1.Methods for enhancing image quality of soft tissue regions in synthetic CT based on cone-beam CT.
Ziwei FU ; Yechen ZHU ; Zijian ZHANG ; Xin GAO
Journal of Biomedical Engineering 2025;42(1):113-122
Synthetic CT (sCT) generated from CBCT has proven effective in artifact reduction and CT number correction, facilitating precise radiation dose calculation. However, the quality of different regions in sCT images is severely imbalanced, with soft tissue region exhibiting notably inferior quality compared to others. To address this imbalance, we proposed a Multi-Task Attention Network (MuTA-Net) based on VGG-16, specifically focusing the enhancement of image quality in soft tissue region of sCT. First, we introduced a multi-task learning strategy that divides the sCT generation task into three sub-tasks: global image generation, soft tissue region generation and bone region segmentation. This approach ensured the quality of overall sCT image while enhancing the network's focus on feature extraction and generation for soft tissues region. The result of bone region segmentation task guided the fusion of sub-tasks results. Then, we designed an attention module to further optimize feature extraction capabilities of the network. Finally, by employing a results fusion module, the results of three sub-tasks were integrated, generating a high-quality sCT image. Experimental results on head and neck CBCT demonstrated that the sCT images generated by the proposed MuTA-Net exhibited a 12.52% reduction in mean absolute error in soft tissue region, compared to the best performance among the three comparative methods, including ResNet, U-Net, and U-Net++. It can be seen that MuTA-Net is suitable for high-quality sCT image generation and has potential application value in the field of CBCT guided adaptive radiation therapy.
Cone-Beam Computed Tomography/methods*
;
Humans
;
Image Processing, Computer-Assisted/methods*
;
Artifacts
;
Algorithms
;
Bone and Bones/diagnostic imaging*
;
Neural Networks, Computer
2.Research on a portable electrical impedance tomography system for evaluating blood compatibility of biomaterials.
Piao PENG ; Huaihao CHEN ; Bo CHE ; Xuan LI ; Chunjian FAN ; Lei LIU ; Teng LUO ; Linhong DENG
Journal of Biomedical Engineering 2025;42(2):219-227
The evaluation of blood compatibility of biomaterials is crucial for ensuring the clinical safety of implantable medical devices. To address the limitations of traditional testing methods in real-time monitoring and electrical property analysis, this study developed a portable electrical impedance tomography (EIT) system. The system uses a 16-electrode design, operates within a frequency range of 1 to 500 kHz, achieves a signal to noise ratio (SNR) of 69.54 dB at 50 kHz, and has a data collection speed of 20 frames per second. Experimental results show that the EIT system developed in this study is highly consistent with a microplate reader ( R 2=0.97) in detecting the hemolytic behavior of industrial-grade titanium (TA3) and titanium alloy-titanium 6 aluminum 4 vanadium (TC4) in anticoagulated bovine blood. Additionally, with the support of a multimodal image fusion Gauss-Newton one-step iterative algorithm, the system can accurately locate and monitor in real-time the dynamic changes in blood permeation and coagulation caused by TC4 in vivo. In conclusion, the EIT system developed in this study provides a new and effective method for evaluating the blood compatibility of biomaterials.
Electric Impedance
;
Animals
;
Tomography/instrumentation*
;
Biocompatible Materials
;
Materials Testing/instrumentation*
;
Cattle
;
Titanium
;
Alloys
;
Prostheses and Implants
3.Study on the separation method of lung ventilation and lung perfusion signals in electrical impedance tomography based on rime algorithm optimized variational mode decomposition.
Guobin GAO ; Kun LI ; Junyao LI ; Mingxu ZHU ; Yu WANG ; Xiaoheng YAN ; Xuetao SHI
Journal of Biomedical Engineering 2025;42(2):228-236
Real-time acquisition of pulmonary ventilation and perfusion information through thoracic electrical impedance tomography (EIT) holds significant clinical value. This study proposes a novel method based on the rime (RIME) algorithm-optimized variational mode decomposition (VMD) to separate lung ventilation and perfusion signals directly from raw voltage data prior to EIT image reconstruction, enabling independent imaging of both parameters. To validate this approach, EIT data were collected from 16 healthy volunteers under normal breathing and inspiratory breath-holding conditions. The RIME algorithm was employed to optimize VMD parameters by minimizing envelope entropy as the fitness function. The optimized VMD was then applied to separate raw data across all measurement channels in EIT, with spectral analysis identifying relevant components to reconstruct ventilation and perfusion signals. Results demonstrated that the structural similarity index (SSIM) between perfusion images derived from normal breathing and breath-holding states averaged approximately 84% across all 16 subjects, significantly outperforming traditional frequency-domain filtering methods in perfusion imaging accuracy. This method offers a promising technical advancement for real-time monitoring of pulmonary ventilation and perfusion, holding significant value for advancing the clinical application of EIT in the diagnosis and treatment of respiratory diseases.
