1.Expert Consensus on the Ethical Requirements for Generative AI-Assisted Academic Writing
You-Quan BU ; Yong-Fu CAO ; Zeng-Yi CHANG ; Hong-Yu CHEN ; Xiao-Wei CHEN ; Yuan-Yuan CHEN ; Zhu-Cheng CHEN ; Rui DENG ; Jie DING ; Zhong-Kai FAN ; Guo-Quan GAO ; Xu GAO ; Lan HU ; Xiao-Qing HU ; Hong-Ti JIA ; Ying KONG ; En-Min LI ; Ling LI ; Yu-Hua LI ; Jun-Rong LIU ; Zhi-Qiang LIU ; Ya-Ping LUO ; Xue-Mei LV ; Yan-Xi PEI ; Xiao-Zhong PENG ; Qi-Qun TANG ; You WAN ; Yong WANG ; Ming-Xu WANG ; Xian WANG ; Guang-Kuan XIE ; Jun XIE ; Xiao-Hua YAN ; Mei YIN ; Zhong-Shan YU ; Chun-Yan ZHOU ; Rui-Fang ZHU
Chinese Journal of Biochemistry and Molecular Biology 2025;41(6):826-832
With the rapid development of generative artificial intelligence(GAI)technologies,their widespread application in academic research and writing is continuously expanding the boundaries of sci-entific inquiry.However,this trend has also raised a series of ethical and regulatory challenges,inclu-ding issues related to authorship,content authenticity,citation accuracy,and accountability.In light of the growing involvement of AI in generating academic content,establishing an open,controllable,and trustworthy ethical governance framework has become a key task for safeguarding research integrity and maintaining trust within the academic community.This expert consensus outlines ethical requirements across key stages of AI-assisted academic writing-including topic selection,data management,citation practices,and authorship attribution.It aims to clarify the boundaries and ethical obligations surrounding AI use in academic writing,ensuring that technological tools enhance efficiency without compromising in-tegrity.The goal is to provide guidance and institutional support for building a responsible and sustainable research ecosystem.
2.The value of coronary angiography-derived fractional flow reserve and coronary angiography-derived index of microcirculatory resistance in coronary artery hemodynamic evaluation
Yang ZHANG ; Quan LI ; Yicong YE ; Xiliang ZHAO ; Liang ZHANG ; Tianyi WANG ; Zhennan LI ; Yaodong DING ; Li LIN ; Yi YE ; Jiayi HAN ; Yong ZENG
Chinese Journal of Cardiology 2025;53(9):1039-1046
Objective:To evaluate the diagnostic value of coronary angiography-derived fractional flow reserve (FFR) and index of microcirculatory resistance (IMR) for identifying coronary functional abnormalities.Methods:This diagnostic study enrolled patients with clinically suspected or diagnosed coronary artery disease who underwent coronary angiography at Beijing Anzhen Hospital, TEDA International Cardiovascular Hospital, and Qilu Hospital of Shandong University between December 2021 and June 2022. All enrolled patients successfully underwent invasive wire-based FFR and IMR measurements during angiography. In a core laboratory, FFR and IMR for the target vessels were measured using artificial intelligence technology based on coronary angiographic images. Spearman correlation analysis was used to evaluate the correlation between angiography-derived FFR and wire-based FFR, and between angiography-derived IMR and wire-based IMR. Coronary hemodynamic abnormality was defined as FFR≤0.80; the diagnostic performance of angiography-derived FFR for identifying this abnormality was evaluated. Microcirculatory dysfunction was defined as IMR≥25; the diagnostic performance of angiography-derived IMR for identifying microcirculatory dysfunction was evaluated.Results:A total of 181 patients, aged (60.6±8.8) years, with 62 (34.3%) females, and 181 target vessels were included in the final analysis. Angiography-derived FFR showed a significant positive correlation with wire-based FFR ( r=0.78, P<0.001). For identifying coronary hemodynamic abnormality, angiography-derived FFR showed an accuracy of 89.0%, sensitivity of 88.8%, specificity of 89.1%, positive predictive value (PPV) of 88.8%, negative predictive value (NPV) of 89.1%, and an area under the receiver operating characteristic curve ( AUC) of 0.88. Angiography-derived IMR showed a significant positive correlation with wire-based IMR ( r=0.93, P<0.001). For identifying microcirculatory dysfunction, angiography-derived IMR demonstrated an accuracy of 89.5%, sensitivity of 86.8%, specificity of 90.2%, PPV of 70.2%, NPV of 96.3%, and an AUC of 0.95. Conclusion:Angiography-derived FFR and IMR exhibit strong correlations with their invasive wire-based counterparts and demonstrate high diagnostic value for assessing coronary hemodynamics and coronary microcirculatory function.
