1.The effect of suction curettage on the visualization, operative time, fluid deficit, and histopathological diagnosis among perimenopausal women with abnormal uterine bleeding and unprepared endometrium for operative hysteroscopy: A single-center randomized controlled trial
Andy Teodoro Kwan Paningbatan ; Zoraida Umipig-Guevara
Philippine Journal of Obstetrics and Gynecology 2024;48(4):255-260
INTRODUCTION
Hysteroscopy is the gold standard procedure for the evaluation and diagnosis of intrauterine pathologies. The optimal time to do hysteroscopy is during the proliferative phase. However, for women with irregular bleeding, the optimal time is unpredictable. Besides pharmacological means, mechanical endometrial preparation could be done.
OBJECTIVEThe objective of this study was to determine the effect of suction curettage on visualization, operative time, fluid deficit, and histopathologic diagnosis among perimenopausal women with abnormal uterine bleeding (AUB) and unprepared endometrium prior to operative hysteroscopy.
METHODOLOGYThirty-four (34) perimenopausal women admitted for AUB with unprepared endometrium for operative hysteroscopy who consented to participate were recruited and randomly divided into two groups: 18 women had suction curettage done prior to operative hysteroscopy and 16 women had operative hysteroscopy done alone. The following data were obtained for each group: (1) improvement in clarity (i.e., visualization of fundus and both tubal ostia), (2) operative time from entry to withdrawal of the resectoscope (measured in minutes), (3) fluid deficit, and (4) final histopathological diagnosis. P
RESULTSWomen who underwent suction curettage prior to operative hysteroscopy had improved visualization (72.2%, P < 0.001), shorter operative time (29.06 ± 7.06 min vs. 35.5 ± 7.2 min, P = 0.013), no difference in fluid deficit (P = 0.276), and the histopathologic diagnosis (P = 0.470).
CONCLUSIONSuction curettage prior to operative hysteroscopy among perimenopausal women with AUB and unprepared endometrium improved visualization and shortened operative time without affecting fluid deficit and histopathologic diagnosis.
Hysteroscopy ; Suction Curettage ; Vacuum Curettage
2.Efficacy of abdominal and transanal lavage-suction drainage system for early anastomotic leakage after neoadjuvant chemoradiotherapy and surgery for rectal cancer.
Sheng Hui HUANG ; Pan CHI ; Ying HUANG ; Xiao Jie WANG ; Wei Zhong JIANG
Chinese Journal of Gastrointestinal Surgery 2022;25(8):734-737
3.Clinical application of a self-developed suction-irrigation device in endoscopic ear surgery for attic cholesteatoma.
Yang LI ; Ying SHENG ; Jun Li WANG ; Li GUO ; Ye Ye YANG ; Ju Lin LI ; Ting WANG ; Bao Jun WU ; Xiao Yong REN
Chinese Journal of Otorhinolaryngology Head and Neck Surgery 2022;57(11):1319-1322
Objective: To introduce a new self-developed irrigation device(SID) that does not employ a sheath or an irrigation-suction system and evaluate to its efficiency in transcanal endoscopic ear surgery (TEES) for attic cholesteatoma. Methods: 38 patients who were subjected to TEES for attic cholesteatoma between October 2019 to June 2021 were included in this study, including 17 males and 21 females with an average age of (38.6±11.9) years. SID and underwater continuous drilling were used during operation. Width of endoscope and irrigation speed were measured when SID was applied. The operating time, surgical view and complications were compared between two groups. Results: The width of the endoscope was 3.5-4.6 mm in diameter and the irrigation speed was 20-40 ml/min when SID was used. SID cleaned the lens at the tip of the endoscope and created a clear field of view during TEES. The operation time was (86.6±18.1) min. The skin of the external ear canal was found injured during operation in 3 patients, but there were no complications such as necrosis of the flap, stenosis of external ear canal, sensorineural hearing loss, facial paralysis and cerebrospinal fluid leakage. Conclusions: SID is simple and enhances the efficacy of TEES, providing a new irrigation choice in TEES for attic cholesteatoma.
Humans
;
Male
;
Female
;
Adult
;
Middle Aged
;
Cholesteatoma, Middle Ear/surgery*
;
Suction
;
Sudden Infant Death
;
Otologic Surgical Procedures
;
Ear, Middle/surgery*
5.A retrospective cohort study of tracheal intubation for meconium suction in nonvigorous neonates.
