1.Effects of Panax notoginseng saponins on gastric mucosal injury and inflammatory response in rats with chronic atrophic gastritis
China Pharmacy 2026;37(8):1021-1026
OBJECTIVE To investigate the effects and potential mechanism of Panax notoginseng saponins (PNS) on gastric mucosal injury and inflammatory response in rats with chronic atrophic gastritis (CAG) via the stem cell factor(SCF)/cellular tyrosine kinase receptor(c-kit) signaling pathway. METHODS Male SD rats were used to establish a CAG rat model through intragastric administration of N -methyl- N ′-nitro- N -nitrosoguanidine combined with an irregular diet. Successfully modeled rats were randomly divided into a model group, positive control-vitacoenzyme group (Positive group, 250 mg/kg), PNS low- and high-dose groups (PNS-L and PNS-H groups, 9, 18 mg/kg), and high-dose PNS+SCF/c-kit inhibitor group (PNS-H+ISCK03 group, 18 mg/kg+47 mg/kg), with 8 rats in each group. Additionally, 8 healthy rats were selected as a control group. After the final administration, the activities of serum gastrin (GAS), motilin (MTL) and pancreatic polypeptide (PP), as well as the levels of tumor necrosis factor-α (TNF-α), interleukin-10 (IL-10), and IL-8 in gastric mucosal tissues, were measured in each group. Pathological changes of the gastric mucosal and ultrastructure of the epithelial cells were observed, and gastric mucosal atrophy was scored. Cell apoptosis in gastric mucosal tissues and the expressions of proliferating cell nuclear antigen (PCNA), nuclear factor-κB p65 (NF-κB p65), SCF and c-kit were detected. RESULTS Compared with the control group, the model group showed significantly increased inflammatory cell infiltration in the gastric mucosal, extensive epithelial cell detachment, severe ultrastructural damage, and significantly elevated or up-regulated gastric mucosal atrophy score, TNF-α and IL-8 levels in gastric mucosal, cell apoptosis rate, and NF-κB p65 protein expression. Meanwhile, serum levels of GAS and MTL, PP activity, the level of IL-10 in gastric mucosal tissue, and protein expressions of PCNA and SCF, as well as the phosphorylation level of c-kit, were significantly decreased or down-regulated ( P <0.05). Compared with the model group, Positive, PNS-L and PNS-H groups exhibited markedly improved pathological changes in the gastric mucosal and significant amelioration of the quantitative indicators, with the PNS-H group showing significantly better improvement than the PNS-L group ( P <0.05). However, ISCK03 significantly reversed the ameliorative effects of high-dose PNS on the above indicators in rats ( P <0.05). CONCLUSIONS PNS improves gastric mucosal injury in CAG rats by reducing the inflammatory response and promoting gastric mucosal repair; these effects may be related to the activation of the SCF/c-kit signaling pathway.
2.Fluorescence Suppression Method of Raman Spectroscopy and Its Application in Skin and Cosmetics Analysis
Yun-Xia CHEN ; Jia-Rong WANG ; Jian-Yu ZHU ; Shi-Wen LIN ; Ya-Nan LIU ; Xiao-Yue MA ; Guang-Cheng XI ; Juan LIU
Progress in Biochemistry and Biophysics 2026;53(7):1914-1926
Owing to its inherent advantages—such as being non-destructive, rapid, highly molecule-specific, and minimally interfered with by moisture—Raman spectroscopy has been widely adopted in the fields of skin barrier function assessment, monitoring the transdermal penetration of active cosmetic ingredients, and the identification and quality control of cosmetic products. Despite these strengths, the practical application of this technique faces a significant bottleneck: the strong fluorescence background generated by endogenous skin components and exogenous cosmetic additives. Endogenous skin substances, such as structural proteins (e.g., collagen and elastin), metabolic coenzymes (e.g., nicotinamide adenine dinucleotide), and pigments (e.g., melanin), together with exogenous cosmetic constituents like organic colorants, chemical sunscreens, and fragrances, often possess strong absorption and emission characteristics. When excited by lasers, these components produce a fluorescence background that can be 106 to 108 times stronger than the Raman scattering signals, effectively masking the inherently weak vibrational fingerprint information. In recent years, driven by the rapid development of optoelectronic hardware and artificial intelligence algorithms, fluorescence suppression strategies have evolved from isolated, single-method approaches into comprehensive, multi-level synergistic systems. These systems are categorized into three distinct tiers: sample preparation, signal acquisition, and data processing. At the sample preparation level, techniques such as photobleaching and surface-enhanced Raman spectroscopy (SERS) are employed to eliminate or bypass the generation of fluorescence at the source. At the signal acquisition level, instrumental