1.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
2.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
3.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
4.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
5.Ultrasonic follow-up observation on size changes of 4C type thyroid micronodule classified by C-TIRADS
Guangxiang YANG ; Weihong SHEN ; Hong GUO ; Shuhong LIU ; Dan LIU
Chinese Journal of Health Management 2023;17(1):47-51
Objective:To observe the size changes under ultrasound of 4C type thyroid micronodules classified by 2020 Chinese Thyroid Imaging Reporting and Data System (C-TIRADS)during follow-up.Methods:In this cross-sectional study, the data of thyroid ultrasonography in physical examination center in the Affiliated Zhongshan Hospital of Dalian University between December 2017 and December 2021 were retrospectively included, thyroid nodules were classified according to C-TIRADS, to observe the changes by ultrasound of maximum diameter and volume of 4C type thyroid micronodules during follow-up.Results:A total of 102 subjects receiving physical examinations with 103 thyroid micronodules were enrolled in this study. The maximum diameter and volume of thyroid micronodules at initial examination was 5.0 (4.0, 7.0) mm and 52.5 (25.2, 113.4) mm 3 respectively, and it was 6.0 (4.0,7.0) mm、65.6 (25.2,147.0) mm 3 at the last examination, respectively. Of the thyroid micronodules, 79 (76.7%) remained stable, 14 (13.6%) magnified and 10 (9.7%) shrunk during the follow-up. The cervical lymph nodes in all physical examiners were normal. There were significant changes in the maximum diameter and volume in the thyroid micronodules between the initial and last examination in subjects whose micronodules shrunk or magnified during the follow-up (all P<0.05). Conclusion:Size of most C-TIRADS 4C thyroid micronodules remains stable or even decreases during ultrasound follow-up observation, for such thyroid nodules, follow-up observation appears to be a safe and feasible way to postpone surgery.
6.Venous thromboembolism in children with acute lymphoblastic leukemia in China: a report from the Chinese Children's Cancer Group-ALL-2015.
Mengmeng YIN ; Hongsheng WANG ; Xianmin GUAN ; Ju GAO ; Minghua YANG ; Ningling WANG ; Tianfeng LIU ; Jingyan TANG ; Alex W K LEUNG ; Fen ZHOU ; Xuedong WU ; Jie HUANG ; Hong LI ; Shaoyan HU ; Xin TIAN ; Hua JIANG ; Jiaoyang CAI ; Xiaowen ZHAI ; Shuhong SHEN ; Qun HU
Frontiers of Medicine 2023;17(3):518-526
Venous thromboembolism (VTE) is a complication in children with acute lymphoblastic leukemia (ALL). The Chinese Children's Cancer Group-ALL-2015 protocol was carried out in China, and epidemiology, clinical characteristics, and risk factors associated with VTE were analyzed. We collected data on VTE in a multi-institutional clinical study of 7640 patients with ALL diagnosed in 20 hospitals from January 2015 to December 2019. First, VTE occurred in 159 (2.08%) patients, including 90 (56.6%) during induction therapy and 108 (67.92%) in the upper extremities. T-ALL had a 1.74-fold increased risk of VTE (95% CI 1.08-2.8, P = 0.022). Septicemia, as an adverse event of ALL treatment, can significantly promote the occurrence of VTE (P < 0.001). Catheter-related thrombosis (CRT) accounted for 75.47% (n = 120); and, symptomatic VTE, 58.49% (n = 93), which was more common in patients aged 12-18 years (P = 0.023), non-CRT patients (P < 0.001), or patients with cerebral thrombosis (P < 0.001). Of the patients with VTE treated with anticoagulation therapy (n = 147), 4.08% (n = 6) had bleeding. The VTE recurrence rate was 5.03% (n = 8). Patients with VTE treated by non-ultrasound-guided venous cannulation (P = 0.02), with residual thrombus (P = 0.006), or with short anticoagulation period (P = 0.026) had high recurrence rates. Thus, preventing repeated venous puncture and appropriately prolonged anticoagulation time can reduce the risk of VTE recurrence.
