1.Electrical stimulation based on triboelectric nanogenerator promotes osteogenesis of MC3T3-E1 cells on titanium surfaces.
Bo PANG ; Shu YANG ; Hongyang HAN ; Xingwei ZHANG ; Tao SONG
Journal of Biomedical Engineering 2025;42(2):366-373
This paper aims to explore the effect of electrical stimulation of triboelectric nanogenerators (TENGs) on the osteogenic and other biological behaviors of mouse embryonic osteoblast precursor cells (MC3T3-E1 cells) on titanium surfaces. First, an origami-type TENG was fabricated, and its electrical output performance was tested. The optimal current of the generator and the feasibility of the experiment were verified by the CCK-8 assay and scratch assay. At the optimal current, the osteogenic conditions of the cells in each group were determined by quantitative analysis of the total protein content, alkaline phosphatase (ALP) activity, and alizarin red staining (ARS) on the titanium surface. Finally, the adhesion and spreading of cells on the titanium surface after electrical stimulation were observed. The results showed that the TENG had good electrical output performance, with an open-circuit voltage of 65 V and a short-circuit current of 42 μA. Compared with the rest of the current, a current strength of 30 μA significantly improved cell proliferation and migration, osteogenesis, and adhesion and spreading capabilities. The above results confirm the safety and operability of TENG in biomedical applications, laying the foundation for future TENG applications in reducing the time of bone integration around titanium implants after surgery.
Titanium/chemistry*
;
Osteogenesis
;
Animals
;
Mice
;
Osteoblasts/cytology*
;
Electric Stimulation/instrumentation*
;
Cell Adhesion
;
Cell Proliferation
;
Surface Properties
;
Cell Differentiation
;
Nanotechnology
2.Research progress on enhancing osseointegration properties of polyetheretherketone implants through various modification methods.
Shilai LIU ; Xiaoke FENG ; Chunxia CHEN
Journal of Biomedical Engineering 2025;42(2):417-422
This review article summarizes the current modification methods employed to enhance the osseointegration properties of polyetheretherketone (PEEK), a novel biomaterial. Our analysis highlights that strategies such as surface treatment, surface modification, and the incorporation of bioactive composites can markedly improve the bioactivity of PEEK surfaces, thus facilitating their effective integration with bone tissue. However, to ensure widespread application of PEEK in the medical field, particularly in oral implantology, additional experiments and long-term clinical evaluations are required. Looking ahead, future research should concentrate on developing innovative modification techniques and assessment methodologies to further optimize the performance of PEEK implant materials. The ultimate goal is to provide the clinical setting with even more reliable solutions.
Benzophenones
;
Ketones/chemistry*
;
Polyethylene Glycols/chemistry*
;
Osseointegration
;
Humans
;
Polymers
;
Biocompatible Materials/chemistry*
;
Surface Properties
;
Prostheses and Implants
;
Dental Implants
3.Influence of two methods of smear layer removal on the surface properties of dentin.
Lingli ZHU ; Lin TANG ; Bowen LI ; Mei WANG ; Yuhua LIU
Journal of Peking University(Health Sciences) 2025;57(2):340-346
OBJECTIVE:
To explore the effects of two methods of smear layer removal on the surface properties of dentin.
METHODS:
Sixty extracted sound third molars were collected in this study, and were prepared as uniform dentin specimens with smear layer. All specimens were randomly divided into three groups: Control group, ultrasonic treatment (UT) group and etched treatment (ET) group. Scanning electron microscope (SEM) were used to observe the surface micromorphology of all three groups. Then, the surface elements, mineral phases and functional groups were analyzed by energy dispersive X-ray spectroscopy (EDX), X-ray diffraction (XRD) and flourier transformed infrared spectrometer (FTIR) respectively. The mechanical properties, hydrophilicity and biocompatibility were also further evaluated.
RESULTS:
It was revealed that dentin tubules of UT and ET groups were exposed, but lots of dentin debris piled up on the surface of the control one which covered up dentin tubules on the surface. The EDX results should that the weaker peak value of calcium and phosphorus in ET group than control and UT groups. Characteristic peaks of hydroxyapatite could be seen by XRD in all of the three groups, but lower distinctive peaks of amide Ⅰ, Ⅱ and Ⅲ bands of collagen of the dentin surface in control group than in ET and UT groups. The microhardness results showed that ET group was lower than control and UT groups, the difference was significant (P < 0.05). Better hydrophilicity of ET group was investigated (P < 0.05) than control group and UT group. Cells could be observed to adhere normally to dentin surface of each group which meant that all of the three groups had good biocompatibility.
