1.Dose response relationship between sleep duration and depressive symptoms risk in children and adolescents
DAI Chaolan, ZHAO Min, WANG Mingming, XI Bo
Chinese Journal of School Health 2026;47(1):80-84
Objective:
To investigate the association between sleep duration and depressive symptoms in children and adolescents, so as to provide scientific evidence for promoting mental health and preventing depression among relevant populations.
Methods:
A total of 2 192 children and adolescents aged 10-17 years with complete data from the 2018 China Family Panel Studies Database were included. Eight item Center for Epidemiologic Studies Depressive Scale(CES-D8) was used to assess participants depressive levels, and sleep duration was assessed via questionnaire. Multivariate Logistic regression model was used to analyze the association between different sleep duration categories and depressive symptom occurrence among children and adolescents. A restricted cubic spline(RCS) model analyzed the dose response relationship between sleep duration and the risk of depressive symptoms occurrence and segmented Logistic regression models to identify dose response effects.
Results:
Among the surveyed children and adolescents, 524(23.91%) exhibited depressive symptoms. Compared to those with sufficient sleep, children aged 10-12 years had a higher risk of depressive symptoms on average per day( OR =1.66, 95% CI =1.19-2.33) and during weekdays( OR =1.76, 95% CI =1.26-2.46), as well as in adolescents aged 13-17 years on a daily basis( OR =1.40,95% CI =1.06-1.85) and during weekdays( OR = 1.48,95% CI =1.12-1.95), and excessive sleep in adolescents on rest days was also significantly associated with higher risk of depressive symptoms( OR =1.65,95% CI =1.11-2.43)(all P <0.05). RCS analysis results indicate that children s sleep duration exhibits a linear negative correlation with the risk of depressive symptoms(all P nonlinear >0.05), while adolescents sleep duration showed a U shaped association with depressive symptoms(all P nonlinear <0.05) on a daily basis, during weekdays and weekends, with potential threshold effects at 10.00, 9.88, and 9.60 hours, respectively.
Conclusions
Sleep duration among children and adolescents is associated with depressive symptoms, with notable age related differeneces. It is recommended to develop targeted age specific interventions to reduce the risk of depressive symptoms in children and adolescents.
2.Safety analysis of Yttrium-90 resin microsphere selective internal radiation therapy on malignant liver tumors
Jia CAI ; Shiwei TANG ; Rongli LI ; Mingxin KONG ; Hongyan DING ; Xiaofeng YUAN ; Yuying HU ; Ruimei LIU ; Xiaoyan ZHU ; Wenjun LI ; Haibin ZHANG ; Guanwu WANG
Chinese Journal of Clinical Medicine 2025;32(1):24-29
Objective To explore the safety of Yttrium-90 resin microsphere selective internal radiation therapy (90Y-SIRT) on malignant liver tumors. Methods A retrospective analysis was conducted on 64 patients with malignant liver tumors who underwent 90Y-SIRT from February 2023 to November 2024 at Weifang People’s Hospital. The clinical characteristics of the patients and the occurrence of adverse reactions after treatment were analyzed to assess the safety of 90Y-SIRT. Results Among the 64 patients, there were 52 males (81.25%) and 12 females (18.75%); the average age was (56.29±11.08) years. Seven patients (10.94%) had tumors with maximum diameter of less than 5 cm, 38 patients (59.38%) had tumors with maximum diameter of 5-10 cm, and 19 patients (29.68%) had tumors with maximum diameter of greater than 10 cm. There were 47 cases (73.44%) of solitary lesions and 17 cases (26.56%) of multiple lesions; 53 cases (82.81%) were primary liver cancers and 11 cases (17.19%) were metastatic liver cancers. Of the 64 patients, 63 successfully completed the Technetium-99m macroaggregated albumin (99mTc-MAA) perfusion test and received the 90Y-SIRT; one patient received 90Y-SIRT after the second 99mTc-MAA perfusion test due to a work error. The most common adverse reactions included grade 1 alanine aminotransferase (ALT) elevation in 26 cases (40.62%) and grade 2 in 2 cases (9.37%), grade 1 aspartate aminotransferase (AST) elevation in 27 cases (42.18%) and grade 2 in 7 cases (10.93%); grade 1 nausea in 17 cases (26.56%) and grade 2 in 6 cases (9.37%); grade 1 abdominal pain in 12 cases (18.75%), grade 2 in 5 cases (7.81%), and grade 3 in 1 case (1.56%); grade 1 vomiting in 11 cases (17.18%), grade 2 in 5 cases (7.81%), and grade 3 in 1 case (1.56%). Conclusion The adverse reactions of 90Y-SIRT for treating malignant liver tumors are mild, indicating good safety.
