1.Prognostic Factors of Real-World Lung Adenocarcinoma Patients with Brain Metastases
Xiaohuan ZHAO ; Hui QIAO ; Qichen ZHANG ; Xiaoming HOU
Cancer Research on Prevention and Treatment 2025;52(8):692-697
Objective To identify the indicators associated with poor prognosis by retrospectively analyzing the clinical data of 129 patients with lung adenocarcinoma (LUAD) complicated by brain metastases (BMs). Methods We retrospectively assessed the clinical data of 129 LUAD patients with BMs who met the inclusion criteria. Follow-up was conducted through electronic medical record review and telephone consultations. Univariate survival analysis was performed using the Kaplan-Meier method with corresponding survival curves. Statistically significant variables identified in the univariate analysis were subsequently incorporated into a multivariate Cox proportional hazards regression model to further identify independent adverse prognostic factors affecting the survival of LUAD patients with BMs. Results The following factors were significantly associated with patient survival prognosis (P<0.05): pathological morphology, KPS score, number of BMs, presence of genetic variations, quantity of genetic variations, type of genetic variations, EGFR mutation status, Cyfra-211, and neutrophil-to-lymphocyte ratio (NLR) at initial diagnosis. Multivariate Cox regression analysis revealed that pathological morphology, KPS score, number of BMs, NLR at initial diagnosis, and presence of genetic variations served as independent prognostic factors for LUAD patients with BMs (P<0.05). Further analysis of the survival conditions of different treatment subgroups revealed that combined therapy could significantly increase the median survival period of patients, and the difference was statistically significant (P=0.034). Conclusion Solid and complex glandular structures, KPS score <80, ≥3 BMs, elevated NLR levels at initial diagnosis, and the presence of genetic alterations are identified as independent poor prognostic factors for LUAD patients with BMs. Combination therapy can significantly prolong the survival of patients.
2.The effectiveness and safety of a percutaneous controllable curved plasma radiofrequency ablation device of nucleus pulposus
Hao ZHOU ; Qianyi ZHANG ; Jiajie LU ; Tao WU ; Yituo CHEN ; Qichen ZHANG ; Xilei LI ; Haikang CAI ; Jie TANG
Chinese Journal of Clinical Medicine 2025;32(4):659-664
Objective To verify the safety and effectiveness of a new percutaneous controllable curved plasma radiofrequency instrument for nucleus pulposus ablation. Methods A new percutaneous controllable curved plasma radiofrequency instrument were designed (controllable curved group), and its ablation effect was compared with the currently used straight head non-bendable plasma ablation instrument (non-bendable group) on gross specimens. The ablation instrument was placed through the right intervertebral foramen, and continuous ablation on the same intervertebral disc was conducted for three times. The ablation range and trajectory were recorded, and the temperature changes in the front, back, left, and right of the ablation center during and 15 seconds after ablation were monitored by the inserted temperature probe. Results There were no difference in temperature changes in the front, back, right regions of the ablation center during and 15 seconds after ablation between the two groups. The temperature changes in the left region of the ablation center both during and 15 seconds after 3rd ablation were larger than those in the non-bendable group (P<0.01). Compared with the non-bendable group, the controllable curved group achieved angle control and larger single ablation area (2.282 5 mm² vs 1.135 8 mm², P<0.000 1). Conclusions This new percutaneous controllable curved plasma ablation instrument can achieve angle control and ablation on the side opposite to the puncture site, increase ablation volume, and is safe.
3.Efficacy and safety of upadacitinib through 140 weeks in Chinese adult and adolescent patients with moderate-to-severe atopic dermatitis: Post hoc analysis of the phase 3 Measure Up 1 and AD Up clinical trials.
Li ZHANG ; Jinhua XU ; Chaoying GU ; Min ZHENG ; Meng PAN ; Linfeng LI ; Michael LANE ; Andrew PLATT ; Shereen HAMMAD ; Qichen FAN ; Xinghua GAO
Chinese Medical Journal 2025;138(13):1633-1634
4.Enhanced radiotheranostic targeting of integrin α5β1 with PEGylation-enabled peptide multidisplay platform (PEGibody): A strategy for prolonged tumor retention with fast blood clearance.