Chinese Journal of Contemporary Pediatrics 2022;24(1):65-70
OBJECTIVES:
To study the feasibility of tracheal intubation for meconium suction immediately after birth of nonvigorous neonates born through meconium-stained amniotic fluid (MSAF).
METHODS:
A retrospective cohort study was performed on nonvigorous neonates born through MSAF who were admitted to the Department of Neonatology, Zhecheng People's Hospital. The neonates without meconium suction who were admitted from July 1, 2017 to June 30, 2018 were enrolled as the control group. The neonates who underwent meconium suction from July 1, 2018 to June 30, 2019 were enrolled as the suction group. The two groups were compared in terms of the mortality rate and the incidence rates of neonatal meconium aspiration syndrome (MAS), persistent pulmonary hypertension of the newborn, pneumothorax, and pulmonary hemorrhage.
RESULTS:
There were 80 neonates in the control group and 71 in the suction group. There were no significant differences between the two groups in the incidence rates of MAS (11% vs 7%), persistent pulmonary hypertension of the newborn (5% vs 4%), pneumothorax (3% vs 1%), and death (0% vs 1%). Compared with the control group, the suction group had a significantly lower proportion of neonates requiring oxygen inhalation (16% vs 33%, P<0.05), noninvasive respiratory support (25% vs 41%, P<0.05) or mechanical ventilation (10% vs 23%, P<0.05) and significantly shorter duration of noninvasive ventilation [(58±24) hours vs (83±41) hours, P<0.05] and length of hospital stay [6(4, 8) days vs 7(5, 10) days, P<0.05].
CONCLUSIONS
Although tracheal intubation for meconium suction immediately after birth may shorten the duration of respiratory support for mild respiratory problems, it cannot reduce the incidence rate of MAS, mortality rate, or the incidence rate of serious complications in nonvigorous infants born through MSAF.
Amniotic Fluid
;
Humans
;
Infant
;
Infant, Newborn
;
Intubation, Intratracheal
;
Meconium
;
Meconium Aspiration Syndrome/therapy*
;
Retrospective Studies
;
Suction
6.Design of Integrated Suction Detection System for Pediatric Oral Secretion.
Geer YANG ; Zhirong TONG ; Jincheng ZOU ; Jinlong LIU
Chinese Journal of Medical Instrumentation 2020;44(6):503-507
According to the actual requirements of pediatric intensive care, a suction detection system of pediatric oral secretions integrated with monitoring function is designed. The system has the function of adjustable intermittent attraction. The duration and proportion of intermittent attraction can be adjusted according to the individualized needs of pediatric intensive care. The suction head of pacifier can reduce the mechanical damage to pediatric oral mucosa as much as possible. Meanwhile, the system can detect and monitor the real-time biochemical indexes of the collected oral secretions, which can be used to help the judgement of aspiration and quantitatively evaluate the microcirculation dysfunction.
Bodily Secretions
;
Child
;
Humans
;
Mouth
;
Suction/instrumentation*
7.2020 clinical practice guidelines of endotracheal suctioning in neonates with mechanical ventilation.
Chinese Journal of Contemporary Pediatrics 2020;22(6):533-542
Endotracheal suctioning is a most frequent invasive procedure in neonates undergoing mechanical ventilation. The procedure includes the patient preparation, airway suctioning and follow-up care, which may associated with adverse events. Based on the Grading of Recommendations Assessment, Development and Evaluation (GRADE), as well as the related research both in China and overseas, the clinical practice guidelines of endotracheal suctioning in neonates with mechanical ventilation is developed in order to promote the standard implementation of this operation and ensure patients' safety.
