1.Establishment and Preliminary Analysis of an AG6 Mouse Encephalopathy Model Induced by Vaccinia Virus Tiantan Strain Infection
Lin YANG ; Meng JIN ; Hanqing WU ; Shun LI ; Xiaohui ZHOU
Laboratory Animal and Comparative Medicine 2026;46(1):3-10
ObjectiveA mouse model of vaccinia virus Tiantan strain (VTT)-induced encephalopathy was developed using AG6 mice. MethodsVTT was amplified by infecting Vero cells at a multiplicity of infection (MOI) of 0.01, followed by concentration and titration. After 72 h of incubation, virus-containing cells were collected and subjected to concentration. The concentrated viral suspension was serially diluted (10-fold dilutions) and added to 6-well plates containing confluent Vero cell monolayers for plaque assay. The number of plaques formed in each well was counted, and the virus titer was calculated based on the dilution factor. Fourteen 5-6-week-old AG6 mice (half male and half female, housed separately by sex) were randomly divided into a control group (n=3, PBS), a low-dose group (n=6, 1×10⁵ PFU), and a high-dose group (n=5, 5×10⁵ PFU). The mice were anesthetized by isoflurane inhalation and then infected via intranasal instillation. The mental state of the mice in each group was observed daily, and the body weight and mortality were recorded. On day 13 post-infection, 2% Evans Blue (4 mL/kg body weight) was administered via tail vein injection to assess blood-brain barrier (BBB) disruption. Subsequently, brain tissue samples were collected for immunofluorescence analysis to evaluate the activation of astrocytes and microglia. ResultsThe titer of purified VTT was 1×10⁷ PFU/mL. Compared with the control group, mice in the low-dose group showed no significant change in body weight, and no lethality was observed. In contrast, mice in the high-dose group exhibited significant weight loss starting on day 5 post-infection (P<0.05), accompanied by lethality. On day 13 post-infection, no Evans Blue extravasation was detected in the brain tissues of the low-dose group, while the olfactory bulb region of the high-dose group displayed distinct blue staining, indicating disruption of the BBB. Immunofluorescence analysis revealed no significant proliferation of astrocytes and microglia in the olfactory bulb region of the low-dose group on day 13 post-infection. In contrast, marked activation of glial cells was observable in the high-dose group. ConclusionAn animal model of VTT-induced encephalopathy in AG6 mice is successfully established, characterized by BBB disruption and reactive gliosis specifically localized to the olfactory bulb region, manifested as astrocytic and microglial proliferation.
2.Response to Comments on “Pretreatment 68Ga-PSMA-11 PET/CT to Predict the Response to Treatment With Immune Checkpoint Inhibitors Plus Tyrosine Kinase Inhibitors in Patients With Metastatic Renal Cell Carcinoma”
Shao-Hao CHEN ; Xiao-Hui WU ; Qian-Ren-Shun QIU ; Shao-Ming CHEN ; Jie ZANG ; Jun-Ming ZHU ; Cheng-Long ZENG ; Wei-Bing MIAO ; Xue-Yi XUE ; Ning XU
Korean Journal of Radiology 2026;27(2):188-190
3.Rapid quality control method for automated organ-at-risk contouring in head and neck radiotherapy
Xiaoyu YANG ; Kaining YAO ; Yichen PU ; Shun ZHOU ; Ruoxi WANG ; Haizhen YUE ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):193-199
Objective To address the need for rapid review of automated organ-at-risk (OAR) contouring for head-and-neck cancer in online adaptive radiotherapy, this study used dosimetric indices as the reference standard to evaluate the suitability of geometric similarity metrics and to develop a rapid screening model that balances the risk of missed errors with review efficiency. Methods This retrospective study included 29 patients with head-and-neck radiotherapy, yielding 243 pairs of OAR contours (auto-generated vs. manual). Geometric similarity metrics, including the Dice similarity coefficient (Dice), the 95th percentile Hausdorff distance (HD95), and the maximum Hausdorff distance (HD100), were computed between the two contour sets. Using the dose distributions from clinical treatment plans, dosimetric differences between the two contour sets were calculated for key indices, including mean dose (Dmean) and maximum dose (Dmax). Correlations between geometric metrics and dosimetric differences were analyzed. Dosimetric discrepancy events were defined as Y3Gy using a threshold of 3 Gy. Within a univariable logistic regression triage framework, each geometric metric was used as an independent variable to estimate the probability of Y3Gy. Discriminative performance was assessed using receiver operating characteristic (ROC) curves and precision-recall (PR) curves, with the area under the curve (AUC) including ROC-AUC and PR-AUC. Practical operating thresholds were determined via threshold sweeping. Results Geometric similarity metrics showed weak-to-moderate correlations with dosimetric differences; compared with maximum dose, correlations with mean dose differences were more consistent. Among the evaluated metrics, HD95 achieved the best classification performance for Y3Gy. Threshold sweeping suggested that an HD95 threshold in the range of 4-9 mm can balance the risk of missed discrepancies with the efficiency of automated contour quality assurance (QA). Conclusion Several geometric similarity metrics demonstrated only weak-to-moderate associations with dosimetric differences. For head-and-neck OAR contour QA in this study, HD95 provided the best discriminative performance and can support rapid triage of automated contours, with a practical operating threshold range of 4-9 mm, potentially improving the efficiency of adaptive radiotherapy workflows.
