1.A cultural values model of pakikipag-ugnayan: Examining hiya, pakikisama, and pakikipag-ugnayan among Filipino generation Z nurses.
Angelika B. AVILA ; Francis Oliver M. ALDABA ; Maryjoy Loraine T. ALMONTE ; Enrique B. ALZATE ; Trisha B. AMITA ; Ma. Andrea M. AVILA ; Zg Jungco A. ASOY ; Tristan Jourdan C. DELA CRUZ
Acta Medica Philippina 2026;60(9):91-99
OBJECTIVES
This study explored the interplay of three Filipino cultural values—hiya (modesty/self-restraint), pakikisama (conflict-avoidance dimension of social harmony), and pakikipag-ugnayan (professional engagement, characterized by vigor, dedication, and absorption)—among Generation Z nurses in Quezon City. Specifically, it assessed their levels, examined interrelationships through correlation and path analysis, and developed a framework to illustrate their influence on nursing practice. In the Filipino context, hiya encompasses both positive dimensions, such as conscientiousness, moral accountability, and social responsibility, and constraining dimensions, including excessive self-restraint, fear of criticism, and inhibition. Pakikisama, while fostering harmony, may discourage assertiveness and limit open communication. Pakikipag-ugnayan, conceptualized here as engagement, reflects dedication, vigor, and absorption, which are vital for performance, patient safety, and workforce retention.
METHODSA descriptive–correlational design was utilized to assess the relationships among hiya, pakikisama, and pakikipag-ugnayan. Data were gathered through a structured, self-administered questionnaire comprising validated scales for each construct, distributed in online formats to accommodate participants’ availability and work schedules. The purposive sample consisted of 115 Filipino Generation Z nurses engaged in direct patient care in various healthcare facilities in Quezon City. Data analysis involved descriptive statistics to summarize variable scores, Spearman’s rho to examine bivariate correlations, and path analysis to determine the direct and indirect effects among the variables. The results of the path analysis were used to develop a proposed framework illustrating the interplay of these cultural values in nursing practice.
RESULTSPath analysis revealed distinct patterns in the interplay of hiya, pakikisama, and pakikipag-ugnayan among Generation Z nurses in Quezon City. Very high hiya scores (mean = 5.32) reflected both moral accountability and restraint-oriented tendencies. Despite these positive indicators, hiya showed a negative correlation with pakikipag-ugnayan, suggesting that its inhibiting side—marked by fear of criticism and avoidance of mistakes—may overshadow its constructive moral aspects. In contrast, the path analysis identified a moderate positive direct effect between hiya and pakikipag-ugnayan (β = 0.400, pCONCLUSION
Among Generation Z nurses, hiya demonstrates a dual role: while its ethical and conscientious aspects can strengthen pakikipag-ugnayan, its inhibiting side may suppress pakikipag-ugnayan. Pakikisama, operationalized as conflict avoidance and withholding dissent, emerged as a barrier to pakikipag-ugnayan by discouraging open communication. These findings informed the development of the Hiya–Pakikisama– Pakikipag-ugnayan Cultural Dynamics Framework, which illustrates how cultural values can simultaneously enable and constrain professional engagement. The framework has potential applications in nursing education and organizational practice, particularly in designing reflective learning, mentorship, and communication strategies that balance cultural sensitivity with assertiveness. Further validation across generations and healthcare settings is recommended to refine its applicability.
Human ; Weights And Measures ; Sensitivity And Specificity ; Retention (psychology) ; Education, Nursing ; Social Responsibility ; Appointments And Schedules ; Conflict (psychology)
2.The diagnostic performance of nuchal translucency alone as a screening test for Down syndrome: A systematic review and meta-analysis.
