1.Advances in detection techniques for congenital blood group chimerism
Shuo ZHANG ; Hongyan YANG ; Yuhan GAO ; Ranran QIN ; Xinrui WANG ; Ke ZHANG ; Yifan LI ; Ruiqin HOU
Chinese Journal of Blood Transfusion 2026;39(3):402-407
Congenital blood group chimerism refers to the coexistence of two or more distinct blood types within an individual, resulting from the presence of hematopoietic cell populations with different genotypes. Consequently, red blood cells in such individuals may express different blood group antigens. Based on the timing and mechanism of formation, blood group chimerism can be classified as either congenital or acquired. Although congenital blood group chimerism is rare and involves complex mechanisms, it holds significant implications in transfusion medicine, transplantation, and obstetrics. This article reviews the formation mechanisms, detection methods, and clinical significance of congenital blood group chimerism in transfusion medicine. Particular emphasis is placed on the principles, advantages, and limitations of various detection techniques. Furthermore, the potential applications of these technologies in clinical diagnosis are discussed, providing a technical foundation for the development of precise transfusion strategies.
2.Intravenous delivery of STING agonists using acid-sensitive polycationic polymer-modified lipid nanoparticles for enhanced tumor immunotherapy.
Ying HE ; Ke ZHENG ; Xifeng QIN ; Siyu WANG ; Xuejing LI ; Huiwen LIU ; Mingyang LIU ; Ruizhe XU ; Shaojun PENG ; Zhiqing PANG
Acta Pharmaceutica Sinica B 2025;15(3):1211-1229
Although cancer immunotherapy has made great strides in the clinic, it is still hindered by the tumor immunosuppressive microenvironment (TIME). The stimulator of interferon genes (STING) pathway which can modulate TIME effectively has emerged as a promising therapeutic recently. However, the delivery of most STING agonists, specifically cyclic dinucleotides (CDNs), is performed intratumorally due to their insufficient pharmacological properties, such as weak permeability across cell membranes and vulnerability to nuclease degradation. To expand the clinical applicability of CDNs, a novel pH-sensitive polycationic polymer-modified lipid nanoparticle (LNP-B) system was developed for intravenous delivery of CDNs. LNP-B significantly extended the circulation of CDNs and enhanced the accumulation of CDNs within the tumor, spleen, and tumor-draining lymph nodes compared with free CDNs thereby triggering the STING pathway of dendritic cells and repolarizing pro-tumor macrophages. These events subsequently gave rise to potent anti-tumor immune reactions and substantial inhibition of tumors in CT26 colon cancer-bearing mouse models. In addition, due to the acid-sensitive property of the polycationic polymer, the delivery system of LNP-B was more biocompatible and safer compared with lipid nanoparticles formulated with an indissociable cationic DOTAP (LNP-D). These findings suggest that LNP-B has great potential in the intravenous delivery of CDNs for tumor immunotherapy.
3.Intranodal injection of neoantigen-bearing engineered Lactococcus lactis triggers epitope spreading and systemic tumor regressions.
Junmeng ZHU ; Yi SUN ; Xiaoping QIAN ; Lin LI ; Fangcen LIU ; Xiaonan WANG ; Yaohua KE ; Jie SHAO ; Lijing ZHU ; Lifeng WANG ; Qin LIU ; Baorui LIU
Acta Pharmaceutica Sinica B 2025;15(4):2217-2236
Probiotics are natural systems bridging synthetic biology, physical biotechnology, and immunology, initiating innate and adaptive anti-tumor immune activity. We previously constructed an all-in-one engineered food-grade probiotic Lactococcus lactis (FOLactis) which could boost the crosstalk among different immune cells such as dendritic cells (DCs), natural killer cells, and T cells. Herein, considering the limited clinical efficacy of naked personalized neoantigen peptide vaccines, we decorate FOLactis with tumor antigens by employing a Plug-and-Display system comprising membrane-inserted peptides. Intranodal injection of FOLactis coated with neoantigen peptides (Ag-FOLactis) induces robust DCs presentation and neoantigen-specific cellular immunity. Notably, Ag-FOLactis not only triggers a 45-fold rise in the quantity of locally reactive neoantigen-specific T cells but also induces epitope spreading in both subcutaneous and metastatic tumor-bearing models, leading to potent inhibition of tumor growth. These findings imply that Ag-FOLactis represents a powerful platform to rapidly and easily display antigens, facilitating the development of a bio-activated platform for personalized therapy.
4.Assessment of genetic associations between antidepressant drug targets and various stroke subtypes: A Mendelian randomization approach.