4.A preliminary study on a method for detecting accelerator isocenter deviation using an optical surface monitoring system
Jianqi HU ; Shun ZHOU ; Jiangyan LUO ; Zihong LU ; Junyu LI ; Wen WANG ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):263-271
Objective To detect the isocenter of a medical linear accelerator using an optical surface monitoring system (OSMS) combined with a self-made 3D-printed phantom, and compare with the conventional front pointer measurement method. Methods A phantom that could be fixed to the front pointer of the accelerator was fabricated using 3D printing technology. The front pointer method and OSMS were used to detect the rotation isocenter deviations of the accelerator. During the experiments, the collimator, gantry, and couch linear displacement readings were recorded at different angles. We also recorded the measurement time of different surveyors. Results Compared to the front pointer measurement method, the OSMS method showed lower standard deviations. The reductions in standard deviations showed statistical significance in the Lat direction for the collimator rotation isocenter as well as in the Lat and Vrt directions for the gantry rotation isocenter. The mean deviation of Mag values for the collimator rotation isocenter using the OSMS method was 0.50 mm, which was larger than the 0.42 mm using the front pointer method. However, the standard deviation was 0.06 using the OSMS method, which was smaller than the 0.18 using the front pointer method. The mean deviation and standard deviation of Sag values for the gantry rotation isocenter using the OSMS method were 1.03 mm and 0.12, respectively, which were both larger than 0.47 mm and 0.06 using the front pointer method. For the couch rotation isocenter, the mean deviation and standard deviation using the OSMS method were 0.32 mm and 0.04, respectively, which were both smaller than the 0.55 mm and 0.20 using the front pointer method. All surveyors spent less time in isocenter measurements using the OSMS method compared to the front pointer method. Conclusion Compared with the front pointer method, the OSMS method significantly reduces the standard deviation among surveyors, effectively reduces the influence of the angle deviation of the accelerator on the measurement results, reduces detection time, improves detection efficiency, and provides a powerful practical basis for the application of OSMS in detecting the mechanical accuracy of the linear accelerator.
5.Rapid quality control method for automated organ-at-risk contouring in head and neck radiotherapy
Xiaoyu YANG ; Kaining YAO ; Yichen PU ; Shun ZHOU ; Ruoxi WANG ; Haizhen YUE ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):193-199
Objective To address the need for rapid review of automated organ-at-risk (OAR) contouring for head-and-neck cancer in online adaptive radiotherapy, this study used dosimetric indices as the reference standard to evaluate the suitability of geometric similarity metrics and to develop a rapid screening model that balances the risk of missed errors with review efficiency. Methods This retrospective study included 29 patients with head-and-neck radiotherapy, yielding 243 pairs of OAR contours (auto-generated vs. manual). Geometric similarity metrics, including the Dice similarity coefficient (Dice), the 95th percentile Hausdorff distance (HD95), and the maximum Hausdorff distance (HD100), were computed between the two contour sets. Using the dose distributions from clinical treatment plans, dosimetric differences between the two contour sets were calculated for key indices, including mean dose (Dmean) and maximum dose (Dmax). Correlations between geometric metrics and dosimetric differences were analyzed. Dosimetric discrepancy events were defined as Y3Gy using a threshold of 3 Gy. Within a univariable logistic regression triage framework, each geometric metric was used as an independent variable to estimate the probability of Y3Gy. Discriminative performance was assessed using receiver operating characteristic (ROC) curves and precision-recall (PR) curves, with the area under the curve (AUC) including ROC-AUC and PR-AUC. Practical operating thresholds were determined via threshold sweeping. Results Geometric similarity metrics showed weak-to-moderate correlations with dosimetric differences; compared with maximum dose, correlations with mean dose differences were more consistent. Among the evaluated metrics, HD95 achieved the best classification performance for Y3Gy. Threshold sweeping suggested that an HD95 threshold in the range of 4-9 mm can balance the risk of missed discrepancies with the efficiency of automated contour quality assurance (QA). Conclusion Several geometric similarity metrics demonstrated only weak-to-moderate associations with dosimetric differences. For head-and-neck OAR contour QA in this study, HD95 provided the best discriminative performance and can support rapid triage of automated contours, with a practical operating threshold range of 4-9 mm, potentially improving the efficiency of adaptive radiotherapy workflows.
