1.Association of Rapidly Elevated Plasma Tau Protein With Cognitive Decline in Patients With Amnestic Mild Cognitive Impairment and Alzheimer’s Disease
Che-Sheng CHU ; Yu-Kai LIN ; Chia-Lin TSAI ; Yueh-Feng SUNG ; Chia-Kuang TSAI ; Guan-Yu LIN ; Chien-An KO ; Yi LIU ; Chih-Sung LIANG ; Fu-Chi YANG
Psychiatry Investigation 2025;22(2):130-139
Objective:
Whether elevation in plasma levels of amyloid and tau protein biomarkers are better indicators of cognitive decline than higher baseline levels in patients with amnestic mild cognitive impairment (aMCI) and Alzheimer’s disease (AD) remains understudied.
Methods:
We included 67 participants with twice testing for AD-related plasma biomarkers via immunomagnetic reduction (IMR) assays (amyloid beta [Aβ]1-40, Aβ1-42, total tau [t-Tau], phosphorylated tau [p-Tau] 181, and alpha-synuclein [α-Syn]) and the Mini-Mental State Examination (MMSE) over a 1-year interval. We examined the correlation between biomarker levels (baseline vs. longitudinal change) and annual changes in the MMSE scores. Receiver operating characteristic curve analysis was conducted to compare the biomarkers.
Results:
After adjustment, faster cognitive decline was correlated with lower baseline levels of t-Tau (β=0.332, p=0.030) and p-Tau 181 (β=0.369, p=0.015) and rapid elevation of t-Tau (β=-0.330, p=0.030) and p-Tau 181 levels (β=-0.431, p=0.004). However, the levels (baseline and longitudinal changes) of Aβ1-40, Aβ1-42, and α-Syn were not correlated with cognitive decline. aMCI converters had lower baseline levels of p-Tau 181 (p=0.002) but larger annual changes (p=0.001) than aMCI non-converters. The change in p-Tau 181 levels showed better discriminatory capacity than the change in t-Tau levels in terms of identifying AD conversion in patients with aMCI, with an area under curve of 86.7% versus 72.2%.
Conclusion
We found changes in p-Tau 181 levels may be a suitable biomarker for identifying AD conversion.
2.Detection of liver ischemia sample signals using terahertz time-domain spectroscopy
Yiwei GUAN ; Shaohui GENG ; Zixuan SHU ; Han SHENG ; Huawei WANG ; Guangrui HUANG
Chinese Journal of Medical Physics 2025;42(11):1488-1493
Objective To explore the differences in terahertz(THz)signal characteristics between normal and ischemic liver tissues of New Zealand rabbits using THz time-domain spectroscopy(THz-TDS),thereby providing a novel detection technique for the pathological detection of liver tissues.Methods Liver ischemia models were established in New Zealand rabbits.The THz scanning signal maps of normal and ischemic liver tissues were obtained using a reflective THz-TDS system,and the acquired signals were subjected to principal component analysis.Results Both normal and ischemic liver tissues displayed two distinct peaks in their THz signals.However,the amplitude of the THz signal in ischemic liver tissue was higher than that in normal liver tissue,with significant differences also observed in their signal morphologies.Principal component analysis results revealed a clear clustered distribution between the signals of normal and ischemic liver tissues,indicating that THz-TDS could effectively distinguish between the two tissue types.Conclusion THz-TDS can be applied to the detection of ischemic liver tissue,providing experimental evidence to support further research on the early diagnosis of liver ischemia and exhibiting broad prospects for clinical application.
