1.A cultural values model of pakikipag-ugnayan: Examining hiya, pakikisama, and pakikipag-ugnayan among Filipino generation Z nurses.
Angelika B. AVILA ; Francis Oliver M. ALDABA ; Maryjoy Loraine T. ALMONTE ; Enrique B. ALZATE ; Trisha B. AMITA ; Ma. Andrea M. AVILA ; Zg Jungco A. ASOY ; Tristan Jourdan C. DELA CRUZ
Acta Medica Philippina 2026;60(9):91-99
OBJECTIVES
This study explored the interplay of three Filipino cultural values—hiya (modesty/self-restraint), pakikisama (conflict-avoidance dimension of social harmony), and pakikipag-ugnayan (professional engagement, characterized by vigor, dedication, and absorption)—among Generation Z nurses in Quezon City. Specifically, it assessed their levels, examined interrelationships through correlation and path analysis, and developed a framework to illustrate their influence on nursing practice. In the Filipino context, hiya encompasses both positive dimensions, such as conscientiousness, moral accountability, and social responsibility, and constraining dimensions, including excessive self-restraint, fear of criticism, and inhibition. Pakikisama, while fostering harmony, may discourage assertiveness and limit open communication. Pakikipag-ugnayan, conceptualized here as engagement, reflects dedication, vigor, and absorption, which are vital for performance, patient safety, and workforce retention.
METHODSA descriptive–correlational design was utilized to assess the relationships among hiya, pakikisama, and pakikipag-ugnayan. Data were gathered through a structured, self-administered questionnaire comprising validated scales for each construct, distributed in online formats to accommodate participants’ availability and work schedules. The purposive sample consisted of 115 Filipino Generation Z nurses engaged in direct patient care in various healthcare facilities in Quezon City. Data analysis involved descriptive statistics to summarize variable scores, Spearman’s rho to examine bivariate correlations, and path analysis to determine the direct and indirect effects among the variables. The results of the path analysis were used to develop a proposed framework illustrating the interplay of these cultural values in nursing practice.
RESULTSPath analysis revealed distinct patterns in the interplay of hiya, pakikisama, and pakikipag-ugnayan among Generation Z nurses in Quezon City. Very high hiya scores (mean = 5.32) reflected both moral accountability and restraint-oriented tendencies. Despite these positive indicators, hiya showed a negative correlation with pakikipag-ugnayan, suggesting that its inhibiting side—marked by fear of criticism and avoidance of mistakes—may overshadow its constructive moral aspects. In contrast, the path analysis identified a moderate positive direct effect between hiya and pakikipag-ugnayan (β = 0.400, pCONCLUSION
Among Generation Z nurses, hiya demonstrates a dual role: while its ethical and conscientious aspects can strengthen pakikipag-ugnayan, its inhibiting side may suppress pakikipag-ugnayan. Pakikisama, operationalized as conflict avoidance and withholding dissent, emerged as a barrier to pakikipag-ugnayan by discouraging open communication. These findings informed the development of the Hiya–Pakikisama– Pakikipag-ugnayan Cultural Dynamics Framework, which illustrates how cultural values can simultaneously enable and constrain professional engagement. The framework has potential applications in nursing education and organizational practice, particularly in designing reflective learning, mentorship, and communication strategies that balance cultural sensitivity with assertiveness. Further validation across generations and healthcare settings is recommended to refine its applicability.
Human ; Weights And Measures ; Sensitivity And Specificity ; Retention (psychology) ; Education, Nursing ; Social Responsibility ; Appointments And Schedules ; Conflict (psychology)
2.Diagnostic value of high-resolution temporal bone CT combined with DW-MRI fusion technology in middle ear cholesteatoma.
