1.Comprehensive evaluation of benign and malignant pulmonary nodules using combined biological testing and imaging assessment in 1 017 patients: A retrospective cohort study
Lei ZHANG ; Zihao LI ; Nan LI ; Jun CHENG ; Feng ZHANG ; Pinghui XIA ; Wang LÜ ; ; Jian HU
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(01):60-66
Objective By combining biological detection and imaging evaluation, a clinical prediction model is constructed based on a large cohort to improve the accuracy of distinguishing between benign and malignant pulmonary nodules. Methods A retrospective analysis was conducted on the clinical data of the 32 627 patients with pulmonary nodules who underwent chest CT and testing for 7 types of lung cancer-related serum autoantibodies (7-AABs) at our hospital from January 2020 to April 2024. The univariate and multivariate logistic regression models were performed to screen independent risk factors for benign and malignant pulmonary nodules, based on which a nomogram model was established. The performance of the model was evaluated using receiver operating characteristic (ROC) curves, calibration curves, and decision curve analysis (DCA). Results A total of 1 017 patients with pulmonary nodules were included in the study. The training set consisted of 712 patients, including 291 males and 421 females, with a mean age of (58±12) years. The validation set included 305 patients, comprising 129 males and 176 females, with a mean age of (58±13) years. Univariate ROC curve analysis indicated that the combination of CT and 7-AABs testing achieved the highest area under the curve (AUC) value (0.794), surpassing the diagnostic efficacy of CT alone (AUC=0.667) or 7-AABs alone (AUC=0.514). Multivariate logistic regression analysis showed that radiological nodule diameter, nodule nature, and CT combined with 7-AABs detection were independent predictors, which were used to construct a nomogram prediction model. The AUC values for this model were 0.826 and 0.862 in the training and validation sets, respectively, demonstrating excellent performance in DCA. Conclusion The combination of 7-AABs with CT significantly enhances the accuracy of distinguishing between benign and malignant pulmonary nodules. The developed predictive model provides strong support for clinical decision-making and contributes to achieving precise diagnosis and treatment of pulmonary nodules.
2.Application of intermediate screw assisted reduction and fixation technique in treatment of Schatzker type Ⅴ and Ⅵ tibial plateau fractures.
Zhaodong WANG ; Keyou DUAN ; Yajun LIU ; Chen XU ; Zhonglian ZHU ; Pinghui ZHOU ; Jianzhong GUAN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(5):529-535
OBJECTIVE:
To explore effectiveness of intermediate screw assisted reduction and fixation technique in the treatment of Schatzker type Ⅴ and Ⅵ tibial plateau fractures.
METHODS:
A clinical data of 22 patients with Schatzker type Ⅴ and Ⅵ tibial plateau fractures, who were admitted between June 2022 and December 2023 and met the selection criteria, was retrospectively analyzed. During operation, the intermediate screw assisted reduction and fixation technique was used. There were 14 males and 8 females with an average age of 46.3 years (range, 17-65 years). The fractures were caused by traffic accident in 13 cases, by falls in 5 cases, and by falling from height in 4 cases. According to Schatzker classification criteria, 9 cases were type Ⅴ and 13 cases were type Ⅵ. The interval between injury and operation was 5-12 days (mean, 7.9 days). The operation time, intraoperative fluoroscopy times, and length of hospital stay were recorded. The range of motion of knee joint and Hospital for Special Surgery (HSS) score were recorded at last follow-up. X-ray films were taken to review the fracture healing. Rasmussen score, tibial plateau varus angle (TPVA), and posterior tibial slope (PTS) were estimated before operation, at immediate after operation, and at last follow-up in order to evaluate the fracture reduction effect and postoperative outcome.
