1.Characterization of non-alcoholic fatty liver disease–related hepatocellular carcinoma on contrast-enhanced ultrasound with Sonazoid
Yi DONG ; Juan CHENG ; Yun-Lin HUANG ; Yi-Jie QIU ; Jia-Ying CAO ; Xiu-Yun LU ; Wen-Ping WANG ; Kathleen MÖLLER ; Christoph F. DIETRICH
Ultrasonography 2025;44(3):232-242
Purpose:
This study aimed to evaluate the contrast-enhanced ultrasound with Sonazoid (Sonazoid-CEUS) features of hepatocellular carcinoma (HCC) in patients with non-alcoholic fatty liver disease (NAFLD).
Methods:
In this retrospective study, patients who underwent surgical resection and were histopathologically diagnosed with NAFLD or cirrhosis-related HCC were included. All patients received Sonazoid-CEUS examinations within 1 week prior to hepatic surgery. The enhancement patterns of HCC lesions were evaluated and compared between the two groups according to the current World Federation for Ultrasound in Medicine and Biology guidelines. Multivariate logistic regression analysis was used to assess the correlations between Sonazoid-CEUS enhancement patterns and clinicopathologic characteristics.
Results:
From March 2022 to April 2023, a total of 151 patients with HCC were included, comprising 72 with NAFLD-related HCC and 79 with hepatitis B virus (HBV) cirrhosis–related HCC. On Sonazoid-CEUS, more than half of the NAFLD-related HCCs exhibited relatively early and mild washout within 60 seconds (54.2%, 39/72), whereas most HBV cirrhosis–related HCCs displayed washout between 60 and 120 seconds (46.8%, 37/79) or after 120 seconds (39.2%, 31/79) (P<0.001). In the patients with NAFLD-related HCC, multivariate analysis revealed that international normalized ratio (odds ratio [OR], 0.002; 95% confidence interval [CI], 0.000 to 0.899; P=0.046) and poor tumor differentiation (OR, 21.930; 95% CI, 1.960 to 245.319; P=0.012) were significantly associated with washout occurring within 60 seconds.
Conclusion
Characteristic Sonazoid-CEUS features are useful for diagnosing HCC in patients with NAFLD.
2.Characterization of non-alcoholic fatty liver disease–related hepatocellular carcinoma on contrast-enhanced ultrasound with Sonazoid
Yi DONG ; Juan CHENG ; Yun-Lin HUANG ; Yi-Jie QIU ; Jia-Ying CAO ; Xiu-Yun LU ; Wen-Ping WANG ; Kathleen MÖLLER ; Christoph F. DIETRICH
Ultrasonography 2025;44(3):232-242
Purpose:
This study aimed to evaluate the contrast-enhanced ultrasound with Sonazoid (Sonazoid-CEUS) features of hepatocellular carcinoma (HCC) in patients with non-alcoholic fatty liver disease (NAFLD).
Methods:
In this retrospective study, patients who underwent surgical resection and were histopathologically diagnosed with NAFLD or cirrhosis-related HCC were included. All patients received Sonazoid-CEUS examinations within 1 week prior to hepatic surgery. The enhancement patterns of HCC lesions were evaluated and compared between the two groups according to the current World Federation for Ultrasound in Medicine and Biology guidelines. Multivariate logistic regression analysis was used to assess the correlations between Sonazoid-CEUS enhancement patterns and clinicopathologic characteristics.
Results:
From March 2022 to April 2023, a total of 151 patients with HCC were included, comprising 72 with NAFLD-related HCC and 79 with hepatitis B virus (HBV) cirrhosis–related HCC. On Sonazoid-CEUS, more than half of the NAFLD-related HCCs exhibited relatively early and mild washout within 60 seconds (54.2%, 39/72), whereas most HBV cirrhosis–related HCCs displayed washout between 60 and 120 seconds (46.8%, 37/79) or after 120 seconds (39.2%, 31/79) (P<0.001). In the patients with NAFLD-related HCC, multivariate analysis revealed that international normalized ratio (odds ratio [OR], 0.002; 95% confidence interval [CI], 0.000 to 0.899; P=0.046) and poor tumor differentiation (OR, 21.930; 95% CI, 1.960 to 245.319; P=0.012) were significantly associated with washout occurring within 60 seconds.