Qimei YANG ; Yaya CAO ; Long JIN ; Jin ZHANG ; Jinrui MA ; Wen ZHANG
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2025;39(12):1120-1125
Objective:To explore the application value of high-resolution temporal bone CT and DW-MRI fusion technology in achieving precise diagnosis and anatomical localization of middle ear cholesteatoma during endoscopic surgery. Methods:Eighteen patients initially diagnosed with middle ear cholesteatoma in the Department of Otolaryngology Head and Neck Surgery, Shaanxi Provincial People's Hospital, from January to June 2024 were enrolled.Preoperative high-resolution temporal bone CT and DW-MRI were performed, and rtStation software was used for image fusion to construct CT-MRI fused images. The involvement of cholesteatoma in six anatomical subregions of the temporal bone was evaluated. Using surgical pathology as the gold standard, and combining surgical videos and anatomical records, the sensitivity, specificity, and accuracy of pure CT, pure DW-MRI, and CT-MRI fused images in evaluating middle ear cholesteatoma lesions were compared. Results:A total of 18 patients were included, and 17 cases were pathologically confirmed as middle ear cholesteatoma postoperatively. The sensitivity of the preoperative of preoperative CT was 100%, but the specificity was only 44.44%, with an overall accuracy of 72.22%; the sensitivity and specificity of DW-MRI evaluation were 81.46% and 85.19%, the accuracy was 83.33%, respectively. In contrast, the sensitivity and specificity of CT-MRI fusion image to the spatial localization of cholesteatoma were higher than that of DW-MRI alone(92.59% vs 81.46%; 98.15% vs 85.19%), and the diagnostic accuracy was also significantly improved(95.37% vs 83.33%). The Kappa values for the agreement between HRCT, DW-MRI, and CT-MRI segmentation localization and pathological results were 0.444, 0.667, and 0.907 respectively. The chi-square paired t-test confirmed statistically significant diagnostic differences between groups(P<0.001). Results demonstrated that CT-MRI significantly outperformed HRCT and DW-MRI in diagnostic efficacy for segmental localization of primary posterior congenital middle ear cholesteatoma. Conclusion:High-resolution temporal bone CT combined with DW-MRI fusion technology demonstrates higher sensitivity, specificity, and accuracy in the diagnosis and spatial localization of middle ear cholesteatoma than single imaging modalities. It can provide more precise evaluation of lesion scope for endoscopic surgery, showing important clinical application value.
Humans
;
Cholesteatoma, Middle Ear/diagnostic imaging*
;
Tomography, X-Ray Computed
;
Temporal Bone/diagnostic imaging*
;
Diffusion Magnetic Resonance Imaging
;
Female
;
Male
;
Adult
;
Sensitivity and Specificity
;
Middle Aged
;
Endoscopy
3.A myocardial infarction detection and localization model based on multi-scale field residual blocks fusion with modified channel attention.
Qiucen WU ; Xueqi LU ; Yaoqi WEN ; Yong HONG ; Yuliang WU ; Chaomin CHEN
Journal of Southern Medical University 2025;45(8):1777-1790
OBJECTIVES:
We propose a myocardial infarction (MI) detection and localization model for improving the diagnostic accuracy for MI to provide assistance to clinical decision-making.
METHODS:
The proposed model was constructed based on multi-scale field residual blocks fusion modified channel attention (MSF-RB-MCA). The model utilizes lead II electrocardiogram (ECG) signals to detect and localize MI, and extracts different levels of feature information through the multi-scale field residual block. A modified channel attention for automatic adjustment of the feature weights was introduced to enhance the model's ability to focus on the MI region, thereby improving the accuracy of MI detection and localization.
RESULTS:
A 5-fold cross-validation test of the model was performed using the publicly available Physikalisch-Technische Bundesanstalt (PTB) dataset. For MI detection, the model achieved an accuracy of 99.96% on the test set with a specificity of 99.84% and a sensitivity of 99.99%. For MI localization, the accuracy, specificity and sensitivity were 99.81%, 99.98% and 99.65%, respectively. The performances of the model for MI detection and localization were superior to those of other comparison models.
