1.Individual fit test of hearing protectors for noise workers in typical automobile manufacturing industry
Xuan LIU ; Xue ZHAO ; Jing LIU ; Xiaoxiao GUO ; Qiang ZENG
Journal of Public Health and Preventive Medicine 2026;37(2):79-83
Objective To explore the wearing status and actual noise reduction effect of hearing protectors among noise workers in a typical automobile manufacturing enterprise. Methods In April 2024, an occupational hazard factor testing was carried out in an automobile manufacturing industry, and at the same time, the hearing protection fit test was conducted for noise workers. Intervention and guidance were provided to those who did not pass the minimum standard of baseline PAR. The difference in PAR between baseline and post-intervention was compared, and the effectiveness of hearing protector wearing method training was evaluated. Results The exceeding rate of the company's noise operation post was 50.77% (66/130). The baseline PAR of the subjects with working experience of less than 15 years and wearing hearing protectors throughout noisy work was higher, and the differences were statistically significant (P<0.05). Compared with those with 80dB≤LEX, 8h<85dB, more research subjects with LEX, 8h≥85dB failed baseline PAR (39.13%). After intervention, the PAR of the subjects who did not pass the minimum standard of baseline PRA increased from 2.0 (0.0, 5.3) to 17.0 (14.8, 20.0), and the protection level was significantly improved, and the difference was statistically significant (P<0.01). Conclusion The individual fit test of hearing protector is an important means to evaluate the actual noise reduction level of hearing protector and guide the selection of hearing protection models. Corporate training can help improve the PAR of hearing protectors.
2.Prognostic significance of TRIM28 elevation in non-M3 acute myeloid leukemia
Siqi GONG ; Cong LI ; Mengmeng FAN ; Huiping WANG ; Wanqiu ZHANG ; Xue LIANG ; Qianshan TAO ; Qiang HONG ; Zhimin ZHAI
Acta Universitatis Medicinalis Anhui 2026;61(2):301-308
ObjectiveTo clarify the expression of TRIM28 in non-M3 acute myeloid leukemia (AML) and its correlation with clinical indicators and prognosis, and to further explore the effect of TRIM28 expression levels on the proliferation and apoptosis of AML cells using small interfering RNA. MethodsThe GSE34577 dataset was analyzed using R software to compare TRIM28 expression between healthy controls and non-M3 acute myeloid leukemia (AML) patients. Clinical samples from non-M3 AML patients were collected, with TRIM28 expression levels measured using real-time quantitative PCR (qPCR). The analysis focused on correlations between TRIM28 expression and various clinical indicators, treatment efficacy, and patient prognosis. Furthermore, small interfering RNA (siRNA) technology was employed to downregulate TRIM28 expression in human primary AML cells (HL60 cell line). The effects on cell proliferation and apoptosis were then assessed through CCK-8 assays and flow cytometry, respectively. ResultsThe results showed that TRIM28 was up-regulated in non-M3 AML of both online database GSE34577 and clinical samples (P<0.000 1), TRIM28 expression of new diagnosis group and relapsed refractory group was higher than iron deficiency anemia group (P<0.01), and there was no significance between different French-American-British classification systems subtype. TRIM28 expression was higher in non-M3 AML patients with a poor genetic prognosis stratified as moderate than in the good prognosis group, and TRIM28 expression was associated with NPM1 combined with the FLT3-ITD mutation, positively correlated with age, bone marrow blast, peripheral blood blast and white blood cell, negatively correlated with hemoglobin. In addition, interference TRIM28 greatly inhibited cell proliferation and promoted cell apoptosis. ConclusionThis study reveals that TRIM28 is highly expressed in non-M3 AML and associated with prognosis, and plays a key role in the proliferation and apoptosis of AML cells, suggesting that TRIM28 may serve as a novel therapeutic target for non-M3 AML.
