1.Establishment of reference values for clot waveform analysis parameters and their clinical application in differentiating acquired hemophilia A from lupus anticoagulant positive conditions
Bin YAN ; Mengchao CUI ; Yuanyuan WEN ; Di WU ; Luyi RU ; Huixin ZOU ; Tianxi HU ; Ruijuan WANG ; Suping ZHAI ; Weipeng DU
Chinese Journal of Laboratory Medicine 2025;48(3):371-377
Objective:To establish reference values for clot waveform analysis (CWA) and analyze their diagnostic efficacy in distinguishing acquired hemophilia A (AHA) and lupus anticoagulant (LA)-positive patients.Methods:Case-Control Study. A total of 391 healthy individuals(260 males and 131 females) with a mean age of 45.53±14.85 years were enrolled at Nanyang central Hospital between January 6, 2023 and October 10, 2024. Prothrombin time (PT), activated partial thromboplastin time (APTT), and thrombin time (TT) were measured to establish reference ranges for the CWA parameters, including maximal reaction velocity (Min1), maximal reaction acceleration (Min2), and maximal reaction deceleration (Max2). A total of 158 definitively diagnosed AHA and LA-positive patients (mean age:42.46±14.83 years), including 34 AHA patients and 124 LA-positive patients, were recruited. The Mann Whitney U test was used to analyze the differences in the CWA parameters between the two groups. The diagnostic efficacy of CWA parameters in distinguishing AHA and LA-positive patients was evaluated using the area under the receiver operating characteristic(ROC) curve AUC and the cut-off values were calculated. Results:The reference values for PT-Min1, APTT-Min1, APTT-Min2, APTT-Max2, TT-Min1, TT-Min2, TT-Max2 were 203.41-516.89, 144.63-324.03, 526.46-1 190.03, -404.96±157.22, 159.17±60.34, 272.29-686.99, and -289.47--113.76, respectively. Compared with the CWA parameters in AHA patients, APTT-Max2 was significantly lower in LA-positive patients [-422.74(-577.50, -239.22) vs. -68.87(-92.85,30.28), Z=-7.43, P<0.01], while PT-Min1, APTT-Min1, APTT-Min2, TT-Min1, TT-Min2 were significantly elevated [287.01(188.03, 382.50) vs. 107.45(90.20, 151.39), 972.88(601.20, 1 351.19) vs. 229.10(118.38, 371.67), Z=6.68, 6.69, all P<0.01]. ROC analysis demonstrated the APTT-CWA parameter exhibited high diagnostic efficacy in patients with AHA (AUC>0.900 for both).Additionally, APTT-Min1 and APTT-Max2 were found to be useful in distinguishing between AHA patients and those with LA-positive status accompanied by APTT prolongation (AUC=0.660, 0.700, respectively). Conclusions:Reference values for CWA parameters were successfully established. The APTT-CWA is useful for differentiating between AHA and LA-positive patients and APTT-Max2 demonstrated a good diagnostic value in differentiating AHA patients from those with LA-positive status accompanied by APTT prolongation.
2.A preclinical and first-in-human study of superstable homogeneous radiolipiodol for revolutionizing interventional diagnosis and treatment of hepatocellular carcinoma.
Hu CHEN ; Yongfu XIONG ; Minglei TENG ; Yesen LI ; Deliang ZHANG ; Yongjun REN ; Zheng LI ; Hui LIU ; Xiaofei WEN ; Zhenjie LI ; Yang ZHANG ; Syed Faheem ASKARI RIZVI ; Rongqiang ZHUANG ; Jinxiong HUANG ; Suping LI ; Jingsong MAO ; Hongwei CHENG ; Gang LIU
Acta Pharmaceutica Sinica B 2025;15(10):5022-5035
Transarterial radioembolization (TARE) is a widely utilized therapeutic approach for hepatocellular carcinoma (HCC), however, the clinical implementation is constrained by the stringent preparation conditions of radioembolization agents. Herein, we incorporated the superstable homogeneous iodinated formulation technology (SHIFT), simultaneously utilizing an enhanced solvent form in a carbon dioxide supercritical fluid environment, to encapsulate radionuclides (such as 131I,177Lu, or 18F) with lipiodol for the preparation of radiolipiodol. The resulting radiolipiodol exhibited exceptional stability and ultra-high labeling efficiency (≥99%) and displayed notable intratumoral radionuclide retention and in vivo stability more than 2 weeks following locoregional injection in subcutaneous tumors in mice and orthotopic liver tumors in rats and rabbits. Given these encouraging findings, 18F was authorized as a radiotracer in radiolipiodol for clinical trials in HCC patients, and showed a favorable tumor accumulation, with a tumor-to-liver uptake ratio of ≥50 and minimal radionuclide leakage, confirming the feasibility of SHIFT for TARE applications. In the context of transforming from preclinical to clinical screening, the preparation of radiolipiodol by SHIFT represents an innovative physical strategy for radionuclide encapsulation. Hence, this work offers a reliable and efficient approach for TARE in HCC, showing considerable promise for clinical application (ChiCTR2400087731).