improvements—including the use of long-wavelength near-infrared excitation (typically 785 nm or 1 064 nm), confocal spatial filtering, and shifted excitation Raman difference spectroscopy (SERDS)— are utilized to physically isolate Raman signals from the fluorescence background. Furthermore, at the data processing level, numerical baseline correction methods such as polynomial fitting, penalized least squares (e.g., airPLS, arPLS), wavelet transform, and derivative algorithms are increasingly integrated into the analytical pipeline to extract Raman spectral features from mixed signals without increasing hardware costs or acquisition time. This review provides a systematic categorization and critical evaluation of these fluorescence suppression methods, detailing their underlying principles, technical advantages, and inherent limitations in diverse experimental setups. By focusing on critical application scenarios—including skin barrier assessment, percutaneous absorption monitoring, the routine quality control of cosmetics, and the emerging field of portable on-site detection—this paper explores the current state of technique selection and optimization. Finally, the article discusses future development trends, emphasizing the necessity of constructing adaptive, tiered suppression strategies, developing intelligent and automated data processing algorithms, and promoting the integration of portable, multi-modal diagnostic devices. The objective of this review is to provide a comprehensive technical reference to facilitate the transition of Raman spectroscopy from a specialized laboratory tool into a routine, robust analytical platform for advancements in skin science and cosmetic research.
3.Expert consensus on electronic patient-reported outcome-based symptom management for perioperative lung cancer patients (version 2026)
Wei DAI ; Cheng LEI ; Yuanqiang ZHANG ; Rong ZHANG ; Pengyu Jinming ; Jinming XU ; Yuzhen ZHENG ; Liang ZHAO ; Guibin QIAO ; Guowei CHE ; Jian HU ; Lei JIANG ; Jie LI ; Qiang LI ; Qiuling SHI
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2026;33(08):1166-1178
Patients with lung cancer experience a heavy symptom burden during the perioperative period, which seriously affects their recovery and quality of life. Traditional symptom management models rely mainly on scheduled ward rounds during hospitalization and outpatient follow-up after discharge. However, they have limitations such as delayed symptom recognition, lack of post-discharge monitoring, and non-quantitative symptom assessment, which often lead to delayed interventions and low patient satisfaction. In recent years, the symptom management model based on electronic patient-reported outcomes (ePRO) has been increasingly valued in clinical practice. Existing high-level evidence from both domestic and international studies indicates that, through proactive monitoring, real-time alerts, and remote interventions, this model enables dynamic and continuous symptom management and helps improve patient recovery and healthcare experience. As a supplement to routine medical care, the ePRO-based symptom management model aims to enhance the quality of care rather than replace existing medical processes. To promote the standardized application of this model in perioperative lung cancer care, this consensus integrates domestic and international evidence. After multiple rounds of voting by more than 50 experts, it formulates 12 consensus statements covering the three core components, symptom monitoring, alerting, and intervention, to provide scientific and practical recommendations for clinical practice.
4.Residual Inflammatory Risk and Intracranial Atherosclerosis Plaque Vulnerability: Insights From High-Resolution Magnetic Resonance Imaging
Ying YU ; Rongrong CUI ; Xin HE ; Xinxin SHI ; Zhikai HOU ; Yuesong PAN ; Mingyao LI ; Jiabao YANG ; Zhongrong MIAO ; Yongjun WANG ; Rong WANG ; Xin LOU ; Long YAN ; Ning MA
Journal of Stroke 2025;27(2):207-216
Background:
and Purpose This study aimed to investigate the association between residual inflammatory risk (RIR) and vulnerable plaques using high-resolution magnetic resonance imaging (HRMRI) in symptomatic intracranial atherosclerotic stenosis (ICAS).
Methods:
This retrospective study included 70%–99% symptomatic ICAS patients hospitalized from January 2016 to December 2022. Patients were classified into four groups based on high-sensitivity C-reactive protein (hs-CRP) and low-density lipoprotein cholesterol (LDL-C): residual cholesterol inflammatory risk (RCIR, hs-CRP ≥3 mg/L and LDL-C ≥2.6 mmol/L), RIR (hs-CRP ≥3 mg/L and LDL-C <2.6 mmol/L), residual cholesterol risk (RCR, hs-CRP <3 mg/L and LDL-C ≥2.6 mmol/L), and no residual risk (NRR, hs-CRP <3 mg/L and LDL-C <2.6 mmol/L). Vulnerable plaque features on HRMRI included positive remodeling, diffuse distribution, intraplaque hemorrhage, and strong enhancement.