3.Comparative analysis of the characteristics of imported malaria cases in Nanning City in 2024 and the same period of the previous year
Shu-lin WEI ; Zhi-qiang QU ; Yuan-yuan LUO ; Yan-cui HUANG ; Shu-qin DIAO ; Xue LI ; Sheng-long YANG ; Xiao-yu HUANG ; Mi-fang LUO
Acta Parasitologica et Medica Entomologica Sinica 2026;33(2):81-84
Objective To investigate the epidemiological characteristics of malaria and provide a basis for developing improved prevention and control measures. Methods Data were obtained from the Chinese Disease Prevention and Control Information System. Malaria surveillance data for Nanning City from January 1,2023, to December 31,2024, were exported from the Infectious Disease Reporting Information Management Subsystem. The characteristics of the two groups of malaria cases were compared. Results A total of 103 imported malaria cases were reported in Nanning City in 2024, representing a 38.32% decrease compared with the same period of the previous year. No statistically significant difference were observed between cases reported in 2023 and 2024 in terms of average age, gender ratio, proportion of parasite species, and monthly reporting distribution;however, statistically significant differences were found in the proportion of reporting areas and current residence areas(χ2= 13.572 and 10.355, respectively; P = 0.001 and 0.035, respectively). The proportion of cases reported in Shanglin County and the proportion of cases residing in Shanglin County were both lower than those during the same period of the previous year. Conclusions The high aggregation of imported malaria cases in Nanning City has decreased. Medical institutions in areas other than Shanglin County should strengthen their vigilance against malaria.
4.Characteristics and influencing factors of hearing loss caused by occupational noise exposure in an automobile manufacturing enterprise
Xiaoxiao GUO ; Xuan LIU ; Xue ZHAO ; Jing LIU ; Qiang ZENG
Journal of Public Health and Preventive Medicine 2026;37(4):21-25
Objective To analyze the increase in hearing thresholds in different frequency bands of workers exposed to different characteristic noises and the influencing factors of binaural high-frequency hearing loss, and to provide theoretical support for occupational health monitoring in enterprises. Methods In 2021, noise-exposed workers were selected from typical noise-exposing enterprises as research subjects, and their occupational health examination data were tracked for three consecutive years. According to the on-site detection from 2021 to 2023, the cumulative noise exposure (CNE) was calculated. The chi-square test was used to compare the increase of the hearing threshold of workers exposed to different characteristic noises in different frequency bands. A generalized estimation equation was constructed to explore the influencing factors of high-frequency hearing loss in the research subjects. Results The age of the study subjects was 23-54 years old, with 1.6-20.1 years of working experience, mainly distributed in manufacturing workshops, technical workshops and public works workshops. The median LAeq,8h was 85.90 (84.5, 86.1) dB(A), and the average CNE was 94.3±2.6 dB(A). The number of people with increased hearing thresholds in each frequency band was 0.5kHz>6kHz>4kHz>3kHz>1kHz>2kHz. There were statistically significant differences in the increase of hearing thresholds in each frequency band, binaural speech frequency impairment, and high-frequency hearing loss among subjects with different characteristics (P<0.05). The detection rate of binaural speech frequency hearing loss was the highest in subjects aged>45 years, with a length of service of>15 years, and with a CNE>96dB(A). The detection rate of binaural high-frequency hearing loss was the highest in subjects aged 35-40 years, with a length of service of 5-10 years, and with a CNE>96dB(A).In addition, the detection rate of binaural speech frequency and high-frequency hearing loss increased with the increase of CNE(P<0.05). The GEE model showed that age>40 years and CNE>96dB(A) were risk factors for high-frequency hearing loss in both ears. Conclusion With increasing age and CNE, hearing thresholds rise across all frequency bands, elevating the risk of binaural speech-frequency and high-frequency hearing loss, thereby increasing the likelihood of occupational noise-induced deafness.
5.Discriminating Tumor Deposits From Metastatic Lymph Nodes in Rectal Cancer: A Pilot Study Utilizing Dynamic Contrast-Enhanced MRI
Xue-han WU ; Yu-tao QUE ; Xin-yue YANG ; Zi-qiang WEN ; Yu-ru MA ; Zhi-wen ZHANG ; Quan-meng LIU ; Wen-jie FAN ; Li DING ; Yue-jiao LANG ; Yun-zhu WU ; Jian-peng YUAN ; Shen-ping YU ; Yi-yan LIU ; Yan CHEN
Korean Journal of Radiology 2025;26(5):400-410
Objective:
To evaluate the feasibility of dynamic contrast-enhanced MRI (DCE-MRI) in differentiating tumor deposits (TDs) from metastatic lymph nodes (MLNs) in rectal cancer.