CONCLUSION
Both UT and ET could effectively remove the smear layer on the surface of dentin and had no adverse effect of the dentin micromorphology and biocompatibility. The ultrasonic removal of the smear layer did not influence the mineral structure, hydrophilicity and mechanical properties of dentin surface. Although ET can effectively improve the hydrophilicity of dentin but decreased mechanical properties and the content of calcium and phosphorus.
Dentin/ultrastructure*
;
Humans
;
Surface Properties
;
Smear Layer
;
Molar, Third
;
Microscopy, Electron, Scanning
;
Dental Etching/methods*
4.Advances in Surface Modification Techniques of Ureteral Stents.
Guanjun MA ; Hua XIE ; Chao ZHOU ; Guangtai ZHOU ; Haijun ZHANG
Chinese Journal of Medical Instrumentation 2025;49(4):406-414
The article introduces the formation process of bacterial infection and encrustation on the surface of ureteral stents, elaborates in detail on six surface modification methods for ureteral stents, namely impregnation, spraying, vapor deposition, chemical grafting, self-assembly, and electrospinning, then analyzes the advantages and limitations of each technique during application. Meanwhile, it introduces three commonly used materials for ureteral stents, namely polymers, metals, and biodegradable materials, and further explains the commonly used surface modification methods corresponding to different materials. Looking ahead, with the continuous strengthening of the multi-technology integration trend and the continuous advancement of new material research and development, it is expected that a more ideal ureteral stent can be developed.
Stents
;
Ureter
;
Surface Properties
;
Humans
5.Effects of cell area on single odontoblast polarization and differentiation via microarray technology.
Huen LI ; Nianzuo YU ; Xiheng LI ; Xiaoduo TANG ; Yalu SUN ; Chao SI ; Junhu ZHANG ; Bei CHANG
West China Journal of Stomatology 2025;43(2):183-189
OBJECTIVES:
This study aimed to explore the impact of cell spreading area on odontoblast polarization and differentiation using micropatterned surfaces ge-nerated by photolithography.
METHODS:
Micropatterned surfaces with differential adhesive properties were prepared using polyethylene glycol diacrylate (PEGDA)-ba-sed photolithography. Human dental pulp stem cells (hD-PSCs) were isolated into single cells and cultured on micropatterned surfaces with areas of 1 800, 2 700, and 3 600 μm2. Immunofluorescence staining was used to observe cell morphology and analyze the relocating of the golgi apparatus and nucleus. Alkaline phosphatase staining was preformed to examine odontogenic differentiation.
RESULTS:
The hDPSCs were successfully isolated and cultured on micropatterned surfaces mimicking the morphology of polarized odontoblasts. Phalloidin staining confirmed that the isolated hDPSCs successfully recapitulated the morphology of predesigned micropatterns. Immunofluorescence staining showed that the polarization and differentiation levels of the hDPSCs with a 3600 μm2 area were significantly higher than those with 1 800 and 2 700 μm2 areas (P<0.05).
CONCLUSIONS
The polarization and differentiation of single hDPSCs increased with the cell areas on micropatterned surfaces.
Cell Differentiation
;
Humans
;
Dental Pulp/cytology*
;
Odontoblasts/cytology*
;
Stem Cells/cytology*
;
Cells, Cultured
;
Cell Polarity
;
Surface Properties
6.In vitro osteogenic performance study of graphene oxide-coated titanium surfaces modified with dopamine or silane.
Qinglin WU ; Yingzhen LAI ; Yanling HUANG ; Zeyu XIE ; Yanyin LIN
West China Journal of Stomatology 2025;43(3):336-345
OBJECTIVES:
This study aimed to compare the osteogenic performance differences of titanium surface coatings modified by dopamine or silanized graphene oxide, and to provide a more suitable modification scheme for titanium surface graphene oxide coatings.
