1.Concept, design and clinical application of minimally invasive liver transplantation through laparoscopic combined upper midline incision
Shuhong YI ; Hui TANG ; Kaining ZENG ; Xiao FENG ; Binsheng FU ; Qing YANG ; Jia YAO ; Yang YANG ; Guihua CHEN
Organ Transplantation 2025;16(1):67-73
Objective To explore the technical process and clinical application of laparoscopic combined upper midline incision minimally invasive liver transplantation. Methods A retrospective analysis was conducted on 30 cases of laparoscopic combined upper midline incision minimally invasive liver transplantation. The cases were divided into cirrhosis group (15 cases) and liver failure group (15 cases) based on the primary disease. The surgical and postoperative conditions of the two groups were compared. Results All patients successfully underwent laparoscopic "clockwise" liver resection, with no cases of passive conversion to open surgery or intolerance to pneumoperitoneum. In 6 cases, the right lobe was relatively large, and the right hepatic ligaments could not be completely mobilized. One case required an additional reverse "L" incision during open surgery. All patients successfully completed the liver transplantation, with no major intraoperative bleeding, cardiovascular events, or other occurrences in the 30 patients. The model for end-stage liver disease (MELD) score in the cirrhosis group was lower than that in the liver failure group (P<0.001). There were no statistically significant differences between the two groups in terms of age, surgical time, blood loss, anhepatic phase, or cold ischemia time (all P>0.05). During the perioperative period, there was 1 case of hepatic artery embolism, 1 case of portal vein anastomotic stenosis, no complications of hepatic vein and inferior vena cava, and 3 cases of biliary anastomotic stenosis, all of which occurred in the liver failure group. Conclusions In strictly selected cases, the minimally invasive liver transplantation technique combining laparoscopic hepatectomy with upper midline incision for graft implantation has the advantages of smaller incisions, less bleeding, relatively easier operation, and faster postoperative recovery, which is worthy of clinical promotion and application.
2.Short-term effectiveness of transtibial pull-out technique for complete radial tear of lateral meniscus body.
Hehe ZHONG ; Pengpeng SUN ; Jing CHEN ; Haohao YAO ; Huazhang XIONG ; Shuhong WU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(4):446-450
OBJECTIVE:
To investigate the short-term effectiveness of transtibial pull-out technique combined with side-to-side suture technique in treatment of complete radial tear of lateral meniscus body.
METHODS:
Between May 2020 and August 2023, 15 patients with complete radial tear of lateral meniscus body were repaired by arthroscopic transtibial pull-out technique combined with side-to-side suture technique. There were 11 males and 4 females, with an average age of 25.2 years (range, 15-43 years). Twelve cases were acute injuries and 3 were chronic injuries. All patients had tenderness in the lateral compartment of the knee. No abnormal alignment was observed on the X-ray films of the knee. MRI showed the complete radial tear of lateral meniscus body without associated injuries such as anterior cruciate ligament or cartilage. Preoperative Lysholm score was 44.5±6.4, International Knee Documentation Committee (IKDC) subjective score was 40.2±8.4, Tegner score was 1.3±1.1, and visual analogue scale (VAS) score for pain was 5.1±1.1. The operation time, incision healing, and complications such as vascular/nerve injury were recorded. During follow-up, the range of motion of the knee and tenderness in the lateral compartment of the knee were observed. The knee function and pain were evaluated using Lysholm score, Tegner score, IKDC subjective score, and VAS score. X-ray films and MRI of the knee were reexamined to assess knee degeneration.
RESULTS:
The operation time was 60-145 minutes (mean, 89.6 minutes). All incisions healed by first intention, and no complication such as vascular/nerve injury occurred. All patients were followed up 17-56 months (mean, 38.4 months). All patients had no knee extension limitation and 3 cases had tenderness in the lateral compartment of the knee. At last follow-up, the Lysholm score, IKDC subjective score, Tegner score, and VAS score for pain were 85.3±7.8, 82.1±15.7, 4.7±1.2, and 1.5±1.0, respectively, which were superior to those before operation ( P<0.05). Imaging reexamination showed that the meniscus was reset at 1 day after operation, and there was no sign of knee degeneration at last follow-up.
CONCLUSION
Transtibial pull-out technique combined with side-to-side suture technique can effectively treat the complete radial tear of lateral meniscus body and obtain good short-term effectiveness.