3.Troubleshooting of Siemens MOBILETT XP Digital bedside DR:Four case reports
Liang-yan HUANG ; Guan-you WU ; Rui HUANG ; Sheng-fu YANG ; Wei-wei LIN ; Wei-guang OU
Chinese Medical Equipment Journal 2025;46(3):118-120
Four cases of typical faults of Siemens MOBILETT XP Digital bedside DR were introduced.The causes for the problems were analyzed,and some countermeasures were put forward accordingly.References were provided for medical engineers to treat similar faults.[Chinese Medical Equipment Journal,2025,46(3):118-120]
4.Safety and efficacy of intrasaccular flow disruptor in intracranial aneurysms
Jifa LIU ; Yuanzhi LI ; Feng FAN ; Hang ZHANG ; Nan MA ; Zhen WANG ; Sheng GUAN
Chinese Journal of Neuromedicine 2025;24(3):230-234
Objective:To explore the safety and efficacy of intrasaccular flow disruptor in intracranial aneurysms, including wide-necked aneurysms.Methods:A retrospective analysis was performed; 102 patients with intracranial aneurysms treated with intrasaccular flow disruptor at Department of Neurointervention, First Affiliated Hospital of Zhengzhou University from August 2022 to November 2024 were enrolled; their clinical and imaging data were collected. The aneurysm characteristics and perioperative complications were summarized; aneurysm occlusion was evaluated by Woven EndoBridge occlusion scale (WOS) immediately after surgery and during the follow-up period.Results:Among the 102 aneurysms, 33 were anterior cerebral artery aneurysms, 40 were middle cerebral artery aneurysms, 17 were internal carotid artery aneurysms and 12 were basilar artery aneurysms; 73 aneurysms were regular intracranial saccular aneurysms and 29 were irregular saccular ones (17 of them with daughter sacs); 12 aneurysms were ruptured at acute phase. The surgical success rate was 100%: single intrasaccular flow disruptor was implanted into 95 patients, and stent-assisted or salvage treatments were given to 7 patients). Immediately after surgery, WOS grading A was noted in 5 patients, grading B in 7, grading C in 31, and grading D in 59. Two patients suffered severe perioperative complications and passed away: one patient died for ischemic complications that ensued after stent salvage treatment (parent artery being compressed by intrasaccular flow disruptor); the other patient died for hemorrhagic complications triggered by rupture of an initially unruptured aneurysm following intrasaccular flow disruptor implantation. Among them, 52 patients completed postoperative DSA follow-up, with a median follow-up of 205 (168, 292) days; WOS grading A was noted in 31 patients, grading B in 9, grading C in 8, and grading D in 4 at the last follow-up; the full occlusion rate was 92.3%, and no ischemic or hemorrhagic adverse events occurred.Conclusion:Intrasaccular flow disruptor shows high short-term safety and good efficacy in the treatment of intracranial aneurysms.
5.Efficacy and safety of intrasaccular flow disruptor in wide-necked intracranial aneurysms: a multicenter retrospective study
Xiaowen ZHANG ; Jing LI ; Xifeng LI ; Chuanzhi DUAN ; Aihua LIU ; Huaizhang SHI ; Haowen XU ; Nan MA ; Zhiqiang YAO ; Feng FAN ; Chao LIU ; Jinyi LI ; Hailong ZHONG ; Mengyan FAN ; Jiaxin WAN ; Rijin LIN ; Huixiang LIU ; Jiamei ZHANG ; Xin ZHANG ; Sheng GUAN
Chinese Journal of Neuromedicine 2025;24(1):16-22
Objective:To evaluate the efficacy and safety of intrasaccular flow disruptor in wide-necked intracranial aneurysms.Methods:One hundred and seventeen patients with wide-necked intracranial aneurysms treated with intrasaccular flow disruptor were collected from Department of Neurointervention (First Affiliated Hospital of Zhengzhou University), Department of Neurosurgery (Beijing Tiantan Hospital, Capital Medical University), Department of Cerebrovascular Surgery, Neurosurgery Center (Zhujiang Hospital, Southern Medical University), and Department of Neurosurgery (First Affiliated Hospital of Harbin Medical University) from August 2022 to March 2024. Raymond-Roy Occlusion Classification (RROC) was employed to evaluate aneurysm embolization immediately after procedure; cranial CT or MRI within 48 hours of embolization were performed to identify any new intracranial hemorrhage, subarachnoid hemorrhage, or new symptomatic cerebral infarction related to the intracranial aneurysms. Modified Rankin Scale (mRS) was used to assess the neurological function at discharge. Imaging follow-up and outpatient follow-up were performed at 6 months after embolization to evaluate the aneurysm occlusion degree and complications.Results:A total of 117 intrasaccular flow disruptors were implanted in 117 patients, with a technical success rate of 100%; 115 patients (98.3%) enjoyed successful one-time release of their disruptors, and 2 patients (1.7%) required retrieval and redirection of the disruptors before second successful attempt. Flow disruptor plus stent was performed in 13 patients (11.1%). Immediately after procedure, RROC grading I was noted in 3 patients, grading II in 51 patients and grading III in 63 patients. Cranial CT or MRI within 48 hours of embolization indicated no new intracranial hemorrhage, subarachnoid hemorrhage, or symptomatic cerebral infarction related to the intracranial aneurysms. All patients had mRS score of 0 at discharge. Eighty-three patients completed a 6-month follow-up (RROC grading I in 41 patients, grading II in 33 patients and grading III in 9 patients), without ischemic or hemorrhagic adverse events.Conclusion:The results of this study preliminarily suggest that intrasaccular flow disruptor is effective and safe in wide-necked intracranial aneurysms.