RESULTS:
The operation time was 85-140 minutes (mean, 103.9 minutes). Intraoperative fluoroscopy was performed 7-15 times (mean, 10.1 times). All incisions healed by first intention after operation, and no complication such as nerve or blood vessel injury occurred. The length of hospital stay ranged from 8 to 17 days (mean, 12.4 days). All patients were followed up 10-22 months (mean, 14.8 months). At last follow-up, the range of motion of knee joint was 110°-140° (mean, 125°). HSS score was rated as excellent in 16 cases, good in 5 cases, and fair in 1 case, with an excellent and good rate of 95.5%. X-ray films reexamination showed that all fractures healed with the healing time of 12-17 weeks (mean, 14.8 weeks). No internal fixation failure occurred. Rasmussen score, TPVA, and PTS at immediate after operation and at last follow-up were significantly superior to those before operation ( P<0.05). And there was no significant difference between immediately after operation and last follow-up ( P>0.05).
CONCLUSION
The treatment of Schatzker type Ⅴ and Ⅵ tibial plateau fractures with intermediate screw assisted reduction and fixation technique is reliable, which can reduce the difficulty of reduction and fixation, improve the efficiency of reduction and fixation, reduce the operation time, achieve satisfactory reduction and fixation effect and postoperative prognosis, and achieve good recovery of knee joint function.
Humans
;
Tibial Fractures/diagnostic imaging*
;
Male
;
Female
;
Adult
;
Middle Aged
;
Bone Screws
;
Fracture Fixation, Internal/instrumentation*
;
Retrospective Studies
;
Adolescent
;
Aged
;
Young Adult
;
Treatment Outcome
;
Range of Motion, Articular
;
Operative Time
;
Length of Stay
;
Tibial Plateau Fractures
3.Application of V-shaped stealth decompression technique using ultrasonic bone scalpel in anterior surgery for adjacent two-level cervical spondylosis.
Zhaodong WANG ; Keyou DUAN ; Yajun LIU ; Chen XU ; Zhonglian ZHU ; Pinghui ZHOU ; Jianzhong GUAN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(6):741-747
OBJECTIVE:
To evaluate the effectiveness of V-shaped stealth decompression technique using ultrasonic bone scalpel in anterior surgery for adjacent two-level cervical spondylosis.
METHODS:
A clinical data of 41 patients with adjacent two-level cervical spondylosis, who admitted between January 2020 and December 2023 and met the selection criteria, was analyzed retrospectively. Among them, 22 cases were treated with anterior cervical discectomy and fusion (ACDF) assisted by V-shaped stealth decompression technique using ultrasonic bone scalpel (group A) and 19 cases with anterior cervical corpectomy and fusion (ACCF) (group B). There was no significant difference between the two groups in age, gender, disease duration, surgical segment, preoperative Japanese Orthopedic Association (JOA) score, neck dysfunction index (NDI), pain visual analogue scale (VAS) score, and the anteroposterior diameter of the spinal canal in the responsibility space of axial CT ( P>0.05). The operation time, intraoperative blood loss, postoperative drainage volume, hospital stay, complications during follow-up, JOA score, NDI, and VAS score at last follow-up, and the incidences of intervertebral fusion at 3 months after operation, and cage subsidence at last follow-up were compared between the two groups.
RESULTS:
The operations in the two groups were successfully completed. The operation time, intraoperative blood loss, postoperative drainage volume, and hospital stay in group A were significantly less than those in group B ( P<0.05). Two cases (9.1%) in group A and 4 cases (21.1%) in group B developed complications, with no significant difference in the incidence between the two groups ( P>0.05). All patients in the two groups were followed up 6-12 months (mean, 9.3 months). There was no significant difference in follow-up time between the two groups ( P>0.05). At last follow-up, the JOA score and VAS score in both groups significantly improved when compared with those before operation ( P<0.05). The change values of VAS score and the improvement rate of JOA score in group A were significantly superior to group B ( P<0.05). There was no significant difference in the change values of NDI and JOA score between the two group ( P>0.05). Imaging reexamination showed that the rate of intervertebral fusion at 3 months after operation was significantly higher in group A (81.8%) than in group B (52.6%) ( P<0.05), and all patients obtained bony intervertebral fusion at last follow-up. At last follow-up, 2 cases (9.1%) in group A and 11 cases (57.9%) in group B had cage sinking, and the difference in the incidence was significant ( P<0.05). No loosening or fracture of internal fixators occurred in all patients.