Siqi ZHANG ; Xiaohui MA ; Jiang WU ; Jieting SHEN ; Yuntao SHI ; Xingkai WANG ; Lin XIE ; Xiaona SUN ; Yuxuan WU ; Hao TIAN ; Xin GAO ; Xueyao CHEN ; Hongyi HUANG ; Lu CHEN ; Xuekai SONG ; Qichen HU ; Hailong ZHANG ; Feng WANG ; Zhao-Hui JIN ; Ming-Rong ZHANG ; Rui WANG ; Kuan HU
Acta Pharmaceutica Sinica B 2025;15(2):692-706
Peptide-based radiopharmaceuticals targeting integrin α5β1 show promise for precise tumor diagnosis and treatment. However, current peptide-based radioligands that target α5β1 demonstrate inadequate in vivo performance owing to limited tumor retention. The use of PEGylation to enhance the tumor retention of radiopharmaceuticals by prolonging blood circulation time poses a risk of increased blood toxicity. Therefore, a PEGylation strategy that boosts tumor retention while minimizing blood circulation time is urgently needed. Here, we developed a PEGylation-enabled peptide multidisplay platform (PEGibody) for PR_b, an α5β1 targeting peptide. PEGibody generation involved PEGylation and self-assembly. [64Cu]QM-2303 PEGibodies displayed spherical nanoparticles ranging from 100 to 200 nm in diameter. Compared with non-PEGylated radioligands, [64Cu]QM-2303 demonstrated enhanced tumor retention time due to increased binding affinity and stability. Importantly, the biodistribution analysis confirmed rapid clearance of [64Cu]QM-2303 from the bloodstream. Administration of a single dose of [177Lu]QM-2303 led to robust antitumor efficacy. Furthermore, [64Cu]/[177Lu]QM-2303 exhibited low hematological and organ toxicity in both healthy and tumor-bearing mice. Therefore, this study presents a PEGibody-based radiotheranostic approach that enhances tumor retention time and provides long-lasting antitumor effects without prolonging blood circulation lifetime. The PEGibody-based radiopharmaceutical [64Cu]/[177Lu]QM-2303 shows great potential for positron emission tomography imaging-guided targeted radionuclide therapy for α5β1-overexpressing tumors.
5.Alteration of cognitive function in overweight and obese adolescents and its relationship with serum FGF21 levels
Rui HAN ; Qian WU ; Dan LIU ; Di CHENG ; Ying ZHANG ; Jiacheng NI ; Piao KANG ; Anran CHEN ; Shujie YU ; Qichen FANG ; Huating LI
Journal of Shanghai Jiaotong University(Medical Science) 2024;44(1):87-97
Objective·To evaluate the changes in cognitive function in overweight and obese adolescents,and explore the association between cognitive function and fibroblast growth factor 21(FGF21).Methods·A total of 175 adolescents from a senior high school in Shanghai were divided into normal weight group(n=50),overweight group(n=50)and obese group(n=75)based on their body mass index(BMI).General information,anthropometric data and laboratory testing indicators of the adolescents were collected and compared.The cognitive function of the three groups of adolescents was assessed by using the accuracy(ACC)and reaction time of Flanker task and n-back task.Enzyme-linked immunosorbent assay(ELISA)was used to detect the serum FGF21 level of the three groups of adolescents.Partial correlation analysis and multiple linear regression model were used to evaluate the correlation between cognitive task performance and anthropometric data and laboratory testing indicators.Results·Compared with the normal weight group,systolic blood pressure,diastolic blood pressure,and the levels of fasting plasma glucose,glycosylated hemoglobin and triacylglycerol in the obese group were higher(all P<0.05).Under congruent or incongruent stimulus conditions in the Flanker task,there was no significant difference in ACC between any two groups;compared with the normal weight and overweight groups,the reaction time of the adolescents in the obese group was prolonged(all P<0.05).In the n-back task,there were no significant differences in ACC between any two groups,while the obese group had longer reaction time in the 1-back and 2-back tasks compared to the normal weight and overweight groups(all P<0.05).Compared with the normal weight group,serum FGF21 levels of the adolescents in the obese group were higher(P=0.000).Partial correlation analysis showed that the reaction time of the adolescents in Flanker and n-back tasks was correlated with their BMI,body fat mass,waist circumference,waist-to-hip ratio and FGF21 level(all P<0.05).Multiple linear regression analysis further confirmed that BMI was associated with prolonged reaction time in cognitive-related behavioral tasks in the adolescents(all P<0.05),and FGF21 level was associated with ACC in the 2-back task(P=0.000)and reaction time in the incongruent stimulus condition(P=0.048).Conclusion·Overweight and obese adolescents have cognitive impairments,and BMI and serum FGF21 levels are associated with changes in their cognitive function.