6.Neuroform Atlas stent-assisted coil embolization for middle cerebral artery bifurcation aneurysms: a multicenter retrospective study
Mengyan FAN ; Jing LI ; Chuanzhi DUAN ; Huaizhang SHI ; Aihua LIU ; Xiaochuan SUN ; Feng FAN ; Jinyi LI ; Chao LIU ; Haowen XU ; Linyu WANG ; Zhiqiang YAO ; Hailong ZHONG ; Xiaowen ZHANG ; Rijin LIN ; Jiaxin WAN ; Nan ZHANG ; Huixiang LIU ; Jiamei ZHANG ; Sheng GUAN
Chinese Journal of Neuromedicine 2025;24(2):141-146
Objective:To evaluate the efficacy and safety of Neuroform Atlas stent-assisted coil embolization in patients with middle cerebral artery bifurcation aneurysms.Methods:A retrospective analysis was performed; the clinical data of 46 patients with middle cerebral artery bifurcation aneurysms accepted Neuroform Atlas stent-assisted coil embolization in First Affiliated Hospital of Zhengzhou University, Beijing Tiantan Hospital Affiliated to Capital Medical University, First Affiliated Hospital of Harbin Medical University, Zhujiang Hospital of Southern Medical University and First Affiliated Hospital of Chongqing Medical University from January 2022 to March 2024 were collected. There were 28 ruptured aneurysms (60.87%) and 18 unruptured aneurysms (39.13%). Follow-up was performed for more than 3 months; Raymond-Roy grading was used to evaluate the aneurysm embolization immediately after embolization and during follow-up; perioperative hemorrhagic or ischemic complications were recorded; modified Rankin Scale (mRS) was used to evaluate the prognosis of the patients at discharge and during follow-up (mRS score≤2: good prognosis, and mRS score>2: poor prognosis).Results:Coil embolization was successful in all 46 patients. DSA immediately after embolization showed that 41 patients (89.13%) had completely occluded aneurysms (Raymond-Roy grading I), 2 patients (4.35%) had residual aneurysm neck (Raymond-Roy grading Ⅱ) and 3 patients (6.52%) had partially occluded aneurysms (Raymond-Roy grading Ⅲ). Perioperative complications occurred in 5 patients, including 2 with postoperative cerebral infarction, 1 with hydrocephalus, 1 with postoperative pneumonia leading to respiratory failure, and 1 with stent thrombosis during embolization. Both at discharge and 3 months after embolization, 43 patients (93.48%) had good prognosis and 3 patients (6.52%) had poor prognosis. No obvious ischemic complications (such as stent restenosis) or hemorrhagic complications (such as re-rupture of the aneurysms) were found in all patients. Thirty patients (65.22%) had imaging follow-up for 6-12 months: 26 (86.67%) had Raymond-Roy grading I, 3 (10.00%) had Raymond-Roy grading II, and 1 (3.33%) had Raymond-Roy grading III.Conclusion:Neuroform Atlas stent-assisted coil embolization has good short-term efficacy and high safety in middle cerebral artery bifurcation aneurysms, but long-term follow-up observation is still needed to verify its efficacy.
