1.Polypeptide-based Nanocarriers for Oral Targeted Delivery of CAR Genes to Pancreatic Cancer
Feng XIN ; Jian REN ; Zhao-Zhen LI ; Quan FANG ; Rui-Jing LIANG ; Lan-Lan LIU ; Lin-Tao CAI
Progress in Biochemistry and Biophysics 2026;53(2):431-441
ObjectivePancreatic ductal adenocarcinoma (PDAC) exhibits a limited response to current treatments due to its dense fibrotic stroma and highly immunosuppressive tumor microenvironment. In recent years, advancements in cellular immunotherapy, particularly chimeric antigen receptor macrophage (CAR-M) therapy, have offered new hope for pancreatic cancer treatment. Although CAR-M therapy demonstrates dual potential in directly killing tumor cells and remodeling the immune microenvironment, it still faces challenges such as complex in vitro preparation processes and low in vivo targeting and delivery efficiency. Therefore, developing strategies for efficient and targeted in vivo delivery of CAR genes has become crucial for overcoming current therapeutic limitations. This study aims to develop an orally administrable nano-gene delivery system for the targeted delivery of CAR genes to pancreatic tumor sites. MethodsCore nano-gene particles (PNP/pCAR) were constructed by loading plasmid DNA encoding CAR (pCAR) with cationic polypeptides (PNP). Subsequently, PNP/pCAR was surface-modified with β-glucan to prepare the targeted nanoparticles (βGlus-PNP/pCAR). The loading efficiency of PNP for pCAR was quantitatively assessed by gel retardation assay. The particle size, Zeta potential, morphology, and storage stability of PNP/pCAR were characterized using a Malvern particle size analyzer and transmission electron microscopy. At the cellular level, RAW 264.7 macrophages were selected. The cytotoxicity of PNP/pCAR was evaluated using the CCK-8 assay. The cellular uptake efficiency and lysosomal escape ability of the nanoparticles were assessed via flow cytometry and confocal microscopy. Transfection efficiency was quantitatively evaluated by detecting the expression of the reporter gene GFP using flow cytometry. At the in vivo level, an orthotopic pancreatic cancer mouse model was established. Cy7-labeled βGlus-PNP/pCAR nanoparticles were administered orally, and the fluorescence distribution in mice was dynamically monitored at 1, 2, 4, 8, and 16 h post-administration using a small animal in vivo imaging system. Forty-eight hours after oral gavage, the mice were euthanized, and pancreatic tumor tissues were collected for further analysis of intratumoral fluorescence signals using the imaging system. Additionally, βGlus-PNP/pCAR-GFP nanoparticles loaded with the reporter gene (GFP) were administered orally. Forty-eight hours post-administration, pancreatic tumor tissues were harvested to prepare frozen sections, and GFP expression was observed and analyzed under a fluorescence microscope. ResultsThe PNP carrier exhibited a high loading capacity for pCAR. The successfully prepared PNP/pCAR nanoparticles were regular spheres with a hydrodynamic diameter of approximately (120±10) nm and a Zeta potential of about +(6±1) mV. They maintained good structural stability after incubation in PBS buffer for 7 d. Cell experiments demonstrated that PNP/pCAR exhibited no significant cytotoxicity in RAW 264.7 cells while being efficiently internalized and effectively escaping lysosomal degradation. The transfection positive rate of PNP/pCAR-GFP in RAW 264.7 cells reached (25±3)%, surpassing that of Lipofectamine 2000-loaded pCAR-GFP (Lipo/pCAR-GFP), which was (20±1)%.In vivo experiments revealed that, compared to unmodified PNP/pCAR, βGlus-PNP/pCAR exhibited strongerin situ pancreatic tumor targeting ability after oral administration. Furthermore, oral administration of βGlus-PNP/pCAR-GFP resulted in significant GFP protein expression detectable within pancreatic tumor tissues. ConclusionThis study successfully constructed and validated an orally administrable, pancreatic cancer-targeting polypeptide-based nano-gene delivery system. It provides an important technological foundation in delivery systems and experimental basis for the subsequent development of in situ CAR-M-based therapeutic strategies for pancreatic cancer.