CONCLUSION
Using ultrasonic bone scalpel can transform single vertebral ACCF into two-segment ACDF in anterior cervical spondylosis surgery. The V-shaped stealth decompression technique is safe and efficient, with the advantages of minimal trauma, fewer postoperative complications, and rapid recovery of patients.
Humans
;
Spondylosis/surgery*
;
Male
;
Female
;
Middle Aged
;
Decompression, Surgical/instrumentation*
;
Retrospective Studies
;
Cervical Vertebrae/surgery*
;
Spinal Fusion/instrumentation*
;
Diskectomy/instrumentation*
;
Adult
;
Treatment Outcome
;
Aged
;
Ultrasonic Surgical Procedures/methods*
;
Operative Time
4.Surgical Perspective on Lung Cancer in 2024: Innovation and Challenges.
Pengxu KONG ; Xiaohan CHEN ; Wang LV ; Pinghui XIA ; Luming WANG ; Jian HU
Chinese Journal of Lung Cancer 2025;28(3):195-200
Lung cancer, a highly prevalent and deadly malignancy globally, poses a significant disease burden in China and is the leading cause of cancer death. Despite rapid advances in medicine, its incidence and mortality rates remain stubbornly high, making it a major challenge in public health. Against the backdrop of rapid progress in precision medicine, the paradigm of lung cancer treatment is shifting from single traditional therapy to multi-dimensional integration. This article comprehensively reviews the innovations and challenges in lung cancer surgery in 2024, aiming to explore the future development of surgical treatment with colleagues and to improve patients' quality of life and achieve the goal of "cure".
.
Humans
;
Lung Neoplasms/surgery*
5.Development and prospect of intelligent specialized disease-specific robots for thoracic surgery
Xuhua HUANG ; Jinming XU ; Xin WANG ; Wang LV ; Pinghui XIA ; Yiqing WANG ; Jian HU
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2022;29(09):1210-1216
The application of robots in thoracic surgery is mainly based on the da Vinci general surgery robot. With the popularization of artificial intelligence (AI) application scenarios, the combination of AI and robots is more closely, and there is a strong clinical demand and huge application space for the development of specialized disease-specific robotic systems for thoracic surgery. This article aims to systematically describe the history of the rise of specialized surgical robots and the status of the localization of surgical robots in China, propose the concept of applying AI to the research and development of integrated specialized disease-specific robots in thoracic surgery, and clarify the ethics and prospects that intelligent specialized disease-specific surgical robots will face.
6.Investigation on staff′s cognitive level of wearing and removing personal protective equipment in COVID-19 isolation wards of Wuhan Fangcang shelter hospital
Xiaofen ZHOU ; Xin QIAN ; Feili CAI ; Yufang CHEN ; Yimin XUE ; Gang CHEN ; Jinyi HE ; Siwen CHENG ; Pinghui HUANG ; Xiaoli ZHENG ; Shaojing LYU ; Weiwei WANG
Chinese Journal of Experimental and Clinical Virology 2020;34(6):573-577
Objective:To investigate the cognitive level of wearing and removing personal protective equipment in COVID-19 isolation wards of Wuhan Fangcang shelter hospital, and provide the scientific basis for the training of hospital protection. Methods:Cognitive level of wearing and removing personal protective equipment in Wuhan Fangcang shelter hospital were investigated by using a questionnaire which included 14 related scales, including putting on and off protective equipment, hand hygiene disinfection and so on.Results:The total scale score of non-medical workers was 48.82±9.65, which was lower than the total scale score of doctors (55.46±1.29) and nurses (55.0±2.36), P<0.05. The each score of 14 items in the scale of non-medical workers was all lower than those of doctors and nurses ( P<0.05). There were no significant differences in scale scores among doctors, nurses and medical technicians. The total score of the scale of non-medical workers in later period was 55.23±3.26, which was significantly higher than the total score of 44.50±10.14 in previous period, P<0.001. The total score of nurses and medical technicians in the later period was higher than those in the previous period, and the difference was statistically significant. There was no significant difference between the total score of the scale in the later period and that in the previous period. Conclusions:The cognition level of non-medical workers on wearing and removing personal protective devices was lower than those of doctors and nurses, strengthening the practice could improve cognition.