Humans
;
Male
;
Female
;
Adult
;
Tibial Meniscus Injuries/surgery*
;
Adolescent
;
Young Adult
;
Arthroscopy/methods*
;
Treatment Outcome
;
Suture Techniques
;
Tibia/surgery*
;
Menisci, Tibial/surgery*
;
Magnetic Resonance Imaging
3.Short-term effectiveness of edge-to-edge #-shaped suture for complete radial tear of lateral meniscus body.
Hehe ZHONG ; Jing CHEN ; Pengpeng SUN ; Dongfeng CAI ; Lidan YANG ; Huazhang XIONG ; Shuhong WU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(9):1165-1169
OBJECTIVE:
To investigate the surgical method and short-term effectiveness of arthroscopy edge-to-edge #-shaped suture in the treatment of the complete radial tear of the lateral meniscus body.
METHODS:
The clinical data of 13 patients with complete radial tear of lateral meniscus body between May 2020 and August 2023 were retrospectively analyzed. There were 10 males and 3 females, aged 15-38 years (mean, 24.2 years). There were 11 cases of acute injury and 2 cases of chronic injury, with time from injury to admission ranging from 2 days to 5 months. All patients had tenderness in the lateral joint space, and 2 patients with chronic injury had positive McMurray's sign. All patients were treated with arthroscopic edge-to-edge #-shaped suture technique. The knee joint activity and tenderness in the lateral joint space were detected, and the healing of the incision and the occurrence of complications were observed. X-ray films and MRI of the knee joint were performed to evaluate joint degeneration and meniscus healing. Lysholm score, International Knee Documentation Committee (IKDC) subjective score, Tegner score, and visual analogue scale (VAS) score were used to evaluate the functional recovery before and after operation.
RESULTS:
The operation time ranged from 46 to 100 minutes (mean, 80.08 minutes). All the incisions healed by first intention, and no complication such as intraoperative vascular and nerve injury or postoperative infection occurred. All 13 patients were followed up 20-59 months (mean, 29.3 months). All patients had no limitation of knee extension and flexion. One patient with chronic injury continued to have tenderness in the lateral space of the knee joint, while the remaining patients had no tenderness, swelling, and locking in the lateral space. Immediate postoperative MRI of knee joint showed continuous recovery of the lateral meniscus. At last follow-up, no degenerative changes were observed in X-ray films of knee joint. Except for 1 patient with chronic injury, the MRI of the other patients showed the healing performance after lateral meniscus suture. Lysholm score, IKDC subjective score, Tegner score, and VAS score all significantly improved when compared with those before operation (P<0.05).
CONCLUSION
The edge-to-edge #-shaped suture technique can effectively repair the complete radial tear of the lateral meniscus body, and the short-term effectiveness is satisfactory.
Humans
;
Male
;
Female
;
Adult
;
Tibial Meniscus Injuries/surgery*
;
Arthroscopy/methods*
;
Retrospective Studies
;
Adolescent
;
Young Adult
;
Suture Techniques
;
Treatment Outcome
;
Menisci, Tibial/surgery*
;
Sutures
;
Knee Joint/surgery*
;
Magnetic Resonance Imaging
4.Clinical application of split liver transplantation: a single center report of 203 cases
Qing YANG ; Shuhong YI ; Binsheng FU ; Tong ZHANG ; Kaining ZENG ; Xiao FENG ; Jia YAO ; Hui TANG ; Hua LI ; Jian ZHANG ; Yingcai ZHANG ; Huimin YI ; Haijin LYU ; Jianrong LIU ; Gangjian LUO ; Mian GE ; Weifeng YAO ; Fangfei REN ; Jinfeng ZHUO ; Hui LUO ; Liping ZHU ; Jie REN ; Yan LYU ; Kexin WANG ; Wei LIU ; Guihua CHEN ; Yang YANG
Chinese Journal of Surgery 2024;62(4):324-330