Luyang ZHANG ; Yunhui CHU ; Man CHEN ; Yue TANG ; Xiaowei PANG ; Luoqi ZHOU ; Sheng YANG ; Minghao DONG ; Jun XIAO ; Ke SHANG ; Gang DENG ; Wei WANG ; Chuan QIN ; Daishi TIAN
Chinese Medical Journal 2025;138(4):487-489
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Anatomical Importance Between Neural Structure and Bony Landmark in Neuroventral Decompression for Posterior Endoscopic Cervical Discectomy
Xin WANG ; Tao HU ; Chaofan QIN ; Bo LEI ; Mingxin CHEN ; Ke MA ; Qingyan LONG ; Qingshuai YU ; Si CHENG ; Zhengjian YAN
Neurospine 2025;22(1):286-296
Objective:
This study aims to investigate the anatomical relationship among the nerve roots, intervertebral space, pedicles, and intradural rootlets of the cervical spine for improving operative outcomes and exploring neuroventral decompression approach in posterior endoscopic cervical discectomy (PECD).
Methods:
Cervical computed tomography myelography imaging data from January 2021 to May 2023 were collected, and the RadiAnt DICOM Viewer Software was employed to conduct multiplane reconstruction. The following parameters were recorded: width of nerve root (WN), nerve root-superior pedicle distance (NSPD), nerve root-inferior pedicle distance (NIPD), and the relationship between the intervertebral space and the nerve root (shoulder, anterior, and axillary). Additionally, the descending angles between the spinal cord and the ventral (VRA) and dorsal (DRA) rootlets were measured.
Results:
The WN showed a gradual increase from C4 to C7, with measurements notably larger in men compared to women. The NSPD decreased gradually from the C2–3 to the C5–6 levels. However, the NIPD showed an opposite level-related change, notably larger than the NSPD at the C4–5, C5–6, and C7–T1 levels. Furthermore, significant differences in NIPD were observed between different age groups and genders. The incidence of the anterior type exhibited a gradual decrease from the C2–3 to the C5–6 levels. Conversely, the axillary type exhibited an opposite level-related change. Additionally, the VRA and DRA decreased as the level descended, with measurements significantly larger in females.
Conclusion
A prediction of the positional relationship between the intervertebral space and the nerve root is essential for the direct neuroventral decompression in PECD to avoid damaging the neural structures. The axillary route of the nerve root offers a safer and more effective pathway for performing direct neuroventral decompression compared to the shoulder approach.
7.Predicting Postoperative Progression of Ossification of the Posterior Longitudinal Ligament in the Cervical Spine Using Interpretable Radiomics Models
Siyuan QIN ; Ruomu QU ; Ke LIU ; Ruixin YAN ; Weili ZHAO ; Jun XU ; Enlong ZHANG ; Feifei ZHOU ; Ning LANG
Neurospine 2025;22(1):144-156
Objective:
This study investigates the potential of radiomics to predict postoperative progression of ossification of the posterior longitudinal ligament (OPLL) after posterior cervical spine surgery.
Methods:
This retrospective study included 473 patients diagnosed with OPLL at Peking University Third Hospital between October 2006 and September 2022. Patients underwent posterior spinal surgery and had at least 2 computed tomography (CT) examinations spaced at least 1 year apart. OPLL progression was defined as an annual growth rate exceeding 7.5%. Radiomic features were extracted from preoperative CT images of the OPLL lesions, followed by feature selection using correlation coefficient analysis and least absolute shrinkage and selection operator, and dimensionality reduction using principal component analysis. Univariable analysis identified significant clinical variables for constructing the clinical model. Logistic regression models, including the Rad-score model, clinical model, and combined model, were developed to predict OPLL progression.
Results:
Of the 473 patients, 191 (40.4%) experienced OPLL progression. On the testing set, the combined model, which incorporated the Rad-score and clinical variables (area under the receiver operating characteristic curve [AUC] = 0.751), outperformed both the radiomics-only model (AUC = 0.693) and the clinical model (AUC = 0.620). Calibration curves demonstrated good agreement between predicted probabilities and observed outcomes, and decision curve analysis confirmed the clinical utility of the combined model. SHAP (SHapley Additive exPlanations) analysis indicated that the Rad-score and age were key contributors to the model’s predictions, enhancing clinical interpretability.
Conclusion
Radiomics, combined with clinical variables, provides a valuable predictive tool for assessing the risk of postoperative progression in cervical OPLL, supporting more personalized treatment strategies. Prospective, multicenter validation is needed to confirm the utility of the model in broader clinical settings.