Humans
;
Electric Impedance
;
Algorithms
;
Tomography/methods*
;
Pulmonary Ventilation/physiology*
;
Lung/diagnostic imaging*
;
Image Processing, Computer-Assisted/methods*
;
Adult
4.Development and evaluation of a positioning system for radiotherapy patient based on structured light surface imaging.
Yungang WANG ; Gongsen ZHANG ; Xianrui YAN ; Guangjie YANG ; Wei WANG ; Jian ZHU ; Linlin WANG
Journal of Biomedical Engineering 2025;42(2):237-245
This paper aims to propose a noninvasive radiotherapy patient positioning system based on structured light surface imaging, and evaluate its clinical feasibility. First, structured light sensors were used to obtain the panoramic point clouds during radiotherapy positioning in real time. The fusion of different point clouds and coordinate transformation were realized based on optical calibration and pose estimation, and the body surface was segmented referring to the preset region of interest (ROI). Then, the global-local registration of cross-source point cloud was achieved based on algorithms such as random sample consensus (RANSAC) and iterative closest point (ICP), to calculate 6 degrees of freedom (DoF) positioning deviation and provide guidance for the correction of couch shifts. The evaluation of the system was carried out based on a rigid adult phantom and volunteers' body, which included positioning error, correlation analysis, and receiver operating characteristic (ROC) analysis. Using Cone Beam CT (CBCT) as the gold standard, the maximum translation and rotation errors of this system were (1.5 ± 0.9) mm along Vrt direction (chest) and (0.7 ± 0.3) ° along Pitch direction (head and neck). The Pearson correlation coefficient between results of system outputs and CBCT verification distributed in an interval of [0.80, 0.84]. Results of ROC analysis showed that the translational and rotational AUC values were 0.82 and 0.85, respectively. In the 4D freedom accuracy test on the human body of volunteers, the maximum translation and rotation errors were (2.6 ± 1.1) mm (Vrt direction, chest and abdomen) and (0.8 ± 0.4)° (Rtn direction, chest and abdomen) respectively. In summary, the positioning system based on structured light body surface imaging proposed in this article can ensure positioning accuracy without surface markers and additional doses, and is feasible for clinical application.
Humans
;
Patient Positioning/methods*
;
Phantoms, Imaging
;
Cone-Beam Computed Tomography
;
Algorithms
;
Radiotherapy, Image-Guided/methods*
;
Radiotherapy Planning, Computer-Assisted/methods*
5.Stroke-p2pHD: Cross-modality generation model of cerebral infarction from CT to DWI images.
Qing WANG ; Xinyao ZHAO ; Xinyue LIU ; Zhimeng ZOU ; Haiwang NAN ; Qiang ZHENG
Journal of Biomedical Engineering 2025;42(2):255-262
Among numerous medical imaging modalities, diffusion weighted imaging (DWI) is extremely sensitive to acute ischemic stroke lesions, especially small infarcts. However, magnetic resonance imaging is time-consuming and expensive, and it is also prone to interference from metal implants. Therefore, the aim of this study is to design a medical image synthesis method based on generative adversarial network, Stroke-p2pHD, for synthesizing DWI images from computed tomography (CT). Stroke-p2pHD consisted of a generator that effectively fused local image features and global context information (Global_to_Local) and a multi-scale discriminator (M 2Dis). Specifically, in the Global_to_Local generator, a fully convolutional Transformer (FCT) and a local attention module (LAM) were integrated to achieve the synthesis of detailed information such as textures and lesions in DWI images. In the M 2Dis discriminator, a multi-scale convolutional network was adopted to perform the discrimination function of the input images. Meanwhile, an optimization balance with the Global_to_Local generator was ensured and the consistency of features in each layer of the M 2Dis discriminator was constrained. In this study, the public Acute Ischemic Stroke Dataset (AISD) and the acute cerebral infarction dataset from Yantaishan Hospital were used to verify the performance of the Stroke-p2pHD model in synthesizing DWI based on CT. Compared with other methods, the Stroke-p2pHD model showed excellent quantitative results (mean-square error = 0.008, peak signal-to-noise ratio = 23.766, structural similarity = 0.743). At the same time, relevant experimental analyses such as computational efficiency verify that the Stroke-p2pHD model has great potential for clinical applications.
