1.Impact of adverse childhood experiences and psychological symptoms on health risk behaviors among college students
Chinese Journal of School Health 2026;47(3):398-402
Objective:
To explore the impact of adverse childhood experiences (ACEs) on health risk behaviors (HRBs) among college students and the mediating role of psychological symptoms, so as to provide a basis for developing intervention strategies.
Methods:
From March to April 2023, a convenience cluster sample of 1 801 students from 12 universities in Nanning, Liuzhou, Guilin, Wuzhou of Guangxi completed an online survey. A self designed questionnaire, Adverse Childhood Experiences-International Questionnaire (ACE-IQ) and Symptom Checklist-90 (SCL-90) were used for evaluation tools. Binary Logistic regression, structural equation modeling (SEM) and Bootstrap methods were used to analyze the associations and mediating effects.
Results:
Overall, 71.2% of college students experienced at least one type of ACE, with emotional neglect (40.3%) and emotional abuse ( 25.2 %) having the highest detection rates. The top three HRBs were unhealthy diet (77.8%), physical inactivity (54.1%), and smoking/alcohol use (18.5%). Logistic regression showed that poor family functioning, abuse, and extra familial violence were each associated with an increased risk of smoking/alcohol use ( OR =1.14, 1.11, 1.18) and deliberate self harm ( OR =1.26, 1.19,1.30) (all P <0.05). Experience of abuse increased the risk of high risk sexual behavior and family dysfunction increaded the risk of physical inactivity, respectively ( OR = 1.07 , 1.04, both P <0.05). Mediation analysis revealed that anxiety ( β =0.20) and depression ( β = 0.09 ) partially mediated the pathway from poor family functioning to deliberate self harm; paranoia ( β =0.02) partially mediated the pathway from abuse to high risk sexual behavior; and obsessive-compulsive symptoms ( β =0.26) and depression ( β =0.10) partially mediated the pathway from extra familial violence to deliberate self harm (all P <0.05).
Conclusion
Psychological symptoms play a mediating role in the association between ACEs and HRBs, and mental health interventions may reduce the risk of HRBs among college students.
2.A preliminary study on a method for detecting accelerator isocenter deviation using an optical surface monitoring system
Jianqi HU ; Shun ZHOU ; Jiangyan LUO ; Zihong LU ; Junyu LI ; Wen WANG ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):263-271
Objective To detect the isocenter of a medical linear accelerator using an optical surface monitoring system (OSMS) combined with a self-made 3D-printed phantom, and compare with the conventional front pointer measurement method. Methods A phantom that could be fixed to the front pointer of the accelerator was fabricated using 3D printing technology. The front pointer method and OSMS were used to detect the rotation isocenter deviations of the accelerator. During the experiments, the collimator, gantry, and couch linear displacement readings were recorded at different angles. We also recorded the measurement time of different surveyors. Results Compared to the front pointer measurement method, the OSMS method showed lower standard deviations. The reductions in standard deviations showed statistical significance in the Lat direction for the collimator rotation isocenter as well as in the Lat and Vrt directions for the gantry rotation isocenter. The mean deviation of Mag values for the collimator rotation isocenter using the OSMS method was 0.50 mm, which was larger than the 0.42 mm using the front pointer method. However, the standard deviation was 0.06 using the OSMS method, which was smaller than the 0.18 using the front pointer method. The mean deviation and standard deviation of Sag values for the gantry rotation isocenter using the OSMS method were 1.03 mm and 0.12, respectively, which were both larger than 0.47 mm and 0.06 using the front pointer method. For the couch rotation isocenter, the mean deviation and standard deviation using the OSMS method were 0.32 mm and 0.04, respectively, which were both smaller than the 0.55 mm and 0.20 using the front pointer method. All surveyors spent less time in isocenter measurements using the OSMS method compared to the front pointer method. Conclusion Compared with the front pointer method, the OSMS method significantly reduces the standard deviation among surveyors, effectively reduces the influence of the angle deviation of the accelerator on the measurement results, reduces detection time, improves detection efficiency, and provides a powerful practical basis for the application of OSMS in detecting the mechanical accuracy of the linear accelerator.