3.Performance verification and results analysis of DNA workflow for metagenomic next-generation sequencing
Shangdong YANG ; Yang XIAO ; Wen XI ; Zhe LIU ; Fang WANG ; Xiaoqin WANG
Journal of Xi'an Jiaotong University(Medical Sciences) 2025;46(1):162-168
Objective To establish a performance verification scheme for the metagenomic next-generation sequencing(mNGS)DNA workflow.Methods Reference materials and clinical samples were used for conducting experiments.The mNGS detection results were evaluated in terms of limit of detection(LOD),repeatability,robustness,anti-interference ability,specificity and accuracy,as well as the patterns of library construction and the performance of sequencers.Results All species in the reference materials were stably detected,and the LOD of mNGS was 5.0E+02 CFU/mL(copies/mL).The repeatability was 100%and the within-batch(coefficient of variation)CV ranged from 8.53%to 38.73%.The linear correlation coefficient|r|>0.9 was found between the input pathogenic microorganism concentration and the read count.Meanwhile,the experimental robustness was found to be good.The results of the anti-interference test showed that the higher concentration of human DNA inputted,the fewer pathogenic microorganism read counts detected by mNGS.Meanwhile,the read counts of related species presented a proportional relationship with the corresponding pathogenic microorganisms concentration inputted,which meant the validation of the cross-interference test had been passed.Furthermore,the detection result of D0 was negative.The accuracy of clinical samples testing was 90.9%(10/11).In addition,the library quality control results obtained by the automatic liquid handling workstation and manually operation were all acceptable.The performance of the three Illumina sequencers met or were better than the factory standards.Conclusion The clinical laboratory performance verification scheme for mNGS detection was established,which included the design for reference materials,comparison of different patterns for library construction,and performance evaluation of the sequencers.More importantly,the performance verification scheme can be used to evaluate and ensure the quality of mNGS DNA workflow detection process.
4.Analysis of Surgical Treatment Outcomes in 709 Cases of Infective Endocarditis
Chaoji ZHANG ; Zining WU ; Xingrong LIU ; Guotao MA ; Shangdong XU ; Jianzhou LIU ; Sheng YANG ; Yanxue ZHAO ; Xinpei LIU ; Xiaocui WANG ; Xiaojun MA ; Ligang FANG ; Chunhua YU ; Huaiwu HE ; Qi MIAO ; Jun ZHENG
Medical Journal of Peking Union Medical College Hospital 2025;17(1):197-203
To review the clinical characteristics, short-term outcomes, and risk factors of patients with infective endocarditis(IE) who underwent surgical treatment at a single center, and to summarize treatment experience. Consecutive patients diagnosed with IE who underwent cardiac surgery at the Department of Cardiac Surgery, Peking Union Medical College Hospital between May 2012 and June 2024 were enrolled. Statistical analyses were performed on their baseline characteristics, comorbidities, IE predisposing factors, surgical indications, pathogen distribution, surgical strategies, short-term outcomes, and associated risk factors. A total of 709 IE patients meeting the inclusion and exclusion criteria were included. IE involved left-sided valves in 85.3% of cases. The median age was 48(35, 58) years, and 68.0% were male. Prosthetic valve endocarditis accounted for 8.7%. Patients with left-sided IE had a higher prevalence of comorbidities. Streptococcus was the causative pathogen in 43.2% of patients, while right-sided IE was more frequently associated with Significant differences in pathogen distribution were observed between patients with left-sided and right-sided IE. Heart failure was identified as an independent risk factor for both perioperative mortality and adverse outcomes in surgically treated patients. Through strict timing of surgical intervention and optimized perioperative management, surgical treatment may effectively reduce mortality and improve prognosis in patients with IE.
5.Digital three-dimensional assisted unilateral biportal endoscopy in treatment of highly isolated lumbar disc herniation with translaminar approach.