6.A preliminary study on a method for detecting accelerator isocenter deviation using an optical surface monitoring system
Jianqi HU ; Shun ZHOU ; Jiangyan LUO ; Zihong LU ; Junyu LI ; Wen WANG ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):263-271
Objective To detect the isocenter of a medical linear accelerator using an optical surface monitoring system (OSMS) combined with a self-made 3D-printed phantom, and compare with the conventional front pointer measurement method. Methods A phantom that could be fixed to the front pointer of the accelerator was fabricated using 3D printing technology. The front pointer method and OSMS were used to detect the rotation isocenter deviations of the accelerator. During the experiments, the collimator, gantry, and couch linear displacement readings were recorded at different angles. We also recorded the measurement time of different surveyors. Results Compared to the front pointer measurement method, the OSMS method showed lower standard deviations. The reductions in standard deviations showed statistical significance in the Lat direction for the collimator rotation isocenter as well as in the Lat and Vrt directions for the gantry rotation isocenter. The mean deviation of Mag values for the collimator rotation isocenter using the OSMS method was 0.50 mm, which was larger than the 0.42 mm using the front pointer method. However, the standard deviation was 0.06 using the OSMS method, which was smaller than the 0.18 using the front pointer method. The mean deviation and standard deviation of Sag values for the gantry rotation isocenter using the OSMS method were 1.03 mm and 0.12, respectively, which were both larger than 0.47 mm and 0.06 using the front pointer method. For the couch rotation isocenter, the mean deviation and standard deviation using the OSMS method were 0.32 mm and 0.04, respectively, which were both smaller than the 0.55 mm and 0.20 using the front pointer method. All surveyors spent less time in isocenter measurements using the OSMS method compared to the front pointer method. Conclusion Compared with the front pointer method, the OSMS method significantly reduces the standard deviation among surveyors, effectively reduces the influence of the angle deviation of the accelerator on the measurement results, reduces detection time, improves detection efficiency, and provides a powerful practical basis for the application of OSMS in detecting the mechanical accuracy of the linear accelerator.
7.Rapid quality control method for automated organ-at-risk contouring in head and neck radiotherapy
Xiaoyu YANG ; Kaining YAO ; Yichen PU ; Shun ZHOU ; Ruoxi WANG ; Haizhen YUE ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):193-199
Objective To address the need for rapid review of automated organ-at-risk (OAR) contouring for head-and-neck cancer in online adaptive radiotherapy, this study used dosimetric indices as the reference standard to evaluate the suitability of geometric similarity metrics and to develop a rapid screening model that balances the risk of missed errors with review efficiency. Methods This retrospective study included 29 patients with head-and-neck radiotherapy, yielding 243 pairs of OAR contours (auto-generated vs. manual). Geometric similarity metrics, including the Dice similarity coefficient (Dice), the 95th percentile Hausdorff distance (HD95), and the maximum Hausdorff distance (HD100), were computed between the two contour sets. Using the dose distributions from clinical treatment plans, dosimetric differences between the two contour sets were calculated for key indices, including mean dose (Dmean) and maximum dose (Dmax). Correlations between geometric metrics and dosimetric differences were analyzed. Dosimetric discrepancy events were defined as Y3Gy using a threshold of 3 Gy. Within a univariable logistic regression triage framework, each geometric metric was used as an independent variable to estimate the probability of Y3Gy. Discriminative performance was assessed using receiver operating characteristic (ROC) curves and precision-recall (PR) curves, with the area under the curve (AUC) including ROC-AUC and PR-AUC. Practical operating thresholds were determined via threshold sweeping. Results Geometric similarity metrics showed weak-to-moderate correlations with dosimetric differences; compared with maximum dose, correlations with mean dose differences were more consistent. Among the evaluated metrics, HD95 achieved the best classification performance for Y3Gy. Threshold sweeping suggested that an HD95 threshold in the range of 4-9 mm can balance the risk of missed discrepancies with the efficiency of automated contour quality assurance (QA). Conclusion Several geometric similarity metrics demonstrated only weak-to-moderate associations with dosimetric differences. For head-and-neck OAR contour QA in this study, HD95 provided the best discriminative performance and can support rapid triage of automated contours, with a practical operating threshold range of 4-9 mm, potentially improving the efficiency of adaptive radiotherapy workflows.
