1.Predicting intraoperative blood transfusion risk in hip fracture patients using explainable machine learning models
Fengting LU ; Xiaoming LI ; Dekui LI ; Xianyuan XIE ; Jiazhong WANG ; Qing YU ; Gan HUANG ; Jun SHEN
Chinese Journal of Blood Transfusion 2026;39(2):196-202
Objective: To investigate the factors influencing intraoperative blood transfusion in patients with hip fractures and to develop a machine learning (ML) model for predicting this risk. Methods: A total of 424 patients with hip fractures who underwent surgical treatment between November 2022 and March 2025 in our hospital were selected. Key feature variables of intraoperative blood transfusion risk were identified using the Boruta algorithm. Four different ML algorithms—support vector machine (SVM), linear discriminant analysis (LDA), mixed discriminant analysis (MDA), and extreme gradient boosting (XGBoost)—were used to develop predictive models for intraoperative blood transfusion risk. The predictive performance of the four ML models were evaluated using accuracy, precision, receiver operating characteristic (ROC) curves, precision-recall curves (PRC), precision-recall gain curves (PRGC), and F1 scores. Shapley additive interpretation (SHAP) was used to interpret the final model. Results: Among the 424 patients, 77(18.2%) received intraoperative blood transfusion. The Boruta algorithm identified albumin (ALB), activated partial thromboplastin time (APTT), types of anesthesia, types of fracture, and hemoglobin (Hb) as key feature variables for predicting intraoperative blood transfusion risk. In model evaluation, the SVM model outperforms the other three models across multiple metrics, including the area under the receiver operating characteristic curve (AUC), recall, recall gain, accuracy, precision, F1 score, and the area under the precision-recall curve (PRC-AUC). The SVM model, interpreted and visualized based on SHAP values, effectively predicted intraoperative blood transfusion risk in patients with hip fracture. A visual online application was developed based on the SVM model (https://pbo-nomogram.shinyapps.io/blood/). Conclusion: Preoperative low ALB and Hb levels, prolonged APTT, general anesthesia, and intertrochanteric fractures are risk factors for intraoperative blood transfusion in hip fracture patients. The risk prediction model for intraoperative blood transfusion constructed based on the SVM algorithm has optimal performance, which provides new ideas and methods for the clinical early identification of hip fracture patients with high transfusion risk and the implementation of targeted interventions.
2.Neuroelectromagnetic Activities Across Temporal Scales
Zhuo-Qun SHEN ; Xiao-Fei XU ; Yan-Qing WANG ; Jing-Xin LI ; Lan TIAN ; Wei GUO ; Jing-Jing XU
Progress in Biochemistry and Biophysics 2026;53(6):1541-1560
Although global brain science research has progressed rapidly in recent decades, several fundamental questions in neuroscience remain unresolved. In particular, the physical mechanism underlying neural signal transmission remains controversial, and the carriers responsible for neural information storage and retrieval have not yet been fully clarified. These unresolved issues motivate us to re-examine the processes of neural information generation, transmission, integration, storage, and retrieval from multiple perspectives. A key observation is that neural electromagnetic activities are closely associated with time. Their duration, temporal structure, and dynamic evolution play crucial roles in neural information processing. In this work, we analyze neural electromagnetic activities from the perspective of temporal scales (referred to here as the “time course”). By reviewing and integrating findings from previous studies, we examine the characteristic time requirements and dynamic features of neural processes occurring at different stages of information processing. These stages include neural signal generation, signal transmission along axons, synaptic integration, synaptic plasticity, and memory formation and retrieval. Based on this temporal analysis, we outline a framework describing neural electromagnetic activities across a wide range of time scales, spanning from