Weiliang SU ; Suni LU ; Dong LIU ; Jianqiang XING ; Peng HU ; Yongfeng DOU ; Xiaopeng GENG ; Dawei WANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(3):346-353
OBJECTIVE:
To investigate the effectiveness of digital three-dimensional (3D) assisted unilateral biportal endoscopy (UBE) in the treatment of highly isolated lumbar disc herniation (LDH) with translaminar approach.
METHODS:
The clinical data of 59 patients who met the selection criteria and underwent UBE treatment due to highly isolated LDH between January 2022 and December 2023 were retrospectively analyzed. Among them, 25 cases were treated with digital 3D assisted translaminar approach (observation group) and 34 cases were treated with interlaminar approach (control group). There was no significant difference in gender, age, disease duration, surgical segment, and preoperative visual analogue scale (VAS) score and Oswestry disability index (ODI) between the two groups ( P>0.05). The operation time, intraoperative blood loss, and lateral articular surface preservation rate were recorded and compared between the two groups. VAS score and ODI were used to evaluate the improvements of pain and function before operation and at 3 and 6 months after operation. The modified MacNab criteria was used to evaluate the effectiveness at last follow-up.
RESULTS:
One patient in the control group had dural tear, and the other patients had no nerve injury, infection, dural tear, or other related complications. There was no significant difference in operation time and intraoperative blood loss between the two groups ( P>0.05). Patients in both groups were followed up 6-13 months, with an average of 8.3 months. The lateral articular surface preservation rate in the observation group was significantly higher than that in the control group ( P<0.05). Three patients in the observation group and 2 patients in the control group had calf muscle venous thrombosis, which was cured after anticoagulant treatment with rivaroxaban and delayed exercise time. There was no recurrence or second operation during the follow-up period. The VAS score and ODI of the two groups at 3 and 6 months after operation significantly improved when compared with those before operation ( P<0.05). There was no significant difference between the two groups at each time point after operation ( P>0.05). At last follow-up, the effectiveness was evaluated according to the modified MacNab criteria, and there was no significant difference in the evaluation grade and excellent and good rate between the two groups ( P>0.05).
CONCLUTION
UBE via translaminar approach is safe and effective for the treatment of highly isolated LDH, which is beneficial to protect the facet joint, maintain spinal stability, and reduce soft tissue injury. With the assistance of digital 3D technique, preoperative planning can be performed accurately.
Humans
;
Intervertebral Disc Displacement/diagnostic imaging*
;
Lumbar Vertebrae/diagnostic imaging*
;
Male
;
Retrospective Studies
;
Female
;
Endoscopy/methods*
;
Treatment Outcome
;
Middle Aged
;
Adult
;
Imaging, Three-Dimensional
;
Operative Time
;
Pain Measurement
6.Pharmacokinetics study of Dayuanyin in normal and febrile rats.
Yu-Jie HOU ; Kang-Ning XIAO ; Jian-Yun BI ; Xin-Jun ZHANG ; Xin-Rui LI ; Yu-Qing WANG ; Ming SU ; Xin-Ru SUN ; Hui ZHANG ; Bo-Yang WANG ; Li-Jie WANG ; Shan-Xin LIU
China Journal of Chinese Materia Medica 2025;50(2):527-533
Based on the pharmacokinetics theory, this study investigated the pharmacokinetic characteristics of albiflorin, paeoniflorin, wogonoside, and wogonin in normal and febrile rats and summarized absorption and elimination rules of Dayuanyin in them to provide reference for further development and clinical application of Dayuanyin. Blood samples were taken from the fundus venous plexus of normal and model rats after intragastric administration of Dayuanyin at different time points. The concentration of each substance in blood was determined by ultra performance liquid chromatography-triple quadrupole mass spectrometry(UPLC-MS/MS) technique at different time points. DAS 2.0, a piece of pharmacokinetics software, was used to calculate the pharmacokinetic parameters of each component. The results show that the 4 components had good linear relationship in their respective ranges, and the results of methodological investigation met the requirements. The pharmacokinetic parameters of C_(max), T_(max), t_(1/2), AUC_(0-t), AUC_(0-∞), and MRT_(0-t) were calculated by the DAS 2.0 non-compartmental model. Compared with those in the normal group, C_(max) and AUC_(0-t) of the 4 components in the model group were significantly increased. There were significant differences in the pharmacokinetic characteristics between the normal and model groups, suggesting that the absorption and elimination of Dayuanyin may be affected by the changes of internal environment of the body in different physiological states.