2.Polypeptide-based Nanocarriers for Oral Targeted Delivery of CAR Genes to Pancreatic Cancer
Feng XIN ; Jian REN ; Zhao-Zhen LI ; Quan FANG ; Rui-Jing LIANG ; Lan-Lan LIU ; Lin-Tao CAI
Progress in Biochemistry and Biophysics 2026;53(2):431-441
ObjectivePancreatic ductal adenocarcinoma (PDAC) exhibits a limited response to current treatments due to its dense fibrotic stroma and highly immunosuppressive tumor microenvironment. In recent years, advancements in cellular immunotherapy, particularly chimeric antigen receptor macrophage (CAR-M) therapy, have offered new hope for pancreatic cancer treatment. Although CAR-M therapy demonstrates dual potential in directly killing tumor cells and remodeling the immune microenvironment, it still faces challenges such as complex in vitro preparation processes and low in vivo targeting and delivery efficiency. Therefore, developing strategies for efficient and targeted in vivo delivery of CAR genes has become crucial for overcoming current therapeutic limitations. This study aims to develop an orally administrable nano-gene delivery system for the targeted delivery of CAR genes to pancreatic tumor sites. MethodsCore nano-gene particles (PNP/pCAR) were constructed by loading plasmid DNA encoding CAR (pCAR) with cationic polypeptides (PNP). Subsequently, PNP/pCAR was surface-modified with β-glucan to prepare the targeted nanoparticles (βGlus-PNP/pCAR). The loading efficiency of PNP for pCAR was quantitatively assessed by gel retardation assay. The particle size, Zeta potential, morphology, and storage stability of PNP/pCAR were characterized using a Malvern particle size analyzer and transmission electron microscopy. At the cellular level, RAW 264.7 macrophages were selected. The cytotoxicity of PNP/pCAR was evaluated using the CCK-8 assay. The cellular uptake efficiency and lysosomal escape ability of the nanoparticles were assessed via flow cytometry and confocal microscopy. Transfection efficiency was quantitatively evaluated by detecting the expression of the reporter gene GFP using flow cytometry. At the in vivo level, an orthotopic pancreatic cancer mouse model was established. Cy7-labeled βGlus-PNP/pCAR nanoparticles were administered orally, and the fluorescence distribution in mice was dynamically monitored at 1, 2, 4, 8, and 16 h post-administration using a small animal in vivo imaging system. Forty-eight hours after oral gavage, the mice were euthanized, and pancreatic tumor tissues were collected for further analysis of intratumoral fluorescence signals using the imaging system. Additionally, βGlus-PNP/pCAR-GFP nanoparticles loaded with the reporter gene (GFP) were administered orally. Forty-eight hours post-administration, pancreatic tumor tissues were harvested to prepare frozen sections, and GFP expression was observed and analyzed under a fluorescence microscope. ResultsThe PNP carrier exhibited a high loading capacity for pCAR. The successfully prepared PNP/pCAR nanoparticles were regular spheres with a hydrodynamic diameter of approximately (120±10) nm and a Zeta potential of about +(6±1) mV. They maintained good structural stability after incubation in PBS buffer for 7 d. Cell experiments demonstrated that PNP/pCAR exhibited no significant cytotoxicity in RAW 264.7 cells while being efficiently internalized and effectively escaping lysosomal degradation. The transfection positive rate of PNP/pCAR-GFP in RAW 264.7 cells reached (25±3)%, surpassing that of Lipofectamine 2000-loaded pCAR-GFP (Lipo/pCAR-GFP), which was (20±1)%.In vivo experiments revealed that, compared to unmodified PNP/pCAR, βGlus-PNP/pCAR exhibited strongerin situ pancreatic tumor targeting ability after oral administration. Furthermore, oral administration of βGlus-PNP/pCAR-GFP resulted in significant GFP protein expression detectable within pancreatic tumor tissues. ConclusionThis study successfully constructed and validated an orally administrable, pancreatic cancer-targeting polypeptide-based nano-gene delivery system. It provides an important technological foundation in delivery systems and experimental basis for the subsequent development of in situ CAR-M-based therapeutic strategies for pancreatic cancer.
