1.Clinical efficacy of demineralized dentin matrix particles in immediate implantation for bone defects in posterior region: a 1 to 5-year follow-up study.
Hao WU ; Ning CAO ; Liangwei CAO ; Fei YU ; Xu ZHANG ; Shibo WEI ; Hongwu WEI ; Shuigen GUO
West China Journal of Stomatology 2025;43(4):570-583
OBJECTIVES:
This study aims to evaluate the short- to medium-term clinical efficacy of demineralized dentin matrix (DDM) particles applied during the immediate implantation of alveolar bone defects in the posterior region.
METHODS:
A total of 76 patients with 110 simple taper retentive implants were included in the conducted study and divided into Groups A and B in accordance with the bone grafting materials. Cone beam computed tomography and panoramic radiographs were taken immediately after implant surgery, immediate crown repair, and final follow-up time. The average follow-up time for Groups A and B was recorded. The primary observed clinical indicators were overall survival rate of the implant, bone resorption of the mesial and distal margins of the implant, buccal bone width resorption at the platform level and 1 mm below the platform, and bone height of the implant. Implant complication was a secondary observed clinical indicator.
RESULTS:
During the 1-to-5-year follow-up observation period, the mean follow-up of Group A was 38.2 months while that of Group B was 39.9 months. In Group A, two implants failed, one of which fractured, and implant overall survival rate was 96.4%. Four implants failed in Group B due to peri-implantitis, and implant overall survival rate was 92.6%. No statistically significant difference in implant overall survival rate was found between the two groups (P>0.05). In Group A, the average bone resorption in the mesial and distal margins of the implants was (1.011±2.047) mm and (0.841±2.183) mm, respectively. In Group B, the average bone resorption of the mesial and distal margins of the implants was (1.546±1.778) mm and (1.431±1.909) mm, respectively. No statistically significant difference was noted between the two groups (P>0.05). In Group A, buccal bone width resorption at the platform level and 1 mm below the platform of the implant was (0.782±2.084) mm and (0.681±2.307) mm, respectively. In Group B, buccal bone width resorption at the platform level and 1 mm below the platform of implant was (1.071±1.474) mm and (0.949±1.909) mm, respectively. No statistically significant difference was found between the two groups (P>0.05). In Group A, the buccal bone height of resorption of the implant was (1.044±2.214) mm. In Group B, the buccal bone height of resorption of the implant was (1.075±1.456) mm. No statistically significant difference in bone height was observed between the two groups (P>0.05).
CONCLUSIONS
During the 1-to-5-year follow-up observation period, DDM particles can effectively increase the height and width of alveolar bone, and they can achieve the same effect of maintaining alveolar bone contour and bone augmentation compared with deproteinized inorganic calf bone. DDM particles can be used as a potential new bone grafting material for the treatment of bone defects in clinical practice.
Humans
;
Follow-Up Studies
;
Dentin
;
Cone-Beam Computed Tomography
;
Dental Implants
;
Male
;
Female
;
Adult
;
Alveolar Bone Loss/surgery*
;
Middle Aged
;
Bone Transplantation
;
Radiography, Panoramic
;
Dental Implantation, Endosseous/methods*
;
Immediate Dental Implant Loading
2.Analysis of risk factors for early failure of simple taper retentive implants.
Xu ZHANG ; Zengxuan WAN ; Shibo WEI ; Fei YU ; Ning CAO ; Liangwei CAO ; Hao WU ; Shuigen GUO ; Hongwu WEI
West China Journal of Stomatology 2025;43(6):780-788
OBJECTIVES:
To explore the related risk factors of early failure of simple taper retentive implants, and to provide theoretical guidance for clinical work.