7.Impact of flow diverter malapposition at the aneurysm neck on clinical outcomes and complications of intracranial aneurysms
Jie YANG ; Shuhai LONG ; Shuailong SHI ; Yukun HOU ; Ji MA ; Ye WANG ; Sheng GUAN ; Tengfei LI
Chinese Journal of Neuromedicine 2025;24(6):599-608
Objective:To investigate the impact of flow diverter (FD) malapposition at the aneurysm neck on clinical outcomes and complications of intracranial aneurysms, and identify the influencing factors for intraoperative FD malapposition.Methods:A retrospective study was performed; 153 patients with unruptured saccular aneurysms at the C4-C7 segments of the internal carotid artery accepted single FD implantation at Department of Interventional Radiology, First Affiliated Hospital of Zhengzhou University from June 2022 to March 2024 were chosen. Intraoperative high-resolution C-arm CT was utilized to assess FD apposition at the aneurysm neck. (1) Based on FD apposition at the aneurysm neck as shown, these 153 patients were divided into a malapposition group ( n=23, including 16 patients with malapposition being identified as residual malapposition after intraoperative corrective measures such as microwire massage and 7 patients with malapposition being newly detected in this study) and a complete apposition group ( n=130). Perioperative and follow-up complications were recorded. Clinical outcomes were assessed using modified Rankin Scale (mRS) at the final follow-up (mRS score of 0-2 as favorable outcome), and angiographic outcomes were evaluated by DSA at the final follow-up. Differences in clinical and angiographic outcomes and complication rate were compared between the malapposition group and complete apposition group. (2) Based on FD apposition at the aneurysm neck as shown, these 153 patients were divided into an intraoperative malapposition group ( n=74, including 67 patients with malapposition being detected during surgery and 7 patients with malapposition being newly detected in this study) and an intraoperative complete apposition group ( n=79). Univariate analysis was performed to compare the clinical variables between the intraoperative malapposition group and intraoperative complete apposition group; multivariate Logistic regression was further employed to identify the independent influencing factors for FD malapposition at the aneurysm neck. Results:(1) Four patients (all from the malapposition group) developed perioperative acute in-stent thrombosis. Nine patients experienced ischemic or hemorrhagic stroke during the follow-up, including 6 from the malapposition group and 3 from the complete apposition group; the complication rate in the malapposition group (6/23, 26.1%) was significantly higher than that in the complete apposition group (3/130, 2.3%) during the follow-up ( P<0.05). At the final follow-up, 2 patients (both from the malapposition group) had poor clinical outcome, while the remaining 151 patients had favorable outcome. Proportion of patients with favorable outcome between the two groups was statistically different (91.3%[21/23] vs. 100.0%[130/130], P<0.05). Delayed occlusion was detected in 46 patients (12 from the malapposition group and 34 from the complete apposition group) at the final angiographic follow-up. FD restenosis/re-occlusion was noted in 10 patients, including 6 from the malapposition group and 4 from the complete apposition group. Significant difference in delayed occlusion rate (52.2%[12/23] vs. 26.2%[34/130]) and long-term in-stent stenosis/occlusion rate (26.1%[6/23] vs. 3.1%[4/130]) was observed between the two groups ( P<0.05). (2) Significant difference in aneurysm neck diameter, FD angulation, parent artery stenosis, parent artery diameter ratio>1.2, and presence of branching vessels at the FD implantation site was noted between the intraoperative complete apposition group and intraoperative malapposition group ( P<0.05). Multivariate Logistic regression indicated that aneurysm neck diameter ( OR=1.431, 95% CI: 1.096-1.868, P=0.008), parent artery diameter ratio>1.2 ( OR=2.199, 95% CI: 1.083-4.463, P=0.029), and FD angulation ( OR=1.019, 95% CI: 1.002-1.036, P=0.027) were independent influencing factors for FD malapposition at the aneurysm neck. Conclusion:In FD implantation for intracranial aneurysms, FD malapposition at the aneurysm neck adversely affects delayed occlusion rate and complication rate; aneurysms with wider aneurysm neck diameter, parent artery diameter ratio>1.2, and greater FD angulation are trend to have FD malapposition at the aneurysm neck.