3.Mosquito monitoring and influence of meteorological factors on mosquito density around Beijing Capital International Airport, 2016-2022
Ran FENG ; Tie-zheng MA ; Si-jie ZHU ; Bo TIAN ; Fei QUAN ; Zhi-lin WU ; Xiao-tao LIU ; Fu-yuan ZHANG ; Song-jian ZHANG
Acta Parasitologica et Medica Entomologica Sinica 2026;33(1):40-48
Objective To understand mosquito density, species composition, and seasonal variations around the Beijing Capital International Airport(BCIA)and provide scientific evidence for mosquito-borne disease prevention and control. Methods Meteorological data were collected from 2016 to 2022, and mosquito density was monitored at seven surveillance sites around the BCIA from May to October each year using CO2-baited mosquito traps to analyze the relationship between mosquito density and meteorological factors. Results In total,68 518 female mosquitoes were captured, with a mosquito density of 10.20 per light · hour. The dominant species was Culex pipiens pallens(73.90%), followed by Aedes albopictus(9.71%)and Ae. vexans(9.29%);the mosquito density was highest in 2016(14.8 per light·hour)and lowest in 2022(4.46 per light·hour). Significant statistical differences were observed in mosquito density among different species(F=18.118, P<0.05). The density of Cx. pipiens pallens and other mosquito species showed a mutually exclusive trend; the peak of mosquito density varied based on years and habitats, with significant statistical differences in mosquito density among different habitats(F=8.504, P<0.05). The highest mosquito density was observed near the Wenyu River(21.50 per light·hour), whereas the lowest was recorded at the BCIA construction site(2.44 per light· hour). The monthly average temperature(r=0.595), monthly average highest temperature(r=0.575), and monthly average lowest temperature(r=0.624)showed moderate positive correlations, whereas the monthly average air pressure(r=-0.484)showed a moderate negative correlation. The monthly average minimum temperature was included in the regression model(F=25.575, P<0.000), and the equation Y=1.029X4-8.181 was used. The monthly average air pressure 2 months prior(b=-2.418, β=-1.619, P<0.05)and the monthly average relative humidity(b=-0.739, β=-1.201, P<0.05)significantly negatively predicted the mosquito density. Notably, the regression equation used was y=2526.170+(-2.418)X9+(-0.739)X13. The exposure-response analysis revealed that the density of mosquitoes was not linearly related to the average monthly air pressure, rainfall, and duration of sunshine. Conclusions The dominant mosquito species around the BCIA was Cx. pipiens pallens, Ae. albopictus, and Ae. vexans. During the control of Cx. pipiens pallens, the impact on other mosquito species must also be considered. Environmental management, breeding sites, and scientific use of pesticides should be prioritized based on the activity periods of mosquitoes. Further studies on mosquitoes and meteorological factors should be conducted to provide references and novel avenues for mosquito control.
4.Discriminating Tumor Deposits From Metastatic Lymph Nodes in Rectal Cancer: A Pilot Study Utilizing Dynamic Contrast-Enhanced MRI
Xue-han WU ; Yu-tao QUE ; Xin-yue YANG ; Zi-qiang WEN ; Yu-ru MA ; Zhi-wen ZHANG ; Quan-meng LIU ; Wen-jie FAN ; Li DING ; Yue-jiao LANG ; Yun-zhu WU ; Jian-peng YUAN ; Shen-ping YU ; Yi-yan LIU ; Yan CHEN
Korean Journal of Radiology 2025;26(5):400-410
Objective:
To evaluate the feasibility of dynamic contrast-enhanced MRI (DCE-MRI) in differentiating tumor deposits (TDs) from metastatic lymph nodes (MLNs) in rectal cancer.
Materials and Methods:
A retrospective analysis was conducted on 70 patients with rectal cancer, including 168 lesions (70 TDs and 98 MLNs confirmed by histopathology), who underwent pretreatment MRI and subsequent surgery between March 2019 and December 2022. The morphological characteristics of TDs and MLNs, along with quantitative parameters derived from DCE-MRI (K trans , kep, and v e) and DWI (ADCmin, ADCmax, and ADCmean), were analyzed and compared between the two groups.Multivariable binary logistic regression and receiver operating characteristic (ROC) curve analyses were performed to assess the diagnostic performance of significant individual quantitative parameters and combined parameters in distinguishing TDs from MLNs.
Results:
All morphological features, including size, shape, border, and signal intensity, as well as all DCE-MRI parameters showed significant differences between TDs and MLNs (all P < 0.05). However, ADC values did not demonstrate significant differences (all P > 0.05). Among the single quantitative parameters, v e had the highest diagnostic accuracy, with an area under the ROC curve (AUC) of 0.772 for distinguishing TDs from MLNs. A multivariable logistic regression model incorporating short axis, border, v e, and ADC mean improved diagnostic performance, achieving an AUC of 0.833 (P = 0.027).