3.Nitrogen-doped Carbon-supported Ruthenium Metal Atom Nanozyme for Colorimetric Determination of Xanthine Oxidase Inhibitors
Quan-Yi LIU ; Qi FANG ; Hui WEI ; Yan DU
Chinese Journal of Analytical Chemistry 2025;53(4):516-524
A colorimetric detection method for xanthine oxidase activity and its inhibitors(XOI)based on nitrogen-doped carbon-supported ruthenium metal atom(Ru/NC)nanozyme was developed.Through a host-guest strategy,Ru/NC nanozyme with excellent peroxidase-like activity was prepared using zeolitic imidazolate framework-8(ZIF-8)as the host molecule and ruthenium acetylacetonate(Ru(acac)3)as the guest molecule.Based on its peroxidase-like catalytic activity,the visual method for detection of hydrogen peroxide(H 2O 2)and analysis of xanthine oxidase(XO)activity were developed.Under optimized experimental conditions,the linear detection range for H 2O 2 was 10-500 μmol/L,with a detection limit of 4.8 μmol/L(3σ);for XO activity analysis,the linear range was 1-7 mU/mL,with a detection limit of 0.69 mU/mL(3σ).Furthermore,an effective method for screening XOI was developed,which had the advantages of low cost,simplicity,and visualization.
4.An RNA-cleaving DNAzyme and G-Quadruplex DNAzyme-Cascade System for Sensing of Small Molecules in Organic Cosolvent
Su-Hui LI ; Shuai-Qi ZHANG ; Yi-Bo ZHANG ; Quan ZHENG ; Tian-Jun CHANG
Chinese Journal of Analytical Chemistry 2025;53(6):914-923
Detection of poor-water-soluble substances typically requires an organic solvent containing solution,and therefore,the biosensors that can operate in such conditions are highly promising for practical applications.However,most existing biosensors have been developed in aqueous solution and it is hard to work effectively in organic solvent systems.In this work,we uncovered that the G-quadruplex(G4)/hemin DNAzyme(G4HD)could be strongly reactivated by NH4 in organic solvents at concentration up to 30%,and the activity was significantly higher than that in aqueous solutions containing K+.Based on this discovery,a biosensing system was developed for small molecule in 40%methanol by coupling G4HD with our previously identified RNA-cleaving DNAzyme(E3).This system comprised an ATP-activated aptazyme that was made of E3 and a G4HD that was activated by the cleavage product of the aptazyme.By using a manmade pipette tip filter to separate the reaction products,the subsequent colorimetric reaction of the G4HD could be triggered.This biosensing system enabled the visualization of target molecules in organic cosolvents without any other instruments.The activable DNAzyme-cascade sensing system had potential in point-of-care detection of poor-water-soluble pollutants,thereby enhancing the practical values of functional nucleic acid-based biosensors in real-world detection conditions.
5.Recommendation for Forensic Identification Guidelines on Insulin Overdoes
Yu-Hao YUAN ; Zhong-Hao YU ; Jia-Xin ZHANG ; Long-Da MA ; Shu-Quan ZHAO ; Ning-Guo LIU ; Rong-Qi WU ; Biao ZHANG ; Xin-Biao LIAO ; Xin CHEN ; Guang-Long HE ; Yi-Wu ZHOU
Journal of Forensic Medicine 2025;41(2):168-175
Insulin is an important protein hormone that participates in multiple metabolic pathways.Biosynthetic insulin has been widely used in the treatment of type 1 and type 2 diabetes.Currently,the number of reported cases of insulin overdose both at home and abroad is gradually increasing,and insulin homicide is no longer a means of"committing murder without leaving a trace".At present,there are no systematic protocols for the identification of insulin overdose in the field of forensic medi-cine in China.This article introduces the causes,toxicological characteristics,forensic examination,labo-ratory testing methods and indicator reference of insulin overdose.Based on the identification practice and research results and referring to relevant studies on insulin overdose at home and abroad,this pa-per aims to provide recommendations and references for the formulation of forensic identification guide-lines for insulin overdose cases.