microseconds to minutes, hours, or even longer periods associated with long-term memory, which suggests that neural information processing involves multiple physical processes operating at different time levels. Rapid electromagnetic events may occur on microsecond scales, whereas electrophysiological phenomena such as action potentials typically last on the order of milliseconds. Longer time scales are associated with synaptic plasticity and memory-related processes. From this perspective, we propose that the physical carrier of neural information may be transient electromagnetic pulses with durations on the microsecond scale. In this framework, action potentials can be interpreted as the macroscopic electrophysiological manifestation of underlying electromagnetic processes triggered by ionic currents across neuronal membranes. Rather than being the fundamental neural signal itself, the action potential may represent a measurable membrane-level response associated with the successful activation of these electromagnetic events. Moreover, we discuss a possible mechanism for long-term memory storage. Considering the apparent temporal contradiction between the millisecond-scale excitation of neurons and the long-term persistence of memories, we believe that long-term memory information may be stored within neural network topologies formed by electrical synapse coupling. Such structures, referred to as electrically coupled memory networks (ECMNs), may enable neurons within the same network to respond rapidly and synchronously to stimuli, thereby facilitating efficient memory retrieval. Overall, this study emphasizes the importance of considering the temporal organization of neural electromagnetic activities when interpreting neural signaling mechanisms. It may provide new insights into the physical nature of neural information carriers and the mechanisms of memory storage and retrieval. Furthermore, highlighting the potential role of electromagnetic interactions in neural activity may contribute to the development of new theoretical frameworks and experimental approaches in neuroscience. Such perspectives may also offer valuable references for future research on neural coding, brain function mechanisms, and neuromodulation technologies.
3.Expert consensus on visualized tele-round and quality control management based on the improvement of clinical practice ability
Wanhong YIN ; Xiaoting WANG ; Ran ZHOU ; Dawei LIU ; Yan KANG ; Yaoqing TANG ; Xiaochun MA ; Jianguo LI ; Zhenjie HU ; Haitao ZHANG ; Wei HE ; Lixia LIU ; Wenjin CHEN ; Ran ZHU ; Jun WU ; Hongmin ZHANG ; Lina ZHANG ; Wenzhao CHAI ; Shihong ZHU ; Wangbin XU ; Rongqing SUN ; Xiangyou YU ; Tianjiao SONG ; Ying ZHU ; Hong REN ; Ai SHANMU ; Qing ZHANG ; Wei FANG ; Xiuling SHANG ; Liwen LYU ; Shuhan CAI ; Xin DING ; Heng ZHANG ; Guang FENG ; Lipeng ZHANG ; Bo HU ; Dong ZHANG ; Weidong WU ; Feng SHEN ; Xiaojun YANG ; Zhenguo ZENG ; Qibing HUANG ; Xueying ZENG ; Tongjuan ZOU ; Milin PENG ; Yulong YAO ; Mingming CHEN ; Hui LIAN ; Jingmei WANG ; Yong LI ; Feng QU ; Gang YE ; Rongli YANG ; Xiukai CHEN ; Suwei LI ; Juxiang WANG ; Yangong CHAO
Chinese Journal of Internal Medicine 2025;64(2):101-109
Turning to critical illness is a common stage of various diseases and injuries before death. Patients usually have complex health conditions, while the treatment process involves a wide range of content, along with high requirements for doctor′s professionalism and multi-specialty teamwork, as well as a great demand for time-sensitive treatments. However, this is not matched with critical care professionals and the current state of medical care in China. Telemedicine, which shortens the distance of medical professionals and the gap of disease diagnosis and treatments in various regions through electronic information, can effectively solve the current problem. Therefore, there is an urgent need to develop a standardized, high-quality visualization telemedicine round system .Therefore, experts have been organized to search domestic and foreign literature on telemedicine round for critically ill patients and to form this consensus based on clinical experiences so as to further improve the level of critical care treatments in regions.