8.A preliminary study on a method for detecting accelerator isocenter deviation using an optical surface monitoring system
Jianqi HU ; Shun ZHOU ; Jiangyan LUO ; Zihong LU ; Junyu LI ; Wen WANG ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):263-271
Objective To detect the isocenter of a medical linear accelerator using an optical surface monitoring system (OSMS) combined with a self-made 3D-printed phantom, and compare with the conventional front pointer measurement method. Methods A phantom that could be fixed to the front pointer of the accelerator was fabricated using 3D printing technology. The front pointer method and OSMS were used to detect the rotation isocenter deviations of the accelerator. During the experiments, the collimator, gantry, and couch linear displacement readings were recorded at different angles. We also recorded the measurement time of different surveyors. Results Compared to the front pointer measurement method, the OSMS method showed lower standard deviations. The reductions in standard deviations showed statistical significance in the Lat direction for the collimator rotation isocenter as well as in the Lat and Vrt directions for the gantry rotation isocenter. The mean deviation of Mag values for the collimator rotation isocenter using the OSMS method was 0.50 mm, which was larger than the 0.42 mm using the front pointer method. However, the standard deviation was 0.06 using the OSMS method, which was smaller than the 0.18 using the front pointer method. The mean deviation and standard deviation of Sag values for the gantry rotation isocenter using the OSMS method were 1.03 mm and 0.12, respectively, which were both larger than 0.47 mm and 0.06 using the front pointer method. For the couch rotation isocenter, the mean deviation and standard deviation using the OSMS method were 0.32 mm and 0.04, respectively, which were both smaller than the 0.55 mm and 0.20 using the front pointer method. All surveyors spent less time in isocenter measurements using the OSMS method compared to the front pointer method. Conclusion Compared with the front pointer method, the OSMS method significantly reduces the standard deviation among surveyors, effectively reduces the influence of the angle deviation of the accelerator on the measurement results, reduces detection time, improves detection efficiency, and provides a powerful practical basis for the application of OSMS in detecting the mechanical accuracy of the linear accelerator.
9.Study on the extraction process of Hongqijin granules based on standard decoction
Lingrui QIN ; Xutong WU ; Yicheng SUN ; Kaiping ZOU ; Liyuan TIAN ; Xiying TAN ; Jingxian XUE ; Chenguang ZHAO ; Shun LIU
China Pharmacy 2026;37(15):1954-1959
OBJECTIVE To study the extraction process of Hongqijin granules with the standard decoction of Hongqijin formula as the reference. METHODS Fifteen batches of Hongqijin formula standard decoction were prepared. The reference characteristic chromatogram was established, and the chromatographic similarity was calculated. The average extraction yield and average transfer rates of calycosin-7-glucoside, salidroside, curcumin, and emodin of the 15 batches of standard decoction were determined. Taking soaking time, water addition amount, and decoction time as influencing factors, and extraction yield, transfer rates of marker components, as well as chromatographic similarity with the reference characteristic chromatogram as evaluation indexes, orthogonal test combined with principal component analysis was adopted to optimize the extraction process of Hongqijin granules, followed by process verification. RESULTS The average extraction yield of 15 batches of Hongqijin formula standard decoction was 32.55%. The average transfer rates of calycosin-7-glucoside, salidroside, curcumin, and emodin were 70.68%, 74.35%, 2.16%, and 4.62%, respectively. The optimal extraction process of Hongqijin granules was confirmed as follows: extraction was carried out twice; the first extraction used 8-fold water for 60 min, and the second extraction adopted 6.5-fold water for 45 min. In three validation tests, the average extraction yield was 33.01%. The average transfer rates of the four marker components were 79.51%, 75.54%, 1.84%, and 4.30%, with all RSD values less than 2%. The chromatographic similarities between the extracting solution and reference characteristic chromatogram were all higher than 0.990. CONCLUSIONS The optimized extraction process of Hongqijin granules exhibits good stability, and the material basis of the extracting solution is consistent with that of Hongqijin formula standard decoction.
10.Early results and indications of Stand-alone oblique lateral interbody fusion in lumbar lesions.
