P<0.05), increased protein and mRNA expression of Wnt-4, β-catenin, c-Myc, and Bax (P<0.05), and decreased protein and mRNA expression of Bcl-2 and NeuN in spinal tissue (P<0.05). Compared with the model group, the electroacupuncture group had fewer inflammatory cells and apoptotic neurons in spinal tissue (P<0.05), reduced serum IL-6, IL-1β, and TNF-α levels (P<0.05), increased protein and mRNA expression of Wnt-4, β-catenin, Bcl-2, and NeuN (P<0.05), and decreased protein and mRNA expression of c-Myc and Bax in spinal tissue (P<0.05).
CONCLUSION
Ultrasound-guided foraminal electroacupuncture could improve motor function in rats with SCI, potentially by regulating the expression of molecules related to the Wnt-4/β-catenin signaling pathway to inhibit neuronal apoptosis and inflammatory responses.
Animals
;
Electroacupuncture/methods*
;
Spinal Cord Injuries/physiopathology*
;
Rats, Sprague-Dawley
;
Rats
;
Wnt Signaling Pathway
;
Male
;
Humans
;
Female
;
beta Catenin/metabolism*
;
Apoptosis
;
Ultrasonography
;
Tumor Necrosis Factor-alpha/genetics*
;
Spinal Cord/metabolism*
5.Genetic analysis of 74 fetuses terminated for skeletal dysplasia and evaluation of diagnostic performance of whole exome sequencing.
Jiashan LI ; Siying LIANG ; Yan MIAO ; Xiaoyu DU ; Meiyan HAN ; Wei ZHAO ; Nan JIANG ; Yingchao ZHOU
Chinese Journal of Medical Genetics 2025;42(7):869-882
OBJECTIVE:
To explore the genetic etiology of fetal skeletal dysplasia using whole exome sequencing (WES) and copy number variation sequencing (CNV-seq) techniques, and the feasibility of using WES as the first-tier method for such fetuses.
METHODS:
Seventy four fetuses with skeletal dysplasia detected by prenatal ultrasound at the Genetic Testing Center of the Women and Children's Hospital Affiliated to Qingdao University from January 2020 to August 2024 were selected as the study subjects. Fetal muscle and peripheral blood samples of the pregnant women and their spouses were collected and subjected to WES analysis. CNV-seq was carried out on all fetal muscle tissue samples. And the results were compared with the CNVs indicated by WES. Genetic etiologies were analyzed across different subtypes of skeletal dysplasia. And the feasibility of using WES as the first-tier genetic test for similar fetuses was assessed, in addition with a systematic cost-effectiveness analysis. This study was approved by the Medical Ethics Committee of the Hospital (Ethics No.: QFELL-YJ-2024-201).
RESULTS:
A total of 50 fetuses were diagnosed, which yielded a diagnostic rate of 67.57%. These included 6 chromosomal aneuploidies, 4 chromosomal CNVs and 40 monogenic disorders. The monogenic diseases had involved 46 variant sites in 23 pathogenic genes, among which 12 were unreported previously, including MYH3: c.735T>C, ALPL: c.1324C>T, NEK9: c.1973G>A, MAGEL2: c.2024_2025del, LMBR1: c.423+4914A>C, NEB: c.21273_21276del, COL1A1: c.2651G>C and c.2758G>C, ASPM: c.2473delinsGA, TBX5: c.704G>A, DYNC2H1: c.10893del, and DYNC2I2: c.1270C>T. Substantial concordance was reached between WES-derived CNV calls and CNV-seq findings. No clinically significant CNV was exclusively detected by CNV-seq. Cost-effectiveness modeling demonstrated that implementing WES as the first-tier genetic testing method could reduce the total expenditure when WES unit cost remained below 6.4 folds that of the CNV-seq.