4.Surveillance for pneumonia of unknown etiology: current status, challenges, and implementation ways
Boer QI ; Qing WANG ; Ju WANG ; Tingting LI ; Yanlin CAO ; Rui SHEN ; Li QI ; Jiang LONG ; Weizhong YANG ; Luzhao FENG
Chinese Journal of Epidemiology 2025;46(5):914-920
The prevention and control of emerging and reemerging infectious diseases are crucial for national biosecurity, and surveillance and reporting of pneumonia of unknown etiology are main ways for the early detection of these diseases and mitigation of their severity. This paper summaries the surveillance methods for pneumonia of unknown etiology and emerging and reemerging infectious diseases globally, indicating that such surveillance is mainly conducted based on hospital. Western countries primarily combine active and passive surveillance while utilizing artificial intelligence technology to rapidly identify cases. China mainly use passive surveillance based on the surveillance system for pneumonia of unknown etiology, with the function of early warning in the identification of emerging infectious diseases, such as avian influenza. However, with the improvement in the surveillance system operation, the overlap with other surveillance disease systems, such as influenza, has occurred, and the improvements in case definition and operational protocol are needed. It is recommended to improve the specificity of the case definition, strenthen training in hospital staff, inclduing clinical workers and office workers, and formulate incentive mechanisms. It is necessary to emphasize the responsibility of clinicians as the main force for the detection and reporting of pneumonia of unknown etiology and emerging infectious diseases, improve the appilication of artifical intelligent technique and conduct multi-source surveillance, such as third-party testing.
5.Diagnostic value of a combined clinical-radiomics model based on MRI for the assessment of renal fibrosis in chronic kidney disease
Chaogang WEI ; Ying ZENG ; Qing MA ; Zhicheng JIN ; Yilin XU ; Ye ZHU ; Xiaojing LI ; Junkang SHEN ; Zhen JIANG
Chinese Journal of Radiology 2025;59(10):1163-1169
Objective:To explore the diagnostic value of a clinical-radiomics model based on the T 1 mapping and apparent diffusion coefficient (ADC)-based radiomics, and the clinical indicator for renal fibrosis (RF) caused by chronic kidney disease (CKD). Methods:This cross-sectional study prospectively and consecutively enrolled 122 patients with CKD at the Second Affiliated Hospital of Soochow University from September 2021 to December 2023 who were randomly allocated to a training set ( n=85) or a validation set ( n=37) in an approximate 7∶3 ratio using simple random sampling. Patients underwent T 1 mapping and diffusion-weighted imaging scans. Renal biopsy was performed within 3 days after the MRI scans. Patients were categorized into three groups based on the degree of RF: no RF ( n=25), mild RF ( n=55), and moderate to severe RF ( n=42). To differentiate the presence of RF (no RF vs. any RF) and the severity of RF (mild RF vs. moderate to severe RF), univariate and multivariate logistic regression were used to optimize the independent clinical predictor, which constituted the clinical model. Radiomics features were extracted from regions of interest delineated within the renal parenchyma of the right kidney on T 1 mapping and ADC maps. Features were selected using least absolute shrinkage and selection operator regression to build the radiomics model. A clinical-radiomics model was subsequently constructed by integrating the independent clinical predictors with the selected radiomics features. Model diagnostic performance was evaluated using the area under the receiver operating characteristic curve (AUC). Calibration curve was plotted to assess model calibration, and decision curve analysis was performed to evaluate clinical net benefit. Results:Univariate logistic regression analysis revealed that estimated glomerular filtration rate (eGFR), serum creatinine, and blood urea nitrogen exhibited statistically significant differences ( P0.05) in distinguishing both the presence and severity of RF. Multivariate analysis identified eGFR as an independent clinical predictor for both the presence of RF ( OR=0.939, 95% CI 0.898-0.982, P=0.006) and RF severity ( OR=0.956, 95% CI 0.917-0.997, P=0.037). From the MRI images, 7 radiomics features were selected to build the radiomics model for distinguishing the presence of RF, and 8 features were selected for the model assessing RF severity. These radiomics models were then combined with eGFR to construct the clinical-radiomics models. The clinical-radiomics models demonstrated the highest diagnostic performance, with an AUC of 0.935 (95% CI 0.859-0.977) for RF presence and 0.967 (95% CI 0.891-0.995) for RF severity in the training set, and 0.914 (95% CI 0.774-0.981) and 0.908 (95% CI 0.748-0.981) in the validation set. Calibration curves and decision curve analysis confirmed that the clinical-radiomics models exhibited excellent calibration and provided the highest clinical net benefit for assessing RF in CKD patients. Conclusion:The clinical-radiomics model integrating T 1 mapping and ADC-based radiomics and eGFR can effectively improve the diagnostic performance for RF in CKD patients.
