1.Construction of Organoid-on-a-chip and Its Applications in Biomedical Fields
Rui-Xia LIU ; Jing ZHANG ; Xiao LI ; Yi LIU ; Long HUANG ; Hong-Wei HOU
Progress in Biochemistry and Biophysics 2026;53(2):293-308
Organoid-on-a-chip technology represents a promising interdisciplinary advancement that merges two cutting-edge biomedical platforms: stem cell-derived organoids and microfluidics-based organ-on-a-chip systems. Organoids are self-organizing three-dimensional (3D) cell cultures that mimic the key structural and functional features of in vivo organs. However, traditional organoid culture systems are often static, lacking dynamic environmental cues and suffering from limitations such as batch-to-batch variability, low stability, and low throughput. Organ-on-a-chip platforms, by contrast, utilize microfluidic technologies to simulate the dynamic physiological microenvironment of human tissues and organs, enabling more controlled cell growth and differentiation. By integrating the advantages of organoids and organ-on-a-chip technologies, organoid-on-a-chip systems transcend the limitations of conventional 3D culture models, offering a more physiologically relevant and controllable in vitro platform. In organoid-on-a-chip systems, stem cells or pre-formed organoids are cultured in micro-engineered environments that mimic in vivo conditions, enabling precise control over fluid flow, mechanical forces, and biochemical cues. Specifically, these platforms employ advanced strategies including bio-inspired 3D scaffolds for structural support, precise spatial cell patterning via 3D bioprinting, and integrated biosensors for real-time monitoring of metabolic activities. These synergistic elements recreate complex extracellular matrix signals and ensure high structural fidelity. Based on structural complexity, organoid-on-a-chip systems are classified into single-organoid and multi-organoid types, forming a trajectory from unit biomimicry to systemic simulation. Single-organoid chips focus on highly biomimetic units by integrating vascular, immune, or neural functions. Multi-organoid chips simulate inter-organ crosstalk and systemic homeostasis, advancing complex disease modeling and PK/PD evaluation. This emerging technology has demonstrated broad application potential in multiple fields of biomedicine. Organoid-on-a-chip systems can recapitulate organ developmentin vitro, facilitating research in developmental biology. They mimic organ-specific physiological activities and mechanisms, showing promising applications in regenerative medicine for tissue repair or replacement. In disease modeling, they support the reconstruction of models for neurodegenerative, inflammatory, infectious, metabolic diseases, and cancers. These platforms also enable in vitro drug testing and pharmacokinetic studies (ADME). Patient-derived chips preserve genetic and pathological features, offering potential for precision medicine. Additionally, they reduce species differences in toxicology, providing human-relevant data for environmental, food, cosmetic, and drug safety assessments. Despite progress, organoid-on-a-chip systems face challenges in dynamic simulation, extracellular matrix (ECM) variability, and limited real-time 3D imaging, requiring improved materials and the integration of developmental signals. Current bottlenecks also include the high technical threshold for automation and the lack of standardized validation frameworks for regulatory adoption. Meanwhile, the concept of a “human-on-a-chip” has been proposed to mimic whole-body physiology by integrating multiple organoid modules. This approach enables systemic modeling of drug responses and toxicity, with the potential to reduce animal testing and revolutionize drug development. Future advancements in bio-responsive hydrogels and flexible biosensors will further empower these platforms to bridge the gap between bench-side research and personalized clinical interventions. In conclusion, organoid-on-a-chip technology offers a transformative in vitro model that closely recapitulates the complexity of human tissues and organ systems. It provides an unprecedented platform for advancing biomedical research, clinical translation, and pharmaceutical innovation. Continued development in biomaterials, microengineering, and analytical technologies will be essential to unlocking the full potential of this powerful tool.