Conclusion
Characteristic Sonazoid-CEUS features are useful for diagnosing HCC in patients with NAFLD.
3.Characterization of non-alcoholic fatty liver disease–related hepatocellular carcinoma on contrast-enhanced ultrasound with Sonazoid
Yi DONG ; Juan CHENG ; Yun-Lin HUANG ; Yi-Jie QIU ; Jia-Ying CAO ; Xiu-Yun LU ; Wen-Ping WANG ; Kathleen MÖLLER ; Christoph F. DIETRICH
Ultrasonography 2025;44(3):232-242
Purpose:
This study aimed to evaluate the contrast-enhanced ultrasound with Sonazoid (Sonazoid-CEUS) features of hepatocellular carcinoma (HCC) in patients with non-alcoholic fatty liver disease (NAFLD).
Methods:
In this retrospective study, patients who underwent surgical resection and were histopathologically diagnosed with NAFLD or cirrhosis-related HCC were included. All patients received Sonazoid-CEUS examinations within 1 week prior to hepatic surgery. The enhancement patterns of HCC lesions were evaluated and compared between the two groups according to the current World Federation for Ultrasound in Medicine and Biology guidelines. Multivariate logistic regression analysis was used to assess the correlations between Sonazoid-CEUS enhancement patterns and clinicopathologic characteristics.
Results:
From March 2022 to April 2023, a total of 151 patients with HCC were included, comprising 72 with NAFLD-related HCC and 79 with hepatitis B virus (HBV) cirrhosis–related HCC. On Sonazoid-CEUS, more than half of the NAFLD-related HCCs exhibited relatively early and mild washout within 60 seconds (54.2%, 39/72), whereas most HBV cirrhosis–related HCCs displayed washout between 60 and 120 seconds (46.8%, 37/79) or after 120 seconds (39.2%, 31/79) (P<0.001). In the patients with NAFLD-related HCC, multivariate analysis revealed that international normalized ratio (odds ratio [OR], 0.002; 95% confidence interval [CI], 0.000 to 0.899; P=0.046) and poor tumor differentiation (OR, 21.930; 95% CI, 1.960 to 245.319; P=0.012) were significantly associated with washout occurring within 60 seconds.
Conclusion
Characteristic Sonazoid-CEUS features are useful for diagnosing HCC in patients with NAFLD.
4.Characterization of non-alcoholic fatty liver disease–related hepatocellular carcinoma on contrast-enhanced ultrasound with Sonazoid
Yi DONG ; Juan CHENG ; Yun-Lin HUANG ; Yi-Jie QIU ; Jia-Ying CAO ; Xiu-Yun LU ; Wen-Ping WANG ; Kathleen MÖLLER ; Christoph F. DIETRICH
Ultrasonography 2025;44(3):232-242
Purpose:
This study aimed to evaluate the contrast-enhanced ultrasound with Sonazoid (Sonazoid-CEUS) features of hepatocellular carcinoma (HCC) in patients with non-alcoholic fatty liver disease (NAFLD).
Methods:
In this retrospective study, patients who underwent surgical resection and were histopathologically diagnosed with NAFLD or cirrhosis-related HCC were included. All patients received Sonazoid-CEUS examinations within 1 week prior to hepatic surgery. The enhancement patterns of HCC lesions were evaluated and compared between the two groups according to the current World Federation for Ultrasound in Medicine and Biology guidelines. Multivariate logistic regression analysis was used to assess the correlations between Sonazoid-CEUS enhancement patterns and clinicopathologic characteristics.
Results:
From March 2022 to April 2023, a total of 151 patients with HCC were included, comprising 72 with NAFLD-related HCC and 79 with hepatitis B virus (HBV) cirrhosis–related HCC. On Sonazoid-CEUS, more than half of the NAFLD-related HCCs exhibited relatively early and mild washout within 60 seconds (54.2%, 39/72), whereas most HBV cirrhosis–related HCCs displayed washout between 60 and 120 seconds (46.8%, 37/79) or after 120 seconds (39.2%, 31/79) (P<0.001). In the patients with NAFLD-related HCC, multivariate analysis revealed that international normalized ratio (odds ratio [OR], 0.002; 95% confidence interval [CI], 0.000 to 0.899; P=0.046) and poor tumor differentiation (OR, 21.930; 95% CI, 1.960 to 245.319; P=0.012) were significantly associated with washout occurring within 60 seconds.