6.Design and application of auto-review program for data records in radiotherapy
Yaling HONG ; Shijie LI ; Zhengxin GAO ; Yunfeng WU ; Qiaoying HU ; Shen FU ; Qing GONG ; Wei XIE
China Medical Equipment 2025;22(2):170-174
Objective:To develop and design a during-treatment records auto-review program to comply the quality assurance(QA)requirement of radiotherapy chart auditing,and thereby improve the review efficiency and accuracy.Methods:Based on the items the guideline required,the Aria Oncology Information System database backup files was analyzed by Java,Vue,and etc.languages and the corresponding review logic was formulated.A total of 530 treatment records generated at Shanghai Concord Cancer Center from January to March 2024(10 weeks)were auto-reviewed and compared with the manual results for evaluating the accuracy and efficiency of the program.Results:The auto-review program was running smoothly.Overall with the above data,the sensitivity,specificity,accuracy and the error-miss rate were 73.4%,14.3%,87.7%and 12.3%respectively.For sub-set items,the source-skin distance(SSD)error detecting rate was 100%,the wrong session reporting was 100%correlated with the plans switching and the wrong fraction reporting was 100%related to plan revision.For the other items,auto and manual reviews gave out the same accuracy.Conclusion:The none-error results from the program are all true,so the manual rechecking could limit to those auto-review error records,which can reduce the workload by 73.4%,therefore improve the effectiveness and accuracy of the radiotherapy data review.
7.Preparation of MXene-Carbon Nanotube Microspheres and Its Application in Electrochemical Detection of Nitroaromatic Compounds
Yu LIU ; Hou-Shen LI ; Qing-Shuang YAO ; Pei-Yao LI ; Yi-Min SUN
Chinese Journal of Analytical Chemistry 2025;53(3):407-417
The MXene/MF microspheres were prepared by coating MXene nanosheets on melamine formaldehyde(MF)resin microspheres.Co(NO3)2 was adsorbed on the surface of the microspheres by impregnation,and then calcined at high temperature in an argon atmosphere.MF pyrolysis generated reducing gases such as CO and NH3,reducing Co2+to elemental Co,which was then used as a catalyst for in situ growth of carbon nanotube(CNT)through chemical vapor deposition(CVD),forming MXene-Co-CNT microspheres(MXene-Co-CNT MS).During this process,the pyrolysis of MF microspheres had dual effects.On one hand,the template was sacrificed to produce an internal hollow structure,and on the other hand,the generated gas worked as carbon source to generate CNT,forming an external sea urchin-like structure.Both of them promoted the formation of a novel structure,which combined the advantages of large specific surface area and good conductivity,thus possessing excellent electrocatalytic activity.The MXene-Co-CNT MS was modified on glassy carbon electrode(GCE)and further used in highly sensitive detection of nitroaromatic compounds(NACs).The detection limits of MXene-Co-CNT MS/GCE for 2,4,6-trinitrotoluene(TNT),1,3,5-nitrobenzamide(TNB),2,4-dinitrotoluene(DNT),1,3-dinitrobenzene(DNB),1-Cl-2,4-dinitrotoluene(Cl-DNB),and 4-nitrophenol(4-NP)were 26.84,31.60,35.03,54.14,43.86 and 28.67 nmol/L,respectively.It also had excellent anti-interference ability,and was used to detect NACs in environmental water samples accurately.