2.Construction of Organoid-on-a-chip and Its Applications in Biomedical Fields
Rui-Xia LIU ; Jing ZHANG ; Xiao LI ; Yi LIU ; Long HUANG ; Hong-Wei HOU
Progress in Biochemistry and Biophysics 2026;53(2):293-308
Organoid-on-a-chip technology represents a promising interdisciplinary advancement that merges two cutting-edge biomedical platforms: stem cell-derived organoids and microfluidics-based organ-on-a-chip systems. Organoids are self-organizing three-dimensional (3D) cell cultures that mimic the key structural and functional features of in vivo organs. However, traditional organoid culture systems are often static, lacking dynamic environmental cues and suffering from limitations such as batch-to-batch variability, low stability, and low throughput. Organ-on-a-chip platforms, by contrast, utilize microfluidic technologies to simulate the dynamic physiological microenvironment of human tissues and organs, enabling more controlled cell growth and differentiation. By integrating the advantages of organoids and organ-on-a-chip technologies, organoid-on-a-chip systems transcend the limitations of conventional 3D culture models, offering a more physiologically relevant and controllable in vitro platform. In organoid-on-a-chip systems, stem cells or pre-formed organoids are cultured in micro-engineered environments that mimic in vivo conditions, enabling precise control over fluid flow, mechanical forces, and biochemical cues. Specifically, these platforms employ advanced strategies including bio-inspired 3D scaffolds for structural support, precise spatial cell patterning via 3D bioprinting, and integrated biosensors for real-time monitoring of metabolic activities. These synergistic elements recreate complex extracellular matrix signals and ensure high structural fidelity. Based on structural complexity, organoid-on-a-chip systems are classified into single-organoid and multi-organoid types, forming a trajectory from unit biomimicry to systemic simulation. Single-organoid chips focus on highly biomimetic units by integrating vascular, immune, or neural functions. Multi-organoid chips simulate inter-organ crosstalk and systemic homeostasis, advancing complex disease modeling and PK/PD evaluation. This emerging technology has demonstrated broad application potential in multiple fields of biomedicine. Organoid-on-a-chip systems can recapitulate organ developmentin vitro, facilitating research in developmental biology. They mimic organ-specific physiological activities and mechanisms, showing promising applications in regenerative medicine for tissue repair or replacement. In disease modeling, they support the reconstruction of models for neurodegenerative, inflammatory, infectious, metabolic diseases, and cancers. These platforms also enable in vitro drug testing and pharmacokinetic studies (ADME). Patient-derived chips preserve genetic and pathological features, offering potential for precision medicine. Additionally, they reduce species differences in toxicology, providing human-relevant data for environmental, food, cosmetic, and drug safety assessments. Despite progress, organoid-on-a-chip systems face challenges in dynamic simulation, extracellular matrix (ECM) variability, and limited real-time 3D imaging, requiring improved materials and the integration of developmental signals. Current bottlenecks also include the high technical threshold for automation and the lack of standardized validation frameworks for regulatory adoption. Meanwhile, the concept of a “human-on-a-chip” has been proposed to mimic whole-body physiology by integrating multiple organoid modules. This approach enables systemic modeling of drug responses and toxicity, with the potential to reduce animal testing and revolutionize drug development. Future advancements in bio-responsive hydrogels and flexible biosensors will further empower these platforms to bridge the gap between bench-side research and personalized clinical interventions. In conclusion, organoid-on-a-chip technology offers a transformative in vitro model that closely recapitulates the complexity of human tissues and organ systems. It provides an unprecedented platform for advancing biomedical research, clinical translation, and pharmaceutical innovation. Continued development in biomaterials, microengineering, and analytical technologies will be essential to unlocking the full potential of this powerful tool.
3.Health literacy promotion strategies for the elderly: a review
HOU Rui ; WEI Yingqi ; FANG Kai ; XIE Jin
Journal of Preventive Medicine 2025;37(2):154-157
Abstract
The health literacy level among the elderly in China remains at a low level. The 14th Five-Year Plan for Healthy Aging clearly points out that health literacy promotion projects should be implemented to improve the health literacy level among the elderly. The health literacy promotion strategies for the elderly require individual, social, policy and environmental supports. This article reviewed four types of health literacy promotion strategies for the elderly, including social strategies, lecture-based health education strategies, new media-based health communication strategies and environmental strategies. It also proposed that health education institutions, communities and other parties should work together, take advantage of digital technology and internet, and take various measures simultaneously to improve the health literacy of the elderly.