Materials and Methods:
A retrospective analysis was conducted on 70 patients with rectal cancer, including 168 lesions (70 TDs and 98 MLNs confirmed by histopathology), who underwent pretreatment MRI and subsequent surgery between March 2019 and December 2022. The morphological characteristics of TDs and MLNs, along with quantitative parameters derived from DCE-MRI (K trans , kep, and v e) and DWI (ADCmin, ADCmax, and ADCmean), were analyzed and compared between the two groups.Multivariable binary logistic regression and receiver operating characteristic (ROC) curve analyses were performed to assess the diagnostic performance of significant individual quantitative parameters and combined parameters in distinguishing TDs from MLNs.
Results:
All morphological features, including size, shape, border, and signal intensity, as well as all DCE-MRI parameters showed significant differences between TDs and MLNs (all P < 0.05). However, ADC values did not demonstrate significant differences (all P > 0.05). Among the single quantitative parameters, v e had the highest diagnostic accuracy, with an area under the ROC curve (AUC) of 0.772 for distinguishing TDs from MLNs. A multivariable logistic regression model incorporating short axis, border, v e, and ADC mean improved diagnostic performance, achieving an AUC of 0.833 (P = 0.027).
Conclusion
The combination of morphological features, DCE-MRI parameters, and ADC values can effectively aid in the preoperative differentiation of TDs from MLNs in rectal cancer.
6.Discriminating Tumor Deposits From Metastatic Lymph Nodes in Rectal Cancer: A Pilot Study Utilizing Dynamic Contrast-Enhanced MRI
Xue-han WU ; Yu-tao QUE ; Xin-yue YANG ; Zi-qiang WEN ; Yu-ru MA ; Zhi-wen ZHANG ; Quan-meng LIU ; Wen-jie FAN ; Li DING ; Yue-jiao LANG ; Yun-zhu WU ; Jian-peng YUAN ; Shen-ping YU ; Yi-yan LIU ; Yan CHEN
Korean Journal of Radiology 2025;26(5):400-410
Objective:
To evaluate the feasibility of dynamic contrast-enhanced MRI (DCE-MRI) in differentiating tumor deposits (TDs) from metastatic lymph nodes (MLNs) in rectal cancer.
Materials and Methods:
A retrospective analysis was conducted on 70 patients with rectal cancer, including 168 lesions (70 TDs and 98 MLNs confirmed by histopathology), who underwent pretreatment MRI and subsequent surgery between March 2019 and December 2022. The morphological characteristics of TDs and MLNs, along with quantitative parameters derived from DCE-MRI (K trans , kep, and v e) and DWI (ADCmin, ADCmax, and ADCmean), were analyzed and compared between the two groups.Multivariable binary logistic regression and receiver operating characteristic (ROC) curve analyses were performed to assess the diagnostic performance of significant individual quantitative parameters and combined parameters in distinguishing TDs from MLNs.
Results:
All morphological features, including size, shape, border, and signal intensity, as well as all DCE-MRI parameters showed significant differences between TDs and MLNs (all P < 0.05). However, ADC values did not demonstrate significant differences (all P > 0.05). Among the single quantitative parameters, v e had the highest diagnostic accuracy, with an area under the ROC curve (AUC) of 0.772 for distinguishing TDs from MLNs. A multivariable logistic regression model incorporating short axis, border, v e, and ADC mean improved diagnostic performance, achieving an AUC of 0.833 (P = 0.027).
Conclusion
The combination of morphological features, DCE-MRI parameters, and ADC values can effectively aid in the preoperative differentiation of TDs from MLNs in rectal cancer.