CONCLUSION
Genetic variants including single nucleotide variations (SNV) of monogenic disorders, chromosomal aneuploidies and genomic CNVs are important causes for fetal skeletal dysplasia. WES is an accurate and efficient method for analyzing the etiology of fetal skeletal dysplasia, particularly in those with a family history of similar phenotype or maternal history of adverse pregnancies.
Humans
;
Exome Sequencing/methods*
;
Female
;
Pregnancy
;
DNA Copy Number Variations/genetics*
;
Genetic Testing/methods*
;
Prenatal Diagnosis/methods*
;
Adult
;
Male
;
Fetus
;
Bone Diseases, Developmental/diagnosis*
;
Ultrasonography, Prenatal
6.Application of chromosomal microarray analysis in the prenatal diagnosis of fetuses with isolated Congenital anomalies of the kidney and urinary tract.
Xiaoyu DU ; Yan MIAO ; Jiashan LI ; Siying LIANG ; Wei ZHAO ; Yingchao ZHOU ; Nan JIANG
Chinese Journal of Medical Genetics 2025;42(9):1033-1038
OBJECTIVE:
To explore the detection rate of copy number variations (CNVs) in fetuses with isolated Congenital anomalies of the kidney and urinary tract (CAKUT) and pregnancy outcomes in order to provide a basis for genetic counseling.
METHODS:
One hundred and eighty eight fetuses who underwent chromosomal microarray analysis (CMA) due to isolated CAKUT detected by prenatal ultrasonography at Qingdao Women and Children's Hospital from January 2021 to December 2024 were selected as the study subjects. According to the ultrasound findings, the fetuses were divided into 8 groups, including renal parenchymal dysplasia group, renal cystic dysplasia group, simple renal parenchymal echo enhancement group, abnormal development of renal collecting system group, duplicated kidney group, ectopic kidney group, horseshoe kidney group, and bladder/posterior urethral abnormalities group. The detection of CNVs was retrospectively analyzed, and the pregnant women were followed up to summarize their pregnancy outcomes. 2 test (or Fisher's exact probability method) was used to compare the CNV detection rates between the groups. This study was approved by the Medical Ethics Committee of the Qingdao Women and Children's Hospital (Ethics No.: QFELL-YJ-2025-85).
RESULTS:
Among the 188 fetuses with isolated CAKUT, 23 CNVs (12.23%) were detected, of which 13 cases (6.91%) were pathogenic and 10 cases were rated as variants of unknown significance (VOUS). Among the 8 groups, the three groups with the highest proportion were renal cystic dysplasia group, renal metaplasia group, and renal parenchymal dysplasia group. The detection rates of pathogenic CNVs in the three groups were 1.79% (1/56), 6.78% (4/59), and 16.67% (5/30), respectively, with statistically significant differences (P < 0.05). Parental verification was conducted on 12 fetuses detected with the CNVs, confirming that 2 cases were de novo and 10 were inherited from parents with a normal phenotype. After genetic counseling, the parents of 9 fetuses opted to terminate the pregnancy, while 11 chose to continue with the pregnancy, and 3 were lost to follow-up. At the time of last follow-up, the youngest offspring was 5 months old and the oldest was 3 years and 11 months old. One child had renal aplasia, and two were born with hydronephrosis, which have been cured through surgery. The remainders had no obvious abnormality with their growth and development.
CONCLUSION
CMA testing has important value for prenatal diagnosis of isolated CAKUT. In this study, the detection rate of pathogenic CNVs has increased sequentially in fetuses with renal cystic developmental abnormalities, renal collecting system developmental abnormalities, and renal parenchymal dysplasia, while there was no significant difference in the detection rate of CNVs. For fetuses with isolated CAKUT detected by prenatal ultrasound, CMA testing should be considered, and reasonable pregnancy decisions should be made based on the results of prenatal ultrasound and parental verification.
