1.Feasibility of optimizing radiation dose for three-dimensional printing of the maxillofacial bone based on low-dose CT technology
Guan LI ; Haopeng WANG ; Jinbao WANG ; Xinhao SONG ; Guochu QIN ; Yang SHAO
Chinese Journal of Tissue Engineering Research 2026;30(6):1384-1389
BACKGROUND:Maxillofacial bone three-dimensional(3D)printing technology has been widely used in clinical diagnosis and treatment,but the data source before performing maxillofacial bone 3D printing mainly comes from the CT scanning data.The lens,thyroid and other parts of the human body are extremely sensitive to X-rays;therefore,it is particularly important to effectively reduce the dose of CT radiation when acquiring the data source.OBJECTIVE:To explore the feasibility of low-dose CT technology in optimizing radiation dose for maxillofacial bone 3D printing.METHODS:The medical records of 65 patients who underwent maxillofacial bone 3D printing in the Department of Stomatology at the General Hospital of Northern Theater Command from March 2021 to December 2023 were retrospectively collected and categorized into a conventional CT-dose 3D printing group(conventional CT-dose,120 kVp,automated tube current modulation,n=32)and a low-CT-dose 3D printing group(low-CT-dose group,80 kVp,automated tube current modulation,n=33).The effective dose of radiation was calculated and compared between the two groups.A Likert scale was used to evaluate the quality of 3D printing in the two groups,and the measurement bias and consistency between evaluators were measured using the Bland-Altman method.RESULTS AND CONCLUSION:(1)There was no significant difference in the general demographic characteristics(age,height,weight,body mass,sex,and body mass index)between the two groups(all P>0.05).(2)The effective dose value of the low CT-dose 3D printing group was(0.3±0.1)mSv,which was about 62.5%lower than that in the conventional CT-dose 3D printing group[(0.8±0.1)mSv].(3)There was no significant difference in the subjective scoring of 3D printing quality between the two groups(all P>0.05).The subjective consistency among evaluators was good,with Kappa values of 0.85,0.80,and 0.76.The scatter points in the Bland-Altman for both protocols were uniformly distributed within the standard deviation line,indicating good consistency between the two groups.To conclude,low-dose CT technology can be effectively applied in maxillofacial bone 3D printing,reducing radiation dose without affecting the quality of 3D printing.
2.Feasibility of optimizing radiation dose for three-dimensional printing of the maxillofacial bone based on low-dose CT technology
Guan LI ; Haopeng WANG ; Jinbao WANG ; Xinhao SONG ; Guochu QIN ; Yang SHAO
Chinese Journal of Tissue Engineering Research 2026;30(6):1384-1389
BACKGROUND:Maxillofacial bone three-dimensional(3D)printing technology has been widely used in clinical diagnosis and treatment,but the data source before performing maxillofacial bone 3D printing mainly comes from the CT scanning data.The lens,thyroid and other parts of the human body are extremely sensitive to X-rays;therefore,it is particularly important to effectively reduce the dose of CT radiation when acquiring the data source.OBJECTIVE:To explore the feasibility of low-dose CT technology in optimizing radiation dose for maxillofacial bone 3D printing.METHODS:The medical records of 65 patients who underwent maxillofacial bone 3D printing in the Department of Stomatology at the General Hospital of Northern Theater Command from March 2021 to December 2023 were retrospectively collected and categorized into a conventional CT-dose 3D printing group(conventional CT-dose,120 kVp,automated tube current modulation,n=32)and a low-CT-dose 3D printing group(low-CT-dose group,80 kVp,automated tube current modulation,n=33).The effective dose of radiation was calculated and compared between the two groups.A Likert scale was used to evaluate the quality of 3D printing in the two groups,and the measurement bias and consistency between evaluators were measured using the Bland-Altman method.RESULTS AND CONCLUSION:(1)There was no significant difference in the general demographic characteristics(age,height,weight,body mass,sex,and body mass index)between the two groups(all P>0.05).(2)The effective dose value of the low CT-dose 3D printing group was(0.3±0.1)mSv,which was about 62.5%lower than that in the conventional CT-dose 3D printing group[(0.8±0.1)mSv].(3)There was no significant difference in the subjective scoring of 3D printing quality between the two groups(all P>0.05).The subjective consistency among evaluators was good,with Kappa values of 0.85,0.80,and 0.76.The scatter points in the Bland-Altman for both protocols were uniformly distributed within the standard deviation line,indicating good consistency between the two groups.To conclude,low-dose CT technology can be effectively applied in maxillofacial bone 3D printing,reducing radiation dose without affecting the quality of 3D printing.
