1.Unveiling and Validating a Modified Method to Assess Cervical Sagittal Alignment as an Effective Substitute for Conventional C2-7 Cobb Angle
Wenpeng LI ; Qiwei WANG ; Qiancheng ZHAO ; Ziliang ZENG ; Xumin HU ; Xin LV ; Liangbin GAO
Clinics in Orthopedic Surgery 2025;17(1):130-137
Background:
Developing and validating a modified parameter, the SYS-G angle (the angle between the lower endplate of the C2 and the upper endplate of C7 vertebrae), as a feasible substitute for the C2–C7 Cobb method in assessing cervical sagittal alignment and exploring its reference range through a large-scale retrospective study.
Methods:
The visibility of the C6, C7 upper, and C7 lower endplates was graded and compared. Baseline data such as height, weight, body mass index (BMI), age, and sex were analyzed for their impact on the visibility of the C7 lower endplate. Values of C2-6 Cobb angle, SYS-G angle, and C2-7 Cobb angle were measured. The intra- and interobserver reliability, differences, and efficacy of evaluation on cervical lordosis of the parameters were compared, and the correlations among the parameters were analyzed. Furthermore, reference ranges for the SYS-G angle were established based on lateral cervical spine x-rays of 825 asymptomatic Chinese adults across different age groups and sexes.
Results:
The visibility of the C7 lower endplates was significantly reduced compared to the C6 lower and C7 upper endplates.Age, weight, BMI, and male sex were identified as factors negatively influencing the visibility of the C7 lower endplate. Both intraobserver and interobserver reliability demonstrated excellence for all tested parameters. The linear regression model unveiled a stronger association of the SYS-G angle with the C2-7 Cobb angle compared to the C2-6 Cobb angle. Furthermore, the SYS-G angle exhibited excellent efficacy in evaluating cervical lordosis. Age displayed a positive correlation with the SYS-G angle, and across every age bracket from 20 to 69 years, men exhibited a higher mean SYS-G angle compared to women.
Conclusions
The visibility of the C7 lower endplate diminishes with increasing age, weight, BMI, and male sex. In cases where the C7 lower endplate is unclear, the SYS-G angle emerges as a reliable method for estimating cervical sagittal morphology. Reference ranges for the SYS-G angle were established across various age groups and sexes among asymptomatic Chinese adults, offering a valuable resource to guide therapeutic interventions for cervical spine disorders and deformities.
2.Unveiling and Validating a Modified Method to Assess Cervical Sagittal Alignment as an Effective Substitute for Conventional C2-7 Cobb Angle
Wenpeng LI ; Qiwei WANG ; Qiancheng ZHAO ; Ziliang ZENG ; Xumin HU ; Xin LV ; Liangbin GAO
Clinics in Orthopedic Surgery 2025;17(1):130-137
Background:
Developing and validating a modified parameter, the SYS-G angle (the angle between the lower endplate of the C2 and the upper endplate of C7 vertebrae), as a feasible substitute for the C2–C7 Cobb method in assessing cervical sagittal alignment and exploring its reference range through a large-scale retrospective study.
Methods:
The visibility of the C6, C7 upper, and C7 lower endplates was graded and compared. Baseline data such as height, weight, body mass index (BMI), age, and sex were analyzed for their impact on the visibility of the C7 lower endplate. Values of C2-6 Cobb angle, SYS-G angle, and C2-7 Cobb angle were measured. The intra- and interobserver reliability, differences, and efficacy of evaluation on cervical lordosis of the parameters were compared, and the correlations among the parameters were analyzed. Furthermore, reference ranges for the SYS-G angle were established based on lateral cervical spine x-rays of 825 asymptomatic Chinese adults across different age groups and sexes.
Results:
The visibility of the C7 lower endplates was significantly reduced compared to the C6 lower and C7 upper endplates.Age, weight, BMI, and male sex were identified as factors negatively influencing the visibility of the C7 lower endplate. Both intraobserver and interobserver reliability demonstrated excellence for all tested parameters. The linear regression model unveiled a stronger association of the SYS-G angle with the C2-7 Cobb angle compared to the C2-6 Cobb angle. Furthermore, the SYS-G angle exhibited excellent efficacy in evaluating cervical lordosis. Age displayed a positive correlation with the SYS-G angle, and across every age bracket from 20 to 69 years, men exhibited a higher mean SYS-G angle compared to women.