7.Correlation analysis between corneal biomechanical properties and high-order aberration in myopia
Yaohua ZHANG ; Yan WANG ; Rui DOU ; Pinghui WEI
Chinese Journal of Experimental Ophthalmology 2018;36(5):368-372
Objective To investigate the correlations between corneal biomechanical properties and corneal high-order aberrations (HOAs) in myopic eyes.Methods In this retrospective study,263 right eyes with myopia or myopic astigmatism were enrolled from January to October 2015 in Tianjin Eye Hospital.The values of first applanation time (A1T),first applanation length (A1L),first applanation velocity (A1V),second applanation time (A2T),second applanation length (A2L),second applanation velocity (A2V),highest concavity time (HCT),highest concavity deformation amplitude (HCDA),highest concavity peak distance (HCPD),highest concavity radius (HCR) and non-contact intraocular pressure (IOPnct) were measured using the corneal visualization Scheimpflug technology (Corvis ST).The central corneal thickness (CCT) and wavefront aberrations of the anterior,posterior surface,and the total cornea were measured with Pentacam.Pearson correlation and stepwise multivariate linear regression analysis were applied to analyze the correlations between biomechanical properties and corneal HOAs.This study follows the Helsinki declaration.The experiment was approved by the Ethic Committee of Tianjin Eye Hospital.Informed consent was signed from each patient.Results There was a correlation between biomechanical properties and corneal HOAs.Negative correlations were found between A1L and the spherical aberration,HOAs RMS of anterior surface,total RMS and HOAs RMS of the posterior surface and HOAs RMS of the total cornea (P<0.05).HCRs were negatively correlated with total RMS of the total cornea and the anterior surface (P<0.05).The A2V was correlated with various aberrations.Multiple stepwise linear regression model analysis showed that,the correlation between the aberrations of anterior surface and biomechanical parameters,and the correlations between the total corneal aberration and biomechanical parameters were weak,the correlations between the aberrations of posterior surface and biomechanical parameters were strong.Conclusions There is a correlation between the biomechanical properties and corneal HOAs.The changes of the corneal biomechanical properties are mainly associated with the posterior corneal aberrations,which may contribute to the early diagnosis of subclinical keratoconus or dilated corneal disease.
8.Early clinical outcomes of small incision lenticule extraction for different refractive myopia and astigmatism
Wei, ZHAO ; Yan, WANG ; Hua, LI ; Rui, DOU ; Jiamei, ZHANG ; Liuyang, LI ; Pinghui, WEI
Chinese Journal of Experimental Ophthalmology 2017;35(4):349-354
Background Small incision lenticule extraction (SMILE) is increasingly applied in the correction of myopia and astigmatism.However,the early clinical outcomes of SMILE for different refractive myopia and astigmatism is seldom reported.Objective This study was to investigate the safety,efficacy,predictability and early stability after SMILE in low,moderate and high myopia.Methods A series of cases-observational study was carried out.A total of 195 eyes of 108 myopic patients were enrolled in Tianjin Eye Hospital from May to December 2012 under the informed consent.The patients were divided into the low (≤-3.00 D),moderate (>-3.00 to-6.00 D) and high myopia (>-6.00 D) groups according to different diopters,with 57 eyes,76 eyes and 62 eyes,respectively.SMILE was performed on all the eyes.The uncorrected visual acuity (UCVA)(LogMAR),best corrected visual acuity (BCVA) (LogMAR),equivalent sphere (SE),intraocular pressure,anterior segment and corneal topography were examined before operation and 1 day,1 week,1 month and 3 months after operation to evaluate the effective index (postoperative UCVA/preoperative BCVA),safety index (postoperative BCVA/preoperative BCVA),predictability and early stability of SMILE.The linear regression analysis was used to analyze the relationships between the attempted refraction and the achieved refraction postoperative 3 months in three groups.Results The percentage of UCVA (LogMAR)<0.1 was 100%,97.1% and 92.8% in the low,moderate and high myopia group,respectively in 3 months after SMILE.The postoperative BCVA of all the operated eyes reached preoperative one.The residual SE was (-0.07±0.16),(-0.05 ±0.20) and (-0.08±0.27)D in the low,moderate and high myopia group,respectively in 3 months after SMILE.The percentage of residual SE±0.5 D was 100%,98.7% and 93.6% in the low,moderate and high group,and that of SE±1.0 D was 100% in all of the groups.The postoperative corrected SE was gradually increased with the raise of predicted SE in the low,moderate and high myopia groups (r=0.942,0.959,0.957,all at P<0.001).Conclusions SMILE is safe,effective,predictable and stable for the correction of low,moderate and high myopia.The corneal wound healing was slightly slower in the low myopia group than that in the moderate and high group.A slight regression of myopic power appears in high myopia eyes 3 months after SMILE.