METHODS:
Collect cases of patients who visited the Department of Stomatology of the Fourth Affiliated Hospital of Nanchang University from January 2021 to June 2024, received simple taper retentive implants, and had complete medical records. Taking the implants as the unit, analyze the influence of patient-related factors (gender, age, smoking history, hypertension history, diabetes history), implant-related factors (implant length, implant diameter, implant surface treatment), and surgical-related factors (implant site, implant timing, simultaneous maxillary sinus floor elevation, simultaneous bone augmentation) on the early failure of implants. Univariate analysis and multivariate analysis were adopted to explore the potential risk factors for early failure of simple taper retentive implants.
RESULTS:
A total of 3,533 simple taper retentive from 1,681 patients were included during the study period. Among them, 53 implants from 49 patients experienced early failure, with an early failure rate of 2.9% at the patient le-vel and 1.5% at the implant level. Multivariate analysis revealed that smoking (OR=2.148, P=0.021), the anterior mandibular region (OR=3.669, P=0.006), and the posterior maxillary region (OR=2.191, P=0.033) were risk factors for early failure of simple taper retentive implants. In the univariate analysis, simultaneous maxillary sinus floor elevation had a higher risk of early failure, but this effects was no longer significant in the multivariate analysis (P>0.05).
CONCLUSIONS
Smoking, the anterior mandibular region, and the posterior maxillary region are risk factors for the early failure of simple taper retentive implants, and could be comprehensively considered in the preoperative treatment plan.
Humans
;
Risk Factors
;
Male
;
Female
;
Middle Aged
;
Dental Implants
;
Adult
;
Smoking/adverse effects*
;
Dental Restoration Failure
;
Aged
3.Immediate implantation of simple taper retentive implants in chronic apical infected teeth in the posterior region:a 5-year clinical observation
Xu ZHANG ; Shibo WEI ; Fei YU ; Hao WU ; Liangwei CAO ; Ning CAO ; Hongwu WEI ; Shuigen GUO
West China Journal of Stomatology 2024;42(6):764-772
Objective This study aims to evaluate the mid-and long-term clinical efficacies of simple taper retentive implants for immediate placement in chronic apical infected teeth in the posterior region.Methods A total of 36 pa-tients with 41 simple taper retentive implants were included in the study conducted.These patients underwent immediate implant treatment for teeth with chronic apical infection in the posterior region.The soft and hard tissues surrounding the implants were assessed and documented over a period of 5 years following the completion of crown restoration.Re-sults During the 5 years follow-up period,one implant failed with mobility,and the implant survival rate was 97.6%.The mean marginal bone resorption was(-0.74±1.03)mm from the immediate post-implant placement to the immediate post-crown restoration,and the difference in marginal bone heights between the two time points was statistically signifi-cant(P<0.05).The mean marginal bone resorption was(-0.21±0.70)mm from the immediate post-crown restoration to the 5-year post-crown restoration,and the difference in marginal bone height between the two time points was not statisti-cally significant(P>0.05).No significant difference(P>0.05)was observed in bone resorption between mesial and distal,maxillary and mandibular,different tooth posi-tions,and different implant lengths.The soft tissue sur-rounding the implants remained healthy at the 5 years follow-up period,one implant exhibited peri-implantitis,and no mechanical complications were observed.The overall satisfaction of patients was good.Conclusion Immediate place-ment of simple taper retentive implants after thorough debridement of chronic infected alveolar socket in the posterior re-gion can achieve good mid-and long-term clinical outcomes after 5 years of loading.The soft and hard tissues were maintained in a steady state,which expanded the indications for immediate implantation.