Ma. Sergia Fatima P. SUCALDITO ; John Jefferson V. BESA ; Lia M. PALILEO-VILLANUEVA
Acta Medica Philippina 2025;59(15):7-23
BACKGROUND
Down syndrome or trisomy 21, the most common chromosomal disorder, results from the presence of a third copy of chromosome 21 and manifests as mild to moderate intellectual disability, growth retardation, congenital heart defects, gastrointestinal abnormalities, and characteristic facial features. Several methods have been used to screen for Down syndrome in the prenatal period, such as ultrasound, biomarkers, cell-free DNA testing, and combinations of these tests. A positive result from one or more of these screening tests signals the need for confirmatory karyotyping to clinch the diagnosis. Ultrasound between 11 to 14 weeks of gestation can evaluate nuchal translucency (NT) to screen for Down syndrome. During the second trimester, a triple or quadruple test can also be performed alone or in addition to NT to quantify Down syndrome risk. In limited resource settings however, only the measurement of NT via ultrasound can be performed since biomarker tests are either unavailable or inaccessible. While the diagnostic performance of NT measurement alone has been investigated in several observational studies, there is no consensus on its performance as a sole test to screen for Down syndrome.
OBJECTIVETo determine the diagnostic performance of NT during prenatal first-trimester ultrasound as a screening test for Down syndrome.
METHODSWe performed a systematic search on the PubMed, ProQuest, and Cochrane Library databases for recent systematic reviews and meta-analyses that addressed the objective. The existing reviews found were then independently appraised by the two reviewers with the AMSTAR-2 checklist. To update the existing reviews, a systematic search was done in the same databases to identify additional primary diagnostic studies, which were appraised using the QUADAS-2 tool. Random-effects univariate meta-analysis and summary receiving operator curve (HSROC) analysis for the outcomes were performed using Review Manager version 5.4 and R version 4.2.2, respectively. Subgroup analysis was performed by stratifying the baseline risk of mothers for fetal anomaly as low- or high-risk. Highrisk mothers were defined as women with risk factors such as advanced age, positive serum screen, presence of other ultrasound anomalies, and history of previous fetus with anomaly.
RESULTSWe found 22 cohort studies (n=225,846) of women at low-risk for fetal anomaly. The pooled sensitivity was 67.8% (95% CI: 61.4%-73.6%, I2=70.4%) and specificity was 96.3% (95% CI: 95.5%-96.9%, I2=96.7%). For low-risk women, the overall certainty of evidence was low, due to different modes of verification and heterogeneity not completely explained by variability in baseline risk or cut-points. Seven studies (n=9,197) were on high-risk women. The pooled sensitivity was 62.2% (95% CI: 54.1%-69.7%, I2=38.8%) and specificity was 96.5% (95% CI: 93.6%-98.1%, I2=95.5%). For women at high-risk, the evidence was rated as moderate due to differential verification.
CONCLUSIONOur analysis showed that NT measured through first-trimester ultrasound is specific for Down syndrome but has low sensitivity. Despite this, it is a useful screening test for Down syndrome in low-resource settings where other strategies may not be available or accessible. Furthermore, interpretation of NT results must take into consideration its limited sensitivity as this may lead to missed cases.
Human ; Nuchal Translucency Measurement ; Down Syndrome ; Sensitivity And Specificity
3.A machine learning approach for the diagnosis of obstructive sleep apnoea using oximetry, demographic and anthropometric data.
Zhou Hao LEONG ; Shaun Ray Han LOH ; Leong Chai LEOW ; Thun How ONG ; Song Tar TOH
Singapore medical journal 2025;66(4):195-201
INTRODUCTION:
Obstructive sleep apnoea (OSA) is a serious but underdiagnosed condition. Demand for the gold standard diagnostic polysomnogram (PSG) far exceeds its availability. More efficient diagnostic methods are needed, even in tertiary settings. Machine learning (ML) models have strengths in disease prediction and early diagnosis. We explored the use of ML with oximetry, demographic and anthropometric data to diagnose OSA.
METHODS:
A total of 2,996 patients were included for modelling and divided into test and training sets. Seven commonly used supervised learning algorithms were trained with the data. Sensitivity (recall), specificity, positive predictive value (PPV) (precision), negative predictive value, area under the receiver operating characteristic curve (AUC) and F1 measure were reported for each model.
RESULTS:
In the best performing four-class model (neural network model predicting no, mild, moderate or severe OSA), a prediction of moderate and/or severe disease had a combined PPV of 94%; one out of 335 patients had no OSA and 19 had mild OSA. In the best performing two-class model (logistic regression model predicting no-mild vs. moderate-severe OSA), the PPV for moderate-severe OSA was 92%; two out of 350 patients had no OSA and 26 had mild OSA.