3.A preliminary study on a method for detecting accelerator isocenter deviation using an optical surface monitoring system
Jianqi HU ; Shun ZHOU ; Jiangyan LUO ; Zihong LU ; Junyu LI ; Wen WANG ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):263-271
Objective To detect the isocenter of a medical linear accelerator using an optical surface monitoring system (OSMS) combined with a self-made 3D-printed phantom, and compare with the conventional front pointer measurement method. Methods A phantom that could be fixed to the front pointer of the accelerator was fabricated using 3D printing technology. The front pointer method and OSMS were used to detect the rotation isocenter deviations of the accelerator. During the experiments, the collimator, gantry, and couch linear displacement readings were recorded at different angles. We also recorded the measurement time of different surveyors. Results Compared to the front pointer measurement method, the OSMS method showed lower standard deviations. The reductions in standard deviations showed statistical significance in the Lat direction for the collimator rotation isocenter as well as in the Lat and Vrt directions for the gantry rotation isocenter. The mean deviation of Mag values for the collimator rotation isocenter using the OSMS method was 0.50 mm, which was larger than the 0.42 mm using the front pointer method. However, the standard deviation was 0.06 using the OSMS method, which was smaller than the 0.18 using the front pointer method. The mean deviation and standard deviation of Sag values for the gantry rotation isocenter using the OSMS method were 1.03 mm and 0.12, respectively, which were both larger than 0.47 mm and 0.06 using the front pointer method. For the couch rotation isocenter, the mean deviation and standard deviation using the OSMS method were 0.32 mm and 0.04, respectively, which were both smaller than the 0.55 mm and 0.20 using the front pointer method. All surveyors spent less time in isocenter measurements using the OSMS method compared to the front pointer method. Conclusion Compared with the front pointer method, the OSMS method significantly reduces the standard deviation among surveyors, effectively reduces the influence of the angle deviation of the accelerator on the measurement results, reduces detection time, improves detection efficiency, and provides a powerful practical basis for the application of OSMS in detecting the mechanical accuracy of the linear accelerator.
4.A preliminary study on a method for detecting accelerator isocenter deviation using an optical surface monitoring system
Jianqi HU ; Shun ZHOU ; Jiangyan LUO ; Zihong LU ; Junyu LI ; Wen WANG ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):263-271
Objective To detect the isocenter of a medical linear accelerator using an optical surface monitoring system (OSMS) combined with a self-made 3D-printed phantom, and compare with the conventional front pointer measurement method. Methods A phantom that could be fixed to the front pointer of the accelerator was fabricated using 3D printing technology. The front pointer method and OSMS were used to detect the rotation isocenter deviations of the accelerator. During the experiments, the collimator, gantry, and couch linear displacement readings were recorded at different angles. We also recorded the measurement time of different surveyors. Results Compared to the front pointer measurement method, the OSMS method showed lower standard deviations. The reductions in standard deviations showed statistical significance in the Lat direction for the collimator rotation isocenter as well as in the Lat and Vrt directions for the gantry rotation isocenter. The mean deviation of Mag values for the collimator rotation isocenter using the OSMS method was 0.50 mm, which was larger than the 0.42 mm using the front pointer method. However, the standard deviation was 0.06 using the OSMS method, which was smaller than the 0.18 using the front pointer method. The mean deviation and standard deviation of Sag values for the gantry rotation isocenter using the OSMS method were 1.03 mm and 0.12, respectively, which were both larger than 0.47 mm and 0.06 using the front pointer method. For the couch rotation isocenter, the mean deviation and standard deviation using the OSMS method were 0.32 mm and 0.04, respectively, which were both smaller than the 0.55 mm and 0.20 using the front pointer method. All surveyors spent less time in isocenter measurements using the OSMS method compared to the front pointer method. Conclusion Compared with the front pointer method, the OSMS method significantly reduces the standard deviation among surveyors, effectively reduces the influence of the angle deviation of the accelerator on the measurement results, reduces detection time, improves detection efficiency, and provides a powerful practical basis for the application of OSMS in detecting the mechanical accuracy of the linear accelerator.