Conclusions
The visibility of the C7 lower endplate diminishes with increasing age, weight, BMI, and male sex. In cases where the C7 lower endplate is unclear, the SYS-G angle emerges as a reliable method for estimating cervical sagittal morphology. Reference ranges for the SYS-G angle were established across various age groups and sexes among asymptomatic Chinese adults, offering a valuable resource to guide therapeutic interventions for cervical spine disorders and deformities.
3.Unveiling and Validating a Modified Method to Assess Cervical Sagittal Alignment as an Effective Substitute for Conventional C2-7 Cobb Angle
Wenpeng LI ; Qiwei WANG ; Qiancheng ZHAO ; Ziliang ZENG ; Xumin HU ; Xin LV ; Liangbin GAO
Clinics in Orthopedic Surgery 2025;17(1):130-137
Background:
Developing and validating a modified parameter, the SYS-G angle (the angle between the lower endplate of the C2 and the upper endplate of C7 vertebrae), as a feasible substitute for the C2–C7 Cobb method in assessing cervical sagittal alignment and exploring its reference range through a large-scale retrospective study.
Methods:
The visibility of the C6, C7 upper, and C7 lower endplates was graded and compared. Baseline data such as height, weight, body mass index (BMI), age, and sex were analyzed for their impact on the visibility of the C7 lower endplate. Values of C2-6 Cobb angle, SYS-G angle, and C2-7 Cobb angle were measured. The intra- and interobserver reliability, differences, and efficacy of evaluation on cervical lordosis of the parameters were compared, and the correlations among the parameters were analyzed. Furthermore, reference ranges for the SYS-G angle were established based on lateral cervical spine x-rays of 825 asymptomatic Chinese adults across different age groups and sexes.
Results:
The visibility of the C7 lower endplates was significantly reduced compared to the C6 lower and C7 upper endplates.Age, weight, BMI, and male sex were identified as factors negatively influencing the visibility of the C7 lower endplate. Both intraobserver and interobserver reliability demonstrated excellence for all tested parameters. The linear regression model unveiled a stronger association of the SYS-G angle with the C2-7 Cobb angle compared to the C2-6 Cobb angle. Furthermore, the SYS-G angle exhibited excellent efficacy in evaluating cervical lordosis. Age displayed a positive correlation with the SYS-G angle, and across every age bracket from 20 to 69 years, men exhibited a higher mean SYS-G angle compared to women.
Conclusions
The visibility of the C7 lower endplate diminishes with increasing age, weight, BMI, and male sex. In cases where the C7 lower endplate is unclear, the SYS-G angle emerges as a reliable method for estimating cervical sagittal morphology. Reference ranges for the SYS-G angle were established across various age groups and sexes among asymptomatic Chinese adults, offering a valuable resource to guide therapeutic interventions for cervical spine disorders and deformities.
4.Unveiling and Validating a Modified Method to Assess Cervical Sagittal Alignment as an Effective Substitute for Conventional C2-7 Cobb Angle
Wenpeng LI ; Qiwei WANG ; Qiancheng ZHAO ; Ziliang ZENG ; Xumin HU ; Xin LV ; Liangbin GAO
Clinics in Orthopedic Surgery 2025;17(1):130-137
Background:
Developing and validating a modified parameter, the SYS-G angle (the angle between the lower endplate of the C2 and the upper endplate of C7 vertebrae), as a feasible substitute for the C2–C7 Cobb method in assessing cervical sagittal alignment and exploring its reference range through a large-scale retrospective study.
Methods:
The visibility of the C6, C7 upper, and C7 lower endplates was graded and compared. Baseline data such as height, weight, body mass index (BMI), age, and sex were analyzed for their impact on the visibility of the C7 lower endplate. Values of C2-6 Cobb angle, SYS-G angle, and C2-7 Cobb angle were measured. The intra- and interobserver reliability, differences, and efficacy of evaluation on cervical lordosis of the parameters were compared, and the correlations among the parameters were analyzed. Furthermore, reference ranges for the SYS-G angle were established based on lateral cervical spine x-rays of 825 asymptomatic Chinese adults across different age groups and sexes.