CONCLUSION
Our study showed that the prediction of moderate-severe OSA in a tertiary setting with an ML approach is a viable option to facilitate early identification of OSA. Prospective studies with home-based oximeters and analysis of other oximetry variables are the next steps towards formal implementation.
Humans
;
Oximetry/methods*
;
Sleep Apnea, Obstructive/diagnosis*
;
Male
;
Female
;
Middle Aged
;
Machine Learning
;
Polysomnography
;
Adult
;
Anthropometry
;
ROC Curve
;
Aged
;
Algorithms
;
Predictive Value of Tests
;
Sensitivity and Specificity
;
Neural Networks, Computer
;
Demography
4.Deploying artificial intelligence in the detection of adult appendicular and pelvic fractures in the Singapore emergency department after hours: efficacy, cost savings and non-monetary benefits.
John Jian Xian QUEK ; Oliver James NICKALLS ; Bak Siew Steven WONG ; Min On TAN
Singapore medical journal 2025;66(4):202-207
INTRODUCTION:
Radiology plays an integral role in fracture detection in the emergency department (ED). After hours, when there are fewer reporting radiologists, most radiographs are interpreted by ED physicians. A minority of these interpretations may miss diagnoses, which later require the callback of patients for further management. Artificial intelligence (AI) has been viewed as a potential solution to augment the shortage of radiologists after hours. We explored the efficacy of an AI solution in the detection of appendicular and pelvic fractures for adult radiographs performed after hours at a general hospital ED in Singapore, and estimated the potential monetary and non-monetary benefits.
METHODS:
One hundred and fifty anonymised abnormal radiographs were retrospectively collected and fed through an AI fracture detection solution. The radiographs were re-read by two radiologist reviewers and their consensus was established as the reference standard. Cases were stratified based on the concordance between the AI solution and the reviewers' findings. Discordant cases were further analysed based on the nature of the discrepancy into overcall and undercall subgroups. Statistical analysis was performed to evaluate the accuracy, sensitivity and inter-rater reliability of the AI solution.
RESULTS:
Ninety-two examinations were included in the final study radiograph set. The AI solution had a sensitivity of 98.9%, an accuracy of 85.9% and an almost perfect agreement with the reference standard.
CONCLUSION
An AI fracture detection solution has similar sensitivity to human radiologists in the detection of fractures on ED appendicular and pelvic radiographs. Its implementation offers significant potential measurable cost, manpower and time savings.
Humans
;
Singapore
;
Emergency Service, Hospital
;
Fractures, Bone/diagnostic imaging*
;
Artificial Intelligence
;
Retrospective Studies
;
Adult
;
Male
;
Female
;
Cost Savings
;
Middle Aged
;
Pelvic Bones/diagnostic imaging*
;
Reproducibility of Results
;
Aged
;
Sensitivity and Specificity
;
Radiography
5.The diagnostic performance of nuchal translucency alone as a screening test for Down syndrome: A systematic review and meta-analysis
Ma. Sergia Fatima P. Sucaldito ; John Jefferson V. Besa ; Lia M. Palileo-villanueva
Acta Medica Philippina 2025;59(Early Access 2025):1-17
BACKGROUND
Down syndrome or trisomy 21, the most common chromosomal disorder, results from the presence of a third copy of chromosome 21 and manifests as mild to moderate intellectual disability, growth retardation, congenital heart defects, gastrointestinal abnormalities, and characteristic facial features. Several methods have been used to screen for Down syndrome in the prenatal period, such as ultrasound, biomarkers, cell-free DNA testing, and combinations of these tests. A positive result from one or more of these screening tests signals the need for confirmatory karyotyping to clinch the diagnosis. Ultrasound between 11 to 14 weeks of gestation can evaluate nuchal translucency (NT) to screen for Down syndrome. During the second trimester, a triple or quadruple test can also be performed alone or in addition to NT to quantify Down syndrome risk. In limited resource settings however, only the measurement of NT via ultrasound can be performed since biomarker tests are either unavailable or inaccessible. While the diagnostic performance of NT measurement alone has been investigated in several observational studies, there is no consensus on its performance as a sole test to screen for Down syndrome.
