1.Second chance in fertility: a comprehensive narrative review of redo micro-TESE outcomes after initial failure.
Haitham ELBARDISI ; Emre BAKIRCIOGLU ; Wen LIU ; Darren KATZ
Asian Journal of Andrology 2025;27(3):409-415
When microdissection testicular sperm extraction (micro-TESE) fails, a redo procedure may be the only option for patients who want a biological child. However, there are many gaps of knowledge surrounding the procedure, which need to be addressed to help clinicians and patients make informed decisions. This review explores redo micro-TESE in the context of nonobstructive azoospermia (NOA). Literature was searched using Google Scholar, Medline, and PubMed. Search terms were "NOA" AND "second microdissection testicular sperm extractions" AND "redo microdissection testicles sperm extraction" AND "repeat microdissection testicular sperm extractions" AND "failed microdissection testicular sperm extractions" AND "salvage microdissection testicular sperm extractions". Only original articles in English were included. A total of nine articles were included, consisting of four retrospective and five prospective studies. The time gap between the first and second micro-TESE varied from 6 months to 24 months. Most of the included studies reported successful surgical sperm retrieval (SSR) in the second micro-TESE in the range of 10%-21%, except in one study where it reached 42%. It has not been presented any definitive information about the use of hormonal treatment or the benefit of varicocelectomy prior to the second micro-TESE. Patients with hypospermatogenesis and Klinefelter syndrome (KS) had the highest chance of success in redo surgery. In conclusion, redo micro-TESE following a negative procedure can lead to sperm recovery in 10%-21%. Patients with hypospermatogenesis and KS have a higher chance of success. There is no enough evidence to conclude which is the best hormonal stimulation if any before a redo surgery.
Humans
;
Male
;
Azoospermia/surgery*
;
Sperm Retrieval
;
Microdissection
;
Reoperation
;
Treatment Failure
;
Testis/surgery*
;
Treatment Outcome
2.Factors associated with prognosis and treatment failure in children with acute lymphoblastic leukemia.
Meng-Meng YIN ; Qun HU ; Ai-Guo LIU ; Ya-Qin WANG ; Ai ZHANG
Chinese Journal of Contemporary Pediatrics 2025;27(3):308-314
OBJECTIVES:
To explore the factors related to prognosis and treatment failure in children with acute lymphoblastic leukemia (ALL).
METHODS:
A retrospective study was conducted to collect and analyze clinical data of ALL children admitted to the Department of Pediatric Hematology at Tongji Hospital, Huazhong University of Science and Technology, from January 2012 to December 2019, with follow-up until June 2024.
RESULTS:
A total of 341 children with ALL were included. Among the 69 children with treatment failure, 55 (80%) experienced relapse, while 14 (20%) had non-relapse-related deaths, and no secondary tumors were observed. Initial WBC count ≥50×109/L, positive minimal residual disease, and severe adverse events were identified as independent risk factors for treatment failure (P<0.05). Among the 55 relapsed patients, early relapses were predominant (36%), and the primary site of relapse was the bone marrow (56%). Immunophenotyping (P=0.009), initial WBC count (P=0.011), and fusion genes (P=0.040) were associated with the timing of relapse. High-risk status, T-cell ALL, relapse, and severe adverse events were independent risk factors affecting long-term survival (P<0.05).
CONCLUSIONS
The prognosis of children with ALL is related to risk stratification, immunophenotyping, relapse status, and occurrence of severe adverse events. Among these factors, relapse is the primary cause of treatment failure. Actively preventing relapse may reduce the treatment failure rate and improve long-term survival.
Humans
;
Precursor Cell Lymphoblastic Leukemia-Lymphoma/therapy*
;
Male
;
Female
;
Child
;
Child, Preschool
;
Retrospective Studies
;
Prognosis
;
Treatment Failure
;
Adolescent
;
Infant
;
Risk Factors
3.Valve-in-valve transcatheter mitral valve replacement with SAPIEN 3 valve for bioprosthetic mitral valve failure: one-year outcomes in 26 patients.