China
;
Humans
;
Infant, Newborn
;
Intubation, Intratracheal
;
Respiration, Artificial
;
Suction
;
Trachea
8.Role of Suction Drain after Knee Arthroplasty in the Tranexamic Acid Era: A Randomized Controlled Study
Rajesh Navin MANIAR ; Prashant PRADHAN ; Nishit BHATNAGAR ; Adit MANIAR ; Rohan BIDWAI ; Pranav BINDAL
Clinics in Orthopedic Surgery 2019;11(1):73-81
BACKGROUND: Postoperative suction drains are used after total knee arthroplasty to avoid intra-articular hematoma formation although they can increase blood loss due to a negative suction effect. The use of tranexamic acid to reduce blood loss may nullify this. The aim of this study was to compare outcomes in patients undergoing total knee arthroplasty with or without drains and to analyze whether the drain's diameter also has an impact. METHODS: This is a prospective randomized study of patients undergoing unilateral total knee arthroplasty performed by a single surgeon. The study population was divided into three groups (A, 10G drain; B, 12G drain; and C, no drain). Pain, blood loss, swelling, wound-related complications, functional outcomes and questionnaire-based outcomes were assessed postoperatively. RESULTS: Each group had 35 patients comparable in most demographic and pre- and intraoperative characteristics. During the first 6 hours postoperatively, opioid consumption was significantly higher when the drain was not used (p = 0.036). At 3 months postoperatively, new Knee Society Score (NKSS) was highest with the use of 12G drain (p = 0.018). However, NKSS at 1 year was comparable across the three groups. With the use of tranexamic acid, blood loss and incidence of soakage of dressing were unaffected by the presence or absence of a drain. The calf girth, suprapatellar girth, soakage of dressing and range of motion were comparable in all three groups. There was no incidence of surgical site infection or deep vein thrombosis. CONCLUSIONS: Presence of a suction drain significantly reduces opioid consumption during the first 6 hours after total knee arthroplasty. Use of a drain made no difference to the functional outcome at 1 year postoperatively. With the use of tranexamic acid in total knee arthroplasty, the total blood loss and the requirement of blood transfusion were unaffected by the presence or absence of closed suction drainage or by the bore of the drain used. The clinical parameters such as swelling, range of motion, infection and deep vein thrombosis also remained the same.
Arthroplasty
;
Arthroplasty, Replacement, Knee
;
Bandages
;
Blood Transfusion
;
Drainage
;
Hematoma
;
Humans
;
Incidence
;
Knee
;
Osteoarthritis, Knee
;
Prospective Studies
;
Range of Motion, Articular
;
Suction
;
Surgical Wound Infection
;
Tranexamic Acid
;
Venous Thrombosis
9.Development of Thrombus Aspiration Catheter.
Xiuheng HAN ; Shuxia DUAN ; Shuaichao LIU ; Peilong SHI ; Cong CHANG ; Yingkun FU ; Zhengnan ZHANG ; Ningjian AO
Chinese Journal of Medical Instrumentation 2019;43(2):106-108
Coronary disease is one of the highest mortality diseases in the world,and interventional therapy has been the best treatment choice for its low risks,high efficiency,less wound and rapid recovery after the operation.Thrombus aspiration catheter is one of the most important equipment in the interventional therapy instrument of coronary disease.This paper is based on the demand of clinical and market,designed and manufactured aspirated catheter for the treatment of coronary thrombosis.Through the performance comparison of the material,confirmed the main material quality of thrombus aspiration catheter and its organization.We also made the appraisement for the function of the material and the main performance of the thrombus aspiration catheter.The experiment turned out that our catheter performance is stable and also with highly reliable,which is absolutely fit for the using requirements of the clinical.
Catheters
;
Coronary Angiography
;
Coronary Thrombosis
;
therapy
;
Humans
;
Suction
;
Thrombectomy
;
instrumentation
;
Treatment Outcome
10.Development of Motion Unit of Simulated Intelligent Endotracheal Suctioning Robot.
Wenjun TAN ; Cunyi SHEN ; Yu LUO ; Haoyang ZHU ; Tao MA ; Dinghui DONG ; Aihua SHI ; Zhao XUE ; Rongqian WU ; Y LYU
Chinese Journal of Medical Instrumentation 2019;43(1):17-20
A motion unit for sucking robot with a stable motion, convenient operation and process simulation is introduced. The key parameters and process data of the sucking operation were obtained from the clinical work, which provided the basis for the design of the sucking robot motion unit. According to the points of sucking action, robotic thumb, forefinger and metacarpophalangeal joints were used to grip the suction tube, and the servo and arm structure were used to simulate the motion of the wrist and elbow to complete the rotation and push of the sputum suction tube. The feasibility is verified through the advanced sputum suction training model. The movement unit is stable in movement, and can smoothly complete the clamping, feeding, back off protection and rotating tube removal of the sputum suction tube, so as to achieve effective sputum suction.
Catheterization
;
Intubation, Intratracheal
;
Robotics
;
Suction


Result Analysis