OBJECTIVETo determine the diagnostic performance of NT during prenatal first-trimester ultrasound as a screening test for Down syndrome.
METHODSWe performed a systematic search on the PubMed, ProQuest, and Cochrane Library databases for recent systematic reviews and meta-analyses that addressed the objective. The existing reviews found were then independently appraised by the two reviewers with the AMSTAR-2 checklist. To update the existing reviews, a systematic search was done in the same databases to identify additional primary diagnostic studies, which were appraised using the QUADAS-2 tool. Random-effects univariate meta-analysis and summary receiving operator curve (HSROC) analysis for the outcomes were performed using Review Manager version 5.4 and R version 4.2.2, respectively. Subgroup analysis was performed by stratifying the baseline risk of mothers for fetal anomaly as low- or high-risk. Highrisk mothers were defined as women with risk factors such as advanced age, positive serum screen, presence of other ultrasound anomalies, and history of previous fetus with anomaly.
RESULTSWe found 22 cohort studies (n=225,846) of women at low-risk for fetal anomaly. The pooled sensitivity was 67.8% (95% CI: 61.4%-73.6%, I2=70.4%) and specificity was 96.3% (95% CI: 95.5%-96.9%, I2=96.7%). For low-risk women, the overall certainty of evidence was low, due to different modes of verification and heterogeneity not completely explained by variability in baseline risk or cut-points. Seven studies (n=9,197) were on high-risk women. The pooled sensitivity was 62.2% (95% CI: 54.1%-69.7%, I2=38.8%) and specificity was 96.5% (95% CI: 93.6%-98.1%, I2=95.5%). For women at high-risk, the evidence was rated as moderate due to differential verification.
CONCLUSIONOur analysis showed that NT measured through first-trimester ultrasound is specific for Down syndrome but has low sensitivity. Despite this, it is a useful screening test for Down syndrome in low-resource settings where other strategies may not be available or accessible. Furthermore, interpretation of NT results must take into consideration its limited sensitivity as this may lead to missed cases.
Human ; Nuchal Translucency Measurement ; Down Syndrome ; Sensitivity And Specificity
6.Diagnostic value of 99mTc-MDP three-phase bone scintigraphy combined with C-reaction protein for periprosthetic joint infection.
Guojie LIU ; Xiaolan SONG ; Pei ZHAI ; Shipeng SONG ; Weidong BAO ; Yawei DUAN ; Wei ZHANG ; Yafeng LIU ; Yongqiang SUN ; Shuailei LI
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(9):1180-1186
OBJECTIVE:
To investigate the diagnostic efficacy of 99mTc-MDP three-phase bone scintigraphy (TPBS) combined with C-reactive protein (CRP) for periprosthetic joint infection (PJI).
METHODS:
The clinical data of 198 patients who underwent revision surgery of artificial joint between January 2017 and January 2024 and received TPBS examination before surgery were retrospectively analyzed. There were 77 males and 121 females with an average age of 63.74 years ranging from 24 to 92 years. There were 90 cases of hip arthroplasty and 108 cases of knee arthroplasty. PJI was diagnosed according to the 2013 American Musculoskeletal Infection Society (MSIS) standard diagnostic criteria. The sensitivity, specificity, accuracy, negative predictive value (NPV), and positive predict value (PPV) were calculated. The receiver operating characteristic (ROC) curve was used to compare the diagnostic performance of the three methods, and the area under curve (AUC) was used to evaluate the diagnostic performance.
RESULTS:
According to the 2013 MSIS criteria, 116 cases were diagnosed as PJI, and the remaining 82 cases were aseptic loosening. The cases of PJI diagnosed by TPBS, CRP, and TPBS-CRP were 125, 109, and 137 respectively, and the cases of aseptic loosening were 73, 89, and 61 respectively. The sensitivity, accuracy, NPV, and PPV of TPBS-CRP combination in the diagnosis of PJI were higher than those of TPBS and CRP, but the specificity was lower than that of TPBS and CRP. ROC curve analysis further showed that the AUC value of TPBS-CRP combination was better than that of TPBS and CRP. The severity of bone defect and the duration of symptoms in patients with false positive TPBS diagnosis were worse than those in patients with true negative TPBS diagnosis (P<0.05), but there was no significant difference in the survival time of prosthesis between the two groups (P>0.05). Among the patients diagnosed with PJI by TPBS, CRP, and TPBS-CRP, 49, 35, and 54 patients had received antibiotic treatment 2 weeks before diagnosis, respectively. There was no significant difference in the diagnostic accuracy of TPBS and TPBS-CRP before diagnosis between patients treated with and without antibiotics and those not treated (P>0.05). The diagnostic accuracy of antibiotic therapy before CRP diagnosis was significantly lower than that of untreated patients (P<0.05).