CONCLUSIONS
The proposed MSF-RB-MCA model shows excellent performance in AI detection and localization based on lead II ECG signals, demonstrating its great potential for application in wearable devices.
Myocardial Infarction/diagnosis*
;
Humans
;
Electrocardiography/methods*
;
Signal Processing, Computer-Assisted
;
Algorithms
;
Sensitivity and Specificity
4.A machine learning approach for the diagnosis of obstructive sleep apnoea using oximetry, demographic and anthropometric data.
Zhou Hao LEONG ; Shaun Ray Han LOH ; Leong Chai LEOW ; Thun How ONG ; Song Tar TOH
Singapore medical journal 2025;66(4):195-201
INTRODUCTION:
Obstructive sleep apnoea (OSA) is a serious but underdiagnosed condition. Demand for the gold standard diagnostic polysomnogram (PSG) far exceeds its availability. More efficient diagnostic methods are needed, even in tertiary settings. Machine learning (ML) models have strengths in disease prediction and early diagnosis. We explored the use of ML with oximetry, demographic and anthropometric data to diagnose OSA.
METHODS:
A total of 2,996 patients were included for modelling and divided into test and training sets. Seven commonly used supervised learning algorithms were trained with the data. Sensitivity (recall), specificity, positive predictive value (PPV) (precision), negative predictive value, area under the receiver operating characteristic curve (AUC) and F1 measure were reported for each model.
RESULTS:
In the best performing four-class model (neural network model predicting no, mild, moderate or severe OSA), a prediction of moderate and/or severe disease had a combined PPV of 94%; one out of 335 patients had no OSA and 19 had mild OSA. In the best performing two-class model (logistic regression model predicting no-mild vs. moderate-severe OSA), the PPV for moderate-severe OSA was 92%; two out of 350 patients had no OSA and 26 had mild OSA.
CONCLUSION
Our study showed that the prediction of moderate-severe OSA in a tertiary setting with an ML approach is a viable option to facilitate early identification of OSA. Prospective studies with home-based oximeters and analysis of other oximetry variables are the next steps towards formal implementation.
Humans
;
Oximetry/methods*
;
Sleep Apnea, Obstructive/diagnosis*
;
Male
;
Female
;
Middle Aged
;
Machine Learning
;
Polysomnography
;
Adult
;
Anthropometry
;
ROC Curve
;
Aged
;
Algorithms
;
Predictive Value of Tests
;
Sensitivity and Specificity
;
Neural Networks, Computer
;
Demography
5.Deploying artificial intelligence in the detection of adult appendicular and pelvic fractures in the Singapore emergency department after hours: efficacy, cost savings and non-monetary benefits.
John Jian Xian QUEK ; Oliver James NICKALLS ; Bak Siew Steven WONG ; Min On TAN
Singapore medical journal 2025;66(4):202-207
INTRODUCTION:
Radiology plays an integral role in fracture detection in the emergency department (ED). After hours, when there are fewer reporting radiologists, most radiographs are interpreted by ED physicians. A minority of these interpretations may miss diagnoses, which later require the callback of patients for further management. Artificial intelligence (AI) has been viewed as a potential solution to augment the shortage of radiologists after hours. We explored the efficacy of an AI solution in the detection of appendicular and pelvic fractures for adult radiographs performed after hours at a general hospital ED in Singapore, and estimated the potential monetary and non-monetary benefits.
METHODS:
One hundred and fifty anonymised abnormal radiographs were retrospectively collected and fed through an AI fracture detection solution. The radiographs were re-read by two radiologist reviewers and their consensus was established as the reference standard. Cases were stratified based on the concordance between the AI solution and the reviewers' findings. Discordant cases were further analysed based on the nature of the discrepancy into overcall and undercall subgroups. Statistical analysis was performed to evaluate the accuracy, sensitivity and inter-rater reliability of the AI solution.
RESULTS:
Ninety-two examinations were included in the final study radiograph set. The AI solution had a sensitivity of 98.9%, an accuracy of 85.9% and an almost perfect agreement with the reference standard.