Results:
The visibility of the C7 lower endplates was significantly reduced compared to the C6 lower and C7 upper endplates.Age, weight, BMI, and male sex were identified as factors negatively influencing the visibility of the C7 lower endplate. Both intraobserver and interobserver reliability demonstrated excellence for all tested parameters. The linear regression model unveiled a stronger association of the SYS-G angle with the C2-7 Cobb angle compared to the C2-6 Cobb angle. Furthermore, the SYS-G angle exhibited excellent efficacy in evaluating cervical lordosis. Age displayed a positive correlation with the SYS-G angle, and across every age bracket from 20 to 69 years, men exhibited a higher mean SYS-G angle compared to women.
Conclusions
The visibility of the C7 lower endplate diminishes with increasing age, weight, BMI, and male sex. In cases where the C7 lower endplate is unclear, the SYS-G angle emerges as a reliable method for estimating cervical sagittal morphology. Reference ranges for the SYS-G angle were established across various age groups and sexes among asymptomatic Chinese adults, offering a valuable resource to guide therapeutic interventions for cervical spine disorders and deformities.
5.Adaptability Analysis of Different Failure Criteria on Hollow Cortical Bone Structure under Tensile and Compressive Fracture Simulation
Ruoxun FAN ; Yitong WANG ; Qiancheng MIAO ; Chen HU ; Zhengbin JIA
Journal of Medical Biomechanics 2025;40(1):86-92
Objective To explore the failure criterion that can accurately simulate the tensile and compressive fracture of hollow cortical bone structure.Methods Based on the previous compression and bending experimental data,the predicted results using different failure criteria were compared to determine the simulation accuracy.Results Under the compressive load,the differences in the fracture load between the simulations using the equivalent and invariant strain failure criteria and the experiment were less than 5%,indicating that these two failure criteria were suitable for predicting the cortical bone failure;under the bending load,the differences in the fracture load between the simulations using the equivalent and invariant strain failure criteria and the experiment were less than 5%,indicating that these two failure criteria could accurately predict the failure process.Conclusions The prediction accuracy using different failure criteria mainly depends on whether the strain growth rate conforms to the actual bone deformation.Too fast or too low strain growth rate will lead to premature or delayed structural fracture.The fracture simulation adopted in this study is suitable for most cortical bone structures,and can be used to determine the suitable failure criterion under different loads,so as to assist in obtaining the strength limit of cortical bone in various parts and provide data support for improving the simulation accuracy and grasping the condition of fracture occurrence in clinical practice.
6.Adaptability Analysis of Different Failure Criteria on Hollow Cortical Bone Structure under Tensile and Compressive Fracture Simulation
Ruoxun FAN ; Yitong WANG ; Qiancheng MIAO ; Chen HU ; Zhengbin JIA
Journal of Medical Biomechanics 2025;40(1):86-92
Objective To explore the failure criterion that can accurately simulate the tensile and compressive fracture of hollow cortical bone structure.Methods Based on the previous compression and bending experimental data,the predicted results using different failure criteria were compared to determine the simulation accuracy.Results Under the compressive load,the differences in the fracture load between the simulations using the equivalent and invariant strain failure criteria and the experiment were less than 5%,indicating that these two failure criteria were suitable for predicting the cortical bone failure;under the bending load,the differences in the fracture load between the simulations using the equivalent and invariant strain failure criteria and the experiment were less than 5%,indicating that these two failure criteria could accurately predict the failure process.Conclusions The prediction accuracy using different failure criteria mainly depends on whether the strain growth rate conforms to the actual bone deformation.Too fast or too low strain growth rate will lead to premature or delayed structural fracture.The fracture simulation adopted in this study is suitable for most cortical bone structures,and can be used to determine the suitable failure criterion under different loads,so as to assist in obtaining the strength limit of cortical bone in various parts and provide data support for improving the simulation accuracy and grasping the condition of fracture occurrence in clinical practice.