CONCLUSION
TPBS and CRP have limited specificity in differentiating PJI from aseptic loosening. The TPBS-CRP combination diagnostic method can synergize the local bone metabolic characteristics and systemic inflammatory response to achieve higher diagnostic accuracy, but caution should be exercised in patients with severe bone defects and longer symptom duration.
Humans
;
Prosthesis-Related Infections/blood*
;
Middle Aged
;
Male
;
Female
;
Aged
;
C-Reactive Protein/metabolism*
;
Retrospective Studies
;
Adult
;
Radionuclide Imaging/methods*
;
Arthroplasty, Replacement, Knee/adverse effects*
;
Aged, 80 and over
;
Technetium Tc 99m Medronate
;
Arthroplasty, Replacement, Hip/adverse effects*
;
Sensitivity and Specificity
;
Knee Prosthesis/adverse effects*
;
ROC Curve
;
Reoperation
;
Radiopharmaceuticals
;
Young Adult
7.Comparative study on accuracy of three imaging methods in diagnosis of subacromial impingement syndrome.
Linfeng ZI ; Hongfu JIN ; Jianwei ZHU ; Guoxu ZHANG ; Yao TONG ; Sijie CHEN ; Wenze SHAO ; Xin TANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(10):1290-1295
OBJECTIVE:
To compare the diagnostic accuracy of supraspinatus muscle outlet X-ray film, oblique sagittal multislice helical CT (MSCT), and oblique sagittal MRI in the diagnosis of subacromial impingement syndrome (SIS).
METHODS:
A retrospective analysis was conducted on the imaging data of 106 patients diagnosed with SIS between January 2023 and December 2024. The cohort consisted of 32 males and 74 females, with ages ranging from 43 to 70 years (mean, 60.19 years). All patients underwent supraspinatus muscle outlet X-ray film, MSCT, and MRI scans, with MSCT further subjected to three-dimensional reconstruction. Two experienced radiologists independently evaluated the acromion morphology in each imaging modality using the Bigliani classification system. Inter-observer reliability was assessed via Kappa statistics. The CT three-dimensional reconstructions were used as the "gold standard". The overall consistency, Kappa values, sensitivity, and specificity of the three imaging modalities were calculated. Receiver operating characteristic (ROC) curves were plotted, and the area under the curve (AUC) was computed.
RESULTS:
The inter-observer reliability for supraspinatus muscle outlet X-ray film, oblique sagittal MSCT, and oblique sagittal MRI was moderate, with Kappa values of 0.62, 0.63, and 0.55, respectively. When compared to the CT three-dimensional reconstructions as the "gold standard", the overall consistency was 88.7% (94/106), 62.3% (66/106), and 58.5% (62/106), respectively. The supraspinatus muscle outlet X-ray film showed excellent consistency (Kappa=0.77), whereas the consistency of MSCT and MRI was lower (Kappa=0.34 and 0.29, respectively). In terms of diagnostic sensitivity and specificity, the supraspinatus muscle outlet X-ray film outperformed oblique sagittal MSCT and oblique sagittal MRI in distinguishing various acromion types. ROC analysis demonstrated that the AUC for the supraspinatus muscle outlet X-ray film was consistently higher than for oblique sagittal MSCT and oblique sagittal MRI, with the highest diagnostic performance observed for type Ⅲ hooked acromion (AUC=0.939).
CONCLUSION
Supraspinatus muscle outlet X-ray film provides the highest diagnostic accuracy for acromion classification in SIS patients, particularly in identifying type Ⅲ hooked acromion, which is strongly associated with SIS. Given its superior sensitivity and consistency, it should be considered the primary screening tool. MSCT and MRI serve as valuable supplementary modalities for complex cases and preoperative evaluation.