3.Comparative Analysis of Clinical Efficacy of Traditional Chinese Medicine Manipulative Reduction Combined with Small Splint Fixation Versus Surgical Treatment for Type A Distal Radius Fracture
Yang SHAO ; Zihan WANG ; Jianwei WANG ; Guoda DAI ; Hengyan CUI ; Zhen HUA ; Tingchen ZHU ; Shaoshuo LI ; Jun MAO ; Fenghua CHEN ; Shuai TAO ; Mao WU
Journal of Traditional Chinese Medicine 2026;67(10):1078-1085
ObjectiveTo compare the clinical efficacy of traditional Chinese medicine (TCM) manipulative reduction combined with small splint fixation versus surgical treatment for type A distal radius fracture (DRF) and to explore the factors influencing the choice of treatment. MethodsA multi-center retrospective study was conducted, collecting data from 1237 type A DRF patients treated in 11 hospitals in Jiangsu province from September, 2023 to April, 2025. Among them, 851 patients in the TCM group received manipulative reduction combined with small splint fixation, and 386 patients in the surgical group underwent open reduction and internal fixation. Visual analog scale (VAS) scores for pain and radiographic indicators including palmar tilt, ulnar deviation, and radial height were compared before treatment, 5-7 days after treatment, and 4-6 weeks after treatment. The wrist joint function scores including Dienst and Gartland-Werley scores at 12 weeks after treatment were recorded. Subgroup analysis was conducted for the excellent rate of Dienst and Gartland-Werley scores, stratified by age (<50, 50-59, 60-69, ≥70 years old) and AO subtypes (A1, A2, A3). A multivariate logistic regression model was used to identify independent factors influencing treatment choice. ResultsOn 5-7 days after treatment, the surgical group had lower VAS scores than the TCM group, while 4-6 weeks after treatment, the TCM group showed lower VAS scores than the surgical group (P<0.01). In terms of radiographic indicators, except for the palmar tilt before treatment being higher in the surgical group than in the TCM group (P<0.01), there were no significant differences in palmar tilt, ulnar deviation, and radial height at other timepoints (P>0.05). Twelve weeks after treatment, the surgical group had a higher average Gartland-Werley score and the excellent rate than the TCM group (P<0.01). Subgroup analysis showed that in patients with A2 type DRF aged 50-59 and 60-69 years old, the excellent rates of Dienst and Gartland-Werley scores in the TCM group were higher than those in the surgical group (P<0.05). Multivariate logistic regression analysis revealed that age, palmar tilt, ulnar deviation, and the degree of swelling on the affected side were independent factors influencing the choice of treatment (P<0.05). ConclusionBoth TCM manipulative reduction combined with small splint fixation and surgical treatment for type A DRF can achieve good therapeutic effects. TCM manipulative reduction combined with small splint fixation has certain advantages in medium- and long-term pain relief, especially in elderly patients, where wrist joint function recovery is more stable. Age, palmar tilt, ulnar deviation, and swelling degree are the main factors influencing the treatment choice.