CONCLUSION
An AI fracture detection solution has similar sensitivity to human radiologists in the detection of fractures on ED appendicular and pelvic radiographs. Its implementation offers significant potential measurable cost, manpower and time savings.
Humans
;
Singapore
;
Emergency Service, Hospital
;
Fractures, Bone/diagnostic imaging*
;
Artificial Intelligence
;
Retrospective Studies
;
Adult
;
Male
;
Female
;
Cost Savings
;
Middle Aged
;
Pelvic Bones/diagnostic imaging*
;
Reproducibility of Results
;
Aged
;
Sensitivity and Specificity
;
Radiography
6.Machine learning to risk stratify chest pain patients with non-diagnostic electrocardiogram in an Asian emergency department.
Ziwei LIN ; Tar Choon AW ; Laurel JACKSON ; Cheryl Shumin KOW ; Gillian MURTAGH ; Siang Jin Terrance CHUA ; Arthur Mark RICHARDS ; Swee Han LIM
Annals of the Academy of Medicine, Singapore 2025;54(4):219-226
INTRODUCTION:
Elevated troponin, while essential for diagnosing myocardial infarction, can also be present in non-myocardial infarction conditions. The myocardial-ischaemic-injury-index (MI3) algorithm is a machine learning algorithm that considers age, sex and cardiac troponin I (TnI) results to risk-stratify patients for type 1 myocardial infarction.
METHOD:
Patients aged ≥25 years who presented to the emergency department (ED) of Singapore General Hospital with symptoms suggestive of acute coronary syndrome with no diagnostic 12-lead electrocardiogram (ECG) changes were included. Participants had serial ECGs and high-sensitivity troponin assays performed at 0, 2 and 7 hours. The primary outcome was the adjudicated diagnosis of type 1 myocardial infarction at 30 days. We compared the performance of MI3 in predicting the primary outcome with the European Society of Cardiology (ESC) 0/2-hour algorithm as well as the 99th percentile upper reference limit (URL) for TnI.
RESULTS:
There were 1351 patients included (66.7% male, mean age 56 years), 902 (66.8%) of whom had only 0-hour troponin results and 449 (33.2%) with serial (both 0 and 2-hour) troponin results available. MI3 ruled out type 1 myocardial infarction with a higher sensitivity (98.9, 95% confidence interval [CI] 93.4-99.9%) and similar negative predictive value (NPV) 99.8% (95% CI 98.6-100%) as compared to the ESC strategy. The 99th percentile cut-off strategy had the lowest sensitivity, specificity, positive predictive value and NPV.
CONCLUSION
The MI3 algorithm was accurate in risk stratifying ED patients for myocardial infarction. The 99th percentile URL cut-off was the least accurate in ruling in and out myocardial infarction compared to the other strategies.
Humans
;
Male
;
Female
;
Emergency Service, Hospital
;
Middle Aged
;
Electrocardiography
;
Machine Learning
;
Singapore
;
Chest Pain/blood*
;
Troponin I/blood*
;
Myocardial Infarction/blood*
;
Risk Assessment/methods*
;
Aged
;
Algorithms
;
Acute Coronary Syndrome/blood*
;
Adult
;
Sensitivity and Specificity
7.Diagnostic value of 99mTc-MDP three-phase bone scintigraphy combined with C-reaction protein for periprosthetic joint infection.
Guojie LIU ; Xiaolan SONG ; Pei ZHAI ; Shipeng SONG ; Weidong BAO ; Yawei DUAN ; Wei ZHANG ; Yafeng LIU ; Yongqiang SUN ; Shuailei LI
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(9):1180-1186
OBJECTIVE:
To investigate the diagnostic efficacy of 99mTc-MDP three-phase bone scintigraphy (TPBS) combined with C-reactive protein (CRP) for periprosthetic joint infection (PJI).