6.Role of miR-130b-3p/USP47/NLRP3 inflammasome in airway remodeling in asthma
Chang-lin QUAN ; Zhi-guang WANG ; Qiao-yun BAI ; Ning-po DING ; Yi-lan SONG ; Guang-hai YAN
Chinese Pharmacological Bulletin 2025;41(8):1500-1508
Aim To investigate the role of miR-130b-3p in regulating the USP47/NLRP3 inflammasome in airway remodeling associated with asthma and to explore its potential therapeutic value in asthma treat-ment.Methods An OVA-induced asthma mouse mod-el was established,and intervention with miR-130b-3p agomir was performed.Histological staining,quantita-tive real-time PCR,Western blot,immunofluorescence and flow cytometry were used to analyze the effects of miR-130b-3p on the expression of USP47,NLRP3,and related inflammatory factors,as well as the inflamma-some activity.Results miR-130b-3p was significantly downregulated in asthmatic mice,and its intervention significantly inhibited airway epithelial damage,inflam-matory cell infiltration,and collagen deposition.Addi-tionally,miR-130b-3p targeted USP47 and indirectly suppressed NLRP3 expression,leading to reduced in-flammasome activity and alleviated asthma-related in-flammatory responses.Conclusion miR-130b-3p re-duces asthma-related inflammatory responses by down-regulating USP47 expression and indirectly inhibiting NLRP3 inflammasome activity.
7.Discriminating Tumor Deposits From Metastatic Lymph Nodes in Rectal Cancer: A Pilot Study Utilizing Dynamic Contrast-Enhanced MRI
Xue-han WU ; Yu-tao QUE ; Xin-yue YANG ; Zi-qiang WEN ; Yu-ru MA ; Zhi-wen ZHANG ; Quan-meng LIU ; Wen-jie FAN ; Li DING ; Yue-jiao LANG ; Yun-zhu WU ; Jian-peng YUAN ; Shen-ping YU ; Yi-yan LIU ; Yan CHEN
Korean Journal of Radiology 2025;26(5):400-410
Objective:
To evaluate the feasibility of dynamic contrast-enhanced MRI (DCE-MRI) in differentiating tumor deposits (TDs) from metastatic lymph nodes (MLNs) in rectal cancer.
Materials and Methods:
A retrospective analysis was conducted on 70 patients with rectal cancer, including 168 lesions (70 TDs and 98 MLNs confirmed by histopathology), who underwent pretreatment MRI and subsequent surgery between March 2019 and December 2022. The morphological characteristics of TDs and MLNs, along with quantitative parameters derived from DCE-MRI (K trans , kep, and v e) and DWI (ADCmin, ADCmax, and ADCmean), were analyzed and compared between the two groups.Multivariable binary logistic regression and receiver operating characteristic (ROC) curve analyses were performed to assess the diagnostic performance of significant individual quantitative parameters and combined parameters in distinguishing TDs from MLNs.
Results:
All morphological features, including size, shape, border, and signal intensity, as well as all DCE-MRI parameters showed significant differences between TDs and MLNs (all P < 0.05). However, ADC values did not demonstrate significant differences (all P > 0.05). Among the single quantitative parameters, v e had the highest diagnostic accuracy, with an area under the ROC curve (AUC) of 0.772 for distinguishing TDs from MLNs. A multivariable logistic regression model incorporating short axis, border, v e, and ADC mean improved diagnostic performance, achieving an AUC of 0.833 (P = 0.027).
Conclusion
The combination of morphological features, DCE-MRI parameters, and ADC values can effectively aid in the preoperative differentiation of TDs from MLNs in rectal cancer.
8.Discriminating Tumor Deposits From Metastatic Lymph Nodes in Rectal Cancer: A Pilot Study Utilizing Dynamic Contrast-Enhanced MRI
Xue-han WU ; Yu-tao QUE ; Xin-yue YANG ; Zi-qiang WEN ; Yu-ru MA ; Zhi-wen ZHANG ; Quan-meng LIU ; Wen-jie FAN ; Li DING ; Yue-jiao LANG ; Yun-zhu WU ; Jian-peng YUAN ; Shen-ping YU ; Yi-yan LIU ; Yan CHEN
Korean Journal of Radiology 2025;26(5):400-410
Objective:
To evaluate the feasibility of dynamic contrast-enhanced MRI (DCE-MRI) in differentiating tumor deposits (TDs) from metastatic lymph nodes (MLNs) in rectal cancer.