Conclusion
Characteristic Sonazoid-CEUS features are useful for diagnosing HCC in patients with NAFLD.
5.Characterization of non-alcoholic fatty liver disease–related hepatocellular carcinoma on contrast-enhanced ultrasound with Sonazoid
Yi DONG ; Juan CHENG ; Yun-Lin HUANG ; Yi-Jie QIU ; Jia-Ying CAO ; Xiu-Yun LU ; Wen-Ping WANG ; Kathleen MÖLLER ; Christoph F. DIETRICH
Ultrasonography 2025;44(3):232-242
Purpose:
This study aimed to evaluate the contrast-enhanced ultrasound with Sonazoid (Sonazoid-CEUS) features of hepatocellular carcinoma (HCC) in patients with non-alcoholic fatty liver disease (NAFLD).
Methods:
In this retrospective study, patients who underwent surgical resection and were histopathologically diagnosed with NAFLD or cirrhosis-related HCC were included. All patients received Sonazoid-CEUS examinations within 1 week prior to hepatic surgery. The enhancement patterns of HCC lesions were evaluated and compared between the two groups according to the current World Federation for Ultrasound in Medicine and Biology guidelines. Multivariate logistic regression analysis was used to assess the correlations between Sonazoid-CEUS enhancement patterns and clinicopathologic characteristics.
Results:
From March 2022 to April 2023, a total of 151 patients with HCC were included, comprising 72 with NAFLD-related HCC and 79 with hepatitis B virus (HBV) cirrhosis–related HCC. On Sonazoid-CEUS, more than half of the NAFLD-related HCCs exhibited relatively early and mild washout within 60 seconds (54.2%, 39/72), whereas most HBV cirrhosis–related HCCs displayed washout between 60 and 120 seconds (46.8%, 37/79) or after 120 seconds (39.2%, 31/79) (P<0.001). In the patients with NAFLD-related HCC, multivariate analysis revealed that international normalized ratio (odds ratio [OR], 0.002; 95% confidence interval [CI], 0.000 to 0.899; P=0.046) and poor tumor differentiation (OR, 21.930; 95% CI, 1.960 to 245.319; P=0.012) were significantly associated with washout occurring within 60 seconds.
Conclusion
Characteristic Sonazoid-CEUS features are useful for diagnosing HCC in patients with NAFLD.
6.GBA1 Thr408Met mutation in a patient with Parkinson’s disease
Yi ZHAO ; Junwen LI ; Chunlian JU ; Weibin QIU ; Bo ZUO ; Zhigang YANG ; Yansheng LI
Chinese Journal of Clinical Medicine 2025;32(3):524-528
GBA1 gene mutation is an important genetic risk factor for Parkinson’s disease (PD). This paper reports a case of a 43-year-old male PD patient carrying a rare heterozygous Thr408Met mutation in the GBA1 gene identified through whole-exome sequencing, leading to a diagnosis of GBA1-associated PD. The patient’s motor symptoms were primarily characterized by bradykinesia and rigidity, without significant cognitive decline. Treatment with low-dose levodopa combined with a dopamine agonist resulted in significant symptomatic improvement.