Zechao RAN ; Lulu LIU ; Jun SHI ; Yuqiang WANG ; Tingqian CAO ; Siyu HE ; Xiaoting LI ; Yingqiang GUO
Journal of Zhejiang University. Medical sciences 2025;54(5):668-675
OBJECTIVES:
To evaluate the one-year outcomes of valve-in-valve transcatheter mitral valve replacement (ViV-TMVR) using SAPIEN 3 valve for treating mitral bioprosthetic valve failure.
METHODS:
A retrospective analysis was conducted on 26 patients with mitral bioprosthetic valve failure who underwent ViV-TMVR at West China Hospital, Sichuan University, between November 2022 and July 2024. The age of patients was 71.5 (64.5, 74.5) years, and 69.2% were female. Bioprosthetic valve failure occurred at (9.7±3.7) years after initial surgical implantation, with the most common failure mode being mixed stenosis and regurgitation (53.8%). The SAPIEN 3 valve was implanted via either a transseptal or transapical approach. Echocardiography was performed preoperatively, immediately post-procedure, and at 1 month, 6 months, and 1 year post-procedure. Outcomes included all-cause mortality, New York Heart Association (NYHA) functional class, Kansas City Cardiomyopathy Questionnaire (KCCQ)-12 score, and postoperative complications.
RESULTS:
The procedure was performed via the transseptal approach in 21 patients (80.8%) and the transapical approach in 5 patients (19.2%). All procedures were technically successful. No paravalvular leakage was observed immediately post-procedure, and mitral valve hemodynamics improved significantly. At the 1-year follow-up, 2 patients had died. Two patients (8.3% of survivors) were of NYHA functional class Ⅲ, and KCCQ-12 score improved to (88.4±14.6) points (both P<0.01). Echocardio-graphy at 1 year postoperatively showed significant reductions in peak mitral valve velocity [to (2.29±0.32) m/s] and mean transvalvular pressure gradient [to (9.5±3.5) mmHg, 1 mmHg=0.133 kPa] compared to baseline (both P<0.05). No moderate or severe mitral regurgitation or paravalvular leakage was observed. The proportion of patients with moderate-to-severe pulmonary hypertension decreased from 65.4% preoperatively to 13.0% at 1 year (P<0.05).
CONCLUSIONS
ViV-TMVR with the SAPIEN 3 valve for mitral biopro-sthetic valve failure is associated with high procedural success, significantly improved valve hemodynamics of the mitral value, alleviation of pulmonary hypertension, enhanced quality of life, and a low rate of complications at 1 year after the operation.
Humans
;
Female
;
Male
;
Retrospective Studies
;
Aged
;
Bioprosthesis
;
Heart Valve Prosthesis
;
Mitral Valve/surgery*
;
Heart Valve Prosthesis Implantation/methods*
;
Middle Aged
;
Prosthesis Failure
;
Treatment Outcome
;
Mitral Valve Insufficiency/surgery*
4.A Case of Endometrial Metastasis in Lung Adenocarcinoma after EGFR-TKIs Treatment Failure and Literature Review.
Fangqian SHEN ; Zuling HU ; Hua YANG ; Puyu LIU ; Yuju BAI ; Jianguo ZHOU ; Hu MA
Chinese Journal of Lung Cancer 2025;28(7):551-557
The incidence and mortality rates of lung cancer remain high, making it the leading cause of cancer-related deaths. In women, the predominant histological subtype is lung adenocarcinoma, commonly associated with epidermal growth factor receptor (EGFR) mutations, and EGFR-tyrosine kinase inhibitors (EGFR-TKIs) can significantly improve patient prognosis. Metastasis of primary lung cancer to the endometrium is extremely rare and is often misdiagnosed as a primary reproductive system tumor, and its occurrence indicates poor prognosis. This article reports a case of an advanced lung adenocarcinoma patient with EGFR mutation, who developed abnormal vaginal bleeding after EGFR-TKIs treatment failure, and biopsy confirmed endometrial metastasis. A review of similar cases is also presented.