8.Clinical analysis of 6 patients with persistent proatlantal intersegmental artery
Panxing LI ; Tao QUAN ; Zhiqiang YAO ; Haowen XU ; Sheng GUAN
Chinese Journal of Neuromedicine 2025;24(9):928-932
Objective:Persistent proatlantal intersegmental artery (PPIA) is a rare variant of persistent carotid-vertebrobasilar anastomoses and mostly discovered incidentally. To explore the clinical features of PPIA, and enhance the understanding of this rare cerebrovascular variation.Methods:A retrospective analysis was performed. The clinical data of 6 patients with PPIA admitted to Department of Neurointervention, First Affiliated Hospital of Zhengzhou University from June 2018 to June 2024 were analyzed. The imaging features, associated cerebrovascular diseases, treatments and follow-up results were summarized.Results:Among the 6 PPIA patients, 4 were with type I and 2 were with type II; 5 were with left PPIA and 1 patient was with right PPIA; 5 patients had bilateral vertebral artery hypoplasia or absence, and 1 patient had absence of the ipsilateral vertebral artery and normal development of the contralateral vertebral artery. Four PPIA patients were combined with intracranial aneurysms: 2 patients received dual stent-assisted embolization and flow diverter device combined with covered stent implantation, respectively (after 6 months of follow-up, modified Rankin scale score of 0 indicating good prognosis and healed intracranial aneurysms), and the other 2 patients with micro-aneurysms were not treated. One patient was combined with internal carotid artery stenosis and accepted stent placement (good prognosis at 6 months after follow-up). One patient was combined with acute basilar artery tip occlusion and accepted aspiration thrombectomy (died of brain herniation 7 days after thrombectomy).Conclusions:PPIA is often accompanied by vertebral artery developmental abnormalities and prone to have concurrent intracranial aneurysms or ischemic stroke. When performing surgical treatment for cerebrovascular diseases associated with PPIA, PPIA protection to ensure blood supply of the posterior circulation is essential.
9.Troubleshooting of Siemens MOBILETT XP Digital bedside DR:Four case reports
Liang-yan HUANG ; Guan-you WU ; Rui HUANG ; Sheng-fu YANG ; Wei-wei LIN ; Wei-guang OU
Chinese Medical Equipment Journal 2025;46(3):118-120
Four cases of typical faults of Siemens MOBILETT XP Digital bedside DR were introduced.The causes for the problems were analyzed,and some countermeasures were put forward accordingly.References were provided for medical engineers to treat similar faults.[Chinese Medical Equipment Journal,2025,46(3):118-120]
10.Association of Rapidly Elevated Plasma Tau Protein With Cognitive Decline in Patients With Amnestic Mild Cognitive Impairment and Alzheimer’s Disease
Che-Sheng CHU ; Yu-Kai LIN ; Chia-Lin TSAI ; Yueh-Feng SUNG ; Chia-Kuang TSAI ; Guan-Yu LIN ; Chien-An KO ; Yi LIU ; Chih-Sung LIANG ; Fu-Chi YANG
Psychiatry Investigation 2025;22(2):130-139
Objective:
Whether elevation in plasma levels of amyloid and tau protein biomarkers are better indicators of cognitive decline than higher baseline levels in patients with amnestic mild cognitive impairment (aMCI) and Alzheimer’s disease (AD) remains understudied.
Methods:
We included 67 participants with twice testing for AD-related plasma biomarkers via immunomagnetic reduction (IMR) assays (amyloid beta [Aβ]1-40, Aβ1-42, total tau [t-Tau], phosphorylated tau [p-Tau] 181, and alpha-synuclein [α-Syn]) and the Mini-Mental State Examination (MMSE) over a 1-year interval. We examined the correlation between biomarker levels (baseline vs. longitudinal change) and annual changes in the MMSE scores. Receiver operating characteristic curve analysis was conducted to compare the biomarkers.
Results:
After adjustment, faster cognitive decline was correlated with lower baseline levels of t-Tau (β=0.332, p=0.030) and p-Tau 181 (β=0.369, p=0.015) and rapid elevation of t-Tau (β=-0.330, p=0.030) and p-Tau 181 levels (β=-0.431, p=0.004). However, the levels (baseline and longitudinal changes) of Aβ1-40, Aβ1-42, and α-Syn were not correlated with cognitive decline. aMCI converters had lower baseline levels of p-Tau 181 (p=0.002) but larger annual changes (p=0.001) than aMCI non-converters. The change in p-Tau 181 levels showed better discriminatory capacity than the change in t-Tau levels in terms of identifying AD conversion in patients with aMCI, with an area under curve of 86.7% versus 72.2%.
Conclusion
We found changes in p-Tau 181 levels may be a suitable biomarker for identifying AD conversion.

Result Analysis
Print
Save
E-mail