6.Neoadjuvant sintilimab and apatinib combined with perioperative FLOT chemotherapy for locally advanced gastric cancer: A prospective, single-arm, phase II study.
Huinian ZHOU ; Bo LONG ; Zeyuan YU ; Junmin ZHU ; Hanteng YANG ; Changjiang LUO ; Wenjuan ZHANG ; Chi DONG ; Xiaoying GUAN ; Long LI ; Gengyuan ZHANG ; Hongtai CAO ; Shigong CHEN ; Linyan ZHOU ; Qichen HE ; Shiying GAN ; Xiangyan JIANG ; Qianlin GU ; Keshen WANG ; Wengui SHI ; Long QIN ; Zuoyi JIAO
Chinese Medical Journal 2024;137(21):2615-2617
7.Establishment of a candidate reference measurement procedure for the quantification of cyclosporine A,tacrolimus,sirolimus and everolimus in whole blood by ID-LC-MS/MS
Qingzhang ZENG ; Tianjiao ZHANG ; Qichen LONG ; Lizi JIN ; Li ZHANG ; Chuanbao ZHANG
Chinese Journal of Laboratory Medicine 2022;45(5):472-477
Objectives:To establish a candidate reference measurement procedure based on isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) for cyclosporin A, tacrolimus, sirolimus, and everolimus measurements in human whole blood.Methods:The isotope labeled cyclosporine A, tacrolimus, sirolimus, and everolimus were selected as the internal standards. Samples were accurately weighed while protein precipitation and solid phase extraction were selected for the sample preparation. The standard curve method was applied for quantification. The ultra-high liquid chromatography coupled with triple quadrupole mass spectrometer was used for analysis. The specificity, matrix effect, detection limit, quantification limit, precision, accuracy, and uncertainty of the method were evaluated.Results:The method showed good selectivity and specificity. No apparent interferences or matrix effects were found in the target analyte measurements. The detection limits and quantification limits of cyclosporin A, tacrolimus, sirolimus and everolimus met clinical requirements. Intra-batch coefficients of variation ( CV) were from 1.4% to 1.8% for CSA, from 1.7% to 2.8% for TAC, from 1.3% to 3.7% for SRL and from 2.3% to 3.2% for EVR, and total CVs were from 1.8% to 2.9% for CSA, from 1.7% to 3.8% for TAC, from 2.6% to 4.7% for SRL and from 3.5% to 4.6% for EVR. The relative recoveries were from 97.9% to 100.3% for CSA, from 98.4% to 103.1% for TAC, from 99.4% to 102.0% for SRL and from 98.3% to 99.4% for EVR, and the relative expanded uncertainties at four concentrations were from 4.2% to 4.4% for CSA, from 1.5% to 2.4% for TAC, from 4.4% to 4.9% for SRL and from 2.2% to 2.7% for EVR. Conclusion:A candidate reference measurement procedure for the cyclosporine A, tacrolimus, sirolimus, and everolimus in human whole blood was established by ID-LC-MS/MS.
8.Cross-Modal Interaction and Integration Through Stimulus-Specific Adaptation in the Thalamic Reticular Nucleus of Rats.
Yumei GONG ; Yuying ZHAI ; Xinyu DU ; Peirun SONG ; Haoxuan XU ; Qichen ZHANG ; Xiongjie YU
Neuroscience Bulletin 2022;38(7):785-795
Stimulus-specific adaptation (SSA), defined as a decrease in responses to a common stimulus that only partially generalizes to other rare stimuli, is a widespread phenomenon in the brain that is believed to be related to novelty detection. Although cross-modal sensory processing is also a widespread phenomenon, the interaction between the two phenomena is not well understood. In this study, the thalamic reticular nucleus (TRN), which is regarded as a hub of the attentional system that contains multi-modal neurons, was investigated. The results showed that SSA existed in an interactive oddball stimulation, which mimics stimulation changes from one modality to another. In the bimodal integration, SSA to bimodal stimulation was stronger than to visual stimulation alone but similar to auditory stimulation alone, which indicated a limited integrative effect. Collectively, the present results provide evidence for independent cross-modal processing in bimodal TRN neurons.