3.Advances in nanocarrier-mediated cancer therapy: Progress in immunotherapy, chemotherapy, and radiotherapy.
Yue PENG ; Min YU ; Bozhao LI ; Siyu ZHANG ; Jin CHENG ; Feifan WU ; Shuailun DU ; Jinbai MIAO ; Bin HU ; Igor A OLKHOVSKY ; Suping LI
Chinese Medical Journal 2025;138(16):1927-1944
Cancer represents a major worldwide disease burden marked by escalating incidence and mortality. While therapeutic advances persist, developing safer and precisely targeted modalities remains imperative. Nanomedicines emerges as a transformative paradigm leveraging distinctive physicochemical properties to achieve tumor-specific drug delivery, controlled release, and tumor microenvironment modulation. By synergizing passive enhanced permeation and retention effect-driven accumulation and active ligand-mediated targeting, nanoplatforms enhance pharmacokinetics, promote tumor microenvironment enrichment, and improve cellular internalization while mitigating systemic toxicity. Despite revolutionizing cancer therapy through enhanced treatment efficacy and reduced adverse effects, translational challenges persist in manufacturing scalability, longterm biosafety, and cost-efficiency. This review systematically analyzes cutting-edge nanoplatforms, including polymeric, lipidic, biomimetic, albumin-based, peptide engineered, DNA origami, and inorganic nanocarriers, while evaluating their strategic advantages and technical limitations across three therapeutic domains: immunotherapy, chemotherapy, and radiotherapy. By assessing structure-function correlations and clinical translation barriers, this work establishes mechanistic and translational references to advance oncological nanomedicine development.
Humans
;
Neoplasms/radiotherapy*
;
Immunotherapy/methods*
;
Nanoparticles/chemistry*
;
Animals
;
Nanomedicine/methods*
;
Drug Delivery Systems/methods*
;
Drug Carriers/chemistry*
;
Radiotherapy/methods*
4.Establishment of reference values for clot waveform analysis parameters and their clinical application in differentiating acquired hemophilia A from lupus anticoagulant positive conditions
Bin YAN ; Mengchao CUI ; Yuanyuan WEN ; Di WU ; Luyi RU ; Huixin ZOU ; Tianxi HU ; Ruijuan WANG ; Suping ZHAI ; Weipeng DU
Chinese Journal of Laboratory Medicine 2025;48(3):371-377
Objective:To establish reference values for clot waveform analysis (CWA) and analyze their diagnostic efficacy in distinguishing acquired hemophilia A (AHA) and lupus anticoagulant (LA)-positive patients.Methods:Case-Control Study. A total of 391 healthy individuals(260 males and 131 females) with a mean age of 45.53±14.85 years were enrolled at Nanyang central Hospital between January 6, 2023 and October 10, 2024. Prothrombin time (PT), activated partial thromboplastin time (APTT), and thrombin time (TT) were measured to establish reference ranges for the CWA parameters, including maximal reaction velocity (Min1), maximal reaction acceleration (Min2), and maximal reaction deceleration (Max2). A total of 158 definitively diagnosed AHA and LA-positive patients (mean age:42.46±14.83 years), including 34 AHA patients and 124 LA-positive patients, were recruited. The Mann Whitney U test was used to analyze the differences in the CWA parameters between the two groups. The diagnostic efficacy of CWA parameters in distinguishing AHA and LA-positive patients was evaluated using the area under the receiver operating characteristic(ROC) curve AUC and the cut-off values were calculated. Results:The reference values for PT-Min1, APTT-Min1, APTT-Min2, APTT-Max2, TT-Min1, TT-Min2, TT-Max2 were 203.41-516.89, 144.63-324.03, 526.46-1 190.03, -404.96±157.22, 159.17±60.34, 272.29-686.99, and -289.47--113.76, respectively. Compared with the CWA parameters in AHA patients, APTT-Max2 was significantly lower in LA-positive patients [-422.74(-577.50, -239.22) vs. -68.87(-92.85,30.28), Z=-7.43, P<0.01], while PT-Min1, APTT-Min1, APTT-Min2, TT-Min1, TT-Min2 were significantly elevated [287.01(188.03, 382.50) vs. 107.45(90.20, 151.39), 972.88(601.20, 1 351.19) vs. 229.10(118.38, 371.67), Z=6.68, 6.69, all P<0.01]. ROC analysis demonstrated the APTT-CWA parameter exhibited high diagnostic efficacy in patients with AHA (AUC>0.900 for both).Additionally, APTT-Min1 and APTT-Max2 were found to be useful in distinguishing between AHA patients and those with LA-positive status accompanied by APTT prolongation (AUC=0.660, 0.700, respectively). Conclusions:Reference values for CWA parameters were successfully established. The APTT-CWA is useful for differentiating between AHA and LA-positive patients and APTT-Max2 demonstrated a good diagnostic value in differentiating AHA patients from those with LA-positive status accompanied by APTT prolongation.