8.Combination of CT/MRI LI-RADS With Second-Line Contrast-Enhanced Ultrasound Using Sulfur Hexafluoride or Perfluorobutane for Diagnosing Hepatocellular Carcinoma in High-Risk Patients
Yu LI ; Sheng LI ; Qing LI ; Kai LI ; Jing HAN ; Siyue MAO ; Xiaohong XU ; Zhongzhen SU ; Yanling ZUO ; Shousong XIE ; Hong WEN ; Xuebin ZOU ; Jingxian SHEN ; Lingling LI ; Jianhua ZHOU
Korean Journal of Radiology 2025;26(4):346-359
Objective:
The CT/MRI Liver Imaging Reporting and Data System (LI-RADS) demonstrates high specificity with relatively limited sensitivity for diagnosing hepatocellular carcinoma (HCC) in high-risk patients. This study aimed to explore the possibility of improving sensitivity by combining CT/MRI LI-RADS v2018 with second-line contrast-enhanced ultrasound (CEUS) LI-RADS v2017 using sulfur hexafluoride (SHF) or perfluorobutane (PFB).
Materials and Methods:
This retrospective analysis of prospectively collected multicenter data included high-risk patients with treatment-naive hepatic observations. The reference standard was pathological confirmation or a composite reference standard (only for benign lesions). Each participant underwent concurrent CT/MRI, SHF-enhanced US, and PFB-enhanced US examinations. The diagnostic performances for HCC of CT/MRI LI-RADS alone and three combination strategies (combining CT/ MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or a modified algorithm incorporating the Kupffer-phase findings for PFB [modified PFB]) were evaluated. For the three combination strategies, apart from the CT/MRI LR-5 criteria, HCC was diagnosed if CT/MRI LR-3 or LR-4 observations met the LR-5 criteria using LI-RADS SHF, LI-RADS PFB, or modified PFB.
Results:
In total, 281 participants (237 males; mean age, 55 ± 11 years) with 306 observations (227 HCCs, 40 non-HCC malignancies, and 39 benign lesions) were included. Using LI-RADS SHF, LI-RADS PFB, and modified PFB, 20, 23, and 31 CT/MRI LR-3/4 observations, respectively, were reclassified as LR-5, and all were pathologically confirmed as HCCs. Compared to CT/MRI LI-RADS alone (74%, 95% confidence interval [CI]: 68%–79%), the three combination strategies combining CT/MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or modified PFB increased sensitivity (83% [95% CI: 77%–87%], 84% [95% CI: 79%–89%], 88% [95% CI: 83%–92%], respectively; all P < 0.001), while maintaining the specificity at 92% (95% CI: 84%–97%).
Conclusion
The combination of CT/MRI LI-RADS with second-line CEUS using SHF or PFB improved the sensitivity of HCC diagnosis without compromising specificity.
9.Berg Balance Scale score is a valuable predictor of all-cause mortality among acute decompensated heart failure patients.
Yu-Xuan FAN ; Jing-Jing CHENG ; Zhi-Qing FAN ; Jing-Jin LIU ; Wen-Juan XIU ; Meng-Yi ZHAN ; Lin LUO ; Guang-He LI ; Le-Min WANG ; Yu-Qin SHEN
Journal of Geriatric Cardiology 2025;22(6):555-562
OBJECTIVE:
To investigate possible associations between physical function assessment scales, such as Short Physical Performance Battery (SPPB) and Berg Balance Scale (BBS), with all-cause mortality in acute decompensated heart failure (ADHF) patients.
METHODS:
A total of 108 ADHF patients were analyzed from October 2020 to October 2022, and followed up to May 2023. The association between baseline clinical characteristics and all-cause mortality was analyzed by univariate Cox regression analysis, while for SPPB and BBS, univariate Cox regression analysis was followed by receiver operating characteristic curves, in which the area under the curve represented their predictive accuracy for all-cause mortality. Incremental predictive values for both physical function assessments were measured by calculating net reclassification index and integrated discrimination improvement scores. Optimal cut-off value for BBS was then identified using restricted cubic spline plots, and survival differences below and above that cut-off were compared using Kaplan-Meier survival curves and the log-rank test. The clinical utility of BBS was measured using decision curve analysis.