METHODS:
Titanium was subjected to alkali-heat treatment and then modified with dopamine and silanization, respectively, followed by coating with graphene oxide. Control and experimental groups were designed as follows: pure titanium (Ti) group; titanium after alkali-heat treatment (Ti-NaOH) group; titanium after alkali-heat treatment and silanization modification (Ti-APTES) group; titanium after alkali-heat treatment and dopamine modification (Ti-DOPA) group; titanium with silanization-modified surface decorated with graphene oxide (Ti-APTES/GO) group; titanium with dopamine-modified surface decorated with graphene oxide (Ti-DOPA/GO) group. The physical and chemical properties of the material surfaces were analyzed using scanning electron microscopy (SEM), contact angle goniometer, X-ray photoelectron spectroscopy (XPS), and Raman spectrometer. The proliferation and adhesion morphology of mouse embryonic osteoblast precursor cells MC3T3-E1 on the material surfaces were observed by cell viability detection and immunofluorescence staining followed by laser confocal microscopy. The effects on the osteogenic differentiation of MC3T3-E1 cells were studied by alkaline phosphatase (ALP) staining, alizarin red staining and quantification, and real-time quantitative polymerase chain reaction.
RESULTS:
After modification with graphene oxide coating, a thin-film-like structure was observed on the surface under SEM. The hydrophilicity of all experimental groups was improved, among which the Ti-DOPA/GO group had the best hydrophilicity. XPS and Raman spectroscopy analysis showed that the modified materials exhibited typical D and G peaks, and XPS revealed the presence of a large number of oxygen-containing functional groups on the surface. CCK8 assay showed that all groups of materials had no cytotoxicity, and the proliferation level of the Ti-APTES/GO group was higher than that of the Ti-DOPA/GO group. Under the laser confocal microscope, the cells in the Ti-DOPA/GO and Ti-APTES/GO groups spread more fully. The Ti-DOPA/GO and Ti-APTES/GO groups had the deepest ALP staining, and the Ti-APTES/GO group had the most alizarin red-stained mineralized nodules and the highest quantitative result of alizarin red staining. In the Ti-DOPA/GO and Ti-APTES/GO groups, the expression of the early osteogenic-related gene RUNX2 reached a relatively high level, while in the expression of the late osteogenic-related genes OPN and OCN, the Ti-APTES/GO group performed better than the Ti-DOPA/GO group.
CONCLUSIONS
Ti-APTES/GO significantly outperformed Ti-DOPA/GO in promoting the adhesion, proliferation, and in vitro osteogenic differentiation of MC3T3-E1 cells.
Titanium/chemistry*
;
Graphite/chemistry*
;
Dopamine/chemistry*
;
Animals
;
Mice
;
Osteogenesis
;
Osteoblasts/cytology*
;
Surface Properties
;
Cell Proliferation
;
Silanes/chemistry*
;
Cell Adhesion
;
Coated Materials, Biocompatible/chemistry*
;
Cell Differentiation
;
Alkaline Phosphatase/metabolism*
;
Microscopy, Electron, Scanning
7.Progress in antibacterial/osteogenesis dual-functional surface modification strategy of titanium-based implants.
Peng LIU ; Bo FAN ; Lei ZOU ; Lijun LÜ ; Qiuming GAO
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(10):1300-1313
OBJECTIVE:
To review antibacterial/osteogenesis dual-functional surface modification strategy of titanium-based implants, so as to provide reference for subsequent research.
METHODS:
The related research literature on antibacterial/osteogenesis dual-functional surface modification strategy of titanium-based implants in recent years was reviewed, and the research progress was summarized based on different kinds of antibacterial substances and osteogenic active substances.