5.Finite element analysis of impact of bone mass and volume in low-density zone beneath tibial plateau on cartilage and meniscus in knee joint.
Longfei HAN ; Wenyuan HOU ; Shun LU ; Zijun ZENG ; Kun LIN ; Mingli HAN ; Guifeng LUO ; Long TIAN ; Fan YANG ; Mincong HE ; Qiushi WEI
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(3):296-306
OBJECTIVE:
To investigate the impact of bone mass and volume of low-density zones beneath the tibial plateau on the maximum von Mises stresses experienced by the cartilage and meniscus in the knee joint.
METHODS:
The study included one healthy adult volunteer, from whom CT scans were obtained, and one patient diagnosed with knee osteoarthrisis (KOA), for whom X-ray films were acquired. A static model of the knee joint featuring a low-density zone was established based on a normal knee model. In the finite element analysis, axial loads of 1 000 N and 1 800 N were applied to the weight-bearing region of the upper surface of the femoral head for model validation and subsequent finite element studies, respectively. The maximum von Mises stresses in the femoral cartilage, as well as the medial and lateral tibial cartilage and menisci, were observed, and the stress percentage of the medial and lateral components were concurrently analyzed. Additionally, HE staining, as well as alkaline magenta staining, were performed on the pathological specimens of patients with KOA in various low-density regions.
RESULTS:
The results of model validation indicated that the model was consistent with normal anatomical structures and correlated with previous calculations documented in the literature. Static analysis revealed that the maximum von Mises stress in the medial component of the normal knee was the lowest and increased with the advancement of the hypointensity zone. In contrast, the lateral component exhibited an opposing trend, with the maximum von Mises stress in the lateral component being the highest and decreasing as the hypointensity zone progressed. Additionally, the medial component experienced an increasing proportion of stress within the overall knee joint. HE staining demonstrated that the chondrocyte layer progressively deteriorated and may even disappear as the hypointensity zone expanded. Furthermore, alkaline magenta staining indicated that the severity of microfractures in the trabecular bone increased concurrently with the expansion of the hypointensity zone.
CONCLUSION
The presence of subtalar plateau low-density zone may aggravate joint degeneration. In clinical practice, it is necessary to pay attention to the changes in the subtalar plateau low-density zone and actively take effective measures to strengthen the bone status of the subtalar plateau low-density zone and restore the complete biomechanical function of the knee joint, in order to slow down or reverse the progression of osteoarthritis.
Humans
;
Finite Element Analysis
;
Knee Joint/physiology*
;
Tibia/anatomy & histology*
;
Cartilage, Articular/physiology*
;
Menisci, Tibial/physiopathology*
;
Tomography, X-Ray Computed
;
Osteoarthritis, Knee/diagnostic imaging*
;
Weight-Bearing
;
Bone Density
;
Adult
;
Stress, Mechanical
;
Male
;
Middle Aged
;
Biomechanical Phenomena
;
Female
6.Systematic Optimization of Swelling-Enzymatic Extraction and Aqueous Two-Phase Purification for Phycocyanin
Jia-Rong LIN ; Shun-Yi WANG ; Fang LUO ; Cui-Ying LIN ; Zhen-Yu LIN
Chinese Journal of Analytical Chemistry 2025;53(9):1516-1525
An integrated extraction-purification process was established in this work for efficient phycocyanin production from dried Spirulina platensispowder.Initially,phycocyanin was extracted from algal biomass using a combined swelling-enzymatic lysis strategy.Single-factor experiments were carried out to systematically evaluate the effects of critical parameters,including system pH,enzymatic hydrolysis duration,and temperature,on phycocyanin extraction yield.Subsequently,a three-factor,three-level Box-Behnken response surface methodology design was employed to optimize the extraction process,with phycocyanin concentration and purity in the extract serving as response variables.A predictive regression model identified optimal conditions as follows:pH 6.4,hydrolysis time 3.2 h,and temperature 35.4℃.Experimental validation under these conditions yielded a phycocyanin recovery of 26.6%.Following extraction,purification was achieved via a polyethylene glycol-phosphate aqueous two-phase extraction system,which elevated the final purity to 4.21.Results demonstrated that the swelling-enzymatic lysis approach effectively disrupted algal cellular structures,significantly enhancing phycocyanin release efficiency.Concurrently,the aqueous two-phase system enabled selective partitioning and enrichment of the target protein under mild conditions.The integrated process exhibited high extraction efficiency,gentle purification,and robust operability,rendering it suitable for the scalable production of natural phycocyanin.This work provided both methodological foundations and technical support for advancing phycocyanin applications in natural pigments,biomedicine,and analytical detection.