4.Research and Application of Scalp Surface Laplacian Technique
Rui-Xin LUO ; Si-Ying GUO ; Xin-Yi LI ; Yu-He ZHAO ; Chun-Hou ZHENG ; Min-Peng XU ; Dong MING
Progress in Biochemistry and Biophysics 2025;52(2):425-438
Electroencephalogram (EEG) is a non-invasive, high temporal-resolution technique for monitoring brain activity. However, affected by the volume conduction effect, EEG has a low spatial resolution and is difficult to locate brain neuronal activity precisely. The surface Laplacian (SL) technique obtains the Laplacian EEG (LEEG) by estimating the second-order spatial derivative of the scalp potential. LEEG can reflect the radial current activity under the scalp, with positive values indicating current flow from the brain to the scalp (“source”) and negative values indicating current flow from the scalp to the brain (“sink”). It attenuates signals from volume conduction, effectively improving the spatial resolution of EEG, and is expected to contribute to breakthroughs in neural engineering. This paper provides a systematic overview of the principles and development of SL technology. Currently, there are two implementation paths for SL technology: current source density algorithms (CSD) and concentric ring electrodes (CRE). CSD performs the Laplace transform of the EEG signals acquired by conventional disc electrodes to indirectly estimate the LEEG. It can be mainly classified into local methods, global methods, and realistic Laplacian methods. The global method is the most commonly used approach in CSD, which can achieve more accurate estimation compared with the local method, and it does not require additional imaging equipment compared with the realistic Laplacian method. CRE employs new concentric ring electrodes instead of the traditional disc electrodes, and measures the LEEG directly by differential acquisition of the multi-ring signals. Depending on the structure, it can be divided into bipolar CRE, quasi-bipolar CRE, tripolar CRE, and multi-pole CRE. The tripolar CRE is widely used due to its optimal detection performance. While ensuring the quality of signal acquisition, the complexity of its preamplifier is relatively acceptable. Here, this paper introduces the study of the SL technique in resting rhythms, visual-related potentials, movement-related potentials, and sensorimotor rhythms. These studies demonstrate that SL technology can improve signal quality and enhance signal characteristics, confirming its potential applications in neuroscientific research, disease diagnosis, visual pathway detection, and brain-computer interfaces. CSD is frequently utilized in applications such as neuroscientific research and disease detection, where high-precision estimation of LEEG is required. And CRE tends to be used in brain-computer interfaces, that have stringent requirements for real-time data processing. Finally, this paper summarizes the strengths and weaknesses of SL technology and envisages its future development. SL technology boasts advantages such as reference independence, high spatial resolution, high temporal resolution, enhanced source connectivity analysis, and noise suppression. However, it also has shortcomings that can be further improved. Theoretically, simulation experiments should be conducted to investigate the theoretical characteristics of SL technology. For CSD methods, the algorithm needs to be optimized to improve the precision of LEEG estimation, reduce dependence on the number of channels, and decrease computational complexity and time consumption. For CRE methods, the electrodes need to be designed with appropriate structures and sizes, and the low-noise, high common-mode rejection ratio preamplifier should be developed. We hope that this paper can promote the in-depth research and wide application of SL technology.
5.Effect of different layers of masseter on the bony structure of facial lateral area
Yu-Qi ZHAO ; Jin-Rui JIANG ; Jin-Ran CHEN ; Ze-Chuan WANG ; Hou-En ZHOU ; Wen-Di XU ; Liu-Jun YONG
Acta Anatomica Sinica 2025;56(2):208-213
Objective To observe the morphology of the superficial,middle,and deep layers of the masseter muscle and related bony structures in the lateral facial region of adults through gross anatomy,and to probe into the effects of these muscle layers on the bony structures of the lateral facial region.Methods The bilateral masseter muscles of 12 adult cadavers were exposed,and the superficial,middle,and deep layers were separated and measured for muscle length,tendon length,and muscle belly length.After the masseter muscles were stripped,the total thickness was measured,and the mandible and zygomatic arch were exposed to measure the angle of the mandibular angle,thickness of the zygomatic arch,and width of the zygomatic arch.Observations were made of the masseter tuberosities,and statistical analysis was conducted on their interrelations.Results The zygomatic arch thickness was positively correlated with the length of superficial,middle and deep masseter muscles and the length of superficial and middle masseter belly(r superficial masseter length=0.624,r middle masseter length=0.787,r deep masseter length=0.423,r superficial masseter belly length=0.493,r middle masseter belly length=0.548).The width of the zygomatic arch was positively correlated with the lengths of the superficial and middle muscle layers and the middle muscle belly length(r superficial masseter length=0.527,r middle masseter length=0.521,r middle masseterbelly length=0.437).The angle of the mandibular angle was only negatively correlated with the middle muscle belly length(r=-0.422).The tuberosities of the superficial and middle masseter muscles were not affected by the corresponding muscle layers;However,the tuberosity of the deep masseter was negatively correlated with the length of the deep muscle and the length of the deep tendon(r deep masseter length=-0.543,r deep masseter tendon length=-0.443).Conclusion In the masseter muscle layers of Chinese individuals,the superficial and middle layers have the most significant impact on the bony structures structures of the lateral facial region.These findings are of guiding significance for the remodeling of structures in the lateral facial region.