4.Clinical Efficacy and Radiographic Outcomes of Manipulative Reduction Combined with Small Splint Fixation for Distal Radius Fractures:A Retrospective Multicenter Study with Propensity Score Matching
Mao WU ; Guoda DAI ; Yang SHAO ; Shaoshuo LI ; Zhen HUA ; Hengyan CUI ; Tingchen ZHU ; Dipeng LI ; Jintao LIU ; Ming ZHOU ; Peimin WANG ; Liyong ZHANG ; Jianwei WANG
Journal of Traditional Chinese Medicine 2026;67(10):1086-1092
ObjectiveTo observe the clinical efficacy and radiographic outcomes of manipulative reduction combined with small splint fixation in the treatment of distal radius fractures. MethodsThe clinical data of 1051 patients with distal radius fractures were retrospectively collected from five hospitals included in the Jiangsu Diagnosis and Treatment Data Platform for Traditional Chinese Medicine(TCM) Dominant Diseases. Propensity score matching at a 1∶4 ratio was applied, resulting in 580 cases selected for final analysis, which comprised 448 patients in the TCM group(manipulative reduction plus small splint fixation) and 132 in the surgical treatment group(open reduction and internal fixation). Each group was further stratified into type A, B, and C subgroups based on AO fracture classification. Radiographic indicators including palmar tilt, radial inclination, and radial height were compared between groups before treatment and 1 day, 1 week, and 4-6 weeks after treatment, and pain visual analog scale(VAS) scores before treatment and 1 week and 4-6 weeks after treatment were also compared. Wrist joint function was assessed 12 weeks after treatment, using the Dienst wrist function score and the Gartland and Werley(G-W) wrist function score. Additionally, the radiographic indicators at different timepoints and the 12-week wrist function levels were compared between groups across different fracture types. ResultsNo statistically significant difference was observed in radiographic indicators and VAS scores at all timepoints before and after treatment, as well as wrist joint function grades assessed by the Dienst score and the G-W score at 12 weeks after treatment (P>0.05). Compared to those before treatment, both groups showed increased palmar tilt, radial inclination, and radial height 1 week and 4-6 weeks after treatment, and decreased VAS scores (P<0.05). Compared to those 1 week after treatment, both groups showed a decrease in palmar tilt, an increase in radial inclination and radial height, and a reduction in VAS score 4-6 weeks after treatment(P<0.05). In type A and B subgroups, the surgical treatment group had a higher radial inclination than the TCM group 4-6 weeks after treatment, while in the type C subgroup, a higher radial height was shown in the surgical treatment group than in the TCM group 4-6 weeks after treatment(P<0.05). In type C subgroup, there was significant difference between groups in the wrist joint function by G-W scores 12 weeks after treatment(P<0.05). ConclusionManipulative reduction combined with small splint fixation can maintain fracture alignment and alleviate pain in treating distal radius fractures, which achieves therapeutic outcomes comparable to surgical treatment. It is particularly suitable for type A and B fractures and can be considered an effective treatment option for distal radius fractures.
5.Construction and Clinical Validation of a Deep Learning-Based Automatic Measurement Model for Palmar Tilt and Radial Inclination in Distal Radius Fractures
Guoda DAI ; Jianwei WANG ; Mao WU ; Bin KANG ; Yang SHAO ; Hengyan CUI ; Shaoshuo LI ; Tingchen ZHU ; Zhen HUA ; Zhongming SHEN ; Jintao LIU ; Ming ZHOU
Journal of Traditional Chinese Medicine 2026;67(10):1093-1100
ObjectiveTo construct an automatic measurement model for palmar tilt and radial inclination suitable for traditional Chinese medicine (TCM) clinical scenarios, and to validate its accuracy and efficiency in TCM manipulative reduction settings. MethodsData on anteroposterior (AP) and lateral X-rays of distal radius fractures were collected from patients admitted to 18 TCM/ integrated TCM and western medicine hospitals in Jiangsu province between September 1st, 2023, and September 1st, 2024, via the Jiangsu Diagnosis and Treatment Big Data Platform for TCM Dominant Diseases. A medical image segmentation framework based on multi-scale feature fusion and edge-awareness was employed, combined with anatomical knowledge specific to TCM orthopedics, to optimize the feature extraction strategy of an artificial intelligence (AI) model. This framework enabled automatic segmentation of fracture regions and measurement of distal radius palmar tilt and radial inclination. The accuracy of the AI model in measuring radial inclination and volar tilt was validated, and the measurement time and average time gain rate of the AI model were compared to those of manual measurement. ResultsA total of 15,444 AP and lateral X-ray images of distal radius fractures were collected, and were divided into a training set (11,144 images, 5066 AP and 6078 lateral), a validation set (3700 images, 1840 AP and 1860 lateral), and an independent test set (600 images, 300 AP and 300 lateral) after preprocessing. In the measurement of 300 AP X-rays in the independent test set for radial inclination, when the degree error between AI measurement and manual measurement was <3° and <5°, AI measurement accuracy was 83% and 93%, respectively. In 300 lateral X-rays in the test set for palmar tilt, when AI measurements had an error of <3° and <5° compared to manual measurements, corresponding accuracy rate was 78% and 90%, respectively. For 50 X-ray images, AI measurement time was (1.37±0.05) min for radial inclination while manual measurement time was (22.57±2.52) min (P<0.001); in terms of palmar tilt, the AI measurement time was (1.33±0.14) min, shorter than (23.70±2.80) min for manual measurement time (P<0.001). Average time gain rates for manual and AI measurements were 93.93% and 94.39% respectively. ConclusionAn automatic measurement model for palmar tilt and radial inclination in distal radius fractures has been established, enabling more accurate and efficient assessment as well as providing a tool to support the quantitative evaluation of the efficacy of TCM manipulative reduction and large-sample clinical research.