Humans
;
Child
;
Venous Thromboembolism/etiology*
;
East Asian People
;
Precursor Cell Lymphoblastic Leukemia-Lymphoma/epidemiology*
;
Risk Factors
;
Thrombosis/chemically induced*
;
China/epidemiology*
;
Anticoagulants/adverse effects*
;
Recurrence
7.Exosomes derived from 3D-cultured MSCs improve therapeutic effects in periodontitis and experimental colitis and restore the Th17 cell/Treg balance in inflamed periodontium.
Yong ZHANG ; Jiayao CHEN ; Haijun FU ; Shuhong KUANG ; Feng HE ; Min ZHANG ; Zongshan SHEN ; Wei QIN ; Zhengmei LIN ; Shuheng HUANG
International Journal of Oral Science 2021;13(1):43-43
Although mesenchymal stem cell-derived exosomes (MSC-exos) have been shown to have therapeutic effects in experimental periodontitis, their drawbacks, such as low yield and limited efficacy, have hampered their clinical application. These drawbacks can be largely reduced by replacing the traditional 2D culture system with a 3D system. However, the potential function of MSC-exos produced by 3D culture (3D-exos) in periodontitis remains elusive. This study showed that compared with MSC-exos generated via 2D culture (2D-exos), 3D-exos showed enhanced anti-inflammatory effects in a ligature-induced model of periodontitis by restoring the reactive T helper 17 (Th17) cell/Treg balance in inflamed periodontal tissues. Mechanistically, 3D-exos exhibited greater enrichment of miR-1246, which can suppress the expression of Nfat5, a key factor that mediates Th17 cell polarization in a sequence-dependent manner. Furthermore, we found that recovery of the Th17 cell/Treg balance in the inflamed periodontium by the local injection of 3D-exos attenuated experimental colitis. Our study not only showed that by restoring the Th17 cell/Treg balance through the miR-1246/Nfat5 axis, the 3D culture system improved the function of MSC-exos in the treatment of periodontitis, but also it provided a basis for treating inflammatory bowel disease (IBD) by restoring immune responses in the inflamed periodontium.
Colitis
;
Exosomes
;
Humans
;
Periodontitis/therapy*
;
Periodontium
;
T-Lymphocytes, Regulatory
;
Th17 Cells
8.Progress on asparaginase-associated pancreatitis
International Journal of Pediatrics 2020;47(3):180-183
Acute lymphoblastic leukemia(ALL)is the most common childhood malignancy.As an essential component of multiagent chemotherapy, asparaginase(ASP)has significantly improved the remission rate and event-free survival rate of children with ALL since its application in clinical practice.However, there are many adverse events due to ASP, including asparaginase-associated pancreatitis(AAP). The mechanisms behind and the risk factors predisposing AAP are unknown.This review summarizes the latest research progresses on AAP.
9.Homoharringtonine is a safe and effective substitute for anthracyclines in children younger than 2 years old with acute myeloid leukemia.
Xiaoxiao CHEN ; Yanjing TANG ; Jing CHEN ; Ru CHEN ; Longjun GU ; Huiliang XUE ; Ci PAN ; Jingyan TANG ; Shuhong SHEN
Frontiers of Medicine 2019;13(3):378-387
Homoharringtonine (HHT), a plant alkaloid from Cephalotaxus harringtonia, exhibits a unique anticancer mechanism and has been widely used in China to treat patients with acute myeloid leukemia (AML) since the 1970s. Trial SCMC-AML-2009 presented herein was a randomized clinical study designed based on our previous findings that pediatric AML patients younger than two years old may benefit from HHT-containing chemotherapy regimens. Patients randomized to arm A were treated with a standard chemotherapy regimen comprising mainly of anthracyclines and cytarabine (Ara-C), whereas patients in arm B were treated with HHT-containing regimens in which anthracyclines in all but the initial induction therapy were replaced by HHT. From February 2009 to November 2015, 59 patients less than 2 years old with de novo AML (other than acute promyelocytic leukemia) were recruited. A total of 42 patients achieved a morphologic complete remission (CR) after the first course, with similar rates in both arms (70.6% vs.72.0%). At the end of the follow-up period, 40 patients remained in CR and 5 patients underwent hematopoietic stem cell transplantation in CR, which could not be considered as events but censors. The 5-year event-free survival (EFS) was 60.2%±9.6% for arm A and 88.0%±6.5% for arm B (P= 0.024). Patients in arm B experienced shorter durations of leukopenia, neutropenia, and thrombocytopenia and had a lower risk of infection during consolidation chemotherapy with high-dosage Ara-C. Consequently, the homoharringtonine-based regimen achieved excellent EFS and alleviated hematologic toxicity for children aged younger than 2 years with de novo AML compared with the anthracycline-based regimen.