5.Clinical analysis of different types of neonatal sepsis: a multi-center retrospective study
Yuanqiang YU ; Qingyi DONG ; Suping LI ; Huaxue QI ; Xin TAN ; Hong OUYANG ; Jintao HU ; Wen LI ; Tao WANG ; Yonghui YANG ; Xiaoyun GONG ; Xiaori HE ; Pingyang CHEN
Chinese Journal of Neonatology 2023;38(5):257-261
Objective:To study the clinical characteristics of different types of neonatal sepsis.Methods:From January 2012 to December 2019, neonates with confirmed sepsis from 5 neonatal centers of central-south China were reviewed. The neonates were assigned into early-onset sepsis (EOS) and late-onset sepsis (LOS) group, and the latter was further subgrouped into hospital-acquired LOS (hLOS) group and community-acquired LOS (cLOS) group. The etiological and clinical characteristics were analyzed. SPSS 26.0 was used for statistical analysis.Results:A total of 580 neonates were enrolled, including 286 (49.3%) in the EOS group and 294 (50.7%) in the LOS group. In LOS group, 147 were in hLOS group and 147 were in cLOS group. The gestational age and birth weight of hLOS group were significantly lower than the other two groups [(32.7±3.6) weeks vs. (37.1±3.7) weeks and (37.7±3.0) weeks, (1 810±717) g vs. (2 837±865) g and (3 024±710) g] ( P<0.05). The common pathogens in EOS and cLOS groups were coagulase-negative staphylococci and Escherichia coli, while Klebsiella pneumoniae was common in hLOS group. Carbapenems usage in the hLOS group was significantly higher than the other two groups [62.6% vs. 28.7% and 16.2%] ( P<0.05). Antibiotics duration in the hLOS group was longer than the other two groups [19 (14, 27) d vs. 15 (12, 20) d and 14 (12, 19) d] ( P<0.05). Conclusions:The clinical characteristics of neonatal sepsis vary among different types of infections, and it is necessary to establish appropriate prevention, control, diagnosis and treatment protocols.
6.Oxygen concentration threshold for explosion induced by high-frequency electric knife or argon knife at different energies
Suping LYU ; Gaifang ZHENG ; Shengqun LIU ; Zhenhua HU ; Changyun YANG
Chinese Journal of Anesthesiology 2022;42(12):1445-1447
Objective:To determine the oxygen concentration threshold for explosion induced by high-frequency electric knife or argon knife at different energies.Methods:① In vivo experiment The smooth muscle tissue or adipose-rich tissue in 10 pairs of isolated porcine lungs and trachea was electrocauterized at 30 and 50 W with high-frequency electroknife or argon knife at different oxygen concentrations.The initial oxygen concentration was 20%, the oxygen concentration was gradually increased in increments of 5% until the oxygen concentration reached 80%.Each sample was electrocauterized 10 times at each concentration, and the number of explosion was recorded.As long as one explosion occurred, it could be considered that the concentration could induce explosion, and the minimum oxygen concentration inducing explosion was considered as the threshold.② Measurement of oxygen concentration in the airway of patients received bronchoscopic intervention Thirty patients scheduled for elective bronchoscopy with cryotherapy were selected, the oxygen concentration inhaled was reduced from 100% until 50% in decrements of 10%, and the oxygen concentration in airway was measured with the AIRVO 2 transnasal high-flow oxygen inhalation device.ICC consistency analysis was performed between the oxygen concentration in airway and oxygen concentration inhaled. Results:In adipose-rich tissues, the threshold of the oxygen concentration for explosion was 70% at 30 W and 65% at 50 W when using the high-frequency electric knife; the threshold of the oxygen concentration for explosion was 35% at 30 W and 30% at 50 W when using the high-frequency argon knife.In smooth muscle tissues, no explosion occurred at each oxygen concentration when using the high-frequency electric knife and argon knife at 30 or 50 W, and the threshold value was above 80%.There was moderate consistency (ICC value 0.722, 95% CI 0.537-0.850, P<0.001) between the oxygen concentration in airway and oxygen concentration inhaled. Conclusions:In smooth muscle tissues, explosion is not easy to occur at oxygen concentrations below 80% when using the high-frequency electric knife or argon knife.In adipose-rich tissues, explosion is not easy to occur at oxygen concentrations less than 70% at 30 W and at oxygen concentrations less than 65% at 50 W when using the high-frequency electric knife; explosion is not easy to occur at oxygen concentrations less than 35% at 30 W and at oxygen concentrations less than 30% at 50 W when using the high-frequency argon knife.The threshold of oxygen concentrations in airway can be determined using the oxygen concentration inhaled.