RESULTS:
For baseline characteristics, age, female, blood urea nitrogen, as well as statins, angiotensin-converting enzyme inhibitors, angiotensin II receptor blockers, or angiotensin receptor-neprilysin inhibitors, were predictive for all-cause mortality for ADHF patients. With respect to SPPB and BBS, higher scores were associated with lower all-cause mortality rates for both assessments; similar area under the curves were measured for both (0.774 for SPPB and 0.776 for BBS). Furthermore, BBS ≤ 36.5 was associated with significantly higher mortality, which was still applicable even adjusting for confounding factors; BBS was also found to have great clinical utility under decision curve analysis.
CONCLUSIONS
BBS or SPPB could be used as tools to assess physical function in ageing ADHF patients, as well as prognosticate on all-cause mortality. Moreover, prioritizing the improvement of balance capabilities of ADHF patients in cardiac rehabilitation regimens could aid in lowering mortality risk.
10.Gallstones, cholecystectomy, and cancer risk: an observational and Mendelian randomization study.
Yuanyue ZHU ; Linhui SHEN ; Yanan HUO ; Qin WAN ; Yingfen QIN ; Ruying HU ; Lixin SHI ; Qing SU ; Xuefeng YU ; Li YAN ; Guijun QIN ; Xulei TANG ; Gang CHEN ; Yu XU ; Tiange WANG ; Zhiyun ZHAO ; Zhengnan GAO ; Guixia WANG ; Feixia SHEN ; Xuejiang GU ; Zuojie LUO ; Li CHEN ; Qiang LI ; Zhen YE ; Yinfei ZHANG ; Chao LIU ; Youmin WANG ; Shengli WU ; Tao YANG ; Huacong DENG ; Lulu CHEN ; Tianshu ZENG ; Jiajun ZHAO ; Yiming MU ; Weiqing WANG ; Guang NING ; Jieli LU ; Min XU ; Yufang BI ; Weiguo HU
Frontiers of Medicine 2025;19(1):79-89
This study aimed to comprehensively examine the association of gallstones, cholecystectomy, and cancer risk. Multivariable logistic regressions were performed to estimate the observational associations of gallstones and cholecystectomy with cancer risk, using data from a nationwide cohort involving 239 799 participants. General and gender-specific two-sample Mendelian randomization (MR) analysis was further conducted to assess the causalities of the observed associations. Observationally, a history of gallstones without cholecystectomy was associated with a high risk of stomach cancer (adjusted odds ratio (aOR)=2.54, 95% confidence interval (CI) 1.50-4.28), liver and bile duct cancer (aOR=2.46, 95% CI 1.17-5.16), kidney cancer (aOR=2.04, 95% CI 1.05-3.94), and bladder cancer (aOR=2.23, 95% CI 1.01-5.13) in the general population, as well as cervical cancer (aOR=1.69, 95% CI 1.12-2.56) in women. Moreover, cholecystectomy was associated with high odds of stomach cancer (aOR=2.41, 95% CI 1.29-4.49), colorectal cancer (aOR=1.83, 95% CI 1.18-2.85), and cancer of liver and bile duct (aOR=2.58, 95% CI 1.11-6.02). MR analysis only supported the causal effect of gallstones on stomach, liver and bile duct, kidney, and bladder cancer. This study added evidence to the causal effect of gallstones on stomach, liver and bile duct, kidney, and bladder cancer, highlighting the importance of cancer screening in individuals with gallstones.
Humans
;
Mendelian Randomization Analysis
;
Gallstones/complications*
;
Female
;
Male
;
Cholecystectomy/statistics & numerical data*
;
Middle Aged
;
Risk Factors
;
Aged
;
Adult
;
Neoplasms/etiology*
;
Stomach Neoplasms/epidemiology*

Result Analysis
Print
Save
E-mail