Acoustic Stimulation
;
Animals
;
Auditory Perception/physiology*
;
Geniculate Bodies
;
Rats
;
Rats, Wistar
;
Thalamic Nuclei/physiology*
9.Commutability Assessment of Candidate External Quality Assessment Materials for Aminotransferase Activity Measurements Based on Different Approaches in China
Qichen LONG ; Tianqi QI ; Tianjiao ZHANG ; Jing WANG ; Jie ZENG ; Ying YAN ; Meng WANG ; Wei HUANG ; Haijian ZHAO ; Wenxiang CHEN ; Chuanbao ZHANG
Annals of Laboratory Medicine 2021;41(1):68-76
Background:
Using commutable external quality assessment (EQA) materials is important for monitoring successful harmonization efforts. We assessed the commutability of four human serum pool (HSP) preparations to identify candidate EQA materials for alanine aminotransferase (ALT) and aspartate aminotransferase (AST) activity measurement.
Methods:
One set each of 85 clinical samples (CSs) was collected for ALT and AST activity measurement. The 15 candidate EQA materials included four types of HSP preparations (A to D): materials A, C, and D contained human original recombinant (HOR) aminotransferases; materials B was mixed leftover samples. The CSs and 15 candidate EQA materials were analyzed using seven routine assays, and the ln-transformed results were analyzed in 21 assay pairs. Commutability was assessed using Deming regression, with a 95% prediction interval (CLSI approach) and the difference in bias with an error component model (International Federation of Clinical Chemistry and Laboratory Medicine [IFCC] approach).
Results:
For ALT, all materials were commutable for 14–21 assay pairs according to the CLSI and IFCC approaches. For AST, B01-03 showed commutability for 14-21 assay pairs, and C01-03 and D01-03 showed commutability for no less than 10 assay pairs according to the two approaches. A01-06 were commutable for 9-16 assay pairs according to the CLSI approach, but for 6-9 assay pairs according to the IFCC approach.
Conclusions
Mixed leftover samples showed desirable commutability characteristics as candidate EQA materials for routine aminotransferase activity measurements. Human serum bases supplemented with HOR were commutable for most routine ALT activity measurements.
10.Establishing allowable total error for serum total folate in external quality assessment
Xilian YI ; Jiangtao ZHANG ; Weiyan ZHOU ; Tianjiao ZHANG ; Qichen LONG ; Jie ZENG ; Chuanbao ZHANG
Chinese Journal of Laboratory Medicine 2021;44(8):715-719
Objective:To establish the allowable total error (TEa) of the national external quality assessment (EQA) program in line with the current quality level of serum folate measurement in China.Methods:The data of serum total folate test in the clinical laboratory of a hospital in Beijing in 2016 were collected, and the Stata SE 15 software was used for Monte Carlo simulation to obtain the false-negative rate under different bias and inaccuracy conditions. The Origin Pro 9.1 software was used to make the contour figure. The TEa of serum total folate test is derived based on the acceptable false-negative rate. National EQA data of serum total folate in 2020 were collected to calculate the pass rate of participating laboratories and the laboratory pass rate of quality control products at each level under the five TEa derived from the analysis performance on clinical outcomes, biological variation, and the evaluation criterion of national EQA.Results:Based on the influence of analytical performance on clinical outcomes, the TEa was 10%. Under this TEa, the pass rate of the first EQA program of serum total folate in 2020 was more than 80%, and the pass rate of the second time was 73.1%. Under the minimum (46.57%) and appropriate level of TEa (15.52%) derived from biological variation and national EQA evaluation criterion, the pass rate of serum total folate in the two EQA programs in 2020 exceeded 85%.Conclusion:The analytical performance of serum total folate in China cannot meet the requirements of TEa derived based on the effect of analytical performance on clinical outcomes. An appropriate level of TEa derived based on biological variation (15.52%) is suggested as the recommended criterion for the TEa of serum total folate test.

Result Analysis
Print
Save
E-mail