7.The reverse homodigital dorsal thumb flap for thumb pulp defect reconstruction
Genqun LI ; Guozeng LI ; Yiting HU ; Suping JIANG ; Huanning ZHANG ; Chao GUO ; Nannan XIA ; Qichao LI
Chinese Journal of Plastic Surgery 2022;38(3):311-315
Objective:To summarize the effect of reverse homodigital dorsal thumb flap in repairing thumb pulp defect.Methods:A retrospective case series study was conducted to analyze the clinical data of patients with thumb pulp defects admitted to the People's Hospital of Renqiu from March 2010 to June 2020. The dorsal homodigital island flap of the proximal phalanx was designed and harvested. During the procedure, the proximal digital artery of the perforator vessels of the flap was cut off and ligated. The digital artery pedicled flap was retrograde transferred to cover the thumb pulp defect. 9-0 line was used to anastomose the dorsal digital nerve with the proper digital nerve. The donor site was repaired with a free skin graft.Results:A total of 68 cases of thumb pulp defects were enrolled, all of whom were accompanied by exposure of the tendon of the distal phalanx. There were 39 males and 29 females, aged from 18 to 63 years (average of 35.8 years). The size of the proximal dorsal island flap was 2.0 cm × 3.0 cm to 3.1 cm × 4.2 cm. All flaps and skin grafts survived, and wounds healed primarily. All patients were followed up for 6 to 28 months (mean, 10.6 months). The color, texture, and contour of the flaps were good. All repaired thumbs got the normal function of extension and flexion. At the last follow-up, the two-point discrimination of flaps was 4-11 mm.Conclusions:It has the advantages of small trauma, simple operation, and good curative effect, using the homodigital dorsal thumb flap to repair the thumb pulp defect.
8.The reverse homodigital dorsal thumb flap for thumb pulp defect reconstruction
Genqun LI ; Guozeng LI ; Yiting HU ; Suping JIANG ; Huanning ZHANG ; Chao GUO ; Nannan XIA ; Qichao LI
Chinese Journal of Plastic Surgery 2022;38(3):311-315
Objective:To summarize the effect of reverse homodigital dorsal thumb flap in repairing thumb pulp defect.Methods:A retrospective case series study was conducted to analyze the clinical data of patients with thumb pulp defects admitted to the People's Hospital of Renqiu from March 2010 to June 2020. The dorsal homodigital island flap of the proximal phalanx was designed and harvested. During the procedure, the proximal digital artery of the perforator vessels of the flap was cut off and ligated. The digital artery pedicled flap was retrograde transferred to cover the thumb pulp defect. 9-0 line was used to anastomose the dorsal digital nerve with the proper digital nerve. The donor site was repaired with a free skin graft.Results:A total of 68 cases of thumb pulp defects were enrolled, all of whom were accompanied by exposure of the tendon of the distal phalanx. There were 39 males and 29 females, aged from 18 to 63 years (average of 35.8 years). The size of the proximal dorsal island flap was 2.0 cm × 3.0 cm to 3.1 cm × 4.2 cm. All flaps and skin grafts survived, and wounds healed primarily. All patients were followed up for 6 to 28 months (mean, 10.6 months). The color, texture, and contour of the flaps were good. All repaired thumbs got the normal function of extension and flexion. At the last follow-up, the two-point discrimination of flaps was 4-11 mm.Conclusions:It has the advantages of small trauma, simple operation, and good curative effect, using the homodigital dorsal thumb flap to repair the thumb pulp defect.