METHODS:
The clinical data of 198 patients who underwent revision surgery of artificial joint between January 2017 and January 2024 and received TPBS examination before surgery were retrospectively analyzed. There were 77 males and 121 females with an average age of 63.74 years ranging from 24 to 92 years. There were 90 cases of hip arthroplasty and 108 cases of knee arthroplasty. PJI was diagnosed according to the 2013 American Musculoskeletal Infection Society (MSIS) standard diagnostic criteria. The sensitivity, specificity, accuracy, negative predictive value (NPV), and positive predict value (PPV) were calculated. The receiver operating characteristic (ROC) curve was used to compare the diagnostic performance of the three methods, and the area under curve (AUC) was used to evaluate the diagnostic performance.
RESULTS:
According to the 2013 MSIS criteria, 116 cases were diagnosed as PJI, and the remaining 82 cases were aseptic loosening. The cases of PJI diagnosed by TPBS, CRP, and TPBS-CRP were 125, 109, and 137 respectively, and the cases of aseptic loosening were 73, 89, and 61 respectively. The sensitivity, accuracy, NPV, and PPV of TPBS-CRP combination in the diagnosis of PJI were higher than those of TPBS and CRP, but the specificity was lower than that of TPBS and CRP. ROC curve analysis further showed that the AUC value of TPBS-CRP combination was better than that of TPBS and CRP. The severity of bone defect and the duration of symptoms in patients with false positive TPBS diagnosis were worse than those in patients with true negative TPBS diagnosis (P<0.05), but there was no significant difference in the survival time of prosthesis between the two groups (P>0.05). Among the patients diagnosed with PJI by TPBS, CRP, and TPBS-CRP, 49, 35, and 54 patients had received antibiotic treatment 2 weeks before diagnosis, respectively. There was no significant difference in the diagnostic accuracy of TPBS and TPBS-CRP before diagnosis between patients treated with and without antibiotics and those not treated (P>0.05). The diagnostic accuracy of antibiotic therapy before CRP diagnosis was significantly lower than that of untreated patients (P<0.05).
CONCLUSION
TPBS and CRP have limited specificity in differentiating PJI from aseptic loosening. The TPBS-CRP combination diagnostic method can synergize the local bone metabolic characteristics and systemic inflammatory response to achieve higher diagnostic accuracy, but caution should be exercised in patients with severe bone defects and longer symptom duration.
Humans
;
Prosthesis-Related Infections/blood*
;
Middle Aged
;
Male
;
Female
;
Aged
;
C-Reactive Protein/metabolism*
;
Retrospective Studies
;
Adult
;
Radionuclide Imaging/methods*
;
Arthroplasty, Replacement, Knee/adverse effects*
;
Aged, 80 and over
;
Technetium Tc 99m Medronate
;
Arthroplasty, Replacement, Hip/adverse effects*
;
Sensitivity and Specificity
;
Knee Prosthesis/adverse effects*
;
ROC Curve
;
Reoperation
;
Radiopharmaceuticals
;
Young Adult
8.Comparative study on accuracy of three imaging methods in diagnosis of subacromial impingement syndrome.
Linfeng ZI ; Hongfu JIN ; Jianwei ZHU ; Guoxu ZHANG ; Yao TONG ; Sijie CHEN ; Wenze SHAO ; Xin TANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(10):1290-1295
OBJECTIVE:
To compare the diagnostic accuracy of supraspinatus muscle outlet X-ray film, oblique sagittal multislice helical CT (MSCT), and oblique sagittal MRI in the diagnosis of subacromial impingement syndrome (SIS).
METHODS:
A retrospective analysis was conducted on the imaging data of 106 patients diagnosed with SIS between January 2023 and December 2024. The cohort consisted of 32 males and 74 females, with ages ranging from 43 to 70 years (mean, 60.19 years). All patients underwent supraspinatus muscle outlet X-ray film, MSCT, and MRI scans, with MSCT further subjected to three-dimensional reconstruction. Two experienced radiologists independently evaluated the acromion morphology in each imaging modality using the Bigliani classification system. Inter-observer reliability was assessed via Kappa statistics. The CT three-dimensional reconstructions were used as the "gold standard". The overall consistency, Kappa values, sensitivity, and specificity of the three imaging modalities were calculated. Receiver operating characteristic (ROC) curves were plotted, and the area under the curve (AUC) was computed.
