1.Research on Organizational Inert in Medical Quality and Safety Management and Preventive Strategies
Longjun HU ; Jianhua HUANG ; Ruo JIANG ; Luyang HE ; Jialin YANG ; Keqiang ZUO ; Lengchen HOU
Chinese Hospital Management 2025;45(3):55-59
In the dynamic process of organizational development,organizations tend to exhibit a tendency towards organizational inertia by maintaining its original behavior patterns.It introduces organizational inertia theory into the medical management.Based on the concept of organizational inertia,the concept of organizational inertia in medical quality and safety management was proposed.From the perspective of connotation of organizational inertia in medical quality and safety management,its essence was the failure of medical institutions to implement or achieve continuous improvement in medical standardized behavior.From the perspective of denotation,it includes six categories:structural inertia,institutional inertia,resource inertia,technological inertia,employee inertia,and cultural inertia.In addition,it explored how to overcome organizational inertia in medical quality and safety management,which can provide new ideas for sustainably improvement research and practice in medical quality and safety management.
2.Influence of helical tomography radiotherapy planning parameters on threading effect
Ruo-qi CAO ; Xia-yu HANG ; Hua HUANG ; Xian-qiang SONG ; Jin-da ZHOU ; Yun-jie BAI ; Xiang-dong SUN ; Yi-kun LI
Chinese Medical Equipment Journal 2025;46(8):58-66
Objective To investigate the influence of helical tomographic radiotherapy plans with different combinations of lead gate width,pitch and algorithms on threading effects.Methods A target model was established with a Cheese Phantom used as the simulated human body,then three lead gate widths(1.0,2.5,and 5.0 cm),six screw pitches(0.143,0.172,0.215,0.287,0.430,and 0.500)and two computational grids(Fine algorithm and Normal algorithm)were respectively combined for designing the helical tomography radiotherapy plans.The radiotherapy plans with a pitch of 0.143,0.172,0.215,0.287 or 0.430 were enrolled into an experimental group,and the plans with a pitch of 0.500 were divided into a control group.The dosimetric parameters including maximum dose(Dmax),minimum dose(Dmin)and mean dose(Dmean)of the target area PTV1 and PTV2 were evaluated by the dose volume histogram(DVH).The dose homogeneity index(HI)of the target area was calculated,and the single rotation time and total treatment time of each plan were recorded and counted.SPSS 27.0 software was used for statistical analysis.Results No significant threading effect appeared regardless of the pitch value when the lead gate width was 1.0 cm.The threading effects in the experimental group were weaker than those in the control group when the lead gate width was 2.5 or 5.0 cm.The threading effect gradually rose with the pitch increased when the lead gate width was 5.0 cm.The most significant difference was found between the threading effect in case of the screw pitch being 0.500 and that with the screw pitch being 0.143,with the differenes being statistically obvious(P<0.05).The lead gate width had significant effects on the Dmax,Dmin,Dmean and HI of PTV1 and PTV2.When the lead gate width was 5.0 cm,high HI value and uneven dose distribution were detected and lowered screw pitch weakened the threading effect.The single rotation time first remained constant and then increased with the screw pitch was enlarged,with the changing points occurring in case of the screw pitches of 0.287 and 0.430.With a certain lead gate width,the treatment time for plans was shortened with the decrease of the pitches in case of the pritches lower than 0.287,and tended to be constant after the screw pitches reached 0.287.The changes of the computational grid had no significant effects on the results of radiotherapy plans when the lead gate width and screw pitch were kept constant.Conclusion When designing a spiral tomotherapy plan with conventional doses,a lead gate width of 1.0 or 2.5 cm and a screw pitch of 0.287 or 0.430 should be selected in order to minimize the threading effect while ensuring the efficiency of plan implementation.[Chinese Medical Equipment Journal,2025,46(8):58-66]
3.Diffusion status and characteristics of life expectancy and healthy life expectancy policies(1982-2024)in China:Based on the perspective of policy bibliometric
Yu-fei WANG ; Lie-yu HUANG ; Ruo-yao HUANG ; Na-na LIU ; Heng-yu ZHAO ; Yan GUO
Chinese Journal of Health Policy 2025;18(8):10-19
Objective:To analyze the evolution and diffusion characteristics of policies related to life expectancy(LE)and healthy life expectancy(HLE)in China from 1982 to 2024 using a biometric approach to policy analysis,revealing the patterns of policy diffusion.Methods:By retrieving databases such as PKULAW.com,We comprehensively collected 701 policy documents closely related to LE and HLE during the period(including 62 central policies and 639 local policies),the policy diffusion process was quantified in four dimensions:diffusion intensity,diffusion breadth,diffusion speed and diffusion direction by using the policy—reference network analysis method.Results:Related policy has gone through the germination period(1982-2001),the development period(2002-2010),the rapid rise period(2011-2015)and the four stages of innovation and pioneering period(2016—present).Policy diffusion is influenced by the hierarchical level of the issuing institution,policy type,and regional economic development level.Policies promulgated by central institutions exhibit stronger and broader diffusion,with guideline—type policies diffusing most widely.The diffusion rate follows a trend of"initial growth,followed by deceleration,and then a slight increase."The primary diffusion directions are vertical diffusion from central to local levels and horizontal diffusion among peers.Conclusion:The diffusion of policies related to LE and HLE is characterized by significant stages,regions and levels.