7.Analysis of factors influencing the operation time and complications of endoscopic unilateral thyroidectomy by a gasless unilateral axillary approach
Wei WANG ; Juanzhang LUO ; Fuke WANG ; Shun QIU ; Xiaoxia LUO ; Xianhong FU ; Peihua LI ; Ruimei SUN
China Journal of Endoscopy 2025;31(9):29-39
Objective To explore the factors that may influence the operation time and complications of endoscopic unilateral thyroidectomy by a gasless unilateral axillary approach.Methods Clinical data of 203 consecutive patients who underwent endoscopic unilateral thyroidectomy by a gasless unilateral axillary approach from December 2022 to November 2023 were collected.Results Gender,BMI,TG,glandular lobe volume,number of lesions,and benign and malignant tumors affected the length of surgery;Among them,male,BMI>19.45 kg/m2 and glandular lobe volume>9.25 mL were independent influences on the length of surgery(P<0.05).TG and tumor maximal diameter affected the occurrence of complications;There was no independent influence factor.Conclusion Female patients with BMI≤19.45 kg/m2 and glandular lobe volume ≤ 9.25 mL(which can be measured preoperatively by 3D slicer)are relatively less difficult to perform the procedure and may be more suitable for beginners to learn.
8.Analysis of factors influencing the operation time and complications of endoscopic unilateral thyroidectomy by a gasless unilateral axillary approach
Wei WANG ; Juanzhang LUO ; Fuke WANG ; Shun QIU ; Xiaoxia LUO ; Xianhong FU ; Peihua LI ; Ruimei SUN
China Journal of Endoscopy 2025;31(9):29-39
Objective To explore the factors that may influence the operation time and complications of endoscopic unilateral thyroidectomy by a gasless unilateral axillary approach.Methods Clinical data of 203 consecutive patients who underwent endoscopic unilateral thyroidectomy by a gasless unilateral axillary approach from December 2022 to November 2023 were collected.Results Gender,BMI,TG,glandular lobe volume,number of lesions,and benign and malignant tumors affected the length of surgery;Among them,male,BMI>19.45 kg/m2 and glandular lobe volume>9.25 mL were independent influences on the length of surgery(P<0.05).TG and tumor maximal diameter affected the occurrence of complications;There was no independent influence factor.Conclusion Female patients with BMI≤19.45 kg/m2 and glandular lobe volume ≤ 9.25 mL(which can be measured preoperatively by 3D slicer)are relatively less difficult to perform the procedure and may be more suitable for beginners to learn.