Conclusion
The combination of morphological features, DCE-MRI parameters, and ADC values can effectively aid in the preoperative differentiation of TDs from MLNs in rectal cancer.
5.Discriminating Tumor Deposits From Metastatic Lymph Nodes in Rectal Cancer: A Pilot Study Utilizing Dynamic Contrast-Enhanced MRI
Xue-han WU ; Yu-tao QUE ; Xin-yue YANG ; Zi-qiang WEN ; Yu-ru MA ; Zhi-wen ZHANG ; Quan-meng LIU ; Wen-jie FAN ; Li DING ; Yue-jiao LANG ; Yun-zhu WU ; Jian-peng YUAN ; Shen-ping YU ; Yi-yan LIU ; Yan CHEN
Korean Journal of Radiology 2025;26(5):400-410
Objective:
To evaluate the feasibility of dynamic contrast-enhanced MRI (DCE-MRI) in differentiating tumor deposits (TDs) from metastatic lymph nodes (MLNs) in rectal cancer.
Materials and Methods:
A retrospective analysis was conducted on 70 patients with rectal cancer, including 168 lesions (70 TDs and 98 MLNs confirmed by histopathology), who underwent pretreatment MRI and subsequent surgery between March 2019 and December 2022. The morphological characteristics of TDs and MLNs, along with quantitative parameters derived from DCE-MRI (K trans , kep, and v e) and DWI (ADCmin, ADCmax, and ADCmean), were analyzed and compared between the two groups.Multivariable binary logistic regression and receiver operating characteristic (ROC) curve analyses were performed to assess the diagnostic performance of significant individual quantitative parameters and combined parameters in distinguishing TDs from MLNs.
Results:
All morphological features, including size, shape, border, and signal intensity, as well as all DCE-MRI parameters showed significant differences between TDs and MLNs (all P < 0.05). However, ADC values did not demonstrate significant differences (all P > 0.05). Among the single quantitative parameters, v e had the highest diagnostic accuracy, with an area under the ROC curve (AUC) of 0.772 for distinguishing TDs from MLNs. A multivariable logistic regression model incorporating short axis, border, v e, and ADC mean improved diagnostic performance, achieving an AUC of 0.833 (P = 0.027).
Conclusion
The combination of morphological features, DCE-MRI parameters, and ADC values can effectively aid in the preoperative differentiation of TDs from MLNs in rectal cancer.
6.Discriminating Tumor Deposits From Metastatic Lymph Nodes in Rectal Cancer: A Pilot Study Utilizing Dynamic Contrast-Enhanced MRI
Xue-han WU ; Yu-tao QUE ; Xin-yue YANG ; Zi-qiang WEN ; Yu-ru MA ; Zhi-wen ZHANG ; Quan-meng LIU ; Wen-jie FAN ; Li DING ; Yue-jiao LANG ; Yun-zhu WU ; Jian-peng YUAN ; Shen-ping YU ; Yi-yan LIU ; Yan CHEN
Korean Journal of Radiology 2025;26(5):400-410
Objective:
To evaluate the feasibility of dynamic contrast-enhanced MRI (DCE-MRI) in differentiating tumor deposits (TDs) from metastatic lymph nodes (MLNs) in rectal cancer.
Materials and Methods:
A retrospective analysis was conducted on 70 patients with rectal cancer, including 168 lesions (70 TDs and 98 MLNs confirmed by histopathology), who underwent pretreatment MRI and subsequent surgery between March 2019 and December 2022. The morphological characteristics of TDs and MLNs, along with quantitative parameters derived from DCE-MRI (K trans , kep, and v e) and DWI (ADCmin, ADCmax, and ADCmean), were analyzed and compared between the two groups.Multivariable binary logistic regression and receiver operating characteristic (ROC) curve analyses were performed to assess the diagnostic performance of significant individual quantitative parameters and combined parameters in distinguishing TDs from MLNs.
Results:
All morphological features, including size, shape, border, and signal intensity, as well as all DCE-MRI parameters showed significant differences between TDs and MLNs (all P < 0.05). However, ADC values did not demonstrate significant differences (all P > 0.05). Among the single quantitative parameters, v e had the highest diagnostic accuracy, with an area under the ROC curve (AUC) of 0.772 for distinguishing TDs from MLNs. A multivariable logistic regression model incorporating short axis, border, v e, and ADC mean improved diagnostic performance, achieving an AUC of 0.833 (P = 0.027).