RESULTS:
At present, the antibacterial/osteogenesis dual-functional surface modification strategy of titanium-based implants includes: ① Combined coating strategy of antibiotics and osteogenic active substances. It is characterized in that antibiotics can be directly released around titanium-based implants, which can improve the bioavailability of drugs and reduce systemic toxicity. ② Combined coating strategy of antimicrobial peptides and osteogenic active substances. The antibacterial peptides have a wide antibacterial spectrum, and bacteria are not easy to produce drug resistance to them. ③ Combined coating strategy of inorganic antibacterial agent and osteogenic active substances. Metal ions or metal nanoparticles antibacterial agents have broad-spectrum antibacterial properties and various antibacterial mechanisms, but their high-dose application usually has cytotoxicity, so they are often combined with substances that osteogenic activity to reduce or eliminate cytotoxicity. In addition, inorganic coatings such as silicon nitride, calcium silicate, and graphene also have good antibacterial and osteogenic properties. ④ Combined coating strategy of metal organic frameworks/osteogenic active substances. The high specific surface area and porosity of metal organic frameworks can effectively package and transport antibacterial substances and bioactive molecules. ⑤ Combined coating strategy of organic substances/osteogenic active substancecs. Quaternary ammonium compounds, polyethylene glycol, N-haloamine, and other organic compounds have good antibacterial properties, and are often combined with hydroxyapatite and other substances that osteogenic activity.
CONCLUSION
The factors that affect the antibacterial and osteogenesis properties of titanium-based implants mainly include the structure and types of antibacterial substances, the structure and types of osteogenesis substances, and the coating process. At present, there is a lack of clinical verification of various strategies for antibacterial/osteogenesis dual-functional surface modification of titanium-based implants. The optimal combination, ratio, dose-effect mechanism, and corresponding coating preparation process of antibacterial substances and bone-active substances are needed to be constantly studied and improved.
Anti-Bacterial Agents/pharmacology*
;
Coated Materials, Biocompatible/chemistry*
;
Metal-Organic Frameworks/pharmacology*
;
Osteogenesis
;
Surface Properties
;
Titanium/pharmacology*
;
Prostheses and Implants
8.Effect of graphene-oxide-modified osteon-like concentric microgrooved surface on the osteoclastic differentiation of macrophages.
Hong WANG ; Qinglin WU ; Yingzhen LAI ; Yihuang CAI
West China Journal of Stomatology 2023;41(2):165-174
OBJECTIVES:
This study aimed to investigate the effect of new biomimetic micro/nano surfaces on the osteoclastic differentiation of RAW264.7 macrophages by simulating natural osteons for the design of concentric circular structures and modifying graphene oxide (GO).
METHODS:
The groups were divided into smooth titanium surface group (SS), concentric microgrooved titanium surface group (CMS), and microgroove modified with GO group (GO-CMS). The physicochemical properties of the material surfaces were studied using scanning electron microscopy (SEM), contact-angle measurement, atomic force microscopy, X-ray photoelectron spectroscopy analysis, and Raman spectroscopy. The effect of the modified material surface on the cell biological behavior of RAW264.7 was investigated by cell-activity assay, SEM, and laser confocal microscopy. The effect on the osteoclastic differentiation of macrophages was investiga-ted by tartrate-resistant acid phosphatase (TRAP) immunofluorescence staining and quantitative real-time polymerase chain reaction (qRT-PCR) experiments.
RESULTS:
Macrophages were arranged in concentric circles along the microgrooves, and after modification with GO, the oxygen-containing groups on the surface of the material increased and hydrophilicity increased. Osteoclasts in the GO-CMS group were small in size and number and had the lowest TRAP expression. Although it promoted the proliferation of macrophages in the GO-CMS group, the expression of osteoclastic differentiation-related genes was lower than that in the SS group, and the difference was statistically significant (P<0.05).
CONCLUSIONS
Concentric circular microgrooves restricted the fusion of osteoclasts and the formation of sealing zones. Osteomimetic concentric microgrooves modified with GO inhibited the osteoclastic differentiation of RAW 264.7 macrophages.
Graphite/pharmacology*
;
Titanium/pharmacology*
;
Haversian System
;
Macrophages
;
Cell Differentiation
;
Oxides/pharmacology*
;
Surface Properties
9.Effects of thermal cycling on bonding properties of novel low-shrinkage resin adhesive.
Zonghua WANG ; Xiaoran ZHANG ; Shuo YAO ; Jiaxin ZHAO ; Chuanjian ZHOU ; Junling WU
West China Journal of Stomatology 2023;41(3):276-283
OBJECTIVES:
The current study aimed to investigate the bonding properties of a novel low-shrinkage resin adhesive containing expanding monomer and epoxy resin monomer after thermal cycling aging treatment.