Results:
Among 336 included patients, 21, 60, 58, and 197 were assigned to the RCIR, RIR, RCR, and NRR groups, respectively. Patients with RCIR (adjusted odds ratio [aOR], 3.606; 95% confidence interval [CI], 1.346–9.662; P=0.011) and RIR (aOR, 3.361; 95% CI, 1.774–6.368, P<0.001) had higher risks of strong enhancement than those with NRR. Additionally, patients with RCIR (aOR, 2.965; 95% CI, 1.060–8.297; P=0.038) were more likely to have intraplaque hemorrhage compared with those with NRR. In the sensitivity analysis, RCR (aOR, 2.595; 95% CI, 1.201–5.608; P=0.015) exhibited an additional correlation with an increased risk of intraplaque hemorrhage.
Conclusion
In patients with symptomatic ICAS, RIR is associated with a higher risk of intraplaque hemorrhage and strong enhancement, indicating an increased vulnerability to atherosclerotic plaques.
5.Efficacy and safety of different daily doses of aspirin in prevention of preeclampsia:a meta-analysis
Xiaoxia SHI ; Yan BAI ; Liting RONG ; Yuanjie DU ; Lijuan YUAN
China Pharmacy 2025;36(21):2733-2737
OBJECTIVE To compare the efficacy and safety of different daily doses of aspirin in the prevention of preeclampsia (PE). METHODS The case-control studies and prospective randomized controlled trials on aspirin with daily dose ≥ 100 mg (trial group) vs. <100 mg (control group) in the prevention of PE were retrieved from PubMed, Medline, Embase, the Cochrane Library, CNKI, China Biomedical Literatue Database and Wanfang Data from base-building to January 2025. After literature screening, data extraction and quality evaluation, meta-analysis was performed by using RevMan 5.3 software. RESULTS A total of 11 literatures were included, involving 3 052 pregnant women. Meta-analysis showed the incidence of PE [RR=0.63, 95%CI (0.53,0.76), P<0.000 01], gestational hypertension [RR=0.69, 95%CI (0.50,0.94),P=0.02], preterm birth [RR=0.56, 95%CI (0.47,0.66), P<0.000 01], and intrauterine growth retardation [RR=0.73,95%CI (0.61,0.87),P=0.000 5] in trial groups were significantly lower than control group. The incidence of postpartum hemorrhage between the two groups had no statistically significant difference [RR=1.17, 95%CI (0.90,1.53),P=0.25]. Subgroup analysis showed that the incidence of PE in Chinese pregnant women taking 150 mg of aspirin was significantly higher than taking 100 mg of aspirin [RR=3.40, 95%CI (1.29, 8.93), P=0.01]; but there was no significant difference between the two groups in the incidences of postpartum hemorrhage, preterm birth (P>0.05). CONCLUSIONS Aspirin with daily dose ≥100 mg is more effective in preventing PE than daily dose <100 mg, with lower rates of gestational hypertension, preterm birth, and intrauterine growth retardation. It does not increase the risk of postpartum hemorrhage. For pregnant women in China, daily dose 100 mg of aspirin may be more effective in preventing PE than 150 mg.
6.Residual Inflammatory Risk and Intracranial Atherosclerosis Plaque Vulnerability: Insights From High-Resolution Magnetic Resonance Imaging
Ying YU ; Rongrong CUI ; Xin HE ; Xinxin SHI ; Zhikai HOU ; Yuesong PAN ; Mingyao LI ; Jiabao YANG ; Zhongrong MIAO ; Yongjun WANG ; Rong WANG ; Xin LOU ; Long YAN ; Ning MA
Journal of Stroke 2025;27(2):207-216
Background:
and Purpose This study aimed to investigate the association between residual inflammatory risk (RIR) and vulnerable plaques using high-resolution magnetic resonance imaging (HRMRI) in symptomatic intracranial atherosclerotic stenosis (ICAS).