4.Decision tree-enabled establishment and validation of intelligent verification rules for blood analysis results
Linlin QU ; Xu ZHAO ; Liang HE ; Yehui TAN ; Yingtong LI ; Xianqiu CHEN ; Zongxing YANG ; Yue CAI ; Beiying AN ; Dan LI ; Jin LIANG ; Bing HE ; Qiuwen SUN ; Yibo ZHANG ; Xin LYU ; Shibo XIONG ; Wei XU
Chinese Journal of Laboratory Medicine 2024;47(5):536-542
Objective:To establish a set of artificial intelligence (AI) verification rules for blood routine analysis.Methods:Blood routine analysis data of 18 474 hospitalized patients from the First Hospital of Jilin University during August 1st to 31st, 2019, were collected as training group for establishment of the AI verification rules,and the corresponding patient age, microscopic examination results, and clinical diagnosis information were collected. 92 laboratory parameters, including blood analysis report parameters, research parameters and alarm information, were used as candidate conditions for AI audit rules; manual verification combining microscopy was considered as standard, marked whether it was passed or blocked. Using decision tree algorithm, AI audit rules are initially established through high-intensity, multi-round and five-fold cross-validation and AI verification rules were optimized by setting important mandatory cases. The performance of AI verification rules was evaluated by comparing the false negative rate, precision rate, recall rate, F1 score, and pass rate with that of the current autoverification rules using Chi-square test. Another cohort of blood routine analysis data of 12 475 hospitalized patients in the First Hospital of Jilin University during November 1sr to 31st, 2023, were collected as validation group for validation of AI verification rules, which underwent simulated verification via the preliminary AI rules, thus performance of AI rules were analyzed by the above indicators. Results:AI verification rules consist of 15 rules and 17 parameters and do distinguish numeric and morphological abnormalities. Compared with auto-verification rules, the true positive rate, the false positive rate, the true negative rate, the false negative rate, the pass rate, the accuracy, the precision rate, the recall rate and F1 score of AI rules in training group were 22.7%, 1.6%, 74.5%, 1.3%, 75.7%, 97.2%, 93.5%, 94.7%, 94.1, respectively.All of them were better than auto-verification rules, and the difference was statistically significant ( P<0.001), and with no important case missed. In validation group, the true positive rate, the false positive rate, the true negative rate, the false negative rate, the pass rate, the accuracy, the precision rate, the recall rate and F1 score were 19.2%, 8.2%, 70.1%, 2.5%, 72.6%, 89.2%, 70.0%, 88.3%, 78.1, respectively, Compared with the auto-verification rules, The false negative rate was lower, the false positive rate and the recall rate were slightly higher, and the difference was statistically significant ( P<0.001). Conclusion:A set of the AI verification rules are established and verified by using decision tree algorithm of machine learning, which can identify, intercept and prompt abnormal results stably, and is moresimple, highly efficient and more accurate in the report of blood analysis test results compared with auto-vefication.
5.Efficacy and safety of neoadjuvant therapy with TCbHP regimen for human epidermal growth factor receptor 2-positive breast cancer
Donghong XU ; Xiangdong WU ; Shibo ZHANG ; Yongtao DU ; Chongzhu HU ; Enqing WANG
Cancer Research and Clinic 2024;36(8):590-593
Objective:To investigate the efficacy and safety of neoadjuvant therapy with trastuzumab and pertuzumab combined with taxane and platinum drugs (TCbHP) regimen for human epidermal growth factor receptor 2 (HER2)-positive breast cancer.Methods:A retrospective case series study was conducted. The clinical data of HER2-positive breast cancer patients who received neoadjuvant therapy with 21-day TCbHP regimen and completed subsequent surgery in 11 tertiary-level hospitals in Hebei Province from June 2019 to December 2021 were retrospectively analyzed, and the total pathological complete remission (tpCR) rate, the incidence of grade ≥3 adverse events, and the completion rate of the established regimen were statistically analyzed.Results:A total of 78 female patients were included and the median age [ M ( Q1, Q3)] was 54.0 years (48.5 years, 57.5 years). The tpCR rate was 64.1% (50/78). Subgroup analysis showed that the tpCR rate in the HER2 immunohistochemistry (IHC)+++ group was higher than that in the HER2 IHC++ and fluorescence in situ hybridization-positive group [68.6% (48/70) vs. 25.0% (2/8)], and the difference was statistically significant ( χ2 = 4.18, P = 0.041); the tpCR rate in the hormone-receptor negative group was higher than that in the hormone-receptor positive group [81.8% (27/33) vs. 51.1% (23/45)], and the difference was statistically significant ( χ2 = 7.80, P = 0.005); the tpCR rate in the albumin-bound paclitaxel group was higher than that in the docetaxel group [72.3% (34/47) vs. 48.3% (14/29)], and the difference was statistically significant ( χ2 = 4.46, P = 0.035). The incidence of ≥ grade 3 adverse reactions was 12.8% (10/78) in 78 patients, and the completion rate of the established regimen was 92.3% (72/78). Conclusions:Neoadjuvant therapy with TCbHP regimen for HER2-positive breast cancer shows a definite efficacy, good safety and tolerance.