7.Rapid Video Analysis for Contraction Synchrony of Human Induced Pluripotent Stem Cells-Derived Cardiac Tissues
Yuqing JIANG ; Mingcheng XUE ; Lu OU ; Huiquan WU ; Jianhui YANG ; Wangzihan ZHANG ; Zhuomin ZHOU ; Qiang GAO ; Bin LIN ; Weiwei KONG ; Songyue CHEN ; Daoheng SUN
Tissue Engineering and Regenerative Medicine 2025;22(2):211-224
BACKGROUND:
The contraction behaviors of cardiomyocytes (CMs), especially contraction synchrony, are crucial factors reflecting their maturity and response to drugs. A wider field of view helps to observe more pronounced synchrony differences, but the accompanied greater computational load, requiring more computing power or longer computational time.
METHODS:
We proposed a method that directly correlates variations in optical field brightness with cardiac tissue contraction status (CVB method), based on principles from physics and photometry, for rapid video analysis in wide field of view to obtain contraction parameters, such as period and contraction propagation direction and speed.
RESULTS:
Through video analysis of human induced pluripotent stem cell (hiPSC)-derived CMs labeled with green fluorescent protein (GFP) cultured on aligned and random nanofiber scaffolds, the CVB method was demonstrated to obtain contraction parameters and quantify the direction and speed of contraction within regions of interest (ROIs) in wide field of view. The CVB method required less computation time compared to one of the contour tracking methods, the LucasKanade (LK) optical flow method, and provided better stability and accuracy in the results.
CONCLUSION
This method has a smaller computational load, is less affected by motion blur and out-of-focus conditions, and provides a potential tool for accurate and rapid analysis of cardiac tissue contraction synchrony in wide field of view without the need for more powerful hardware.
8.Rapid Video Analysis for Contraction Synchrony of Human Induced Pluripotent Stem Cells-Derived Cardiac Tissues
Yuqing JIANG ; Mingcheng XUE ; Lu OU ; Huiquan WU ; Jianhui YANG ; Wangzihan ZHANG ; Zhuomin ZHOU ; Qiang GAO ; Bin LIN ; Weiwei KONG ; Songyue CHEN ; Daoheng SUN
Tissue Engineering and Regenerative Medicine 2025;22(2):211-224
BACKGROUND:
The contraction behaviors of cardiomyocytes (CMs), especially contraction synchrony, are crucial factors reflecting their maturity and response to drugs. A wider field of view helps to observe more pronounced synchrony differences, but the accompanied greater computational load, requiring more computing power or longer computational time.
METHODS:
We proposed a method that directly correlates variations in optical field brightness with cardiac tissue contraction status (CVB method), based on principles from physics and photometry, for rapid video analysis in wide field of view to obtain contraction parameters, such as period and contraction propagation direction and speed.
RESULTS:
Through video analysis of human induced pluripotent stem cell (hiPSC)-derived CMs labeled with green fluorescent protein (GFP) cultured on aligned and random nanofiber scaffolds, the CVB method was demonstrated to obtain contraction parameters and quantify the direction and speed of contraction within regions of interest (ROIs) in wide field of view. The CVB method required less computation time compared to one of the contour tracking methods, the LucasKanade (LK) optical flow method, and provided better stability and accuracy in the results.
CONCLUSION
This method has a smaller computational load, is less affected by motion blur and out-of-focus conditions, and provides a potential tool for accurate and rapid analysis of cardiac tissue contraction synchrony in wide field of view without the need for more powerful hardware.
9.Erratum: Author correction to "Up-regulation of glyclipid transfer protein by bicyclol causes spontaneous restriction of hepatitis C virus replication" Acta Pharm Sin B 9 (2019) 769-781.
Menghao HUANG ; Hu LI ; Rong XUE ; Jianrui LI ; Lihua WANG ; Junjun CHENG ; Zhouyi WU ; Wenjing LI ; Jinhua CHEN ; Xiaoqin LV ; Qiang LI ; Pei LAN ; Limin ZHAO ; Yongfeng YANG ; Zonggen PENG ; Jiandong JIANG
Acta Pharmaceutica Sinica B 2025;15(3):1721-1721
[This corrects the article DOI: 10.1016/j.apsb.2019.01.013.].


Result Analysis
Print
Save
E-mail