Objective:To investigate the safety and therapeutic effect of split liver transplantation (SLT) in clinical application.Methods:This is a retrospective case-series study. The clinical data of 203 consecutive SLT, 79 living donor liver transplantation (LDLT) and 1 298 whole liver transplantation (WLT) performed at the Third Affiliated Hospital of Sun Yat-sen University from July 2014 to July 2023 were retrospectively analyzed. Two hundred and three SLT liver grafts were obtained from 109 donors. One hundred and twenty-seven grafts were generated by in vitro splitting and 76 grafts were generated by in vivo splitting. There were 90 adult recipients and 113 pediatric recipients. According to time, SLT patients were divided into two groups: the early SLT group (40 cases, from July 2014 to December 2017) and the mature SLT technology group (163 cases, from January 2018 to July 2023). The survival of each group was analyzed and the main factors affecting the survival rate of SLT were analyzed. The Kaplan-Meier method and Log-rank test were used for survival analysis.Results:The cumulative survival rates at 1-, 3-, and 5-year were 74.58%, 71.47%, and 71.47% in the early SLT group, and 88.03%, 87.23%, and 87.23% in the mature SLT group, respectively. Survival rates in the mature SLT group were significantly higher than those in the early SLT group ( χ2=5.560, P=0.018). The cumulative survival rates at 1-, 3- and 5-year were 93.41%, 93.41%, 89.95% in the LDLT group and 87.38%, 81.98%, 77.04% in the WLT group, respectively. There was no significant difference among the mature SLT group, the LDLT group and the WLT group ( χ2=4.016, P=0.134). Abdominal hemorrhage, infection, primary liver graft nonfunction,and portal vein thrombosis were the main causes of early postoperative death. Conclusion:SLT can achieve results comparable to those of WLT and LDLT in mature technology liver transplant centers, but it needs to go through a certain time learning curve.
5.Clinical application of split liver transplantation: a single center report of 203 cases
Qing YANG ; Shuhong YI ; Binsheng FU ; Tong ZHANG ; Kaining ZENG ; Xiao FENG ; Jia YAO ; Hui TANG ; Hua LI ; Jian ZHANG ; Yingcai ZHANG ; Huimin YI ; Haijin LYU ; Jianrong LIU ; Gangjian LUO ; Mian GE ; Weifeng YAO ; Fangfei REN ; Jinfeng ZHUO ; Hui LUO ; Liping ZHU ; Jie REN ; Yan LYU ; Kexin WANG ; Wei LIU ; Guihua CHEN ; Yang YANG
Chinese Journal of Surgery 2024;62(4):324-330
Objective:To investigate the safety and therapeutic effect of split liver transplantation (SLT) in clinical application.Methods:This is a retrospective case-series study. The clinical data of 203 consecutive SLT, 79 living donor liver transplantation (LDLT) and 1 298 whole liver transplantation (WLT) performed at the Third Affiliated Hospital of Sun Yat-sen University from July 2014 to July 2023 were retrospectively analyzed. Two hundred and three SLT liver grafts were obtained from 109 donors. One hundred and twenty-seven grafts were generated by in vitro splitting and 76 grafts were generated by in vivo splitting. There were 90 adult recipients and 113 pediatric recipients. According to time, SLT patients were divided into two groups: the early SLT group (40 cases, from July 2014 to December 2017) and the mature SLT technology group (163 cases, from January 2018 to July 2023). The survival of each group was analyzed and the main factors affecting the survival rate of SLT were analyzed. The Kaplan-Meier method and Log-rank test were used for survival analysis.Results:The cumulative survival rates at 1-, 3-, and 5-year were 74.58%, 71.47%, and 71.47% in the early SLT group, and 88.03%, 87.23%, and 87.23% in the mature SLT group, respectively. Survival rates in the mature SLT group were significantly higher than those in the early SLT group ( χ2=5.560, P=0.018). The cumulative survival rates at 1-, 3- and 5-year were 93.41%, 93.41%, 89.95% in the LDLT group and 87.38%, 81.98%, 77.04% in the WLT group, respectively. There was no significant difference among the mature SLT group, the LDLT group and the WLT group ( χ2=4.016, P=0.134). Abdominal hemorrhage, infection, primary liver graft nonfunction,and portal vein thrombosis were the main causes of early postoperative death. Conclusion:SLT can achieve results comparable to those of WLT and LDLT in mature technology liver transplant centers, but it needs to go through a certain time learning curve.