Humans
;
Female
;
Pregnancy
;
Prenatal Diagnosis/methods*
;
DNA Copy Number Variations/genetics*
;
Kidney/abnormalities*
;
Adult
;
Ultrasonography, Prenatal
;
Urogenital Abnormalities/diagnosis*
;
Microarray Analysis/methods*
;
Retrospective Studies
;
Urinary Tract/abnormalities*
;
Fetus
;
Pregnancy Outcome
;
Vesico-Ureteral Reflux
7.Chinese Expert Consensus on the Clinical Application of Ultrasound Screening for Gastric Cancer(2025 Edition).
Acta Academiae Medicinae Sinicae 2025;47(5):679-701
The five-year survival rate of gastric cancer in China is close to that in European and American countries but far lower than that in the Republic of Korea and Japan,which have established national gastric cancer screening systems.It is of great significance to build a high-quality gastric cancer screening system adaptive to China's national conditions.Due to the large number of people at risk of gastric cancer and uneven distribution of medical resources,it is still difficult for China to carry out a nationwide gastroscopy screening plan for gastric cancer.Gastric ultrasound,with painlessness,no radiation,and easy acceptance and popularization,could be used as one of the alternative methods for initial screening of gastric cancer.Based on two gastric ultrasound-related consensuses published in 2020,this consensus elaborates on the necessity,feasibility,and existing problems of conducting preliminary gastric cancer ultrasound screening in China by analyzing the gastric cancer screening strategies and the difficulties faced by nationwide gastric cancer screening.Furthermore,this consensus introduces the indications and contraindications of gastric ultrasound examination,requirements for the operator and the contrast agent,ultrasound standard section,essentials of scanning operations,and stomach ultrasound report and data system (Su-RADS) and proposes the relevant consensus opinions accordingly.After multiple rounds of discussions and voting by experts from multiple societies,a total of 17 consensus opinions have been formed on gastric ultrasound as a preliminary screening technique for gastric cancer,with the aim of standardizing the popularization of gastric ultrasound.In addition,the consensus calls for conducting nationwide multicenter prospective studies to improve the level of evidence and provide data support for the construction of a preliminary gastric cancer ultrasound screening system that is in line with China's national conditions.
Humans
;
China
;
Early Detection of Cancer/methods*
;
Mass Screening
;
Stomach/diagnostic imaging*
;
Stomach Neoplasms/diagnostic imaging*
;
Ultrasonography
8.Research Progress in Clinical Applications of Gastric Contrast-Enhanced Ultrasound.
Qiao-Yun ZHAO ; Chun-Quan ZHANG ; Liang-Yun GUO
Acta Academiae Medicinae Sinicae 2025;47(5):702-709
Gastric contrast-enhanced ultrasound is a non-invasive imaging method that uses oral gastrointestinal ultrasound contrast agents to fill the stomach cavity and display the structure and lesions of the stomach wall.In recent years,the development of contrast agents and the technological innovations of ultrasound equipment have boosted the unique advantages of this examination technique in the diagnosis of gastrointestinal diseases.Gastric contrast-enhanced ultrasound is becoming an important complementary examination means to gastroscopy and X-ray barium meal examination.In this paper,we summarize the clinical applications of gastric contrast-enhanced ultrasound at home and abroad in recent years and systematically analyze its clinical application value and limitations in six aspects:screening and staging of gastric cancer,differentiation and diagnosis of gastric tumors,diagnosis and follow-up of gastritis and gastric ulcers,assessment of gastric contents and gastric volume,evaluation of gastric emptying and gastric motility,and other special applications.
Humans
;
Contrast Media
;
Ultrasonography/methods*
;
Stomach/diagnostic imaging*
;
Stomach Neoplasms/diagnostic imaging*
9.Advances in Clinical Application of Gastric Contrast-Enhanced Ultrasound for Gastric Cancer.