6.Expert consensus on precise intervention with repetitive transcranial magnetic stimulation for sleep disorders in the elderly
Yuan SHAO ; Jian WANG ; Wei LIANG ; Yingli ZHANG ; Gangqiang HOU ; Xia LI ; Yi XING ; Lu WANG ; Shi TANG ; Yongjun WANG
Sichuan Mental Health 2026;39(2):97-105
In recent years, repetitive transcranial magnetic stimulation (rTMS) has garnered significant attention as a therapeutic approach for sleep disorders in the elderly. However, the prevailing rTMS protocols are predominantly developed based on normative neurophysiological data derived from young adults and fail to incorporate individualized parameters tailored to the brain characteristics of the elderly. To address this gap, the consensus development group synthesized the latest evidence from 2010 to 2025 and established a standardized rTMS protocol specifically for elderly patients with sleep disorders. Adhering to the Appraisal of Guidelines for Research and Evaluation II (AGREE II) framework, systematically screened randomized controlled trials (RCTs) and systematic reviews regarding rTMS in the treatment of sleep disorders across various conditions. Meanwhile, the Grading of Recommendations Assessment, Development and Evaluation (GRADE) system was employed to rigorously grade the quality of evidence and the strength of recommendations. This consensus guideline delineates precise rTMS protocols for the management of sleep disorders in the elderly, highlights the adjustment of stimulation intensity according to scalp-cortex distance recommends either MRI‑guided neuronavigation or the Beam F3/F4 heuristic approach for accurate target localization, thereby providing precise rTMS intervention protocol for sleep disorders in the elderly, aiming to enhance clinical efficacy while ensuring treatment safety. [Funded by National Key Research and Development Program (number, 2023YFC3603200); General Program of Shenzhen Science and Technology Innovation Commission (number, JCYJ20240813112859008, JCYJ20240813112900002); Youth Program of Shenzhen Kangning Hospital (number, KN2023A004); www.guidelines-registry.cn number, PREPARE-2026CN530]
7.Advancements in Gas-releasing Micro/Nanoplatforms for Overcoming MDR Bacterial Infections in Diabetic Wounds
Ruo-Can LIU ; Yu-Qian WANG ; Shuai ZHANG ; Shao-Zhi ZUO ; Yun-Di WU ; Xi-Long WU
Progress in Biochemistry and Biophysics 2026;53(5):1356-1375
Chronic diabetic wounds, severely complicated by multidrug-resistant (MDR) bacterial infections, represent a profound and escalating global health crisis. The intrinsically hostile microenvironment of diabetic wounds, characterized by localized hypoxia, persistent oxidative stress, and poor vascularization, creates an ideal niche for opportunistic pathogens such as Staphylococcus aureus and Pseudomonas aeruginosa. These bacteria readily construct dense extracellular polymeric substance (EPS) biofilms, which not only physically shield the microbes from host immune responses but also actively trap the wound in a state of chronic, unresolved inflammation. Consequently, conventional systemic and topical antibiotic therapies are becoming increasingly futile, as poor perfusion at the wound site restricts drug bioavailability, while the rapid genetic evolution of bacteria and the impenetrable nature of biofilms lead to catastrophic treatment failures, often culminating in severe tissue necrosis and lower-extremity amputations. To circumvent the limitations of traditional antimicrobials, therapeutic gas delivery has emerged as a highly promising, paradigm-shifting strategy. Gaseous signaling molecules, particularly nitric oxide (NO), carbon monoxide (CO), hydrogen sulfide (H2S), and hydrogen (H2), possess unique physicochemical properties that allow them to seamlessly penetrate dense biofilm matrices and cellular membranes. Once inside, these gases operate via multi-targeted mechanisms that are incredibly difficult for bacteria to develop resistance against; for instance, NO induces severe lipid peroxidation and DNA cleavage in bacteria, CO downregulates pro-inflammatory cytokines, H2S significantly accelerates endothelial cell migration for neovascularization, and H2 acts as a powerful selective antioxidant to neutralize tissue-damaging reactive oxygen species (ROS). Together, these therapeutic gases not only exert broad-spectrum bactericidal effects but also actively reprogram the wound bed by promoting the critical M1-to-M2 macrophage polarization and stimulating angiogenesis. Despite their immense biological potential, the direct clinical translation of gas therapies is severely hindered by inherent physicochemical drawbacks, including extreme volatility, short physiological half-lives, poor aqueous solubility, and the high risk of off-target systemic toxicity, if applied indiscriminately. To conquer these immense pharmacokinetic barriers, cutting-edge advancements in materials science