9.Reverse proximal dorsal island flap pedicled with the radial digital artery of the thumb for repair of thumb tip defects
Qichao LI ; Suping JIANG ; Genqun LI ; Yiting HU ; Guozeng LI ; Huanning ZHANG ; Chao GUO ; Nannan XIA
Chinese Journal of Trauma 2021;37(11):984-989
Objective:To investigate the therapeutic effect of reverse proximal segment dorsal flap of radial digital artery of the thumb in repairing thumb tip defects.Methods:A retrospective case series study was conducted to analyze the clinical data of 56 patients with thumb tip defects admitted to Renqiu People 's Hospital from February 2010 to October 2020. There were 37 males and 19 females,aged 17-66 years[(37.8±12.2)years]. The injury on the right side was observed in 35 patients and on the left side in 21 patients. All of them were thumb tip defects with exposed distal phalanx. Dimension of skin defects was 2.9 cm×1.8 cm-3.3 cm×2.6 cm.The reverse proximal segment dorsal flap of thumb radial digital artery was used,with the dorsal digital nerve sutured with the proper digital nerve. The donor site was repaired with free skin graft from the ulnar side of the affected forearm. The time of flap harvesting,operation time and healing of the flap were measured. At the last follow-up,the shape,texture,sensory recovery and complications of the flap were observed. One month after operation and at the latest follow-up,the upper limb function evaluation standard set up by hand surgery branch of Chinese Medical Association and Vancouver Scar Scale(VSS)score were used to evaluate the recovery of sensory function of the flap and scar formation of the donor sites,respectively. Results:All patients were followed up for 6-26 months[(13.2±6.4)months]. The time of flap harvesting ranged from 20 to 35 minutes[(26.0±5.3)minutes]. The operation time was 1-2 hours[(1.3±0.3)hours]. Blisters appeared at the distal end of the flap in 2 patients after operation,but they were not treated. After 7 days,the blisters subsided and the flaps survived. The other flaps survived successfully. The donor sites healed by first intention. At the last follow-up,the flaps showed relatively cosmetic appearance,similarities in texture,elasticity and color to the surrounding area and good sensory recovery,without scar contracture and dystrophy of interphalangeal joint. According to the upper limb function evaluation standard set up by hand surgery branch of Chinese Medical Association,56 patients exceeded S3 grade compared to none at postoperative 1 month( P<0.01),and the VSS score was 3-7 points[(5.0±1.4)points]compared to 6-12 points[(8.8±1.5)points]at postoperative 1 month( P<0.01). The donor site left a linear scar,which had no significant effect on its shape and function. Conclusion:The reverse proximal segment dorsal flap of the radial digital artery of the thumb can be used to repair thumb tip defects,for it has advantages of easy operation,a high survival rate as well as good appearance and sensory function recovery,with less damage to the donor area.
10.Proximal thumb dorsal transverse flap for tissue defects at thumb pulp and fingertip
Qichao LI ; Genqun LI ; Yiting HU ; Guozeng LI ; Huanning ZHANG ; Chao GUO ; Suping JIANG ; Nannan XIA
Chinese Journal of Orthopaedic Trauma 2021;23(11):995-999
Objective:To report our clinical efficacy of pedicled transplantation of proximal thumb dorsal transverse flap to repair tissue defects at thumb pulp and fingertip.Methods:From February 2010 to November 2020, 97 patients with tissue defects at thumb pulp and fingertip were treated by pedicled transplantation of proximal thumb dorsal transverse flap at Department of Orthopedics, People's Hospital of Renqiu. They were 55 men and 42 women, aged from 17 to 66 years (average, 41.3 years). Altogether 55 right and 42 left sides were affected. The size of soft tissue defects ranged from 2.8 cm×1.8 cm to 3.9 cm×2.8 cm. Postoperatively, flap survival, shape, color and sensory recovery at the recipient area were observed; wound healing, function and complications at the donor site were also observed.Results:All the 97 flaps survived and all the wounds healed at the first stage. Blisters appeared at the distal end of the flap in only 2 cases but subsided 7 days after operation with no special treatment and the flaps survived smoothly. All the skin grafts at the donor site survived uneventfully. The 97 patients were followed up for 6 to 26 months (average, 10.7 months). Their flaps were not swollen, finger abdomen was full, finger appearance satisfactory, and finger feeling recovered well. The two-point discrimination at the last follow-up ranged from 4 to 11 mm (average, 7.6 mm). By the trial criteria for assessment of upper limb function suggested by Hand Surgery Society of Chinese Medical Association, sensory function of the affected finger was assessed as S 4 in 21 cases and as S 3+ in 76 cases at the last follow-up. No scar contracture was observed at the donor site and no movement restriction at the interphalangeal joint. Conclusion:Proximal thumb dorsal transverse flap is a reliable choice for reconstruction of complex tissue defects at thumb pulp and fingertip because of the advantages of easy harvest, constant vascular anatomy, full appearance and good sensory function at the recipient site, and limited damage to the donor site.

Result Analysis
Print
Save
E-mail