Guan-Mo LIU ; Hua LIANG ; Yang GUI ; Jie LI ; Xin YE ; Wei-Ming KANG
Acta Academiae Medicinae Sinicae 2025;47(5):716-724
Gastric contrast-enhanced ultrasound includes oral contrast-enhanced ultrasound (OCUS) and double contrast-enhanced ultrasound (DCEUS),which can provide valuable clinical information about tumor morphology,vascular characteristics,and treatment responses.OCUS can clearly identify the gastric wall structure and the extent and depth of lesions by applying oral contrast agents.DCEUS,based on OCUS combined with venography,can display the anatomical and perfusion characteristics of lesions.In recent years,gastric contrast agents and imaging techniques have developed rapidly.However,the clinical application of gastric contrast-enhanced ultrasound is still in the developmental stage.This article reviews the clinical status of OCUS and DCEUS in the screening,diagnosis,staging,pathological typing,and treatment evaluation of gastric cancer.Studies have shown that gastric contrast-enhanced ultrasound has high sensitivity and specificity in the assessment of diagnosis and T-staging of gastric cancer.Furthermore,gastric contrast-enhanced ultrasound has the advantages of being cost-effective,convenient,non-invasive,free from radiation exposure,real-time,and easy to repeat.In the diagnosis and treatment of gastric cancer,it is expected to become one of the important imaging assessment tools.
Humans
;
Stomach Neoplasms/diagnostic imaging*
;
Contrast Media
;
Ultrasonography/methods*
10.Comparison of the Diagnostic Value of Transabdominal Intestinal Ultrasound and Magnetic Resonance Enterography for Intestinal Stenosis in Inflammatory Bowel Disease.
Kun WANG ; Yan-Jia GOU ; Li-Xue XU ; Wei-Ming KANG ; Dong LIU
Acta Academiae Medicinae Sinicae 2025;47(5):725-732
Objective To compare the diagnostic value of transabdominal intestinal ultrasound (IUS) and magnetic resonance enterography (MRE) for intestinal stenosis in inflammatory bowel disease (IBD). Methods A retrospective analysis was conducted on the imaging features of 51 IBD patients who underwent both IUS and MRE at Beijing Friendship Hospital,Capital Medical University,between January 2021 and February 2025.With endoscopy as the gold standard,the diagnostic performance of the two methods was compared. Results The sensitivity (84.2% vs. 52.6%,P=0.008) and accuracy (66.7% vs. 45.1%,P=0.035) of IUS for stenosis were higher than those of MRE.In the localization of stenosis,IUS demonstrated higher sensitivity than MRE for detecting stenosis in the terminal ileum (78.6% vs. 35.7%,P=0.070) and colorectum (86.7% vs. 53.3%,P=0.060).Furthermore,IUS showed higher diagnostic accuracy than MRE for terminal ileum stenosis (70.6% vs. 29.4%,P=0.039).The intestinal wall thickness[(8.2±2.7) mm vs. (10.3±3.8) mm;t=3.20,P=0.002)] and stenosis inner diameter[(3.0±1.6) mm vs. (4.3±1.8) mm;t=2.15,P=0.035] measured by IUS were lower than those measured by MRE,with a moderate level of consistency (ICC:0.19-0.53).In addition,IUS demonstrated a higher detection rate for mesenteric fat hypertrophy (70.6% vs. 27.5%,Kappa=0.27,P=0.005),whereas MRE was more sensitive in detecting lymphadenopathy (90.2% vs. 56.9%,Kappa=0.16,P=0.080). Conclusions IUS is superior to MRE in the diagnosis and localization sensitivity for intestinal stenosis in IBD.However,the two methods showcase poor consistency in detecting and quantitating some inflammatory signs.IUS can be used as a first-line screening method for diagnosing intestinal stenosis in IBD patients,while its clinical application should be combined with specific needs to optimize diagnosis.
Humans
;
Retrospective Studies
;
Constriction, Pathologic/diagnostic imaging*
;
Ultrasonography/methods*
;
Magnetic Resonance Imaging/methods*
;
Inflammatory Bowel Diseases/diagnostic imaging*
;
Male
;
Female
;
Adult
;
Middle Aged
;
Intestines/diagnostic imaging*
;
Sensitivity and Specificity

Result Analysis
Print
Save
E-mail