6.Guideline for diagnosis and treatment of infection after internal fixation of closed lower limb fractures in adults (version 2025)
Bobin MI ; Faqi CAO ; Weixian HU ; Wu ZHOU ; Chenchen YAN ; Hui LI ; Yun SUN ; Yuan XIONG ; Jinmi ZHAO ; Qikai HUA ; Xinbao WU ; Xieyuan JIANG ; Dianying ZHANG ; Zhongguo FU ; Dankai WU ; Guangyao LIU ; Guodong LIU ; Tengbo YU ; Jinhai TAN ; Xi CHEN ; Fengfei LIN ; Zhangyuan LIN ; Dongfa LIAO ; Aiguo WANG ; Shiwu DONG ; Gaoxing LUO ; Zhao XIE ; Dong SUN ; Dehao FU ; Yunfeng CHEN ; Changqing ZHANG ; Kun LIU ; Deye SONG ; Yongjun RUI ; Fei WU ; Ximing LIU ; Junwen WANG ; Meng ZHAO ; Biao CHE ; Bing HU ; Chengjian HE ; Guanglin WANG ; Xiao CHEN ; Guandong DAI ; Shiyuan FANG ; Wenchao SONG ; Ming CHEN ; Guanghua GUO ; Yongqing XU ; Lei YANG ; Wenqian ZHANG ; Kun ZHANG ; Xin TANG ; Hua CHEN ; Weiguo XU ; Shuquan GUO ; Yong LIU ; Xiaodong GUO ; Zhewei YE ; Liming XIONG ; Tian XIA ; Hongbin WU ; Qisheng ZHOU ; Mengfei LIU ; Yiqiang HU ; Yanjiu HAN ; Hang XUE ; Kangkang ZHA ; Wei CHEN ; Zhiyong HOU ; Bin YU ; Jiacan SU ; Peifu TANG ; Baoguo JIANG ; Guohui LIU
Chinese Journal of Trauma 2025;41(5):421-432
Postoperative infection of internal fixation of closed fractures the lower limbs in adults represents a devastating complication, characterized by diagnostic challenges, prolonged treatment duration and high disability rates. Current management of these infections faces multiple challenges, such as difficulties in early accurate diagnosis, and various controversies about the treatment plan, leading to poor overall diagnosis and treatment results. To address these issues, based on evidence-based medicine and principles with emphasis on scientific rigor, clinical applicability and innovation, the Trauma Branch of the Chinese Medical Association, Orthopedic Branch of the Chinese Medical Doctor Association, Orthopedics Branch of the Chinese Medical Association, and Trauma Orthopedics and Polytrauma Group of the Resuscitation and Emergency Committee of the Chinese Medical Doctor Association have collaboratively organized a panel of relevant experts to develop the Guideline for diagnosis and treatment of infection after internal fixation of closed lower limb fractures in adults ( version 2025). The guideline proposed 10 recommendations, aiming to provide a foundation for standardized diagnosis and treatment of postoperative infection in adults with closed lower limb fractures.
7.Clinical guideline for diagnosis and treatment of nonunion of osteoporotic vertebral fractures (version 2025)
Haipeng SI ; Le LI ; Junjie NIU ; Wencan ZHANG ; Fuxin WEI ; Jinqiu YUAN ; Qiang YANG ; Hongli WANG ; Guangchao WANG ; Shihong CHEN ; Yunzhen CHEN ; Xiaoguang CHENG ; Jianwen DONG ; Shiqing FENG ; Rui GU ; Yong HAI ; Tianyong HOU ; Bo HUANG ; Xiaobing JIANG ; Lei ZANG ; Chunhai LI ; Nianhu LI ; Hua LIN ; Hongjian LIU ; Peng LIU ; Xinyu LIU ; Sheng LU ; Shibao LU ; Chunshan LUO ; Lvy CHAOLIANG ; Lvy WEIJIA ; Xuexiao MA ; Wei MEI ; Chunyang MENG ; Cailiang SHEN ; Chunli SONG ; Ruoxian SONG ; Jiacan SU ; Honglin TENG ; Hui SHENG ; Beiyu WANG ; Bingwu WANG ; Liang WANG ; Xiangyang WANG ; Nan WU ; Guohua XU ; Yayi XIA ; Jin XU ; Youjia XU ; Jianzhong XU ; Cao YANG ; Maowei YANG ; Zibin YANG ; Xiaojian YE ; Hailong YU ; Xijie YU ; Hua YUE ; Zhili ZENG ; Xinli ZHAN ; Hui ZHANG ; Peixun ZHANG ; Wei ZHANG ; Zhenlin ZHANG ; Jianguo ZHANG ; Tengyue ZHU ; Qiang LIU ; Huilin YANG
Chinese Journal of Trauma 2025;41(10):932-945