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
9.Analysis of human parvovirus B19 nucleic acid detection in blood products in China
Yue WANG ; Xiaobei ZHENG ; Qin GONG ; Ying ZHAO ; Yuanxiu LUO ; Dandan YANG ; Linlin ZHANG ; Zheng JIANG ; Gan PENG ; Jin ZHANG ; Bingbing KE
Chinese Journal of Blood Transfusion 2025;38(7):950-957
Objective: To analyze the nucleic acid load of human parvovirus B19 in major commercially available blood products in China, including human albumin, human intravenous immunoglobulin, human rabies immunoglobulin and various coagulation factor products, aiming to provide evidence for improving blood product manufacturing processes and quality control of source plasma. Methods: A total of 98 batches of coagulation factor products were tested for human parvovirus B19 nucleic acid using real-time fluorescent quantitative PCR, including 42 batches of human prothrombin complex, 35 batches of human coagulation factor Ⅷ, and 21 batches of human fibrinogen. Additionally, 6 batches of human albumin, 6 batches of human intravenous immunoglobulin, and 38 batches of human rabies immunoglobulin were tested for human parvovirus B19 nucleic acid. Results: Human parvovirus B19 nucleic acid were undetectable in human albumin, human intravenous immunoglobulin and human rabies immunoglobulin. Among the 98 batches of coagulation factor products tested for human parvovirus B19 nucleic acid, B19 nucleic acid reactivity rate was 69.0% (29/42) for human prothrombin complex batches, but nucleic acid concentration were all significantly lower than 10
IU/mL. The reactivity rate of B19 nucleic acid in 35 batches of human coagulation factor Ⅷ was 48.6% (17/35), with nucleic acid concentration all below 10
IU/mL. The reactivity rate of B19 nucleic acid in 21 batches of human fibrinogen was 61.9% (13/21), with nucleic acid concentration all below 10
IU/mL. Conclusion: No human parvovirus B19 has been detected in human albumin, human intravenous immunoglobulin, or human rabies immunoglobulin. Human parvovirus B19 nucleic acid may exist in commercially available coagulation factor products, highlighting the need for enhanced screening of human parvovirus B19 nucleic acid in these products. It is also recommended that B19 viral nucleic acid testing be conducted on source plasma, particularly for coagulation factor products.
10.Analysis of human parvovirus B19 nucleic acid detection in blood products in China
Yue WANG ; Xiaobei ZHENG ; Qin GONG ; Ying ZHAO ; Yuanxiu LUO ; Dandan YANG ; Linlin ZHANG ; Zheng JIANG ; Gan PENG ; Jin ZHANG ; Bingbing KE
Chinese Journal of Blood Transfusion 2025;38(7):950-957
Objective: To analyze the nucleic acid load of human parvovirus B19 in major commercially available blood products in China, including human albumin, human intravenous immunoglobulin, human rabies immunoglobulin and various coagulation factor products, aiming to provide evidence for improving blood product manufacturing processes and quality control of source plasma. Methods: A total of 98 batches of coagulation factor products were tested for human parvovirus B19 nucleic acid using real-time fluorescent quantitative PCR, including 42 batches of human prothrombin complex, 35 batches of human coagulation factor Ⅷ, and 21 batches of human fibrinogen. Additionally, 6 batches of human albumin, 6 batches of human intravenous immunoglobulin, and 38 batches of human rabies immunoglobulin were tested for human parvovirus B19 nucleic acid. Results: Human parvovirus B19 nucleic acid were undetectable in human albumin, human intravenous immunoglobulin and human rabies immunoglobulin. Among the 98 batches of coagulation factor products tested for human parvovirus B19 nucleic acid, B19 nucleic acid reactivity rate was 69.0% (29/42) for human prothrombin complex batches, but nucleic acid concentration were all significantly lower than 10
IU/mL. The reactivity rate of B19 nucleic acid in 35 batches of human coagulation factor Ⅷ was 48.6% (17/35), with nucleic acid concentration all below 10
IU/mL. The reactivity rate of B19 nucleic acid in 21 batches of human fibrinogen was 61.9% (13/21), with nucleic acid concentration all below 10
IU/mL. Conclusion: No human parvovirus B19 has been detected in human albumin, human intravenous immunoglobulin, or human rabies immunoglobulin. Human parvovirus B19 nucleic acid may exist in commercially available coagulation factor products, highlighting the need for enhanced screening of human parvovirus B19 nucleic acid in these products. It is also recommended that B19 viral nucleic acid testing be conducted on source plasma, particularly for coagulation factor products.

Result Analysis
Print
Save
E-mail