RESULTS:
The inter-observer reliability for supraspinatus muscle outlet X-ray film, oblique sagittal MSCT, and oblique sagittal MRI was moderate, with Kappa values of 0.62, 0.63, and 0.55, respectively. When compared to the CT three-dimensional reconstructions as the "gold standard", the overall consistency was 88.7% (94/106), 62.3% (66/106), and 58.5% (62/106), respectively. The supraspinatus muscle outlet X-ray film showed excellent consistency (Kappa=0.77), whereas the consistency of MSCT and MRI was lower (Kappa=0.34 and 0.29, respectively). In terms of diagnostic sensitivity and specificity, the supraspinatus muscle outlet X-ray film outperformed oblique sagittal MSCT and oblique sagittal MRI in distinguishing various acromion types. ROC analysis demonstrated that the AUC for the supraspinatus muscle outlet X-ray film was consistently higher than for oblique sagittal MSCT and oblique sagittal MRI, with the highest diagnostic performance observed for type Ⅲ hooked acromion (AUC=0.939).
CONCLUSION
Supraspinatus muscle outlet X-ray film provides the highest diagnostic accuracy for acromion classification in SIS patients, particularly in identifying type Ⅲ hooked acromion, which is strongly associated with SIS. Given its superior sensitivity and consistency, it should be considered the primary screening tool. MSCT and MRI serve as valuable supplementary modalities for complex cases and preoperative evaluation.
Humans
;
Middle Aged
;
Male
;
Female
;
Shoulder Impingement Syndrome/diagnostic imaging*
;
Magnetic Resonance Imaging/methods*
;
Retrospective Studies
;
Aged
;
Adult
;
Imaging, Three-Dimensional
;
Sensitivity and Specificity
;
Tomography, Spiral Computed/methods*
;
Multidetector Computed Tomography/methods*
;
Reproducibility of Results
9.Multidetector computed tomography angiography for diagnosis of traumatic aneurysms associated with penetrating head injuries.
Konstantin Nickolaevich BABICHEV ; Aleksandr Viktorovich SAVELLO ; Alla Vladimirovna ISAEVA ; Dmitrij Vladimirovich SVISTOV ; Igor' Anatol'evich MEN'KOV ; Dzhamaludin Magomedrasulovich ISAEV
Chinese Journal of Traumatology 2025;28(2):91-95
PURPOSE:
To analyze the diagnostic efficacy of computed tomography angiography compared to digital cerebral angiography for the diagnosis of traumatic aneurysms (TAs) associated with combat-related penetrating head injuries and propose the most suitable angiography protocol in this clinical context.
METHODS:
A retrospective analysis was conducted on patients admitted to the neurosurgical clinic for penetrating traumatic brain injuries between February, 2022 and July, 2024, for whom both cerebral multidetector computed tomography angiography (MCTA) and digital cerebral angiography (DCA) were available. The inclusion were patients (1) with penetrating head injuries, (2) with missile trajectory traverses through the Sylvian or great longitudinal fissure, (3) basal cisterns with/or major subarachnoid hemorrhage. The sensitivity, specificity, positive predictive value, and negative predictive value of MCTA were calculated. DCA was considered as the gold standard of diagnosis. The sensitivity, specificity, positive predictive value, and negative predictive value of MCTA were calculated. Descriptive statistics and nonparametric statistics were used to analyze the study results and their differences, respectively.