6.Prediction of Screw Loosening After Dynamic Pedicle Screw Fixation With Lumbar Polyetheretherketone Rods Using Magnetic Resonance Imaging-Based Vertebral Bone Quality Score
Guozheng JIANG ; Luchun XU ; Yukun MA ; Jianbin GUAN ; Yongdong YANG ; Wenqing ZHONG ; Wenhao LI ; Shibo ZHOU ; JiaWei SONG ; Ningning FENG ; Ziye QIU ; Zeyu LI ; YiShu ZHOU ; Letian MENG ; Yi QU ; Xing YU
Neurospine 2024;21(2):712-720
Objective:
To investigate the correlation between magnetic resonance imaging-based vertebral bone quality (VBQ) score and screw loosening after dynamic pedicle screw fixation with polyetheretherketone (PEEK) rods, and evaluate its predictive value.
Methods:
A retrospective analysis was conducted on the patients who underwent dynamic pedicle screw fixation with PEEK rods from March 2017 to June 2022. Data on age, sex, body mass index, hypertension, diabetes, hyperlipidemia history, long-term smoking, alcohol consumption, VBQ score, L1–4 average Hounsfield unit (HU) value, surgical fixation length, and the lowest instrumented vertebra were collected. Logistic regression analysis was employed to assess the relationship between VBQ score and pedicle screw loosening (PSL).
Results:
A total of 24 patients experienced PSL after surgery (20.5%). PSL group and non-PSL group showed statistical differences in age, number of fixed segments, fixation to the sacrum, L1–4 average HU value, and VBQ score (p < 0.05). The VBQ score in the PSL group was higher than that in the non-PSL group (3.56 ± 0.45 vs. 2.77 ± 0.31, p < 0.001). In logistic regression analysis, VBQ score (odds ratio, 3.425; 95% confidence interval, 1.552–8.279) were identified as independent risk factors for screw loosening. The area under the receiver operating characteristic curve for VBQ score predicting PSL was 0.819 (p < 0.05), with the optimal threshold of 3.15 (sensitivity, 83.1%; specificity, 80.5%).
Conclusion
The VBQ score can independently predict postoperative screw loosening in patients undergoing lumbar dynamic pedicle screw fixation with PEEK rods, and its predictive value is comparable to HU value.
7.Prediction of Screw Loosening After Dynamic Pedicle Screw Fixation With Lumbar Polyetheretherketone Rods Using Magnetic Resonance Imaging-Based Vertebral Bone Quality Score
Guozheng JIANG ; Luchun XU ; Yukun MA ; Jianbin GUAN ; Yongdong YANG ; Wenqing ZHONG ; Wenhao LI ; Shibo ZHOU ; JiaWei SONG ; Ningning FENG ; Ziye QIU ; Zeyu LI ; YiShu ZHOU ; Letian MENG ; Yi QU ; Xing YU
Neurospine 2024;21(2):712-720
Objective:
To investigate the correlation between magnetic resonance imaging-based vertebral bone quality (VBQ) score and screw loosening after dynamic pedicle screw fixation with polyetheretherketone (PEEK) rods, and evaluate its predictive value.
Methods:
A retrospective analysis was conducted on the patients who underwent dynamic pedicle screw fixation with PEEK rods from March 2017 to June 2022. Data on age, sex, body mass index, hypertension, diabetes, hyperlipidemia history, long-term smoking, alcohol consumption, VBQ score, L1–4 average Hounsfield unit (HU) value, surgical fixation length, and the lowest instrumented vertebra were collected. Logistic regression analysis was employed to assess the relationship between VBQ score and pedicle screw loosening (PSL).