Humans
;
Middle Aged
;
Male
;
Female
;
Shoulder Impingement Syndrome/diagnostic imaging*
;
Magnetic Resonance Imaging/methods*
;
Retrospective Studies
;
Aged
;
Adult
;
Imaging, Three-Dimensional
;
Sensitivity and Specificity
;
Tomography, Spiral Computed/methods*
;
Multidetector Computed Tomography/methods*
;
Reproducibility of Results
8.Machine learning to risk stratify chest pain patients with non-diagnostic electrocardiogram in an Asian emergency department.
Ziwei LIN ; Tar Choon AW ; Laurel JACKSON ; Cheryl Shumin KOW ; Gillian MURTAGH ; Siang Jin Terrance CHUA ; Arthur Mark RICHARDS ; Swee Han LIM
Annals of the Academy of Medicine, Singapore 2025;54(4):219-226
INTRODUCTION:
Elevated troponin, while essential for diagnosing myocardial infarction, can also be present in non-myocardial infarction conditions. The myocardial-ischaemic-injury-index (MI3) algorithm is a machine learning algorithm that considers age, sex and cardiac troponin I (TnI) results to risk-stratify patients for type 1 myocardial infarction.
METHOD:
Patients aged ≥25 years who presented to the emergency department (ED) of Singapore General Hospital with symptoms suggestive of acute coronary syndrome with no diagnostic 12-lead electrocardiogram (ECG) changes were included. Participants had serial ECGs and high-sensitivity troponin assays performed at 0, 2 and 7 hours. The primary outcome was the adjudicated diagnosis of type 1 myocardial infarction at 30 days. We compared the performance of MI3 in predicting the primary outcome with the European Society of Cardiology (ESC) 0/2-hour algorithm as well as the 99th percentile upper reference limit (URL) for TnI.
RESULTS:
There were 1351 patients included (66.7% male, mean age 56 years), 902 (66.8%) of whom had only 0-hour troponin results and 449 (33.2%) with serial (both 0 and 2-hour) troponin results available. MI3 ruled out type 1 myocardial infarction with a higher sensitivity (98.9, 95% confidence interval [CI] 93.4-99.9%) and similar negative predictive value (NPV) 99.8% (95% CI 98.6-100%) as compared to the ESC strategy. The 99th percentile cut-off strategy had the lowest sensitivity, specificity, positive predictive value and NPV.
CONCLUSION
The MI3 algorithm was accurate in risk stratifying ED patients for myocardial infarction. The 99th percentile URL cut-off was the least accurate in ruling in and out myocardial infarction compared to the other strategies.
Humans
;
Male
;
Female
;
Emergency Service, Hospital
;
Middle Aged
;
Electrocardiography
;
Machine Learning
;
Singapore
;
Chest Pain/blood*
;
Troponin I/blood*
;
Myocardial Infarction/blood*
;
Risk Assessment/methods*
;
Aged
;
Algorithms
;
Acute Coronary Syndrome/blood*
;
Adult
;
Sensitivity and Specificity
9.A truncated N protein-based ELISA method for the detection of antibodies against porcine deltacoronavirus.