4.Influence of helical tomography radiotherapy planning parameters on threading effect
Ruo-qi CAO ; Xia-yu HANG ; Hua HUANG ; Xian-qiang SONG ; Jin-da ZHOU ; Yun-jie BAI ; Xiang-dong SUN ; Yi-kun LI
Chinese Medical Equipment Journal 2025;46(8):58-66
Objective To investigate the influence of helical tomographic radiotherapy plans with different combinations of lead gate width,pitch and algorithms on threading effects.Methods A target model was established with a Cheese Phantom used as the simulated human body,then three lead gate widths(1.0,2.5,and 5.0 cm),six screw pitches(0.143,0.172,0.215,0.287,0.430,and 0.500)and two computational grids(Fine algorithm and Normal algorithm)were respectively combined for designing the helical tomography radiotherapy plans.The radiotherapy plans with a pitch of 0.143,0.172,0.215,0.287 or 0.430 were enrolled into an experimental group,and the plans with a pitch of 0.500 were divided into a control group.The dosimetric parameters including maximum dose(Dmax),minimum dose(Dmin)and mean dose(Dmean)of the target area PTV1 and PTV2 were evaluated by the dose volume histogram(DVH).The dose homogeneity index(HI)of the target area was calculated,and the single rotation time and total treatment time of each plan were recorded and counted.SPSS 27.0 software was used for statistical analysis.Results No significant threading effect appeared regardless of the pitch value when the lead gate width was 1.0 cm.The threading effects in the experimental group were weaker than those in the control group when the lead gate width was 2.5 or 5.0 cm.The threading effect gradually rose with the pitch increased when the lead gate width was 5.0 cm.The most significant difference was found between the threading effect in case of the screw pitch being 0.500 and that with the screw pitch being 0.143,with the differenes being statistically obvious(P<0.05).The lead gate width had significant effects on the Dmax,Dmin,Dmean and HI of PTV1 and PTV2.When the lead gate width was 5.0 cm,high HI value and uneven dose distribution were detected and lowered screw pitch weakened the threading effect.The single rotation time first remained constant and then increased with the screw pitch was enlarged,with the changing points occurring in case of the screw pitches of 0.287 and 0.430.With a certain lead gate width,the treatment time for plans was shortened with the decrease of the pitches in case of the pritches lower than 0.287,and tended to be constant after the screw pitches reached 0.287.The changes of the computational grid had no significant effects on the results of radiotherapy plans when the lead gate width and screw pitch were kept constant.Conclusion When designing a spiral tomotherapy plan with conventional doses,a lead gate width of 1.0 or 2.5 cm and a screw pitch of 0.287 or 0.430 should be selected in order to minimize the threading effect while ensuring the efficiency of plan implementation.[Chinese Medical Equipment Journal,2025,46(8):58-66]
5.Diffusion status and characteristics of life expectancy and healthy life expectancy policies(1982-2024)in China:Based on the perspective of policy bibliometric
Yu-fei WANG ; Lie-yu HUANG ; Ruo-yao HUANG ; Na-na LIU ; Heng-yu ZHAO ; Yan GUO
Chinese Journal of Health Policy 2025;18(8):10-19
Objective:To analyze the evolution and diffusion characteristics of policies related to life expectancy(LE)and healthy life expectancy(HLE)in China from 1982 to 2024 using a biometric approach to policy analysis,revealing the patterns of policy diffusion.Methods:By retrieving databases such as PKULAW.com,We comprehensively collected 701 policy documents closely related to LE and HLE during the period(including 62 central policies and 639 local policies),the policy diffusion process was quantified in four dimensions:diffusion intensity,diffusion breadth,diffusion speed and diffusion direction by using the policy—reference network analysis method.Results:Related policy has gone through the germination period(1982-2001),the development period(2002-2010),the rapid rise period(2011-2015)and the four stages of innovation and pioneering period(2016—present).Policy diffusion is influenced by the hierarchical level of the issuing institution,policy type,and regional economic development level.Policies promulgated by central institutions exhibit stronger and broader diffusion,with guideline—type policies diffusing most widely.The diffusion rate follows a trend of"initial growth,followed by deceleration,and then a slight increase."The primary diffusion directions are vertical diffusion from central to local levels and horizontal diffusion among peers.Conclusion:The diffusion of policies related to LE and HLE is characterized by significant stages,regions and levels.