Nonunion of osteoporotic vertebral fractures (OVF), predominantly affecting the elderly, can lead to intractable pain, vertebral collapse, progressive kyphotic deformity, and neurological impairment, significantly compromising patients′ quality of life. There exists considerable debate on diagnosis and management of OVF, encompassing key issues such as clinical diagnosis and staging criteria for nonunion, surgical indications and procedure selection, and postoperative rehabilitation planning. Currently, there lacks standardized clinical guideline and expert consensus on the diagnosis and management of OVF nonunion in China. To address this gap, Minimally Invasive Surgery Group of Chinese Orthopedic Association, Osteoporosis Committee of Chinese Association of Orthopedic Surgeons, Prevention and Rehabilitation Committee for Osteoporosis of Chinese Association of Rehabilitation Medicine and Minimally Invasive Orthopedic Surgery Branch of China Association for Geriatric Care jointly organized domestic experts in spinal surgery, endocrinology, and rehabilitation to formulate the Clinical guideline for the diagnosis and treatment for nonunion of osteoporotic vertebral fractures ( version 2025), based on existing literature and clinical experience and adhering to principles of scientific rigor and practicality. The guideline provided 13 evidence-based recommendations encompassing diagnosis and treatment of OVF nonunion, aiming to standardize its clinical management.
8.Evidence-based guideline for diagnosis and early fixation of severe open tibiofibular fractures (version 2025)
Yongjun RUI ; Yongqing XU ; Qingtang ZHU ; Xin WANG ; Zhao XIE ; Shanlin CHEN ; Jingyi MI ; Xianyou ZHENG ; Juyu TANG ; Xiaoheng DING ; Aixi YU ; Tao SONG ; Jianxi HOU ; Jian QI ; Xinyu FAN ; Jun FEI ; Lin GUO ; Xingwen HAN ; Weixu LI ; Aiguo WANG ; Yun XIE ; Tao XING ; Meng LI ; Baoqing YU ; Yan ZHUANG ; Xiaoqing HE ; Tao SUN ; Pengcheng LI ; Jihui JU ; Hongxiang ZHOU ; Haidong REN ; Guangyue ZHAO ; Gang ZHAO ; Yongwei WU ; Jun LIU ; Yunhong MA ; Yapeng WANG
Chinese Journal of Trauma 2025;41(11):1021-1034
Severe open tibiofibular fractures account for approximately 28.1% of all open fractures. Among them, Gustilo-Anderson type IIIB/C fractures present significant clinical challenges due to associated bone and soft tissue defects, high infection rates, and risk of amputation. Inadequate preoperative assessment may lead to suboptimal emergency surgical planning or intraoperative complications. Historically, external fixation was often preferred, but this approach has been associated with limitations such as restricted joint mobility, delayed bone union, joint stiffness, and disuse osteoporosis, resulting in poor functional recovery. With advancements of debridement techniques, standardization of antibiotic use, and popularization of early soft tissue coverage, early internal fixation has gained broader acceptance. Nevertheless, controversies persist regarding the choice of fixation method, timing of definitive fixation, use of reamed versus unreamed intramedullary nailing, and necessity of fibular fixation. To standardize the diagnosis and early management of severe open tibiofibular fractures, reduce complication rates, and improve functional recovery, the Society of Microsurgery of the Chinese Medical Association organized a panel of domestic experts to develop the Evidence-based guideline for the diagnosis and early fixation of severe open tibiofibular fractures ( version 2025), using evidence-based methodology. The guidelines provided 12 recommendations covering diagnostic and early fixation strategies of severe open tibiofibular fractures, aiming to provide clinicians with scientifically grounded and standardized guidance.