Materials and Methods:
A retrospective analysis was conducted on 70 patients with rectal cancer, including 168 lesions (70 TDs and 98 MLNs confirmed by histopathology), who underwent pretreatment MRI and subsequent surgery between March 2019 and December 2022. The morphological characteristics of TDs and MLNs, along with quantitative parameters derived from DCE-MRI (K trans , kep, and v e) and DWI (ADCmin, ADCmax, and ADCmean), were analyzed and compared between the two groups.Multivariable binary logistic regression and receiver operating characteristic (ROC) curve analyses were performed to assess the diagnostic performance of significant individual quantitative parameters and combined parameters in distinguishing TDs from MLNs.
Results:
All morphological features, including size, shape, border, and signal intensity, as well as all DCE-MRI parameters showed significant differences between TDs and MLNs (all P < 0.05). However, ADC values did not demonstrate significant differences (all P > 0.05). Among the single quantitative parameters, v e had the highest diagnostic accuracy, with an area under the ROC curve (AUC) of 0.772 for distinguishing TDs from MLNs. A multivariable logistic regression model incorporating short axis, border, v e, and ADC mean improved diagnostic performance, achieving an AUC of 0.833 (P = 0.027).
Conclusion
The combination of morphological features, DCE-MRI parameters, and ADC values can effectively aid in the preoperative differentiation of TDs from MLNs in rectal cancer.
9.Comparison of pedicled lateral thoracic artery perforator flap and mammoplasty in oncoplastic breast-conserving surgery for early-stage breast cancer
Yixian LI ; Mingquan HUANG ; Haiyan WANG ; Bin WU ; Huaiquan ZUO ; Yi QUAN ; Guangrui PAN
Chinese Journal of General Surgery 2025;34(5):953-962
Background and Aims:Oncoplastic breast-conserving surgery(OBCS)integrates oncologic and plastic surgical techniques and includes two primary approaches:volume displacement and volume replacement.The pedicled lateral thoracic artery perforator(LTAP)flap is a commonly used technique for volume replacement.Although recent studies in China have confirmed its safety in OBCS,its patient-reported outcomes have not been systematically evaluated,and comparative data with volume displacement techniques remain lacking.Therefore,this study was performed to compare the clinical outcomes and patient satisfaction of LTAP flap versus mammoplasty(volume displacement)in OBCS,to inform surgical decision-making.Methods:A retrospective case-control study was conducted,including 106 patients with unilateral stage 0-Ⅲ breast cancer who underwent OBCS at the Affiliated Hospital of Southwest Medical University from January 2023 to June 2024.Patients were divided into the LTAP flap group(27 cases)and the mammoplasty group(79 cases)based on the surgical technique.Intraoperative variables,cosmetic outcomes,postoperative complications,and Breast-Q scores before and after surgery were compared between the two groups.Results:There were no significant differences between the two groups in clinicopathological characteristics or preoperative Breast-Q scores(all P>0.05).The LTAP group had longer operative times,larger excised tissue volumes,and greater postoperative drainage volumes(all P<0.001).Postoperative cosmetic outcomes were significantly better in the LTAP group,with a higher rate of excellent-to-good cosmetic results(88.9%vs.57.3%)and higher Breast-Q scores in breast satisfaction,psychosocial well-being,and physical well-being(all P<0.05).There were no significant differences in complication rates or local recurrence between the two groups(all P>0.05).Conclusion:In OBCS,the LTAP flap demonstrates comparable safety to mammoplasty while achieving superior cosmetic outcomes and patient satisfaction.It is particularly suitable for patients with small breast volumes requiring large tissue excision and holds promise for broader clinical application.
10.Maintenance of MAQUET ROTAFLOW ECMO system:Four case reports
Zeng-qiang FANG ; Bin-quan WANG ; Li-gang LOU ; Jing-yi FENG
Chinese Medical Equipment Journal 2025;46(5):116-120
The composition and working principle of MAQUET ROTAFLOW ECMO system were introduced.Four cases of common failures of ROTAFLOW ECMO systems were analyzed in terms of the cause and elimination method.The methods for the maintenance and quality control of ECMO system were put forward.References were provided for engineering technicians to treat similar faults.[Chinese Medical Equipment Journal,2025,46(5):116-120]

Result Analysis
Print
Save
E-mail