7.Roles of A- and C-weighted kurtosis adjustment for equivalent sound level in evaluating occupational hearing loss
Haiying LIU ; Linjie WU ; Yang LI ; Jinzhe LI ; Jiarui XIN ; Hua ZOU ; Wei QIU ; Tong SHEN ; Meibian ZHANG
Journal of Environmental and Occupational Medicine 2025;42(7):793-799
Background Temporal kurtosis (without frequency weighting, i.e., Z-weighted kurtosis) can evaluate noise-induced hearing loss (NIHL). However, few studies have considered the function of frequency weighting (A- or C-weighted) kurtosis on NIHL. Objective To study the significance of A- and C-weighted kurtosis adjustment for equivalent sound level (L'EX,8 h) in evaluating occupational hearing loss. Methods A cross-sectional survey was used to select 973 noise-exposed workers in seven industries as the subjects. The noise exposure of all workers was assessed by distributions of A-, C-, and Z-weighted kurtosis (e.g., KA, KC, and KZ) and respective adjusted equivalent sound level (e.g., L'EX,8 h-KA, L'EX,8 h-KC, and L'EX,8 h-KZ). The significance of A- and C-weighted kurtosis in evaluating NIHL was evaluated by correlations between three types of L'EX,8 h and NIHL, and improvement of noise-induced permanent threshold shift (NIPTS) underestimation predicted by the ISO prediction model (Acoustics—Estimation of noise-induced hearing loss, ISO 1999-2013). Results The median KA, KC, and KZ were 68.33, 28.22, and 19.82, respectively. The binary logistic regression showed that LEX, 8 h-KA, LEX, 8 h-KC, and L'EX, 8 h-KZ were risk factors for NIHL (OR>1, P<0.001). The receiver operating characteristic (ROC) curve showed that when the outcome variable was noise-induced hearing impairment (NIHI), the areas under the curves corresponding to L'EX,8 h-KA, L'EX,8 h-KC, and L'EX,8 h-KZ were 0.625, 0.628, and 0.625, respectively. When the outcome variable was high-frequency noise-induced hearing loss (HFNIHL), the areas under the curves corresponding to L'EX,8 h-KA, L'EX, 8 h-KC, and L'EX,8 h-KZ were 0.624, 0.623, and 0.622, respectively (P<0.05). The order of underestimation improvement values predicted by L'EX,8 h for NIPTS1234 was: L'EX,8 h-KA (4.68 dB HL)>L'EX,8 h-KC (4.38 dB HL)>L'EX,8 h-KZ (4.28 dB HL) (P<0.001). The order of underestimation improvement values predicted by L'EX,8 h-K for NIPTS346 was: L'EX,8 h-KA (7.20 dB HL)>L'EX,8 h-KC (6.83 dB HL)>L'EX,8 h-KZ (6.71 dB HL) (P<0.001). Conclusion The adjustment of A- and C-weighted kurtosis to equivalent sound level LEX,8 h can effectively improve the accuracy of the ISO 1999 prediction model in NIPTS prediction, and compared with the C-weighted, the A-weighted kurtosis can improve the result of the ISO 1999 prediction model in terms of underestimating NIPTS.
8.Application of bicuspid pulmonary valve sewn by 0.1 mm expanded polytetrafluoroethylene in right ventricle outflow tract reconstruction
Jianrui MA ; Tong TAN ; Miao TIAN ; Jiazichao TU ; Wen XIE ; Hailong QIU ; Shuai ZHANG ; Jian ZHUANG ; Jimei CHEN ; Jianzheng CEN ; Shusheng WEN ; Haiyun YUAN ; Xiaobing LIU
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(08):1127-1132
Objective To introduce a modified technique of right ventricular outflow tract (RVOT) reconstruction using a handmade bicuspid pulmonary valve crafted from expanded polytetrafluoroethylene (ePTFE) and to summarize the early single-center experience. Methods Patients with complex congenital heart diseases (CHD) who underwent RVOT reconstruction with a handmade ePTFE bicuspid pulmonary valve due to pulmonary regurgitation at Guangdong Provincial People’s Hospital from April 2021 to February 2022 were selected. Postoperative artificial valve function and right heart function indicators were evaluated. Results A total of 17 patients were included, comprising 10 males and 7 females, with a mean age of (18.18±12.14) years and a mean body weight of (40.94±19.45) kg. Sixteen patients underwent reconstruction with a handmade valved conduit, with conduit sizes ranging from 18 to 24 mm. No patients required mechanical circulatory support, and no in-hospital deaths occurred. During a mean follow-up period of 12.89 months, only one patient developed valve dysfunction, and no related complications or adverse events were observed. The degree of pulmonary regurgitation was significantly improved post-RVOT reconstruction and during follow-up compared to preoperative levels (P<0.001). Postoperative right atrial diameter, right ventricular diameter, and tricuspid regurgitation area were all significantly reduced compared to preoperative values (P<0.05). Conclusion The use of a 0.1 mm ePTFE handmade bicuspid pulmonary valve for RVOT reconstruction in complex CHD is a feasible, effective, and safe technique.