.
Humans
;
Female
;
ErbB Receptors/metabolism*
;
Endometrial Neoplasms/genetics*
;
Lung Neoplasms/genetics*
;
Protein Kinase Inhibitors/therapeutic use*
;
Adenocarcinoma of Lung/drug therapy*
;
Treatment Failure
;
Middle Aged
;
Adenocarcinoma/genetics*
5.Risk factors and prognosis of first extubation failure in neonates undergoing invasive mechanical ventilation.
Mengyao WU ; Hui RONG ; Rui CHENG ; Yang YANG ; Keyu LU ; Fei SHEN
Journal of Central South University(Medical Sciences) 2025;50(8):1398-1407
OBJECTIVES:
Prolonged invasive mechanical ventilation is associated with increased risks of severe complications such as retinopathy of prematurity and bronchopulmonary dysplasia. Although neonatal intensive care unit (NICU) follow the principle of early extubation, extubation failure rates remain high, and reintubation may further increase the risk of adverse outcomes. This study aims to identify risk factors and short-term prognosis associated with first extubation failure in neonates, to provide evidence for effective clinical intervention strategies.
METHODS:
Clinical data of neonates who received invasive ventilation in the NICU of Children's Hospital of Nanjing Medical University from January 1, 2019, to December 31, 2021, were retrospectively collected. Neonates were divided into a successful extubation group and a failed extubation group based on whether reintubation occurred within 72 hours after the first extubation. Risk factors and short-term outcomes related to extubation failure were analyzed.
RESULTS:
A total of 337 infants were included, with 218 males (64.69%). Initial extubation failed in 34 (10.09%) infants. Compared with the successful extubation group, the failed extubation group had significantly lower gestational age [(31.37±5.14) weeks vs (34.44±4.07) weeks], age [2.5 (1.00, 8.25) h vs 5 (1.00, 22.00) h], birth weight [(1 818.97±1128.80) g vs (2 432.18±928.94) g], 1-minute Apgar score (6.91±1.90 vs 7.68±2.03), and the proportion of using mask oxygenation after extubation (21% vs 46%) (all P<0.05). Conversely, compared with the successful extubation group, the failed extubation group had significantly higher rates of vaginal delivery (59% vs 32%), caffeine use during mechanical ventilation (71% vs 38%), dexamethasone use at extubation (44% vs 17%), the highest positive end-expiratory pressure level within 72 hours post-extubation [6(5.00, 6.00) cmH2O vs 5 (0.00, 6.00) cmH2O] (1 cmH2O=0.098 kPa), the highest FiO2 within 72 hours post-extubation [(34.35±5.95)% vs (30.22±3.58)%], and duration of noninvasive intermittent positive pressure ventilation after extubation [0.5 (0.00, 42.00) hours vs 0 (0, 0) hours] (all P<0.05). Multivariate analysis identified gestational age <28 weeks (OR=5.570, 95% CI 1.866 to 16.430), age at NICU admission (OR=0.959, 95% CI 0.918 to 0.989), and a maximum FiO2≥35% within 72 hours post-extubation (OR=4.541, 95% CI 1.849 to 10.980) as independent risk factors for extubation failure (all P<0.05). Additionally, the failed extubation group exhibited significantly higher incidences of necrotizing enterocolitis grade II or above, moderate-to-severe bronchopulmonary dysplasia, severe bronchopulmonary dysplasia, retinopathy of prematurity, treatment abandonment due to poor prognosis, and discharge on home oxygen therapy (all P<0.05). Total hospital length of stay and total hospitalization costs were also significantly increased in the failed extubation group (all P<0.05).
CONCLUSIONS
Gestational age <28 weeks, younger age at NICU admission, and FiO2≥35% after extubation are high-risk factors for first extubation failure in neonates. Extubation failure markedly increases the risk of adverse clinical outcomes.