Dongsheng WANG ; Ruiming YU ; Liping ZHANG ; Yingjie BAI ; Xia LIU ; Yonglu WANG ; Xiaohua DU ; Xinsheng LIU
Chinese Journal of Biotechnology 2025;41(7):2760-2773
This study aims to establish an antibody detection method for porcine deltacoronavirus (PDCoV). The recombinant proteins PDCoV-N1 and PDCoV-N2 were expressed via the prokaryotic plasmid pColdII harboring the N gene sequence of the PDCoV strain CH/XJYN/2016. The reactivity and specificity of PDCoV-N1 and PDCoV-N2 with anti-PEDV sera were analyzed after the recombinant proteins were analyzed by SDS-PAGE and purified by the Ni-NTA Superflow Cartridge. Meanwhile, Western blotting and indirect immunofluorescence assay were carried out separately to validate the recombinant proteins PDCoV-N1 and PDCoV-N2. Finally, we established an indirect ELISA method based on the recombinant protein PDCoV-N2 after optimizing the conditions and tested the sensitivity, specificity, and reproducibility of the method. Then, the established method was employed to examine 102 clinical serum samples. The recombinant protein PDCoV-N2 showed low cross-reactivity with anti-PEDV sera. The optimal conditions of the indirect ELISA method based on PDCoV-N2 were as follows: the antigen coating concentration of 1.25 μg/mL and coating at 37 ℃ for 1 h; blocking by BSA overnight at 4 ℃; serum sample dilution at 1:50 and incubation at 37 ℃ for 1 h; secondary antibody dilution at 1:80 000 and incubation at 37 ℃ for 1 h; color development with TMB chromogenic solution at 37 ℃ for 10 min. The S/P value ≥ 0.45, ≤0.38, and between 0.45 and 0.38 indicated that the test sample was positive, negative, and suspicious, respectively. The testing results of the antisera against porcine epidemic diarrhea virus (PEDV), porcine circovirus 2 (PCV2), transmissible gastroenteritis virus (TGEV), foot-and-mouth disease virus (FMDV), and African swine fever virus (ASFV) showed that the S/P values were all less than 0.38. The testing results of the 800-fold diluted anti-PDCoV sera were still positive. The results of the inter- and intra-batch tests showed that the coefficients of variation of this method were less than 10%. Clinical serum sample test results showed the coincidence rate between this method and neutralization test was 94.12%. In this study, an ELISA method for the detection of anti-PDCoV antibodies was successfully established based on the truncated N protein of PDCoV. This method is sensitive, specific, stable, and reproducible, serving as a new method for the clinical diagnosis of PDCoV.
Animals
;
Enzyme-Linked Immunosorbent Assay/methods*
;
Swine
;
Antibodies, Viral/blood*
;
Recombinant Proteins/genetics*
;
Deltacoronavirus/isolation & purification*
;
Coronavirus Infections/virology*
;
Swine Diseases/diagnosis*
;
Coronavirus Nucleocapsid Proteins
;
Sensitivity and Specificity
10.Lymphatic and Venous Contrast-Enhanced Ultrasound Imaging for Differential Diagnosis of Cervical Lymph Node Metastasis in Thyroid Cancer.
Li XU ; Wen-Bo WAN ; Tian GAO ; Tao-Hua GOU ; Yan ZHANG
Acta Academiae Medicinae Sinicae 2025;47(1):16-22
Objective To investigate the value of the novel lymphatic contrast-enhanced ultrasound(LCEUS)and conventional venous contrast-enhanced ultrasound(VCEUS)in the differential diagnosis of benign and malignant cervical lymph nodes in patients with thyroid cancer. Methods Patients with suspected thyroid cancer underwent conventional ultrasound,VCEUS,and LCEUS examinations of cervical lymph nodes before biopsy.The diagnostic abilities of conventional ultrasound,VCEUS,and LCEUS were compared with pathological results as the golden standard. Results Forty-four patients with 52 lymph nodes were included in the final data.Thirty-eight metastatic lymph nodes were confirmed by pathological results,and 14 were benign.The diagnostic sensitivity,specificity,and accuracy were 97.37%,71.43%,and 90.38% for LCEUS,92.11%,35.71%,and 76.92% for VCEUS,and 94.74%,21.43%,and 75.00% for conventional ultrasound,respectively.The area under the curve of LCEUS analyzed by the receiver operating characteristic curve was greater than that of VCEUS(P=0.020)and conventional ultrasound(P<0.001). Conclusion LCEUS could significantly improve the differential diagnosis of cervical lymph node metastasis in the patients with thyroid cancer,providing a basis for precise clinical treatment.
Humans
;
Thyroid Neoplasms/diagnostic imaging*
;
Lymphatic Metastasis/diagnostic imaging*
;
Diagnosis, Differential
;
Female
;
Male
;
Middle Aged
;
Ultrasonography
;
Adult
;
Lymph Nodes/pathology*
;
Contrast Media
;
Neck
;
Aged
;
Young Adult
;
Adolescent
;
Sensitivity and Specificity


Result Analysis
Print
Save
E-mail