9.Evidence-based clinical practice guideline for bone cement-augmented pedicle screw technique (version 2025)
Sihao HE ; Junchao XING ; Tongwei CHU ; Zhengqi CHANG ; Xigao CHENG ; Fei DAI ; Xiaobing JIANG ; Jie HAO ; Jiang HU ; Jinghui HUANG ; Tianyong HOU ; Fei LUO ; Bo LIAO ; Changqing LI ; Lei LIU ; Guodong LIU ; Peng LIU ; Sheng LU ; Weishi LI ; Yang LIU ; Zhen LIU ; Wei MEI ; Peifu TANG ; Bing WANG ; Bing WANG ; Ce WANG ; Hongli WANG ; Liang WANG ; Shengru WANG ; Xiaobin WANG ; Yang WANG ; Yingfeng WANG ; Zheng WANG ; Jianzhong XU ; Guoyong YIN ; Haiyang YU ; Qiang YANG ; Zhaoming YE ; Bin ZHANG ; Chengmin ZHANG ; Jun ZOU ; Qiang ZHOU ; Min ZHAO ; Rui ZHOU ; Xiaojun ZHANG ; Yongfei ZHAO ; Zhongrong ZHANG ; Zehua ZHANG ; Yingze ZHANG
Chinese Journal of Trauma 2025;41(11):1035-1047
For middle-aged and elderly patients with conditions such as spinal fractures and degenerative spinal diseases, spinal internal fixation is a core surgical procedure for reconstructing spinal stability, heavily relying on the biomechanical stability provided by pedicle screw systems. Whereas, these patients are often complicated by osteoporosis that can significantly compromise the stability of the bone-pedicle screw interface, leading to a marked increase in pedicle screw loosening and surgical failure rates. The bone cement-augmented pedicle screw technique, which involves injecting bone cement into the vertebral body or screw trajectory to optimize the mechanical properties of the bone-pedicle screw composite, has been proven to significantly enhance fixation strength and effectively prevent screw-related failures, thereby reducing the incidence of internal fixation failure in high-risk populations undergoing spinal fusion. However, the widespread clinical application of this technique has faced challenges such as inaccurate clinical decision-making (indication and contraindication selection), non-standardized operative practices, and insufficient awareness of complication prevention, resulting in considerable variability in clinical outcomes and even severe complications. To address this, Prof. Luo Fei from First Affiliated Hospital of Army Medical University initiated the project and the Chinese Association Orthopaedic Surgeons organized relevant experts to develop the Evidence-based clinical practice guideline for bone cement-augmented pedicle screw technique ( version 2025), based on current evidence. The guidelines put forward 8 recommendations regarding the clinical value, scope of application, and operational standards of the technique, aiming to provide evidence-based medical support and technical standardization for clinical decision-making.
10.Pharmacokinetics study of Dayuanyin in normal and febrile rats.
Yu-Jie HOU ; Kang-Ning XIAO ; Jian-Yun BI ; Xin-Jun ZHANG ; Xin-Rui LI ; Yu-Qing WANG ; Ming SU ; Xin-Ru SUN ; Hui ZHANG ; Bo-Yang WANG ; Li-Jie WANG ; Shan-Xin LIU
China Journal of Chinese Materia Medica 2025;50(2):527-533
Based on the pharmacokinetics theory, this study investigated the pharmacokinetic characteristics of albiflorin, paeoniflorin, wogonoside, and wogonin in normal and febrile rats and summarized absorption and elimination rules of Dayuanyin in them to provide reference for further development and clinical application of Dayuanyin. Blood samples were taken from the fundus venous plexus of normal and model rats after intragastric administration of Dayuanyin at different time points. The concentration of each substance in blood was determined by ultra performance liquid chromatography-triple quadrupole mass spectrometry(UPLC-MS/MS) technique at different time points. DAS 2.0, a piece of pharmacokinetics software, was used to calculate the pharmacokinetic parameters of each component. The results show that the 4 components had good linear relationship in their respective ranges, and the results of methodological investigation met the requirements. The pharmacokinetic parameters of C_(max), T_(max), t_(1/2), AUC_(0-t), AUC_(0-∞), and MRT_(0-t) were calculated by the DAS 2.0 non-compartmental model. Compared with those in the normal group, C_(max) and AUC_(0-t) of the 4 components in the model group were significantly increased. There were significant differences in the pharmacokinetic characteristics between the normal and model groups, suggesting that the absorption and elimination of Dayuanyin may be affected by the changes of internal environment of the body in different physiological states.
Animals
;
Rats
;
Drugs, Chinese Herbal/administration & dosage*
;
Male
;
Rats, Sprague-Dawley
;
Fever/metabolism*
;
Tandem Mass Spectrometry
;
Chromatography, High Pressure Liquid
;
Glucosides/pharmacokinetics*
;
Monoterpenes


Result Analysis
Print
Save
E-mail