RESULTS:
A total of 40 patients with 45 TAs were included in the study. Of these, 26 patients (65.0%) were found to have aneurysms on MCTA. The median diameter of the aneurysms diagnosed by MCTA was 4.9 (3.6, 4.8) mm (range of 2.5 - 10.4 mm). However, the mean diameter of TAs not detected by MCTA but diagnosed by DCA was (3.0 ± 1.3) mm (range of 1.3 - 4.9 mm). MCTA demonstrated sensitivity and specificity of 35.5% and 99.5%, respectively, with positive and negative predictive values of 92.3% and 90.7%.
CONCLUSIONS
A low sensitivity of MCTA for the diagnosis of TAs associated with combat-related penetrating head injuries was reported. When MCTA is inconclusive in the setting of radiologic predictors of cerebral artery injury, DSA may be required.
Humans
;
Male
;
Retrospective Studies
;
Adult
;
Multidetector Computed Tomography/methods*
;
Intracranial Aneurysm/etiology*
;
Computed Tomography Angiography/methods*
;
Female
;
Head Injuries, Penetrating/diagnostic imaging*
;
Middle Aged
;
Cerebral Angiography/methods*
;
Predictive Value of Tests
;
Sensitivity and Specificity
;
Young Adult
10.Clinical application of single-balloon and double-balloon enteroscopy in pediatric small bowel diseases: a retrospective study of 576 cases.
Can-Lin LI ; Jie-Yu YOU ; Yan-Hong LUO ; Hong-Juan OU-YANG ; Li LIU ; Wen-Ting ZHANG ; Jia-Qi DUAN ; Na JIANG ; Mei-Zheng ZHAN ; Chen-Xi LIU ; Juan ZHOU ; Ling-Zhi YUAN ; Hong-Mei ZHAO
Chinese Journal of Contemporary Pediatrics 2025;27(7):822-828
OBJECTIVES:
To evaluate the effectiveness of single-balloon and double-balloon enteroscopy in diagnosing pediatric small bowel diseases and assess the diagnostic efficacy of computed tomography enterography (CTE) for small bowel diseases using enteroscopy as the reference standard.
METHODS:
Clinical data from 576 children who underwent enteroscopy at Hunan Children's Hospital between January 2017 and December 2023 were retrospectively collected. The children were categorized based on enteroscopy type into the single-balloon enteroscopy (SBE) group (n=457) and double-balloon enteroscopy (DBE) group (n=119), and the clinical data were compared between the two groups. The sensitivity and specificity of CTE for diagnosing small bowel diseases were evaluated using enteroscopy results as the standard.
RESULTS:
Among the 576 children, small bowel lesions were detected by enteroscopy in 274 children (47.6%).There was no significant difference in lesion detection rates or complication rates between the SBE and DBE groups (P>0.05), but the DBE group had deeper insertion, longer procedure time, and higher complete small bowel examination rate (P<0.05). The complication rate during enteroscopy was 4.3% (25/576), with 18 cases (3.1%) of mild complications and 7 cases (1.2%) of severe complications, which improved with symptomatic treatment, surgical, or endoscopic intervention. Among the 412 children who underwent CTE, the sensitivity and specificity for diagnosing small bowel diseases were 44.4% and 71.3%, respectively.
CONCLUSIONS
SBE and DBE have similar diagnostic efficacy for pediatric small bowel diseases, but DBE is preferred for suspected deep small bowel lesions and comprehensive small bowel examination. Enteroscopy in children demonstrates relatively good overall safety. CTE demonstrates relatively low sensitivity but comparatively high specificity for diagnosing small bowel diseases.
Retrospective Studies
;
Treatment Outcome
;
Double-Balloon Enteroscopy/statistics & numerical data*
;
Single-Balloon Enteroscopy/statistics & numerical data*
;
Humans
;
Male
;
Female
;
Child
;
Operative Time
;
Tomography, X-Ray Computed/statistics & numerical data*
;
Sensitivity and Specificity
;
Intestine, Small/surgery*
;
Intestinal Diseases/surgery*


Result Analysis
Print
Save
E-mail