Conclusion
The combination of morphological features, DCE-MRI parameters, and ADC values can effectively aid in the preoperative differentiation of TDs from MLNs in rectal cancer.
7.Establishment and evaluation of a lipopolysaccharide-induced acute respiratory distress syndrome model in minipigs
Chuang-Ye WANG ; Ran WANG ; Jian ZHANG ; Ling-Xiao QIU ; Bin QING ; Heng YOU ; Jin-Cheng LIU ; Bin WANG ; Nan-Bo WANG ; Jia-Yu LI ; Xing LIU ; Shuang WANG ; Jin HU ; Jian WEN ; Quan LI ; Xiao-Ou HUANG ; Kun ZHAO ; Shuang-Lin LIU ; Gang LIU ; Mei-Ju WANG ; Qing XIANG ; Hong-Mei WU ; Xiao-Rong SUN ; Tao GU ; Dong ZHANG ; Qi LI ; Zhi XU
Medical Journal of Chinese People's Liberation Army 2025;50(9):1154-1161
Objective To establish a stable,reliable,and clinically relevant porcine model of endotoxin-induced acute respiratory distress syndrome(ARDS).Methods Ten 8-month-old male Bama minipigs were deeply sedated,followed by invasive mechanical ventilation and electrocardiographic monitoring.Lipopolysaccharide(LPS)was intravenously pumped at 600 μg/(kg·h)for 3 hours,then maintained at 15 μg/(kg·h)thereafter.Dynamic monitoring was performed at five time points after LPS injection(LPS 0,1,3,5,and 8 h),including arterial blood gas analysis and chest computed tomography(CT)scans.Pathological examination of lung tissues obtained via bronchoscopic biopsy(HE staining and transmission electron microscopy)was conducted.These indicators were comprehensively used to evaluate the success of the animal model.Results At 5 hours after LPS administration,8 minipigs developed symptoms such as skin cyanosis,elevated body temperature,and respiratory distress.The oxygenation index decreased to<300 mmHg.Chest CT scans showed diffuse pulmonary infiltrates.Histopathology revealed alveolar edema and hyaline membrane formation.Transmission electron microscopy demonstrated disruption of pulmonary blood-air barrier,depletion of lamellar bodies in type Ⅱ pneumocytes,inflammatory cell infiltration,and exudation of plasma proteins and fibrin.Compared with LPS 0 h,at LPS 8 h,the oxygenation index and arterial blood pH were significantly decreased(P<0.001),while blood lactic acid and serum potassium were significantly increased(P<0.05);serum calcium and base excess were significantly decreased(P<0.05),and the lung injury score based on HE-stained lung sections was significantly increased(P<0.01).Conclusion The porcine ARDS model established by continuous LPS injection can dynamically simulate the pathophysiological characteristics and typical pathological manifestations of clinical septic ARDS,making it an effective tool to study the pathogenesis,prevention,and treatment strategies of septic ARDS.
8.Yin-yang in modern traditional Chinese medicine: From mechanisms to digital innovation
Guanhu Yang ; Tong Pu ; Fengxing Tao ; Xiaomin Quan ; Kai Cheng
Journal of Traditional Chinese Medical Sciences 2025;2025(4):492-498
The theory of yin-yang is a foundational concept in traditional Chinese medicine (TCM) and has been refined through millennia of clinical practice and theoretical development. This theory remains central to syndrome differentiation and therapeutic decision-making. With rapid advances in modern biomedicine and information sciences, this review synthesizes recent interdisciplinary progress linking yin-yang concepts to cellular metabolism, redox balance, gene regulation, and immunomodulation. We outline how pathological states historically described as “yin deficiency” or “yang hyperactivity” correspond to alterations in cellular energy conversion, molecular signaling networks, and systemic homeostasis, and we critically evaluate current evidence for mechanistic pathways. Notwithstanding promising correlations, major gaps persist in mechanistic clarity and the establishment of quantitative metrics, limiting the rigorous integration of yin-yang theory into evidence-based frameworks. To address these gaps, we propose a research roadmap that leverages modern biotechnology, mathematical modeling, and artificial intelligence for quantitative multiscale analysis. By integrating molecular, cellular, and systemic datasets, this approach can clarify the biological connotations of yin-yang balance for physiology, disease mechanisms, and clinical outcome assessment.