9.Clinical trial of parecoxib sodium combined with dexmedetomidine for surgery in patients with osteoporotic compression fractures
Kai LUO ; Qing WANG ; Gao-Ju WANG ; Jin YANG ; Guang-Zhou LI ; Shi-Jie SONG ; Shun-Gui CAI
The Chinese Journal of Clinical Pharmacology 2024;40(20):2963-2967
Objective To investigate the effects of parecoxib sodium injection combined with dexmedetomidine hydrochloride injection on postoperative cognitive function and stress response in patients with osteoporotic compression fractures.Methods The patients with osteoporotic compression fractures were divided into treatment group and control group according to the treatment plan.The control group was given intravenous injection of dexmedetomidine hydrochloride injection 0.2 μg·kg-1load dose,then micro pump injection 0.2 μg·kg-1·min-1 maintenance dose,until 30 min before the end of the operation;patients in the treatment group were intravenously injected with parecoxib sodium injection 20 mg before local anesthesia and 30 min before the end of operation on the basis of the control group.The pain,sedation,hemodynamics[mean arterial pressure(MAP),heart rate(HR)],cognitive function and safety evaluation were compared between the two groups before operation(T0),2 h after operation(T1),6 h after operation(T2),12 h after operation(T3)and 24 h after operation(T4).Results There were 39 cases in the treatment group and 41 cases in the control group.Visual analogue scale(VAS)scores in treatment group and control group were(3.09±0.55)and(3.41±0.62)scores at T1;VAS scores were(3.02±0.57)and(3.35±0.48)scores at T2;VAS scores were(2.64±0.44)and(2.90±0.46)scores at T3;VAS scores were(2.02±0.41)and(2.35±0.47)scores at T4;MMSE scores were(25.28±1.57)and(24.33±1.42)scores at T2;MMSE scores were(28.16±1.01)and(27.25±0.89)scores at T4;MoCA scores were(24.63±1.60)and(23.59±1.25)scores at T2;MoCA scores were(27.20±0.97)and(26.48±0.83)scores at T4.There were statistically significant differences in the above indexes between the treatment group and the control group(all P<0.05).Adverse drug reactions in the treatment group included bradycardia,hypotension,nausea vomiting and hypokalemia;adverse drug reactions in the control group included bradycardia,hypotension and nausea vomiting.The total incidence rates of adverse drug reactions were 12.82%and 9.76%,without statistically significant difference(P>0.05).Conclusion Compared with using dexmedetomidine alone,parecoxib sodium combined with dexmedetomidine is beneficial for relieving postoperative pain in patients with osteoporotic compression fractures,improving postoperative cognitive function.
10.Diagnostic value of CT plain scan for isolated superior mesenteric artery dissection
Shun QIU ; Yueqi HUANG ; Guanghua LUO ; Qiulin HUANG ; Qingchun LI
Journal of Practical Radiology 2024;40(6):922-925,930
Objective To investigate the diagnostic value of CT plain scanning for isolated superior mesenteric artery dissection(ISMAD).Methods This study retrospectively investigated CT plain images of the superior mesenteric artery(SMA)in 45 patients with ISM AD and 45 patients without ISMAD.The imaging manifestations of ISMAD were analyzed,and the sensitivity and specificity of these manifestations were analyzed using receiver operating characteristic(ROC)curve.Results There were statistically significant differences in both the trunk diameter and standardized trunk diameter of the SMA between the two groups(P<0.001,P=0.001).Additionally,the area under the curve(AUC)for the SMA trunk diameter in diagnosing ISMAD was determined to be 0.988,with a statistically significant P-value of less than 0.001.Furthermore,when the diameter of the SMA trunk reached 8.20 mm,the diagnostic sensitivity was 97.8%and the specificity was 93.3%.The AUC for the standardized diameter of the SMA trunk was determined to be 0.976.Additionally,when the standardized diameter of the SMA trunk reached 70.33%,the diagnostic sensitivity was 95.6%and the specificity was 82.2%.There was no statistically significant difference observed in the luminal CT value and standardized CT value of the SMA between the two groups(P>0.05).Additionally,the presence of the"crescent sign"and peritubular fat blurring in the SMA demonstrated some level of diagnostic significance.Conclusion CT scanning has the capability to identify the enlarged diameter of the SMA trunk,as well as plain the"crescent sign"and related manifestations.This finding holds significant value in diagnosing ISMAD.Furthermore,it provides the basis for the necessity of subsequent computed tomography angiography(CTA)examinations.


Result Analysis
Print
Save
E-mail