Results:
A total of 24 patients experienced PSL after surgery (20.5%). PSL group and non-PSL group showed statistical differences in age, number of fixed segments, fixation to the sacrum, L1–4 average HU value, and VBQ score (p < 0.05). The VBQ score in the PSL group was higher than that in the non-PSL group (3.56 ± 0.45 vs. 2.77 ± 0.31, p < 0.001). In logistic regression analysis, VBQ score (odds ratio, 3.425; 95% confidence interval, 1.552–8.279) were identified as independent risk factors for screw loosening. The area under the receiver operating characteristic curve for VBQ score predicting PSL was 0.819 (p < 0.05), with the optimal threshold of 3.15 (sensitivity, 83.1%; specificity, 80.5%).
Conclusion
The VBQ score can independently predict postoperative screw loosening in patients undergoing lumbar dynamic pedicle screw fixation with PEEK rods, and its predictive value is comparable to HU value.
8.Prediction of Screw Loosening After Dynamic Pedicle Screw Fixation With Lumbar Polyetheretherketone Rods Using Magnetic Resonance Imaging-Based Vertebral Bone Quality Score
Guozheng JIANG ; Luchun XU ; Yukun MA ; Jianbin GUAN ; Yongdong YANG ; Wenqing ZHONG ; Wenhao LI ; Shibo ZHOU ; JiaWei SONG ; Ningning FENG ; Ziye QIU ; Zeyu LI ; YiShu ZHOU ; Letian MENG ; Yi QU ; Xing YU
Neurospine 2024;21(2):712-720
Objective:
To investigate the correlation between magnetic resonance imaging-based vertebral bone quality (VBQ) score and screw loosening after dynamic pedicle screw fixation with polyetheretherketone (PEEK) rods, and evaluate its predictive value.
Methods:
A retrospective analysis was conducted on the patients who underwent dynamic pedicle screw fixation with PEEK rods from March 2017 to June 2022. Data on age, sex, body mass index, hypertension, diabetes, hyperlipidemia history, long-term smoking, alcohol consumption, VBQ score, L1–4 average Hounsfield unit (HU) value, surgical fixation length, and the lowest instrumented vertebra were collected. Logistic regression analysis was employed to assess the relationship between VBQ score and pedicle screw loosening (PSL).
Results:
A total of 24 patients experienced PSL after surgery (20.5%). PSL group and non-PSL group showed statistical differences in age, number of fixed segments, fixation to the sacrum, L1–4 average HU value, and VBQ score (p < 0.05). The VBQ score in the PSL group was higher than that in the non-PSL group (3.56 ± 0.45 vs. 2.77 ± 0.31, p < 0.001). In logistic regression analysis, VBQ score (odds ratio, 3.425; 95% confidence interval, 1.552–8.279) were identified as independent risk factors for screw loosening. The area under the receiver operating characteristic curve for VBQ score predicting PSL was 0.819 (p < 0.05), with the optimal threshold of 3.15 (sensitivity, 83.1%; specificity, 80.5%).
Conclusion
The VBQ score can independently predict postoperative screw loosening in patients undergoing lumbar dynamic pedicle screw fixation with PEEK rods, and its predictive value is comparable to HU value.
9.Prediction of Screw Loosening After Dynamic Pedicle Screw Fixation With Lumbar Polyetheretherketone Rods Using Magnetic Resonance Imaging-Based Vertebral Bone Quality Score
Guozheng JIANG ; Luchun XU ; Yukun MA ; Jianbin GUAN ; Yongdong YANG ; Wenqing ZHONG ; Wenhao LI ; Shibo ZHOU ; JiaWei SONG ; Ningning FENG ; Ziye QIU ; Zeyu LI ; YiShu ZHOU ; Letian MENG ; Yi QU ; Xing YU
Neurospine 2024;21(2):712-720
Objective:
To investigate the correlation between magnetic resonance imaging-based vertebral bone quality (VBQ) score and screw loosening after dynamic pedicle screw fixation with polyetheretherketone (PEEK) rods, and evaluate its predictive value.