6.Mechanism of action and clinical research progress of iguratimod in connective tissue diseases
Xiaorong YANG ; Shuhong ZHOU ; Lijiang GUO ; Ying CHEN ; Yingying JI ; Lijie XU
China Pharmacy 2024;35(5):629-634
As a new type of immunosuppressant,iguratimod can mediate the anti-inflammatory signaling pathway by inhibiting the proliferation of inflammatory cells and reducing the release of inflammatory cytokines, and play the role of anti-inflammatory. It can affect the proliferation of immune cells and the expression of immune factors,reduce the production and deposition of immune complexes in the body,and play the role of immune regulation. It can regulate bone metabolism by mediating signaling pathways such as Wnt/β-catenin,Toll-like receptor 4/nuclear factor-κB and osteoprotegerin/nuclear factor-κB receptor activating factor ligand, and play a role in bone protection. It can inhibit pulmonary fibrosis by inhibiting the expression of transforming growth factor β1/ Smad2/3 signaling pathway,tumor necrosis factor-α,interleukin-1,interleukin-6,matrix metalloproteinase-9 and other inflammatory cytokines in lung tissue,and inhibiting the expression of collagen and fibronectin. Its efficacy and safety have been confirmed in the clinical application of rheumatoid arthritis and primary Sjogren syndrome and included in the diagnosis and treatment of the disease. It has also shown good efficacy in the clinical application of other connective tissue diseases such as systemic lupus erythematosus and ankylosing spondylitis,and no obvious safety risks have been found.
7.Exploring the Mechanism of LUO's Neiyi Prescription for the Treatment of Endometriosis Based on the HIF1A/EZH2/ANTXR2 Pathway
Fangli PEI ; Jinjin JIA ; Xiaoxin CHEN ; Shuhong LIN ; Zengxian LIN ; Lizheng WU ; Cheng ZENG
Traditional Chinese Drug Research & Clinical Pharmacology 2024;35(7):993-1000
Objective To investigate the intervention effect and mechanism of LUO's Neiyi Prescription on the proliferation and angiogenesis of eutopic endometrium in rats with endometriosis(EMs)based on hypoxia-inducible factor 1A(HIF1A)/enhancer of zeste homolog 2(EZH2)/anthrax toxin receptor 2(ANTXR2)signaling pathway.Methods SD rats were randomly divided into sham operation group,model group,Danazol group(4.2 g·kg-1),low-dose LUO's Neiyi Prescription group and high-dose LUO's Neiyi Prescription group(15.74,31.48 g·kg-1),eight rats in each group.The rat model of EMs with qi stagnation and blood stasis syndrome was constructed by autologous endometrial transplantation combined with multi-factor intervention.Intragastric administration was given once a day for 28 consecutive days.The pathological changes of endometrial tissue were observed by HE staining.The expression levels of proliferating cell protein 67(Ki67)and platelet endothelial cell adhesion molecule 1(CD31)in endometrial tissue were detected by immunohistochemistry.The mRNA and protein expression levels of HIF1A,EZH2 and ANTXR2 in endometrial tissues were detected by qRT-PCR and Western Blot.The expression levels of YAP1,CD44 and β-catenin in endometrial tissues were detected by Western Blot.Results Compared with the sham operation group,the epithelial cells of the eutopic endometrium of the model group were thickened,the interstitial cells were arranged disorderly,and the inflammatory cells increased.The expression levels of Ki67 and CD31 in endometrial tissues were significantly increased(P<0.01),the mRNA and protein expression levels of HIF1A and ANTXR2 were significantly increased(P<0.01),while the mRNA and protein expression levels of EZH2 were significantly decreased(P<0.01),and the protein expression levels of YAP1,CD44 and β-catenin were significantly increased(P<0.01).Compared with the model group,the epithelial layer of the eutopic endometrial tissue of the rats in each administration group became thinner,the interstitial disorder and inflammatory infiltration were improved,and the levels of Ki67 and CD31 in the eutopic endometrial tissue were significantly decreased(P<0.01).The mRNA and protein expression levels of HIF1A and ANTXR2 in the endometrium of rats in the Danazol group and the high-dose LUO's Neiyi Prescription group were significantly decreased(P<0.05,P<0.01),and the mRNA and protein expression levels of EZH2 were significantly increased(P<0.05,P<0.01).The protein expression levels of YAP1,CD44 and β-catenin in endometrial tissue of rats in each administration group were significantly decreased(P<0.05,P<0.01).Conclusion LUO's Neiyi Prescription can play a role in the treatment of EMs by inhibiting the proliferation and angiogenesis of eutopic endometrial cells,and its mechanism may be related to the inhibition of HIF1A/EZH2/ANTXR2 signaling pathway.
8.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
9.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
10.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.

Result Analysis
Print
Save
E-mail