have driven the development of gas-releasing micro- and nanoplatforms. Utilizing sophisticated carriers such as metal-organic frameworks (MOFs), mesoporous silica, polymeric nanoparticles, liposomes, and injectable hydrogels, researchers can now encapsulate gas-donor molecules to achieve sustained, localized delivery. More importantly, these advanced nanoplatforms are ingeniously engineered to be stimuli-responsive. By exploiting the pathological hallmarks of the diabetic wound environment, such as elevated glucose concentrations, acidic pH, and overexpressed ROS, or by utilizing external triggers like near-infrared (NIR) light irradiation and ultrasound, these intelligent platforms ensure on-demand, precise spatio-temporal gas release. This often allows for powerful synergistic combinations, such as photothermal or photodynamic therapy coupled with gas release, thereby obliterating biofilms while sparing healthy tissue. While the therapeutic outcomes of these smart delivery systems in eradicating MDR infections and accelerating tissue repair are unprecedented, several critical challenges remain before widespread clinical adoption, as long-term biosafety profiles of the carrier nanomaterials, complexities in large-scale good manufacturing practice (GMP) production, and stringent regulatory hurdles must be rigorously addressed. Looking forward, the next frontier lies in the realm of precision medicine and theranostics, where future research must focus on the seamless integration of these gas-releasing platforms with flexible, wearable biosensors capable of continuously monitoring wound biomarkers (e.g., pH, temperature, uric acid) in real-time. Coupled with artificial intelligence algorithms to govern automated, closed-loop adaptive dosing, these next-generation smart dressings hold the ultimate potential to comprehensively transform the clinical management of complex, infected diabetic wounds.
8.Progress and Challenges of Transurethral Holmium Laser Therapy for Bladder Tumors
Yiqun SHAO ; Yongjun GUAN ; Zhenda WANG ; Zhong WANG
Cancer Research on Prevention and Treatment 2026;53(5):332-338
Bladder tumor is a common tumor in the urinary system, posing a serious threat to patients’ health and quality of life. The standard surgical method for non-muscle-invasive bladder cancer is the transurethral resection of bladder tumor. As a new type of minimally invasive treatment, transurethral holmium laser has shown unique advantages in the treatment of bladder tumors. This work introduces the epidemiological characteristics of bladder tumors and the limitations of traditional treatment methods and elaborates on the technical principles, development history of holmium laser and its application status in the treatment of bladder tumors. By analyzing clinical research data, it compares therapeutic effects between holmium laser and other treatment methods. It also presents the key points of surgical techniques, perioperative management strategies, and measures for the prevention and treatment of complications. This research discusses the current technical challenges and future development directions in holmium laser treatment, providing references for clinical practice and research.
9.Advancements in Gas-releasing Micro/Nanoplatforms for Overcoming MDR Bacterial Infections in Diabetic Wounds
Ruo-Can LIU ; Yu-Qian WANG ; Shuai ZHANG ; Shao-Zhi ZUO ; Yun-Di WU ; Xi-Long WU
Progress in Biochemistry and Biophysics 2026;53(5):1356-1375
Chronic diabetic wounds, severely complicated by multidrug-resistant (MDR) bacterial infections, represent a profound and escalating global health crisis. The intrinsically hostile microenvironment of diabetic wounds, characterized by localized hypoxia, persistent oxidative stress, and poor vascularization, creates an ideal niche for opportunistic pathogens such as Staphylococcus aureus and Pseudomonas aeruginosa. These bacteria readily construct dense extracellular polymeric substance (EPS) biofilms, which not only physically shield the microbes from host immune responses but also actively trap the wound in a state of chronic, unresolved inflammation. Consequently, conventional systemic and topical antibiotic therapies are becoming increasingly futile, as poor perfusion at the wound site restricts drug bioavailability, while the rapid genetic evolution of bacteria and the impenetrable nature of biofilms lead to catastrophic treatment failures, often culminating in severe tissue necrosis and lower-extremity amputations. To circumvent the limitations of traditional antimicrobials, therapeutic gas delivery has emerged as a highly promising, paradigm-shifting strategy. Gaseous signaling molecules, particularly nitric oxide (NO), carbon monoxide (CO), hydrogen sulfide (H2S), and hydrogen (H2), possess unique physicochemical properties that allow them to seamlessly penetrate dense biofilm matrices and cellular membranes. Once