Methods:
A retrospective analysis was conducted on the patients who underwent dynamic pedicle screw fixation with PEEK rods from March 2017 to June 2022. Data on age, sex, body mass index, hypertension, diabetes, hyperlipidemia history, long-term smoking, alcohol consumption, VBQ score, L1–4 average Hounsfield unit (HU) value, surgical fixation length, and the lowest instrumented vertebra were collected. Logistic regression analysis was employed to assess the relationship between VBQ score and pedicle screw loosening (PSL).
Results:
A total of 24 patients experienced PSL after surgery (20.5%). PSL group and non-PSL group showed statistical differences in age, number of fixed segments, fixation to the sacrum, L1–4 average HU value, and VBQ score (p < 0.05). The VBQ score in the PSL group was higher than that in the non-PSL group (3.56 ± 0.45 vs. 2.77 ± 0.31, p < 0.001). In logistic regression analysis, VBQ score (odds ratio, 3.425; 95% confidence interval, 1.552–8.279) were identified as independent risk factors for screw loosening. The area under the receiver operating characteristic curve for VBQ score predicting PSL was 0.819 (p < 0.05), with the optimal threshold of 3.15 (sensitivity, 83.1%; specificity, 80.5%).
Conclusion
The VBQ score can independently predict postoperative screw loosening in patients undergoing lumbar dynamic pedicle screw fixation with PEEK rods, and its predictive value is comparable to HU value.
10.Prediction of Screw Loosening After Dynamic Pedicle Screw Fixation With Lumbar Polyetheretherketone Rods Using Magnetic Resonance Imaging-Based Vertebral Bone Quality Score
Guozheng JIANG ; Luchun XU ; Yukun MA ; Jianbin GUAN ; Yongdong YANG ; Wenqing ZHONG ; Wenhao LI ; Shibo ZHOU ; JiaWei SONG ; Ningning FENG ; Ziye QIU ; Zeyu LI ; YiShu ZHOU ; Letian MENG ; Yi QU ; Xing YU
Neurospine 2024;21(2):712-720
Objective:
To investigate the correlation between magnetic resonance imaging-based vertebral bone quality (VBQ) score and screw loosening after dynamic pedicle screw fixation with polyetheretherketone (PEEK) rods, and evaluate its predictive value.
Methods:
A retrospective analysis was conducted on the patients who underwent dynamic pedicle screw fixation with PEEK rods from March 2017 to June 2022. Data on age, sex, body mass index, hypertension, diabetes, hyperlipidemia history, long-term smoking, alcohol consumption, VBQ score, L1–4 average Hounsfield unit (HU) value, surgical fixation length, and the lowest instrumented vertebra were collected. Logistic regression analysis was employed to assess the relationship between VBQ score and pedicle screw loosening (PSL).
Results:
A total of 24 patients experienced PSL after surgery (20.5%). PSL group and non-PSL group showed statistical differences in age, number of fixed segments, fixation to the sacrum, L1–4 average HU value, and VBQ score (p < 0.05). The VBQ score in the PSL group was higher than that in the non-PSL group (3.56 ± 0.45 vs. 2.77 ± 0.31, p < 0.001). In logistic regression analysis, VBQ score (odds ratio, 3.425; 95% confidence interval, 1.552–8.279) were identified as independent risk factors for screw loosening. The area under the receiver operating characteristic curve for VBQ score predicting PSL was 0.819 (p < 0.05), with the optimal threshold of 3.15 (sensitivity, 83.1%; specificity, 80.5%).
Conclusion
The VBQ score can independently predict postoperative screw loosening in patients undergoing lumbar dynamic pedicle screw fixation with PEEK rods, and its predictive value is comparable to HU value.

Result Analysis
Print
Save
E-mail