Humans
;
Tomography, X-Ray Computed/methods*
;
Diffusion Magnetic Resonance Imaging/methods*
;
Cerebral Infarction/diagnostic imaging*
;
Stroke/diagnostic imaging*
;
Neural Networks, Computer
;
Image Processing, Computer-Assisted/methods*
;
Algorithms
6.A method for determining spatial resolution of phantom based on automatic contour delineation.
Ying LIU ; Minghao SUN ; Haowei ZHANG ; Haikuan LIU
Journal of Biomedical Engineering 2025;42(2):263-271
In this study, we propose an automatic contour outlining method to measure the spatial resolution of homemade automatic tube current modulation (ATCM) phantom by outlining the edge contour of the phantom image, selecting the region of interest (ROI), and measuring the spatial resolution characteristics of computer tomography (CT) phantom image. Specifically, the method obtains a binarized image of the phantom outlined by an automated fast region convolutional neural network (AFRCNN) model, measures the edge spread function (ESF) of the CT phantom with different tube currents and layer thicknesses, and differentiates the ESF to obtain the line spread function (LSF). Finally, the values passing through the zeros are normalized by the Fourier transform to obtain the CT spatial resolution index (RI) for the automatic measurement of the modulation transfer function (MTF). In this study, this algorithm is compared with the algorithm that uses polymethylmethacrylate (PMMA) to measure the MTF of the phantom edges to verify the feasibility of this method, and the results show that the AFRCNN model not only improves the efficiency and accuracy of the phantom contour outlining, but also is able to obtain a more accurate spatial resolution value through automated segmentation. In summary, the algorithm proposed in this study is accurate in spatial resolution measurement of phantom images and has the potential to be widely used in real clinical CT images.
Phantoms, Imaging
;
Tomography, X-Ray Computed/instrumentation*
;
Algorithms
;
Neural Networks, Computer
;
Image Processing, Computer-Assisted/methods*
;
Humans
;
Polymethyl Methacrylate
7.A study on the predictive model of porous hyperelastic properties of human alveolar bone based on computed tomography imaging.
Bin WU ; Mingna LI ; Fan YANG ; Le YUAN ; Yi LU ; Di JIANG ; Yang YI ; Bin YAN
Journal of Biomedical Engineering 2025;42(2):359-365
Alveolar bone reconstruction simulation is an effective means for quantifying orthodontics, but currently, it is not possible to directly obtain human alveolar bone material models for simulation. This study introduces a prediction method for the equivalent shear modulus of three-dimensional random porous materials, integrating the first-order Ogden hyperelastic model to construct a computed tomography (CT) based porous hyperelastic Ogden model (CT-PHO) for human alveolar bone. Model parameters are derived by combining results from micro-CT, nanoindentation experiments, and uniaxial compression tests. Compared to previous predictive models, the CT-PHO model shows a lower root mean square error (RMSE) under all bone density conditions. Simulation results using the CT-PHO model parameters in uniaxial compression experiments demonstrate more accurate prediction of the mechanical behavior of alveolar bone under compression. Further prediction and validation with different individual human alveolar bone samples yield accurate results, confirming the generality of the CT-PHO model. The study suggests that the CT-PHO model proposed in this paper can estimate the material properties of human alveolar bone and may eventually be used for bone reconstruction simulations to guide clinical treatment.
Humans
;
Tomography, X-Ray Computed/methods*
;
Porosity
;
Alveolar Process/physiology*
;
Bone Density
;
Computer Simulation
;
Elasticity
;
X-Ray Microtomography
;
Stress, Mechanical
;
Finite Element Analysis
;
Models, Biological
8.Application of electrical impedance tomography in diagnosis and monitoring of pulmonary diseases.
