1.Expert consensus on clinical application of parenteral direct thrombin inhibitors in perioperative period
Mingyu JIANG ; Yuan BIAN ; Lizhu HAN ; Qinan YIN ; Fengjiao KANG ; Anhua WEI ; Danjie ZHAO ; Lin WANG ; Ying SHAO ; Li TANG ; Yi WANG ; Shuhong LIANG ; Huijuan LIU ; Guirong XIAO ; Yue LI
China Pharmacy 2026;37(6):689-699
OBJECTIVE To form an expert consensus on the clinical application of parenteral direct thrombin inhibitors (DTIs) in patients during the perioperative period. METHODS Led by Sichuan Academy of Medical Sciences & Sichuan Provincial People’s Hospital (the Affiliated Hospital of UESTC), a multidisciplinary working group was established. Through literature review and the Delphi method, clinical questions related to the rational perioperative use of parenteral DTIs were identified. A structured design was adopted using the “Population-Intervention-Comparison-Outcome” framework; systematic searches were conducted in CNKI, Medline, Embase and other databases. Relevant evidence from randomized controlled trials and cohort studies was included and synthesized. Evidence quality was assessed using the Grades of Recommendations Assessment,Development and Evaluation (GRADE) approach, and recommendations were formulated through multiple rounds of Delphi surveys and expert consensus meetings. RESULTS &CONCLUSIONS Seven recommendations (each with an expert consensus rate exceeding 90%) on the use of parenteral DTIs in perioperative patients were developed. These recommendations specify drug selection, dosing ranges, key monitoring points, and safety management strategies for parenteral DTIs in various scenarios, including the perioperative period of ventricular assist device implantation, the perioperative period of cardiac surgery, perioperative patients with lower-extremity atherosclerotic disease, the perioperative period of percutaneous coronary intervention in patients with acute coronary syndrome, the perioperative period of carotid artery stenting in patients with carotid stenosis, the perioperative period of patients with right heart thrombosis, and patients who develop related thrombosis and dysfunction after a central venous catheter insertion. In addition, warning and management pathways for perioperative bleeding and thrombotic events were proposed. This expert consensus, which is formulated based on the best available evidence, provides evidence-based guidance for standardized and individualized use of parenteral DTIs in perioperative period.
2.A novel loop-structure-based bispecific CAR that targets CD19 and CD22 with enhanced therapeutic efficacy against B-cell malignancies.
Lijun ZHAO ; Shuhong LI ; Xiaoyi WEI ; Xuexiu QI ; Qiaoru GUO ; Licai SHI ; Ji-Shuai ZHANG ; Jun LI ; Ze-Lin LIU ; Zhi GUO ; Hongyu ZHANG ; Jia FENG ; Yuanyuan SHI ; Suping ZHANG ; Yu J CAO
Protein & Cell 2025;16(3):227-231
3.Ferroptosis: a potential new therapeutic target for myocardial injury induced by acute carbon monoxide poisoning.
Anping LIU ; Xuheng JIANG ; Tianjing SUN ; Mo LI ; Haizhen DUAN ; Shuhong WANG ; Anyong YU
Chinese Critical Care Medicine 2025;37(4):407-412
Acute carbon monoxide poisoning (ACMP) is one of the most common gas poisonings in the emergency department, with tens of thousands of people seeking medical attention for carbon monoxide (CO) poisoning each year. The severity of poisoning is dependent upon environmental and human factors, with hypoxia and oxidative stress being important mechanisms of cardiac toxicity induced by CO. Myocardial involvement is common in moderate to severe ACMP, including myocardial injury, myocardial infarction, arrhythmia, and sudden death, which are associated with a high risk of death. Ferroptosis is a cell death mechanism caused by iron-dependent lipid peroxidation (LPO), although ferroptosis has been shown to play a critical role in various cardiovascular diseases, the potential mechanism by which it contributes to ACMP-induced myocardial injury is unclear. This review discusses the established link between ferroptosis and cardiovascular disease and summarizes the potential role of ferroptosis in ACMP-induced myocardial injury and the detrimental effects of ACMP on the heart. Elucidating these mechanisms could guide the development of novel therapeutic strategies that target ferroptosis to mitigate ACMP-induced myocardial injury. This review aims to provide a theoretical foundation for future research on the potential use of ferroptosis as a therapeutic target for ACMP-induced myocardial injury.
Humans
;
Carbon Monoxide Poisoning/complications*
;
Ferroptosis
;
Lipid Peroxidation
;
Myocardium/pathology*
;
Oxidative Stress
4.Research on optimizing postoperative rehabilitation of cataract patients through nursing pathway driven by theory of planned behavior
Zhenping CHEN ; Shuhong HUANG ; Longfei LI
Journal of Clinical Medicine in Practice 2025;29(17):116-119,125
Objective To explore the optimization effect of the nursing pathway driven by the theory of planned behavior(TPB)on postoperative rehabilitation in patients with senile cataract.Methods A total of 100 patients with senile cataract were selected as the research subjects and ran-domly divided into control group and study group using the random number table method,with 50 ca-ses in each group.The control group received routine nursing care,while the study group received TPB-driven nursing pathway intervention in addition to routine care.The postoperative recovery sta-tus,hospitalization expenses,visual quality[Visual Function Index Questionnaire(VF-14)score],self-care ability[Exercise of Self-care Agency Scale(ESC A)score],postoperative complications,and behavioral change intention were compared between the two groups.Results The postoperative visual acuity in the study group was higher,while the intraocular pressure and hospitalization expen-ses were lower than that in the control group.The visual acuity recovery time and hospitalization dura-tion were shorter in the study group than those in the control group,with statistically significant differ-ences(P<0.05).After the intervention,the VF-14 score and ESC A score in the study group were higher than those in the control group;the overall incidence of postoperative complications in the study group was 4.00%,which was lower than 16.00%in the control group;the scores of each di-mension of behavioral change intention after the intervention in the study group were higher than those in the control group,with statistically significant differences(P<0.05).Conclusion The TPB-driv-en nursing pathway can effectively optimize the postoperative rehabilitation effect in patients with senile cataract,improve their postoperative visual acuity,visual quality,and self-care ability,thereby enhancing the quality of rehabilitation.