10.The establishment of Nomogram prognostic model for patients with non-metastasis renal cell carcinoma after the operation
Hongliang SHEN ; Xudong WANG ; Mingyi LI ; Ning WANG ; Yong AN ; Zhengguo JI ; Shufang SHI ; Shuhong ZHANG ; Peiqian YANG ; Ye TIAN
Chinese Journal of Urology 2018;39(4):245-250
Objective To investigate the prognostic factors of renal cell carcinoma and to establish a prognostic model for patients with non-metastasis renal cell carcinoma (RCC) after operation.Methods We retrospectively reviewed the clinical data of patients with RCC who underwent radical or partial nephrectomy from January 2008 to December 2012,including 392 males (67.6%) and 188 females (32.4%),with an average age of 56 years(range 24-86 years).The average diameter of tumor was 4.8 cm (range 1.5-17.5 cm).The pathological slides of tumor tissue were reviewed by pathologist,and the tissue microarray (TMA) were constructed.The immunohistochemical staining of TMA were carried out.All patients were followed up the prognosis information of the overall survival (OS),cancer specific survival (CSS) and progression free survival (PFS).Based on these data,univariate and multivariate analysis and survival analysis were performed.Independent prognostic factors related to different follow-up endpoints of patients were screened out.A Nomogram prognostic model for RCC was established and verified.Internal validation were performed by boots value analysis.Results Among 580 cases,160 cases (27.6%) accepted nephron sparing surgery and 420 cases (72.4%) radical nephrectomy,included 514 cases (88.6%) of laparoscopic surgery and 66 cases (11.4%) of open surgery.There were 468 cases of clear cell carcinoma (80.7%),56 cases of papillary carcinoma (9.7%),32 cases of chromophobe cell carcinoma (5.5%),24 patients with other subtypes of cancer cells (4.1%).In pathological staging,stage Ⅰ,Ⅱ,Ⅲ,Ⅳ were 442 cases (76.2%),88 cases (15.2%),48 cases (8.3%),2 cases (0.3%),respectively.There were 424 cases (73.1%) with high expression of CA9,and 156 cases (26.9%) with low expression.The median followup was 66 (4-82) months,and 41 cases (7.1%) were lost of follow-up.For 3 and 5 years,OS,CSS and PFS were 83.4%,88.2%,72.4% and 69.6%,73.0%,55.8% respectively.Multivariate analysis showed that tumor pathological subtypes,tumor stage,tumor diameter and positive expression of carbonic anhydrase 9 (CA9) were independent prognostic factors associated with the survival of RCC patients.The Nomogram prognostic model was established by the above four factors.The established Nomogram prognostic model for RCC patients was verified by Harrell's consistency index,and the c-index of OS,CSS and PFS of RCC patients were 0.72 (95% CI 0.69-0.75),0.77 (95% CI 0.74-0.81),0.79 (95% CI 0.76-0.83),respectively.Conclusions Tumor pathological subtypes,staging,tumor diameter and CA9 are independent risk factors for patients with non metastatic renal cell carcinoma.The established Nomogram prognostic model certified by internal validation should be tested by large samples and multicenter studies need tested.

Result Analysis
Print
Save
E-mail