Zhong-You ZENG ; Xing ZHAO ; Wei YU ; Yong-Xing SONG ; Shun-Wu FAN ; Xiang-Qian FANG ; Fei PEI ; Shi-Yang FAN ; Guo-Hao SONG
China Journal of Orthopaedics and Traumatology 2025;38(5):454-464
OBJECTIVE:
To summarize the early clinical results and safety of Stand-alone OLIF application of lumbar lesions, and explored its surgical indications.
METHODS:
Total of 92 cases of lumbar spine lesions treated with Stand-alone OLIF at two medical centers from October 2014 to December 2018 were retrospectively analyzed, including 30 males and 62 females with an average age of (61.20±12.94) years old ranged from 32 to 83 years old. There were 20 cases of lumbar spinal stenosis, 15 cases of lumbar disc degeneration, 11 cases of lumbar degenerative spondylolisthesis, 6 cases of discogenic low back pain, 7 cases of giant lumbar disc herniation, 13 cases of primary lumbar discitis, 6 cases of adjacent vertebral disease after lumbar internal fixation surgery, and 14 cases of degenerative lumbar scoliosis. Pre-operative dual energy X-ray bone density examination 31 cases' T-values ranged from -1 to -2.4, 8 cases' T-values ranged from -2.5 to -3.5, and the rest had normal bone density. The number of fusion segments: 68 cases of single segment, 9 cases of two segment, 12 cases of three segment , and 3 cases of four segment. Fusion site:L1,2 1 case, L2,3 4 cases, L3,4 10 cases, L4,5 53 cases, L2,3-L3,4 3 cases, L3,4-L4,5 6 cases, L1,2L2,3L3,4 1 case, L1,2L3,4L4,5 1 case, L2,3L3,4L4,5 10 cases, L1,2L2,3L3,4L4,5 3 cases. The clinical results and imaging results of this group of cases were observed, as well as the complications.
RESULTS:
The surgical time ranged from 40 to 140 minutes with an average of (60.92±27.40) minutes. The intraoperative bleeding volume was 20 to 720 ml with an average of (68.22±141.60) ml. The patients had a follow-up period of 6 to 84 months with an average of (38.50±12.75) months. The height of the intervertebral space recovered from (9.23±1.94) mm in preoperative to (12.68±2.01) mm in postoperative, and (9.11±1.72) mm at the last follow-up, there was a statistically significant difference(F=6.641, P=0.008);there was also a statistically significant difference between the postoperative and preoperative height of the intervertebral space(t=9.27, P<0.000 1);and there was also a statistically significant difference (t=10.06, P<0.000 1) between the last follow-up and postoperative height of the intervertebral space. At the last follow-up, cage subsidence grading was as follows:level 0 in 69 cases (76 segments), levelⅠin 17 cases (43 segments), level Ⅱin 5 cases (14 segments), and level Ⅲ in 1 case (1 segment);according to the number of segments, normal subsidence accounts for 56.72%, abnormal subsidence accounts for 43.28%. Bone mineral desity of normal subsidence groups was -0.50±0.07 whinch was better than that the abnormal subsidence groups -2.10±0.43, and the difference was statistically significant(χ2=2.275, P=0.014). As well as there was a statistically significant difference in the patient's VAS of backache from (6.28±2.11) in preoperative to (1.48±0.59) in last follow-up(t=8.56, P<0.05). The ODI recovered from (36.30±7.52)% before surgery to (10.20±2.50)% at the last follow-up, with a statistically significant difference (t=7.79, P<0.000 1). Complications involved 4 cases of intraoperative vascular injury, 21 cases of endplate injury, and 4 cases of combined vertebral fractures. The incision skin has no necrosis or infection. There were 4 cases of left sympathetic chain injury, 4 cases of transient left hip flexion weakness, 2 cases of left thigh anterolateral numbness with quadriceps femoris weakness, and 1 case of incomplete intestinal obstruction;8 cases were treated with posterior pedicle screw fixation due to fusion cage settlement accompanied by stubborn lower back pain, and 6 cases were treated with fusion cage settlement and lateral displacement. According to the actual number of cases, there were 38 complications, with an incidence rate of 41.3%.
CONCLUSION
The application of Stand alone OLIF in lumbar spine disease fusion has achieved good early results, with obvious clinical advantages, but also there are high probability of complications. It is recommended to choose carefully. It is necessary to continuously summarize and gradually clarify and complete the surgical indications and specific case selection criteria.
Humans
;
Male
;
Female
;
Middle Aged
;
Spinal Fusion/methods*
;
Lumbar Vertebrae/injuries*
;
Aged
;
Adult
;
Retrospective Studies
;
Aged, 80 and over