METHODS:
Expanding monomer of 3,9-diethyl-3,9-dimethylol-1,5,7,11-tetraoxaspiro-[5,5] undecane (DDTU) as an anti-shrinkage additive and unsaturated epoxy monomer of diallyl bisphenol A diglycidyl ether (DBDE) as a coupling agent were synthesized. A blend of DDTU and DBDE at a mass ratio of 1∶1, referred to as "UE", was added into the resin matrix at the mass fraction of 20% to prepare a novel low-shrinkage resin adhesive.Then, the methacrylate resin adhesive without UE was used as the blank control group, and a commercial resin adhesive system was selected as the commercial control group. Moreover, the resin-dentin bonding and micro-leakage testing specimens were prepared for the thermal cycling aging treatment. The bonding strength was tested, the fracture modes were calculated, the bonding fracture surface was observed by scanning electron microscope (SEM), and the dye penetration was used to evaluate the tooth-restoration marginal interface micro-leakage. All the data were analyzed statistically.
RESULTS:
After aging, the dentin bonding strength of the experimental group was (19.20±1.03) MPa without a significant decrease (P>0.05), that of the blank control group was (11.22±1.48) MPa with a significant decrease (P<0.05) and that of the commercial control group was (19.16±1.68) MPa without a significant decrease (P>0.05). The interface fracture was observed as the main fracture mode in each group after thermal cycling by SEM. The fractured bonding surfaces of the experimental group often occurred on the top of the hybrid layer, whereas those of the blank and commercial control groups mostly occurred on the bottom of the hybrid layer. Micro-leakage rating counts of specimens before and after thermal cycling were as follows: the experimental group was primarily 0 grade, thereby indicating that a relatively ideal marginal sealing effect could be achieved (P>0.05); meanwhile, the blank control group was primarily 1 grade, and the penetration depth of dye significantly increased after thermal cycling (P<0.05); the commercial control group was primarily 0 grade without statistical difference before and after thermal cycling (P>0.05), while a significant difference was observed between the commercial control group and experimental group after thermal cycling (P<0.05).
CONCLUSIONS
The novel low-shrinkage resin adhesive containing 20%UE exhibited excellent bonding properties even after thermal cycling aging treatment, thereby showing a promising prospect for dental application.
Composite Resins
;
Dental Bonding
;
Dental Cements
;
Surface Properties
;
Resin Cements
;
Dentin-Bonding Agents
;
Dentin
;
Materials Testing
;
Microscopy, Electron, Scanning
10.In vitro research of oral microscope-assisted implant surface decontamination.
Wenqi SU ; Jingwen LI ; Lishan JIANG ; Wenjie CUI ; Yang ZHAO ; Houxuan LI
West China Journal of Stomatology 2023;41(3):350-355
OBJECTIVES:
To investigate the effect of oral microscope-assisted surface decontamination on implants in vitro.
METHODS:
Twelve implants that fell off because of severe peri-implantitis were collected, and decontamination was carried out on the surfaces of implants through curetting, ultrasound, titanium brushing, and sandblasting at 1×, 8×, or 12.8× magnifications. The number and sizes of residues on the implants' surfaces after decontamination were determined, and the decontamination effect was analyzed according to the thread spacing in the different parts of the thread.
RESULTS:
1) The 8× and 12.8× groups scored lower for implant surface residues than the 1× group (P<0.000 1), and the 12.8× group scored lower than the 8× group (P<0.001); 2) no difference in residue score was found between the wide and narrow thread pitch (P>0.05), and the 8× and 12.8× groups had lower scores than the 1× group (P<0.001); 3) the lowest number of contaminants was observed at the tip of the thread, whereas the highest was observed below the thread, and the difference was significant (P<0.001). However, the thread pitch had no effect on the number of contaminants in different areas (P>0.05); 4) the residue scores of the 8× and 12.8× groups were lower than those of the 1× group at the thread tip and above, sag, and below the thread of the implants (P<0.05).
CONCLUSIONS
Residues on the surfaces of contaminated implants can be effectively removed by using an oral microscope. After decontamination, the residues of pollutants were mainly concentrated below the thread of the implants, and the thread pitch of the implants had no significant effect on the residues.
Humans
;
Dental Implants
;
Decontamination
;
Surface Properties
;
Peri-Implantitis
;
Titanium

Result Analysis
Print
Save
E-mail