7.Multilevel Pedicle Subtraction Osteotomy for Correction of Thoracolumbar Kyphosis in Ankylosing Spondylitis: Clinical Effect and Biomechanical Evaluation
Xin LV ; Yelidana NUERTAI ; Qiwei WANG ; Di ZHANG ; Xumin HU ; Jiabao LIU ; Ziliang ZENG ; Renyuan HUANG ; Zhihao HUANG ; Qiancheng ZHAO ; Wenpeng LI ; Zhilei ZHANG ; Liangbin GAO
Neurospine 2024;21(1):231-243
Objective:
To compare the clinical outcomes and biomechanical characteristics of 1-, 2-, and 3-level pedicle subtraction osteotomy (PSO), and establish selection criteria based on preoperative radiographic parameters.
Methods:
Patients undergone PSO to treat ankylosing spondylitis from February 2009 to May 2019 in Sun Yat-sen Memorial Hospital of Sun Yat-sen University were enrolled. According to the quantity of osteotomy performed, the participants were divided into group A (1-level PSO, n = 24), group B (2-level PSO, n = 19), and group C (3-level PSO, n = 11). Clinical outcomes were assessed before surgery and at the final follow-up. Comparisons of the radiographic parameters and quality-of-life indicators were performed among and within these groups, and the selection criteria were established by regression. Finite element analysis was conducted to compare the biomechanical characteristics of the spine treated with different quantity of osteotomies under different working conditions.
Results:
Three-level PSO improved the sagittal parameters more significantly, but resulted in longer operative time and greater blood loss (p < 0.05). Greater stress was found in the proximal screws and proximal junction area of the vertebra in the model simulating 1-level PSO. Larger stress of screws and vertebra was observed at the distal end in the model simulating 3-level PSO.
Conclusion
Multilevel PSO works better for larger deformity correction than single-level PSO by allowing greater sagittal parameter correction and obtaining a better distribution of stress in the hardware construct, although with longer operation time and greater blood loss. Three-level osteotomy is recommended for the patients with preoperative of global kyphosis > 85.95°, T1 pelvic angle > 62.3°, sagittal vertical alignment > 299.55 mm, and pelvic tilt+ chin-brow vertical angle > 109.6°.
8.Multilevel Pedicle Subtraction Osteotomy for Correction of Thoracolumbar Kyphosis in Ankylosing Spondylitis: Clinical Effect and Biomechanical Evaluation
Xin LV ; Yelidana NUERTAI ; Qiwei WANG ; Di ZHANG ; Xumin HU ; Jiabao LIU ; Ziliang ZENG ; Renyuan HUANG ; Zhihao HUANG ; Qiancheng ZHAO ; Wenpeng LI ; Zhilei ZHANG ; Liangbin GAO
Neurospine 2024;21(1):231-243
Objective:
To compare the clinical outcomes and biomechanical characteristics of 1-, 2-, and 3-level pedicle subtraction osteotomy (PSO), and establish selection criteria based on preoperative radiographic parameters.
Methods:
Patients undergone PSO to treat ankylosing spondylitis from February 2009 to May 2019 in Sun Yat-sen Memorial Hospital of Sun Yat-sen University were enrolled. According to the quantity of osteotomy performed, the participants were divided into group A (1-level PSO, n = 24), group B (2-level PSO, n = 19), and group C (3-level PSO, n = 11). Clinical outcomes were assessed before surgery and at the final follow-up. Comparisons of the radiographic parameters and quality-of-life indicators were performed among and within these groups, and the selection criteria were established by regression. Finite element analysis was conducted to compare the biomechanical characteristics of the spine treated with different quantity of osteotomies under different working conditions.
Results:
Three-level PSO improved the sagittal parameters more significantly, but resulted in longer operative time and greater blood loss (p < 0.05). Greater stress was found in the proximal screws and proximal junction area of the vertebra in the model simulating 1-level PSO. Larger stress of screws and vertebra was observed at the distal end in the model simulating 3-level PSO.