Humans
;
Infant, Newborn
;
Male
;
Female
;
Airway Extubation/adverse effects*
;
Risk Factors
;
Retrospective Studies
;
Respiration, Artificial/methods*
;
Intensive Care Units, Neonatal
;
Prognosis
;
Gestational Age
;
Bronchopulmonary Dysplasia
;
Infant, Premature
;
Treatment Failure
;
Intubation, Intratracheal
7.Drug resistance mutations among people living with HIV with treatment failure in Henan Province, China.
Jinjin LIU ; Zhaoyun CHEN ; Shuguang WEI ; Jie MA ; Xiaohua ZHANG ; Shuxian ZHAO ; Qingxia ZHAO ; Xuan YANG ; Yuanyuan LI ; Xuhui CHEN ; Yan SUN ; Yuqi HUO
Chinese Medical Journal 2023;136(22):2744-2746
8.Research progress on the influence of Modic changes on lumbar interbody fusion and its treatment measure.
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(8):1026-1030
OBJECTIVE:
To review the research progress of Modic changes and its influence on lumbar interbody fusion.
METHODS:
The domestic and foreign literature related to Modic changes and its influence on lumbar interbody fusion was extensively reviewed. The etiology of Modic changes was summarized, and the treatment measures of Modic changes on lumbar interbody fusion were discussed.
RESULTS:
The etiology of Modic changes is not clear, which may be related to mechanical factors, autoimmune factors, low toxic infection factors, and genetic factors. Modic changes may lead to fusion failure and cage subsidence after lumbar interbody fusion. Preoperative evaluation of endplate sclerosis, reduction of iatrogenic endplate injury, fine operating of intervertebral space, management of osteoporosis, and selection of appropriate cage can prevent or reduce fusion failure or cage subsidence.
CONCLUSION
Modic changes may lead to fusion failure and cage subsidence after lumbar interbody fusion, and active perioperative intervention of Modic changes is helpful to improve the clinical prognosis.
Humans
;
Lumbosacral Region/surgery*
;
Osteoporosis
;
Spinal Fusion
;
Treatment Failure
9.Three-dimensional-printed hemi-pelvic prosthesis for revision of aseptic loosening or screw fracture of modular hemi-pelvic prosthesis.
Xin LIU ; Yi LUO ; Xuanhong HE ; Jie WANG ; Zhuangzhuang LI ; Yuqi ZHANG ; Xin HU ; Minxun LU ; Fan TANG ; Yong ZHOU ; Li MIN ; Chongqi TU
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(10):1183-1189
OBJECTIVE:
To investigate the effectiveness of three-dimensional (3D)-printed hemi-pelvic prosthesis for revision of aseptic loosening or screw fracture of modular hemi-pelvic prosthesis.
METHODS:
Between February 2017 and January 2020, 11 patients with aseptic loosening or screw fracture of modular hemi-pelvic prosthesis were revised using 3D-printed hemi-pelvic prostheses. There were 7 males and 4 females with an average age of 44 years (range, 25-60 years). In the first operation, all patients underwent total tumor resection, modular hemi-pelvic prosthesis reconstruction, and autologous femoral head transplantation. According to the Enneking pelvic partition system, 8 cases were resected in zones Ⅰ+Ⅱ and 3 cases in zones Ⅰ+Ⅱ+Ⅲ. The interval from the initial operation to this revision ranged from 14.3-66.2 months, with an average of 35.8 months. The operation time, the amount of intraoperative bleeding, and the occurrence of complications were recorded. At 6 months after the first operation, before revision, and at last follow-up, the American Musculoskeletal Tumor Society (MSTS) score and Harris score were used to evaluate the recovery of lower limb function. The pain-free walking distance of patients without brace assistance was recorded at last follow-up. X-ray films were taken at 1 month after the first operation, before revision, and at 1 month after revision, the acetabulum position was assessed by the differences in weight arm and cup height between bilateral hip joints. At last follow-up, the digital X-ray tomography was taken to evaluate the prosthesis-bone integration and the occurrence of aseptic loosening.