6.Research on Organizational Inert in Medical Quality and Safety Management and Preventive Strategies
Longjun HU ; Jianhua HUANG ; Ruo JIANG ; Luyang HE ; Jialin YANG ; Keqiang ZUO ; Lengchen HOU
Chinese Hospital Management 2025;45(3):55-59
In the dynamic process of organizational development,organizations tend to exhibit a tendency towards organizational inertia by maintaining its original behavior patterns.It introduces organizational inertia theory into the medical management.Based on the concept of organizational inertia,the concept of organizational inertia in medical quality and safety management was proposed.From the perspective of connotation of organizational inertia in medical quality and safety management,its essence was the failure of medical institutions to implement or achieve continuous improvement in medical standardized behavior.From the perspective of denotation,it includes six categories:structural inertia,institutional inertia,resource inertia,technological inertia,employee inertia,and cultural inertia.In addition,it explored how to overcome organizational inertia in medical quality and safety management,which can provide new ideas for sustainably improvement research and practice in medical quality and safety management.
7.Preparation and performance evaluation of S100B time-resolved fluorescence immunoassay kit
Dong-Qing FENG ; Bu-Zhuo XU ; Shu-Hong LUO ; Yu-Nan WU ; Zhuo ZHANG ; Hao TANG ; Yi-Ming WENG ; Ruo-Pan HUANG ; Xu-Dong SONG
Chinese Medical Equipment Journal 2024;45(1):47-55
Objective To develop a time-resolved fluorescent immunoassay kit for the rapid,accurate and quantitative detection of S100B protein in serum and to evaluate its performance.Methods The test strip was prepared using time-resolved fluorescent microsphere-labeled anti-S100B polyclonal antibody and rabbit IgG antibody,labeling pads,sample pads,S100B nitrocellulose films and absorbent paper,and an S100B time-resolved fluorescence immunoassay kit was obtained by assembling the cartridge.The performance of the kit developed was evaluated by standard curve,accuracy,minimum detection limit,linear interval,specificity,reproducibility and stability.The reference intervals of 199 pieces of healthy human serum and plasma samples from a certain region were detected with the kit,and the clinical performance of the kit and Roche Elecsys S100 kit was tested by synchronous blind method to assess the consistency of the results of the two kits for 142 samples.Results The S100B time-resolved fluorescence immunoassay kit had the standard curve beingy=(1.133 02+1.752 24)/[1+(x/1.082 20)×(-0.603 52)]-1.752 24,R2=0.999 08 and the linear range being[0.05,30]ng/mL,which met the requirements of the relative deviation of the accuracy within±15%,the minimum detection limit not hgier than 0.05 ng/mL,the relative deviation of specificity within±15%and the coefficient of variation of intra-and inter-batch difference less than 15%.The stability test results indicated that the kit was valid for 12 months at 2-30 ℃ conditions.The reference intervals of serum and plasma samples measured by the kit were both lower than 0.3 ng/mL.Clinical trials showed that the results by the kit and Roche Elecsys S100 Assay Kit were in high agreement(Kappa=0.906 1>0.80)and met the requirements.Conclusion The kit developed detects the concentration of S100B protein in serum quickly,accurately and quantitatively,and provides references for the diagnosis and treatment of neurological diseases,autoimmune diseases,cerebrovascular diseases and etc.[Chinese Medical Equipment Journal,2024,45(1):47-55]
8.Correlation between Combined Urinary Metal Exposure and Grip Strength under Three Statistical Models: A Cross-sectional Study in Rural Guangxi
Jian Yu LIANG ; Hui Jia RONG ; Xiu Xue WANG ; Sheng Jian CAI ; Dong Li QIN ; Mei Qiu LIU ; Xu TANG ; Ting Xiao MO ; Fei Yan WEI ; Xia Yin LIN ; Xiang Shen HUANG ; Yu Ting LUO ; Yu Ruo GOU ; Jing Jie CAO ; Wu Chu HUANG ; Fu Yu LU ; Jian QIN ; Yong Zhi ZHANG
Biomedical and Environmental Sciences 2024;37(1):3-18
Objective This study aimed to investigate the potential relationship between urinary metals copper (Cu), arsenic (As), strontium (Sr), barium (Ba), iron (Fe), lead (Pb) and manganese (Mn) and grip strength. Methods We used linear regression models, quantile g-computation and Bayesian kernel machine regression (BKMR) to assess the relationship between metals and grip strength.Results In the multimetal linear regression, Cu (β=-2.119), As (β=-1.318), Sr (β=-2.480), Ba (β=0.781), Fe (β= 1.130) and Mn (β=-0.404) were significantly correlated with grip strength (P < 0.05). The results of the quantile g-computation showed that the risk of occurrence of grip strength reduction was -1.007 (95% confidence interval:-1.362, -0.652; P < 0.001) when each quartile of the mixture of the seven metals was increased. Bayesian kernel function regression model analysis showed that mixtures of the seven metals had a negative overall effect on grip strength, with Cu, As and Sr being negatively associated with grip strength levels. In the total population, potential interactions were observed between As and Mn and between Cu and Mn (Pinteractions of 0.003 and 0.018, respectively).Conclusion In summary, this study suggests that combined exposure to metal mixtures is negatively associated with grip strength. Cu, Sr and As were negatively correlated with grip strength levels, and there were potential interactions between As and Mn and between Cu and Mn.