9.Antibacterial activity of the antifungal peptide Mt6 - 21DLeu derived from Musca domestica against Acinetobacter baumannii and the underlying mechanisms
Xuan HUA ; Tong QIU ; Xuyuan WANG ; Renxian TANG ; Delong KONG
Chinese Journal of Schistosomiasis Control 2025;37(5):482-493
Objective To investigate the antibacterial activity of the antifungal peptide Mt6-21DLeu derived from Musca domestica against Acinetobacter baumannii (AB) and unravel its underlying mechanisms, so as to provide insights into development of novel agents against AB. Methods The minimum inhibitory concentrations (MICs) of Mt6-21DLeu, M. domestica-derived antifungal peptide-1 (MAF-1A), and polymyxin B were determined against Staphylococcus aureus, Bacillus subtilis, Escherichia coli, Klebsiella pneumoniae, Pseudomonas aeruginosa and AB using the broth microdilution assay, and the antibacterial activity of Mt6-21DLeu and polymyxin B was dynamically assessed against AB over 24 hours with time-kill curves. The inhibitory effects of Mt6-21DLeu and polymyxin B on biofilm formation in AB at concentrations of 1/4 × MIC, 1/2 × MIC and MIC, and the eradication effects of Mt6-21DLeu and polymyxin B on mature biofilms in AB at concentrations of MIC, 2 × MIC, and 4 × MIC were evaluated using crystal violet staining. Structural changes in the cell membrane of AB were observed 3 hours post-exposure to Mt6-21DLeu at concentrations of MIC and 2 × MIC using scanning electron microscopy, and alterations in the cell membrane permeability of AB were analyzed 3 hours post-treatment with Mt6-21DLeu at concentrations of MIC and 2 × MIC by means of fluorescence microscopy and propidium iodide (PI) staining. Intracellular reactive oxygen species (ROS) levels in AB were measured 3 hours post-treatment with Mt6-21DLeu at concentrations of MIC, 2 × MIC, and 4 × MIC using flow cytometry. The survival of Caenorhabditis elegans exposed to Mt6-21DLeu at concentrations of MIC, 2 × MIC, and 4 × MIC was monitored for 7 consecutive days, and survival curves were plotted to evaluate the in vivo toxicity of Mt6-21DLeu. In addition, C. elegans infected with AB and treated with Mt6-21DLeu at a concentration of 4 × MIC served as the treatment group, and uninfected C. elegans served as the control group, while infected but untreated C. elegans served as the infection group. The in vivo antibacterial efficacy of Mt6-21DLeu at a concentration of 4 × MIC was evaluated by comparing the survival curves and bacterial load among the three groups. Results The MICs of MAF-1A were all >128 μg/mL against S. aureus, B. subtilis, E. coli, K. pneumoniae, P. aeruginosa, and AB. In contrast, the MICs of Mt6-21DLeu were >128, 32, 8, 8, 16, and 4 μg/mL against these strains, respectively, and the MIC of Mt6-21DLeu against AB was close to that of polymyxin B (2 μg/mL). Time-kill curve analysis showed that both Mt6-21DLeu at concentrations of MIC and 2 × MIC and polymyxin B at a concentration of MIC inhibited AB growth over the 24-hour study period. The biofilm biomass in AB was (52.38 ± 6.92)%, (40.88 ± 9.17)% and (14.77 ± 6.00)% post-exposure with Mt6-21DLeu at concentrations of 1/4 × MIC, 1/2 × MIC and MIC, (61.58 ± 7.35)%, (47.42 ± 5.51)% and (20.85 ± 10.48)% post-treatment with polymyxin B at concentrations of 1/4 × MIC, 1/2 × MIC and MIC, and (100.00 ± 15.92)% in the control group (only bacterial suspension), respectively (F = 68.38, P < 0.001), and pairwise comparisons indicated that Mt6-21DLeu and polymyxin B at all concentrations significantly inhibited biofilm formation as compared to the control group (all P values < 0.001). The mature biofilm biomass in AB was (73.44 ± 11.41)%, (72.56 ± 13.08)% and (49.65 ± 9.23)% post-exposure to Mt6-21DLeu