inside, these gases operate via multi-targeted mechanisms that are incredibly difficult for bacteria to develop resistance against; for instance, NO induces severe lipid peroxidation and DNA cleavage in bacteria, CO downregulates pro-inflammatory cytokines, H2S significantly accelerates endothelial cell migration for neovascularization, and H2 acts as a powerful selective antioxidant to neutralize tissue-damaging reactive oxygen species (ROS). Together, these therapeutic gases not only exert broad-spectrum bactericidal effects but also actively reprogram the wound bed by promoting the critical M1-to-M2 macrophage polarization and stimulating angiogenesis. Despite their immense biological potential, the direct clinical translation of gas therapies is severely hindered by inherent physicochemical drawbacks, including extreme volatility, short physiological half-lives, poor aqueous solubility, and the high risk of off-target systemic toxicity, if applied indiscriminately. To conquer these immense pharmacokinetic barriers, cutting-edge advancements in materials science have driven the development of gas-releasing micro- and nanoplatforms. Utilizing sophisticated carriers such as metal-organic frameworks (MOFs), mesoporous silica, polymeric nanoparticles, liposomes, and injectable hydrogels, researchers can now encapsulate gas-donor molecules to achieve sustained, localized delivery. More importantly, these advanced nanoplatforms are ingeniously engineered to be stimuli-responsive. By exploiting the pathological hallmarks of the diabetic wound environment, such as elevated glucose concentrations, acidic pH, and overexpressed ROS, or by utilizing external triggers like near-infrared (NIR) light irradiation and ultrasound, these intelligent platforms ensure on-demand, precise spatio-temporal gas release. This often allows for powerful synergistic combinations, such as photothermal or photodynamic therapy coupled with gas release, thereby obliterating biofilms while sparing healthy tissue. While the therapeutic outcomes of these smart delivery systems in eradicating MDR infections and accelerating tissue repair are unprecedented, several critical challenges remain before widespread clinical adoption, as long-term biosafety profiles of the carrier nanomaterials, complexities in large-scale good manufacturing practice (GMP) production, and stringent regulatory hurdles must be rigorously addressed. Looking forward, the next frontier lies in the realm of precision medicine and theranostics, where future research must focus on the seamless integration of these gas-releasing platforms with flexible, wearable biosensors capable of continuously monitoring wound biomarkers (e.g., pH, temperature, uric acid) in real-time. Coupled with artificial intelligence algorithms to govern automated, closed-loop adaptive dosing, these next-generation smart dressings hold the ultimate potential to comprehensively transform the clinical management of complex, infected diabetic wounds.
10.Construction on medication verification system based on the integration of image recognition and Raman spectros-copy
Min WANG ; Haitao LIU ; Zhuzhu PENG ; Shao LIU
China Pharmacy 2026;37(10):1341-1345
OBJECTIVE To construct a dual-verification system integrating image pre-screening and Raman spectroscopy for inpatient pharmacy unit-dose dispensing in response to the issue of recognition blind spots for drugs of “same appearance but different spectrum” by drug inspection machines. METHODS An image feature and Raman spectroscopy database, covering 296 oral medications, were established. Spectral matching was performed using a cosine similarity algorithm (decision threshold 0.95). A dual-verification system of “image pre-screening and Raman spectroscopy confirmation” was designed, and a self-controlled before-and-after study was conducted across 5 clinical wards. RESULTS The system achieved a mean recognition accuracy of 99.2% for all medications in the database, with 100% accurate identification of representative “same-appearance but different-spectrum” drugs. The average verification time per-unit in the experimental group (image recognition+Raman spectroscopy confirmation and verification) was reduced by 31.5%-43.3%, compared with the control group (image recognition+manual visual comparison with actual objects)( P <0.001). Nurses’ satisfaction scores in the dimensions of operational convenience, identification efficiency, verification confidence, and psychological stress relief in the experimental group were all significantly superior to those of the control group ( P <0.01). CONCLUSIONS The dual-verification system of “image pre-screening and Raman spectroscopy confirmation” effectively overcomes the technical limitations of conventional machine vision. It enhances work efficiency and staff satisfaction while ensuring medication safety.

Result Analysis
Print
Save
E-mail