Methods:
This retrospective study included 70%–99% symptomatic ICAS patients hospitalized from January 2016 to December 2022. Patients were classified into four groups based on high-sensitivity C-reactive protein (hs-CRP) and low-density lipoprotein cholesterol (LDL-C): residual cholesterol inflammatory risk (RCIR, hs-CRP ≥3 mg/L and LDL-C ≥2.6 mmol/L), RIR (hs-CRP ≥3 mg/L and LDL-C <2.6 mmol/L), residual cholesterol risk (RCR, hs-CRP <3 mg/L and LDL-C ≥2.6 mmol/L), and no residual risk (NRR, hs-CRP <3 mg/L and LDL-C <2.6 mmol/L). Vulnerable plaque features on HRMRI included positive remodeling, diffuse distribution, intraplaque hemorrhage, and strong enhancement.
Results:
Among 336 included patients, 21, 60, 58, and 197 were assigned to the RCIR, RIR, RCR, and NRR groups, respectively. Patients with RCIR (adjusted odds ratio [aOR], 3.606; 95% confidence interval [CI], 1.346–9.662; P=0.011) and RIR (aOR, 3.361; 95% CI, 1.774–6.368, P<0.001) had higher risks of strong enhancement than those with NRR. Additionally, patients with RCIR (aOR, 2.965; 95% CI, 1.060–8.297; P=0.038) were more likely to have intraplaque hemorrhage compared with those with NRR. In the sensitivity analysis, RCR (aOR, 2.595; 95% CI, 1.201–5.608; P=0.015) exhibited an additional correlation with an increased risk of intraplaque hemorrhage.
Conclusion
In patients with symptomatic ICAS, RIR is associated with a higher risk of intraplaque hemorrhage and strong enhancement, indicating an increased vulnerability to atherosclerotic plaques.
7.Body Composition Profiles and Associated Factors in Adolescents UndergoingLong-term Regular Exercise
Yutong WANG ; Xiaoyuan GUO ; Hanze DU ; Hui PAN ; Wei WANG ; Mei ZHANG ; Bo BAN ; Ping LI ; Xinran ZHANG ; Qiuping ZHANG ; Hongshuang SUN ; Rong LI ; Shi CHEN
Medical Journal of Peking Union Medical College Hospital 2025;16(3):591-597
To investigate body composition and associated factors in adolescents undergoing long-term regular sports training. This prospective longitudinal cohort study employed convenience sampling to recruit adolescents receiving structured athletic training at Jining Sports Training Center in June 2023. Baseline measurements included height, weight, body mass index (BMI), blood pressure, heart rate, waist circumference, and hip circumference. Questionnaires assessed sleep duration, screen time, and household income. Follow-up measurements in June 2024 repeated these assessments while adding bioelectrical impedance analysis for body composition (lean mass, skeletal muscle mass, fat mass, and body fat percentage). Linear regression models examined associations between training type (direct-contact vs. non-contact sports) and follow-up body fat percentage, BMI, and waist circumference as dependent variables, adjusting for covariates. The study included 110 adolescents (39 female, 71 male) with median age 13.21 years (IQR: 12.46-14.33). Participants comprised 65 direct-contact and 45 non-contact athletes. Baseline prevalence rates were 27.27% for overweight/obesity, 24.55% for elevated waist circumference, and 16.36% for elevated blood pressure. At follow-up, corresponding rates were 24.55%, 26.36%, and 13.64% respectively. The elevated blood pressure subgroup showed significantly higher waist circumference ( Despite regular athletic training, substantial proportions of adolescents exhibited overweight/obesity, abdominal obesity, and elevated blood pressure, warranting clinical attention. Training modality appears to influence body composition changes, with direct-contact sports associated with more favorable adiposity-related outcomes.
8.Quality control protocol for adult overweight and obesity screening in health management (examination) institutions (2025 edition)
Jianling FAN ; Tiejun WANG ; Pengfei YANG ; Keke DING ; Xiaoning HAO ; Sunfang JIANG ; Ankang LÜ ; Jianping LU ; Sheng RONG ; Weibin SHI ; Shengwei SUN ; Yan TAN ; Qilei TU ; Zhiping WANG ; Bing WANG ; Jianyun WANG ; Weijian WANG ; Yan WANG ; Qun XU ; Chenli ZHANG ; Fan ZHANG ; Ping ZHANG ; Yansong ZHENG ; Jieru ZHOU ; Dan CHEN ; Jiaoyang ZHENG
Chinese Journal of Clinical Medicine 2025;32(6):1097-1111
Obesity, as a chronic recurrent disease, has become a major public health challenge in China. To implement the requirements of the Healthy China Initiative (2019—2030), under domestic guidelines or consensus statements on overweight and obesity, and in alignment with the latest scientific advances globally, the Quality control protocol for adult overweight and obesity screening in health management (examination) institutions (2025 edition) was developed. This protocol was drafted by the Health Management Center of Shanghai Changzheng Hospital and formulated through multiple rounds of deliberation by experts in China’s health examination quality control field. The protocol establishes unified standards for screening facilities, personnel qualifications, and measurement or testing procedures. It defines specific screening items, outlines a standardized screening pathway, and sets requirements for the final medical review, ensuring the scientific validity, effectiveness, and safety of the screening process. The implementation of this protocol will enhance the consistency of weight management practices for adults across health examination institutions and strengthen the quality control of overweight and obesity screening programs.