Animals
;
Rats
;
Drugs, Chinese Herbal/administration & dosage*
;
Male
;
Rats, Sprague-Dawley
;
Fever/metabolism*
;
Tandem Mass Spectrometry
;
Chromatography, High Pressure Liquid
;
Glucosides/pharmacokinetics*
;
Monoterpenes
7.Performance validation and result analysis of bioinformatics procedure for metagenomic next-generation sequencing
Wen XI ; Yang XIAO ; Shangdong YANG ; Zhe LIU ; Fang WANG ; Xiaoqin WANG
Chinese Journal of Laboratory Medicine 2025;48(1):117-124
Objective:To establish a preliminary performance validation protocol for the bioinformatics procedure of metagenomic next-generation sequencing (mNGS) in clinical laboratories.Methods:Three types of simulated datasets were designed and the CatⅠ dataset mainly consisted of pathogen reference genomes and human sequences. CatⅠA was a dataset composed of common pathogens mixed with human sequences and was used to evaluate the inclusiveness, accuracy, recall rates, precision, F1-Score, and other indicators of the mNGS bioinformatics procedure. CatⅠB was a dataset composed of closely related species of common pathogens mixed with human sequences, which was used to evaluate the discriminating ability of closely related species of bioinformatics procedure by calculating the detection rates and the relative abundance ratio of closely related species. The real data of 200 clinical samples was selected to construct CatⅡ and the simulated dataset consisted of colonized bacteria, experimental environment bacteria, reagent engineering bacteria, pathogen reference genomes, and human sequences, which was used to evaluate the sensitivity, specificity, and accuracy of bioinformatics pipeline for pathogens detection. The CatⅢ dataset was obtained from the negative bronchoalveolar lavage fluid BALF sequencing data mixed with 20 rare pathogens sequences in order to evaluate the positive detection rates and recall rates of rare pathogens in the bioinformatics analysis.Results:The analysis of the CatⅠA dataset showed that the positive consistency rate, inclusiveness, precision and accuracy of the bioinformatics peocedure under three sequence gradients were all greater than 99%, with a recall rate of 72.31% (95% CI 69.61%-75.01%) and a F1 Score of 82.00% (95% CI 79.77%-84.22%). In the CatⅠB dataset, the closely related species could be effectively detected at all sequence and proportion gradients, and the relative abundance ratio of closely related species was within 2 times of the design ratio except for the coronavirus, haemophilus, primate bocaparvovirus, human respiratory syncytial virus, and eimeria, indicating good ability to identify the closely related species. All the 24 species of pathogens included in CatⅡ dataset were effectively detected, with the sensitivity, specificity, and accuracy all greater than 90%. All rare pathogens were detected in the CatⅢ dataset, with a detection rate of 100%. Conclusions:With the simulated datasets, the performance validation scheme for the mNGS bioinformatics analysis was preliminary established and could evaluate the accuracy of sequence classification, the ability to identify the closely related species, and detection ability of common and rare pathogens, which may provide some references for the construction of mNGS process.
8.Performance verification and results analysis of DNA workflow for metagenomic next-generation sequencing
Shangdong YANG ; Yang XIAO ; Wen XI ; Zhe LIU ; Fang WANG ; Xiaoqin WANG
Journal of Xi'an Jiaotong University(Medical Sciences) 2025;46(1):162-168
Objective To establish a performance verification scheme for the metagenomic next-generation sequencing(mNGS)DNA workflow.Methods Reference materials and clinical samples were used for conducting experiments.The mNGS detection results were evaluated in terms of limit of detection(LOD),repeatability,robustness,anti-interference ability,specificity and accuracy,as well as the patterns of library construction and the performance of sequencers.Results All species in the reference materials were stably detected,and the LOD of mNGS was 5.0E+02 CFU/mL(copies/mL).The repeatability was 100%and the within-batch(coefficient of variation)CV ranged from 8.53%to 38.73%.The linear correlation coefficient|r|>0.9 was found between the input pathogenic microorganism concentration and the read count.Meanwhile,the experimental robustness was found to be good.The results of the anti-interference test showed that the higher concentration of human DNA inputted,the fewer pathogenic microorganism read counts detected by mNGS.Meanwhile,the read counts of related species presented a proportional relationship with the corresponding pathogenic microorganisms concentration inputted,which meant the validation of the cross-interference test had been passed.Furthermore,the detection result of D0 was negative.The accuracy of clinical samples testing was 90.9%(10/11).In addition,the library quality control results obtained by the automatic liquid handling workstation and manually operation were all acceptable.The performance of the three Illumina sequencers met or were better than the factory standards.Conclusion The clinical laboratory performance verification scheme for mNGS detection was established,which included the design for reference materials,comparison of different patterns for library construction,and performance evaluation of the sequencers.More importantly,the performance verification scheme can be used to evaluate and ensure the quality of mNGS DNA workflow detection process.