9.Research advance of clinical application of X-ray Flash-RT equipment
Ruo TANG ; Xiaozhong HE ; Pengfei ZHU ; Zhuo ZHANG ; Ziping HUANG ; Shuqing LIAO ; Tao WEI ; Liu YANG ; Jinshui SHI
China Medical Equipment 2024;21(1):24-28
The protection effect of flash-radiotherapy(Flash-RT)with super-high dose on normal tissue has obtained wide attention in therapeutic radiology since it was found in 2014 year.The increasing research demand of Flash-RT with super-high dose-rate proposed new challenge for the existing radiotherapy equipment.Based on the demands of FLASH-RT research and clinical application,this review analyzed the proposed new requirement of Flash-RT for equipment,and introduce current scientific facilities with the experimental ability of X-ray FLASH-RT,as well as the situation of the specialized FLASH-RT equipment which were developing.The research of Flash-RT mechanism need the existing equipment with high-energy X-ray source develop toward high power,while the clinical application of Flash-RT demand these transient high-power devices should possess a series of radiotherapy techniques such as multi angle irradiation,conformal radiotherapy and others.Currently,China's X-ray FLASH-RT research is at the forefront of the world,which is expected to achieve the first breakthrough of high-end medical equipment in the X-ray Flash RT field.
10.Analysis of epidemiological and clinical characteristics of 1247 cases of infectious diseases of the central nervous system
Jia-Hua ZHAO ; Yu-Ying CEN ; Xiao-Jiao XU ; Fei YANG ; Xing-Wen ZHANG ; Zhao DONG ; Ruo-Zhuo LIU ; De-Hui HUANG ; Rong-Tai CUI ; Xiang-Qing WANG ; Cheng-Lin TIAN ; Xu-Sheng HUANG ; Sheng-Yuan YU ; Jia-Tang ZHANG
Medical Journal of Chinese People's Liberation Army 2024;49(1):43-49
Objective To summarize the epidemiological and clinical features of infectious diseases of the central nervous system(CNS)by a single-center analysis.Methods A retrospective analysis was conducted on the data of 1247 cases of CNS infectious diseases diagnosed and treated in the First Medical Center of PLA General Hospital from 2001 to 2020.Results The data for this group of CNS infectious diseases by disease type in descending order of number of cases were viruses 743(59.6%),Mycobacterium tuberculosis 249(20.0%),other bacteria 150(12.0%),fungi 68(5.5%),parasites 18(1.4%),Treponema pallidum 18(1.4%)and rickettsia 1(0.1%).The number of cases increased by 177 cases(33.1%)in the latter 10 years compared to the previous 10 years(P<0.05).No significant difference in seasonal distribution pattern of data between disease types(P>0.05).Male to female ratio is 1.87︰1,mostly under 60 years of age.Viruses are more likely to infect students,most often at university/college level and above,farmers are overrepresented among bacteria and Mycobacterium tuberculosis,and more infections of Treponema pallidum in workers.CNS infectious diseases are characterized by fever,headache and signs of meningeal irritation,with the adductor nerve being the more commonly involved cranial nerve.Matagenomic next-generation sequencing improves clinical diagnostic capabilities.The median hospital days for CNS infectious diseases are 18.00(11.00,27.00)and median hospital costs are ¥29,500(¥16,000,¥59,200).The mortality rate from CNS infectious diseases is 1.6%.Conclusions The incidence of CNS infectious diseases is increasing last ten years,with complex clinical presentation,severe symptoms and poor prognosis.Early and accurate diagnosis and standardized clinical treatment can significantly reduce the morbidity and mortality rate and ease the burden of disease.

Result Analysis
Print
Save
E-mail