9.Discriminating Tumor Deposits From Metastatic Lymph Nodes in Rectal Cancer: A Pilot Study Utilizing Dynamic Contrast-Enhanced MRI
Xue-han WU ; Yu-tao QUE ; Xin-yue YANG ; Zi-qiang WEN ; Yu-ru MA ; Zhi-wen ZHANG ; Quan-meng LIU ; Wen-jie FAN ; Li DING ; Yue-jiao LANG ; Yun-zhu WU ; Jian-peng YUAN ; Shen-ping YU ; Yi-yan LIU ; Yan CHEN
Korean Journal of Radiology 2025;26(5):400-410
Objective:
To evaluate the feasibility of dynamic contrast-enhanced MRI (DCE-MRI) in differentiating tumor deposits (TDs) from metastatic lymph nodes (MLNs) in rectal cancer.
Materials and Methods:
A retrospective analysis was conducted on 70 patients with rectal cancer, including 168 lesions (70 TDs and 98 MLNs confirmed by histopathology), who underwent pretreatment MRI and subsequent surgery between March 2019 and December 2022. The morphological characteristics of TDs and MLNs, along with quantitative parameters derived from DCE-MRI (K trans , kep, and v e) and DWI (ADCmin, ADCmax, and ADCmean), were analyzed and compared between the two groups.Multivariable binary logistic regression and receiver operating characteristic (ROC) curve analyses were performed to assess the diagnostic performance of significant individual quantitative parameters and combined parameters in distinguishing TDs from MLNs.
Results:
All morphological features, including size, shape, border, and signal intensity, as well as all DCE-MRI parameters showed significant differences between TDs and MLNs (all P < 0.05). However, ADC values did not demonstrate significant differences (all P > 0.05). Among the single quantitative parameters, v e had the highest diagnostic accuracy, with an area under the ROC curve (AUC) of 0.772 for distinguishing TDs from MLNs. A multivariable logistic regression model incorporating short axis, border, v e, and ADC mean improved diagnostic performance, achieving an AUC of 0.833 (P = 0.027).
Conclusion
The combination of morphological features, DCE-MRI parameters, and ADC values can effectively aid in the preoperative differentiation of TDs from MLNs in rectal cancer.
10.Discriminating Tumor Deposits From Metastatic Lymph Nodes in Rectal Cancer: A Pilot Study Utilizing Dynamic Contrast-Enhanced MRI
Xue-han WU ; Yu-tao QUE ; Xin-yue YANG ; Zi-qiang WEN ; Yu-ru MA ; Zhi-wen ZHANG ; Quan-meng LIU ; Wen-jie FAN ; Li DING ; Yue-jiao LANG ; Yun-zhu WU ; Jian-peng YUAN ; Shen-ping YU ; Yi-yan LIU ; Yan CHEN
Korean Journal of Radiology 2025;26(5):400-410
Objective:
To evaluate the feasibility of dynamic contrast-enhanced MRI (DCE-MRI) in differentiating tumor deposits (TDs) from metastatic lymph nodes (MLNs) in rectal cancer.
Materials and Methods:
A retrospective analysis was conducted on 70 patients with rectal cancer, including 168 lesions (70 TDs and 98 MLNs confirmed by histopathology), who underwent pretreatment MRI and subsequent surgery between March 2019 and December 2022. The morphological characteristics of TDs and MLNs, along with quantitative parameters derived from DCE-MRI (K trans , kep, and v e) and DWI (ADCmin, ADCmax, and ADCmean), were analyzed and compared between the two groups.Multivariable binary logistic regression and receiver operating characteristic (ROC) curve analyses were performed to assess the diagnostic performance of significant individual quantitative parameters and combined parameters in distinguishing TDs from MLNs.
Results:
All morphological features, including size, shape, border, and signal intensity, as well as all DCE-MRI parameters showed significant differences between TDs and MLNs (all P < 0.05). However, ADC values did not demonstrate significant differences (all P > 0.05). Among the single quantitative parameters, v e had the highest diagnostic accuracy, with an area under the ROC curve (AUC) of 0.772 for distinguishing TDs from MLNs. A multivariable logistic regression model incorporating short axis, border, v e, and ADC mean improved diagnostic performance, achieving an AUC of 0.833 (P = 0.027).
Conclusion
The combination of morphological features, DCE-MRI parameters, and ADC values can effectively aid in the preoperative differentiation of TDs from MLNs in rectal cancer.


Result Analysis
Print
Save
E-mail