9.Performance validation and result analysis of bioinformatics procedure for metagenomic next-generation sequencing
Wen XI ; Yang XIAO ; Shangdong YANG ; Zhe LIU ; Fang WANG ; Xiaoqin WANG
Chinese Journal of Laboratory Medicine 2025;48(1):117-124
Objective:To establish a preliminary performance validation protocol for the bioinformatics procedure of metagenomic next-generation sequencing (mNGS) in clinical laboratories.Methods:Three types of simulated datasets were designed and the CatⅠ dataset mainly consisted of pathogen reference genomes and human sequences. CatⅠA was a dataset composed of common pathogens mixed with human sequences and was used to evaluate the inclusiveness, accuracy, recall rates, precision, F1-Score, and other indicators of the mNGS bioinformatics procedure. CatⅠB was a dataset composed of closely related species of common pathogens mixed with human sequences, which was used to evaluate the discriminating ability of closely related species of bioinformatics procedure by calculating the detection rates and the relative abundance ratio of closely related species. The real data of 200 clinical samples was selected to construct CatⅡ and the simulated dataset consisted of colonized bacteria, experimental environment bacteria, reagent engineering bacteria, pathogen reference genomes, and human sequences, which was used to evaluate the sensitivity, specificity, and accuracy of bioinformatics pipeline for pathogens detection. The CatⅢ dataset was obtained from the negative bronchoalveolar lavage fluid BALF sequencing data mixed with 20 rare pathogens sequences in order to evaluate the positive detection rates and recall rates of rare pathogens in the bioinformatics analysis.Results:The analysis of the CatⅠA dataset showed that the positive consistency rate, inclusiveness, precision and accuracy of the bioinformatics peocedure under three sequence gradients were all greater than 99%, with a recall rate of 72.31% (95% CI 69.61%-75.01%) and a F1 Score of 82.00% (95% CI 79.77%-84.22%). In the CatⅠB dataset, the closely related species could be effectively detected at all sequence and proportion gradients, and the relative abundance ratio of closely related species was within 2 times of the design ratio except for the coronavirus, haemophilus, primate bocaparvovirus, human respiratory syncytial virus, and eimeria, indicating good ability to identify the closely related species. All the 24 species of pathogens included in CatⅡ dataset were effectively detected, with the sensitivity, specificity, and accuracy all greater than 90%. All rare pathogens were detected in the CatⅢ dataset, with a detection rate of 100%. Conclusions:With the simulated datasets, the performance validation scheme for the mNGS bioinformatics analysis was preliminary established and could evaluate the accuracy of sequence classification, the ability to identify the closely related species, and detection ability of common and rare pathogens, which may provide some references for the construction of mNGS process.
10.Epidemiological characteristics of respiratory pathogens in children at a hospital in Xi’an from 2023 to 2024
Yang XIAO ; Shangdong YANG ; Wen XI ; Junhui LIU ; Fang WANG
Journal of Xi'an Jiaotong University(Medical Sciences) 2024;45(6):999-1006
[Objective] To investigate the status and epidemiological characteristics of suspected acute respiratory tract infection (ARIS) in children at The First Affiliated Hospital of Xi’an Jiaotong University from July 2023 to June 2024, so as to provide evidence for the prevention and treatment of children in this area. [Methods] A total of 12 169 throat swab samples were collected from children with ARIS during this period, including 6 535 male children and 5 634 female children, with an age of M(Q


Result Analysis
Print
Save
E-mail