Xiaomin HU ; Shuaifu ZHANG ; Panfeng CHEN ; Feng DONG ; Haojun FAN ; Qi LYU ; Yanbin XU
Journal of Biomedical Engineering 2025;42(2):389-395
Electrical impedance tomography (EIT) is a new non-invasive functional imaging technology, which has the advantages of non-invasion, non-radiation, low cost, fast response, portability and visualization. In recent years, more and more studies have shown that EIT has great potential in the detection of lung diseases and has been applied to early diagnosis and treatment of some diseases. This paper introduced the basic principle of EIT, discussed the research and clinical application of EIT in the detection of acute respiratory distress syndrome, chronic obstructive pulmonary disease, pneumothorax and pulmonary embolism, and focused on the summary and introduction of indicators and functional images of EIT related to the detection of lung diseases. This review will help medical workers understand and use EIT, and promote the further development of EIT in lung diseases as well as other fields.
Humans
;
Electric Impedance
;
Tomography/methods*
;
Lung Diseases/diagnosis*
;
Pulmonary Disease, Chronic Obstructive/diagnosis*
;
Pulmonary Embolism/diagnosis*
;
Respiratory Distress Syndrome/diagnosis*
9.Cross modal translation of magnetic resonance imaging and computed tomography images based on diffusion generative adversarial networks.
Hong SHAO ; Yixuan JING ; Wencheng CUI
Journal of Biomedical Engineering 2025;42(3):575-584
To address the issues of difficulty in preserving anatomical structures, low realism of generated images, and loss of high-frequency image information in medical image cross-modal translation, this paper proposes a medical image cross-modal translation method based on diffusion generative adversarial networks. First, an unsupervised translation module is used to convert magnetic resonance imaging (MRI) into pseudo-computed tomography (CT) images. Subsequently, a nonlinear frequency decomposition module is used to extract high-frequency CT images. Finally, the pseudo-CT image is input into the forward process, while the high-frequency CT image as a conditional input is used to guide the reverse process to generate the final CT image. The proposed model is evaluated on the SynthRAD2023 dataset, which is used for CT image generation for radiotherapy planning. The generated brain CT images achieve a Fréchet Inception Distance (FID) score of 33.159 7, a structure similarity index measure (SSIM) of 89.84%, a peak signal-to-noise ratio (PSNR) of 35.596 5 dB, and a mean squared error (MSE) of 17.873 9. The generated pelvic CT images yield an FID score of 33.951 6, a structural similarity index of 91.30%, a PSNR of 34.870 7 dB, and an MSE of 17.465 8. Experimental results show that the proposed model generates highly realistic CT images while preserving anatomical accuracy as much as possible. The transformed CT images can be effectively used in radiotherapy planning, further enhancing diagnostic efficiency.
Humans
;
Tomography, X-Ray Computed/methods*
;
Magnetic Resonance Imaging/methods*
;
Image Processing, Computer-Assisted/methods*
;
Neural Networks, Computer
;
Brain/diagnostic imaging*
;
Algorithms
;
Radiotherapy Planning, Computer-Assisted
;
Generative Adversarial Networks
10.Biomechanical study of lumbar vertebra during gait cycle in adolescent idiopathic scoliosis.
Yunxin WANG ; Ping XU ; Yingsong WANG ; Yingliang LIU ; Shisen XU ; Zhi ZHAO ; Hongfei LI ; Xiaoming CHEN
Journal of Biomedical Engineering 2025;42(3):601-609
In order to investigate the mechanical response of lumbar vertebrae during gait cycle in adolescents with idiopathic scoliosis (AIS), the present study was based on computed tomography (CT) data of AIS patients to construct model of the left support phase (ML) and model of the right support phase (MR), respectively. Firstly, material properties, boundary conditions and load loading were set to simulate the lumbar vertebra-pelvis model. Then, the difference of stress and displacement in the lumbar spine between ML and MR was compared based on the stress and displacement cloud map. The results showed that in ML, the lumbar stress was mostly distributed on the convex side, while in MR, it was mostly distributed on the concave side. The stress of the two types of stress mainly gathered near the vertebral arch plate, and the stress of the vertebral arch plate was transmitted to the vertebral body through the pedicle with the progress of gait. The average stress of the intervertebral tissue in MR was greater than that in ML, and the difference of stress on the convex and convex side was greater. The displacement of lumbar vertebrae in ML decreased gradually from L1 to L5. The opposite is true in MR. In conclusion, this study can accurately quantify the stress on the lumbar spine during gait, and may provide guidance for brace design and clinical decision making.
Humans
;
Lumbar Vertebrae/diagnostic imaging*
;
Scoliosis/diagnostic imaging*
;
Adolescent
;
Gait/physiology*
;
Biomechanical Phenomena
;
Tomography, X-Ray Computed
;
Stress, Mechanical
;
Female
;
Male

Result Analysis
Print
Save
E-mail