at concentrations of MIC, 2 × MIC, and 4 × MIC, (84.38 ± 8.60)%, (72.31 ± 9.63)% and (58.85 ± 4.96)% post-treatment with polymyxin B at concentrations of MIC, 2 × MIC, and 4 × MIC, and (100.00 ± 6.36)% in the control group (F = 35.63, P < 0.001), and pairwise comparisons revealed that Mt6-21DLeu at all concentrations significantly eradicated biofilm biomass (all P values < 0.05); however, polymyxin B showed no clear-cut eradication effect at a concentration of MIC (P > 0.05). Scanning electron microscopy revealed pore formation and content leakage in the cell membrane of AB 3 hours post-treatment with Mt6-21DLeu at concentrations of MIC and 2 × MIC. Fluorescence microscopy showed that the proportions of PI-stained AB were (24.79 ± 11.51)% and (68.44 ± 15.80)% post-treatment with Mt6-21DLeu at concentrations of MIC and 2 × MIC, and (0.96 ± 0.94)% in the phosphate-buffered saline (PBS) treatment group (F = 105.90, P < 0.001), with the highest proportion of PI-stained AB seen post-treatment with Mt6-21DLeu at a concentration of 2 × MIC (P < 0.05). Flow cytometry revealed that the relative intracellular ROS levels in AB were (652.00 ± 141.90), (694.33 ± 14.19), and (974.33 ± 160.02) 3 hours post-treatment with Mt6-21DLeu at concentrations of MIC, 2 × MIC and 4 × MIC, and (403.67 ± 86.56) in the PBS treatment group, respectively (F = 12.27, P < 0.05), with the highest intracellular ROS level measured following treatment with Mt6-21DLeu at a concentration of 4 × MIC (P < 0.05). Survival curve analysis revealed that Mt6-21DLeu posed no impact on C. elegans survival at concentrations of MIC (χ2 = 0.02, P > 0.05), 2 × MIC (χ2 = 0.06, P > 0.05) or 4 × MIC (χ2 = 0.16, P > 0.05), and there was a significant difference in the survival period of C. elegans among the control group, the infection group, and the treatment group (χ2 = 82.66, P < 0.05), with a significantly longer survival period in the treatment group than in the infection group (χ2 = 45.00, P < 0.05). In addition, the log-transformed bacterial colony counts in C. elegans were (0.00 ± 0.00), (5.46 ± 0.03), and (3.91 ± 0.47) CFU/mL in the control group, the infection group, and the treatment group, respectively (F = 324.80, P < 0.001), and the log-transformed bacterial colony counts in C. elegans were significantly lower in the treatment group than in the infection group (P < 0.05). Conclusions Mt6-21DLeu exerts potent antibacterial effects through disrupting the cell membrane integrity of AB and promoting intracellular ROS accumulation in AB, and exhibits promising potential for treatment of AB infections both in vivo and in vitro, which may serve as a candidate drug molecule against multidrug-resistant AB infections.
10.Establishment and validation of bioactivity measurement method for recombinant human midkine
Ying ZHANG ; Ting HE ; Ming-feng QIU ; Sheng-bin PENG
Acta Pharmaceutica Sinica 2024;59(1):198-201
To establish and optimize a method for the detection of recombinant human midkine (rhMK) activity and verify its methodology, cell counting kit-8 (cck-8) method was used to measure the proliferation activity of rat knee chondrocytes. The specificity, accuracy, precision, linearity and robustness of the method were also verified in this study. The established method was proven to have good specificity because the buffer of rhMK and recombinant human interleukin-1 receptor antagonist have no obvious active effect; the recoveries of the samples with relative activities of 50%, 75%, 100%, 125%, 150% were in the range of 80.0% to 124.0% by statistical analysis, the relative standard deviations (RSD) of relative potency were all within 20%, the linear correlation coefficient,

Result Analysis
Print
Save
E-mail