Conclusion
Multilevel PSO works better for larger deformity correction than single-level PSO by allowing greater sagittal parameter correction and obtaining a better distribution of stress in the hardware construct, although with longer operation time and greater blood loss. Three-level osteotomy is recommended for the patients with preoperative of global kyphosis > 85.95°, T1 pelvic angle > 62.3°, sagittal vertical alignment > 299.55 mm, and pelvic tilt+ chin-brow vertical angle > 109.6°.
9.Multilevel Pedicle Subtraction Osteotomy for Correction of Thoracolumbar Kyphosis in Ankylosing Spondylitis: Clinical Effect and Biomechanical Evaluation
Xin LV ; Yelidana NUERTAI ; Qiwei WANG ; Di ZHANG ; Xumin HU ; Jiabao LIU ; Ziliang ZENG ; Renyuan HUANG ; Zhihao HUANG ; Qiancheng ZHAO ; Wenpeng LI ; Zhilei ZHANG ; Liangbin GAO
Neurospine 2024;21(1):231-243
Objective:
To compare the clinical outcomes and biomechanical characteristics of 1-, 2-, and 3-level pedicle subtraction osteotomy (PSO), and establish selection criteria based on preoperative radiographic parameters.
Methods:
Patients undergone PSO to treat ankylosing spondylitis from February 2009 to May 2019 in Sun Yat-sen Memorial Hospital of Sun Yat-sen University were enrolled. According to the quantity of osteotomy performed, the participants were divided into group A (1-level PSO, n = 24), group B (2-level PSO, n = 19), and group C (3-level PSO, n = 11). Clinical outcomes were assessed before surgery and at the final follow-up. Comparisons of the radiographic parameters and quality-of-life indicators were performed among and within these groups, and the selection criteria were established by regression. Finite element analysis was conducted to compare the biomechanical characteristics of the spine treated with different quantity of osteotomies under different working conditions.
Results:
Three-level PSO improved the sagittal parameters more significantly, but resulted in longer operative time and greater blood loss (p < 0.05). Greater stress was found in the proximal screws and proximal junction area of the vertebra in the model simulating 1-level PSO. Larger stress of screws and vertebra was observed at the distal end in the model simulating 3-level PSO.
Conclusion
Multilevel PSO works better for larger deformity correction than single-level PSO by allowing greater sagittal parameter correction and obtaining a better distribution of stress in the hardware construct, although with longer operation time and greater blood loss. Three-level osteotomy is recommended for the patients with preoperative of global kyphosis > 85.95°, T1 pelvic angle > 62.3°, sagittal vertical alignment > 299.55 mm, and pelvic tilt+ chin-brow vertical angle > 109.6°.
10.Research development on the interaction between neuroimmunity and inflammation in the treatment of depressive disorder by traditional Chinese medicine
Dongjing GUO ; Wenchao PAN ; Sijia WANG ; Qiancheng MAO ; Hongxiu ZHAGN ; Ke MA
Chinese Journal of Comparative Medicine 2024;34(8):167-177
Depression,a common mood disorder,has a complex pathogenesis.In recent years,the accelerated pace of life has been accompanied by an increase in the prevalence rate of depression,leading to extensive attention being given to this condition.External stress and inflammation synergize to damage blood vessel and brain functions,induce immune disorders,cause microglia activation,and increase the expression of pro-inflammatory cytokines and their receptors.Inflammatory reactions continue to escalate,which affects the normal metabolism and metabolism of the neurotransmitter system.The abnormal functioning of molecular pathways leads to mutations in brain cell and nerve genes,and further formation of the immune-inflammation-neuron cycle pathway becomes an important mechanism in the occurrence and development of depression.A large number of studies have shown that traditional Chinese medicines can improve depression symptoms by restoring neuroimmune inflammation homeostasis.This article explains neuroimmune inflammation's close connection with depression and its pathogenesis and reviews the role of various traditional Chinese medical therapies in improving and treating depression by participating in the regulation of neuroimmune inflammation.This review provides new perspectives on the precise treatment of depression and the development of immune-targeted drugs.

Result Analysis
Print
Save
E-mail