5.Preparation of anti-influenza virus nanobodies and their applications in nanobody-ELISA
Fei WANG ; Yuchang LI ; Sen ZHANG ; Yuehong CHEN ; Tao JIANG ; Shuhong MAO ; Xiaoping KANG
Military Medical Sciences 2025;49(3):161-170
Objective To develop nanobodies with broad-spectrum reactivity,specificity,and high sensitivity that can be used for detecting multiple subtypes of influenza A virus,and to establish a nanobody-based enzyme-linked immunosorbent assay(ELISA)method.Methods Gene sequences of twelve nanobodies against influenza A virus were retrieved from the National Center for Biotechnology Information(NCBI)and nanobody databases.The nanoantibodies were prepared using molecular biological techniques including gene synthesis and recombinant expression.The binding activity,specificity,sensitivity,and affinity of these nanobodies were determined by ELISA screening and Gator affinity analysis.A double-antibody sandwich ELISA assay was established by combining the selected nanobody with a traditional mouse monoclonal antibody.Results Twelve nanobodies were expressed and purified.Two nanobodies capable of binding to multiple subtypes of influenza virus including H1,H3,H5,H7,and H9 were obtained and designated as VHH54 and KV108.Both nanobodies showed no cross-reactivity with other respiratory virus antigens.Furthermore,the KV108 nanobody exhibited the highest binding affinity,with a dissociation constant of 5.94×10-9mol/L for the influenza virus nucleoprotein(NP),and the lowest detection concentration for the NP antigen reached 0.00064 μg/mL.The double-antibody sandwich ELISA,using a combination of KV108 and a mouse monoclonal antibody,could sensitively detect the five common subtypes of influenza A virus(H1N1,H3N2,H5N1,H7N9,and H9N2).The lowest detection limit reached 110-403 PFU/mL,which was higher than that of the commercial colloidal gold kitfor influenza virus detection.Conclusion This study has identified a nanobody KV108,which is capable of binding to multiple subtypes of influenza virus,and established a nanobody-based ELISA method that can detect multiple subtypes of influenza A virus.This study can facilitate the development of nanobody-based influenza detection technologies.
6.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
7.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
8.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
9.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
10.Comparison of predictive value among three kinds of immuno-nutrition scoring tools for risk of severe stroke complicating lung infection
Shuhong ZHOU ; Jiajia YANG ; Junzhuo LI ; Guangwei LIU
Chongqing Medicine 2024;53(17):2608-2613
Objective To compare the predictive value of controlling nutritional status score(CO-NUT),prognostic nutritional index(PNI)and prognostic inflammation and nutritional index(PINI)for se-vere stroke complicating lung infection(SCLI),and to analyze the risk factors for severe SCLI occurrence.Methods A retrospective analysis on the clinical data of 98 cases of severe stroke firstly visited and treated in the nervous intensive care unit(NICU)of this hospital from August 2022 to August 2023 was performed.The patients were divided into the SCLI group and non-SCLI group according to whether or not SCLI occurring during the hospitalization.Logistic regression was used to analyze the independent risk factors influencing se-vere SCLI.The sensitivity,specificity,Youden index and Kappa value of the three tools in predicting severe SCLI were calculated,and the area under the receiver operating characteristic(ROC)curve(AUC)was plot-ted.Results Among 98 cases,there were 35 cases(35.71%)of SCLI occurrence during hospitalization.The multivariate logistic regression analysis results showed that the mechanical ventilation use(OR=1.33,95%CI:1.06-2.76),nasogastric tube use(OR=1.42,95%CI:1.25-2.68),high CONUT(OR=2.74),95%CI:2.02-3.69),low PNI(OR=0.70,95%CI:0.51-0.96)and low PINI(OR=2.51,95%CI:1.78-3.62)were the independent risk factors for severe SCLI(P<0.05).AUC of the ROC curve of CONUT,PNI and PINI for predicting SCLI was 0.729,0.723 and 0.697 respectively.The sensitivity was 0.707,0.685 and 0.631,and the specificity was 0.872,0.764 and 0.712,respectively.The Youden index was 0.579,0.449 and 0.343 respectively,and the Kappa value was 0.621,0.534 and 0.432 respectively.Conclusion CONUT,PNI and PINI all are correlated with the SCLI risk.CONUT has the highest predictive value for SCLI.

Result Analysis
Print
Save
E-mail