9.Application of 3D-HRAM model in diagnosis and localization of anal sphincter injury after surgery for complex anal fistula
Xuxiong WU ; Limei XU ; Juan HUANG ; Yaling YANG ; Zhaochu WANG ; Ruiwen LIANG ; Rong SHI
Journal of Chongqing Medical University 2025;50(6):821-827
Objective:To explore the application value of three-dimensional high-resolution anorectal manometry(3D-HRAM)model in the diagnosis and localization of anal sphincter injury after surgery for complex anal fistula.Methods:A prospective study was con-ducted on 92 patients who had undergone surgery for complex anal fistula in the Department of Coloproctology of The People's Hospi-tal Affiliated to Fujian University of Traditional Chinese Medicine from January 2023 to January 2024.The study was conducted in two stages.In the first stage,92 patients underwent 3D-HRAM and endoanal ultrasonography(EAUS)to examine the sphincter,and the data were compared with intraoperative records to evaluate the diagnostic efficiency and localization accuracy of 3D-HRAM and EAUS.In the second stage,92 patients who had been examined were grouped according to the presence or absence of symptoms of anal dysfunction to further verify the diagnostic and localization values of 3D-HRAM and EAUS for postoperative compensated/decompen-sated sphincter injury.Results:Among 92 patients,41 and 57 patients were diagnosed with sphincter injury through 3D-HRAM and EAUS,with a sensitivity of 61.19%and 85.07%,a specificity of 88%and 76%,an area under the curve of 0.739 and 0.813 calcu-lated by plotting the receiver operating characteristic curve,and a localization accuracy of 44.77%and 71.64%,respectively,showing significant differences between 3D-HRAM and EAUS(P=0.002),indicating that 3D-HRAM had lower diagnostic efficiency and local-ization accuracy than EAUS for anal sphincter injury after surgery for complex anal fistula.After grouping by symptoms,the diagnostic efficiency and localization accuracy of 3D-HRAM for symptomatic sphincter injury(decompensated)were significantly better than those for asymptomatic sphincter injury,and were similar to those of EAUS(P=0.763).Conclusion:The application advantage of 3D-HRAM lies in the diagnosis and localization of decompensated anal sphincter injury after surgery for complex anal fistula,which provides effective technical support for the study of anal defecation control mechanisms and injury compensation mechanisms.
10.Study on Zinc Oxide/Ferrous Sulfide Heterojunction Ethanol Gas Sensor
Ji-Jin SHI ; Sen-Rong YE ; Jin-Peng LUO ; Chi ZHANG ; Xin HE ; Wei-Jia YANG
Chinese Journal of Analytical Chemistry 2025;53(3):375-386
Ethanol detection plays an important role in food industry,environmental monitoring,medical health monitoring,prevention of drunk driving,etc.The development of low-cost,high-performance ethanol sensors has important application value.In this study,a ZnO/FeS nano heterojunction ethanol sensor was prepared on commercial ceramic silver electrode substrate.The sensing characteristics of the sensor for ethanol gas were systematically studied.The results showed that ZnO had a nanowire structure,and the FeS was coated on the ZnO nanowire in the form of nanosheets.The sensor performed well for ethanol detection in environments with relative humidity ranging from 30%to 60%,with a detection range from 0.2 mg/m3 to 50 mg/m3.At the optimum operating temperature of 300℃,the response of ZnO/FeS nano heterojunction sensor to 50 mg/m3 ethanol was 15.6,the response time was 5.0 s,and the detection limit was as low as 0.101 mg/m3,which was obviously better than that of commercial ethanol sensor.This sensor was highly selective for ethanol compared to other gases such as CO,NH3,acetone,etc,and could steadily work for 30 days.The fabricated sensor had good development potential in the field of low-cost and high-performance ethanol gas detection.

Result Analysis
Print
Save
E-mail