RESULTS:
The operation time was 182.6-238.0 minutes (mean, 197.4 minutes). The amount of intraoperative bleeding was 400-860 mL (mean, 550.0 mL). All incisions healed by first intention with no infection, hip dislocation, nerve damage, or vascular-related adverse events. The MSTS score and Harris score at last follow-up were significantly higher than those at 6 months after the first operation and before revision ( P<0.05), while the score before revision was significantly lower than that at 6 months after the first operation ( P<0.05). At last follow-up, the patients were able to walk more than 1 000 meters painlessly without brace assistance. Imaging review showed that the difference of cup height at 1 month after revision was significantly lower than that at 1 month after the first operation and before revision, and at 1 month after the first operation than before revision operation, and the differences were significant ( P<0.05). There was no significant difference in the difference of weight arm among three time points ( P>0.05). All prostheses were well integrated, and no aseptic loosening of the prosthesis or screw fracture occurred.
CONCLUSION
Revision with 3D-printed hemi-pelvic prostheses benefited in reconstructing stable pelvic ring and natural bodyweight transmission for patients encountering the aseptic loosening or screw fracture of modular hemi-pelvic prosthesis. Early postoperative rehabilitation training can maximize the recovery of patient limb function, reduce pain during walking, and reduce the incidence of complications.
Male
;
Female
;
Humans
;
Adult
;
Arthroplasty, Replacement, Hip/methods*
;
Hip Prosthesis
;
Treatment Outcome
;
Prosthesis Failure
;
Fractures, Bone/surgery*
;
Retrospective Studies
;
Neoplasms
10.Total hip arthroplasty for post-firearm hip arthritis complicated by coloarticular fistula: A case report.
Ahmed M ABDELAAL ; Mohammad Kamal ABDELNASSER ; Mohamed Ma MOUSTAFA ; Ahmed Mohamed ALI ; Haisam ATTA ; Ahmed A KHALIFA
Chinese Journal of Traumatology 2023;26(6):369-374
Hip firearm injuries are rare injuries that could lead to serious complications, such as posttraumatic hip arthritis and coloarticular fistula. We report a case of a 25-year-old male who sustained a pelvic injury caused by a single bullet which led to a bilateral acetabular fracture, concomitant with a colon injury treated on an emergency basis by a diverting colostomy; acetabular fractures were treated conservatively by traction. After the patient recovered from the abdominal injury, he was presented with bilateral hip pain and limited motion; plain radiographs showed bilateral hip arthritis with proximal migration of the femoral head and bilateral acetabular defect classified as Paprosky type ⅢA. Reconstruction of the hips was performed using the same technique: impaction bone grafting for acetabular defect reconstruction and a reversed hybrid total hip arthroplasty (THA) 6 months apart. The patient presented with loosening of the left THA acetabular cup 3 years later, which was revised; then he presented with a discharging sinus from the left THA with suspicion of coloarticular fistula, which was confirmed using CT with contrast material. A temporary colostomy and fistula excision were performed, and a cement spacer was applied to the hip. After clearing the infection, a final revision THA for the left hip was performed. Treating post-firearm hip arthritis by THA is challenging, especially in the situation of neglected cases with the presence of an acetabular defect. Concomitant intestinal injury increases the risk of infection with the possibility of coloarticular fistula formation, which could present later. Working with a multidisciplinary team is paramount.
Male
;
Humans
;
Adult
;
Arthroplasty, Replacement, Hip
;
Firearms
;
Wounds, Gunshot/surgery*
;
Acetabulum/injuries*
;
Hip Fractures/surgery*
;
Arthritis/surgery*
;
Spinal Fractures/surgery*
;
Reoperation
;
Fistula/surgery*
;
Treatment Outcome
;
Follow-Up Studies
;
Prosthesis Failure
;
Retrospective Studies

Result Analysis
Print
Save
E-mail