9.Association between corneal volume change and corneal biomechanical property before and after small incision lenticule extraction in myopia
Pinghui, WEI ; Yan, WANG ; Hua, LI ; Rui, DOU ; jiamei, ZHANG ; Wei, ZHAO ; Liuyang, LI
Chinese Journal of Experimental Ophthalmology 2017;35(2):146-150
Background The relationship between corneal central thickness (CCT) and corneal biomechanical property does not reflect the effective amount of ablated tissue because CCT measures only the change in a single point.Corneal volume (CV) is a representative parameter of corneal morphology,and it can fully reflect corneal thickness and tissue distribution.Objective This study was to investigate the correlation between volumetric corneal changes and corneal biomechanical properties after small incision lenticule extraction (SMILE).Methods A prospective series cases-observational study was carried out.This study protocol was approved by Ethic Committee of Tianjin Eye Hospital,and written informed consent was obtained from each patient prior to entering the cohort.Sixty-seven right eyes of 67 myopia or myopic astigmatism patients who received SMILE in Tianjin Eye Hospital from June 2014 to July 2015 were included in this study.Before and 3 months after surgery,the CV at 3,3-5,5-7 and 7-10 mm (CV3,CV3-5,CV5-7,CV7-10) was measured by Pentacam anterior segment analysis system,and corneal hysteresis (CH) and corneal resistance factor (CRF) were obtained by ocular response analyzer (ORA).The changes of CV (ACV),CH (ACH) and CRF (ACRF) were calculated,and the correlations between ACV and ACH or ACRF were analyzed.Results CV3,CV3-5 and CV5-7 values after SMILE were significantly lower than those before SMILE (t =36.24,20.38,16.17,all at P< 0.001).The CH values before and after SMILE were (10.06± 1.11) mmHg and (8.10± 1.05) mmHg (1 mmHg =0.133 kPa),and the CRF values before and after SMILE were (10.40 ± 1.38) mmHg and (6.91 ± 1.19) mmHg,respectively,showing significant reduces after SMILE than before SMILE (t =16.71,27.41,both at P<0.001).Positive correlations were seen between the CV values at different corneal areas and CH value or CRF value.Moderate positive correlations were found between CV3 and CH or CRF (r =0.571,0.569;both at P<0.001) before surgery,and 3 months after surgery,a weak positive correlation was seen between ACV3 and ACH (r =0.394,P < 0.001) or a moderate positive correlation between ACV3 and ACRF (r=0.501,P<0.001).Conclusions The CV value is gradually increased from the central cornea to periphery cornea.The CV change is associated with CH and CRF changes after SMILE,and CV3 probably is a useful parameter for the evaluation of corneal biomechanics after refractive surgery.
10.Effects of Bushengyijing Fang Medicated Serum on Human Sperm Quality in Vitro
Pinghui DENG ; Jinxiong ZENG ; Ruyao WANG
Chinese Journal of Information on Traditional Chinese Medicine 2006;0(03):-
Objective To study the effect of Bushengyijing Fang medicated serum on human sperm quality in vitro. Methods Human sperm was co-cultured with Bushengyijing Fang medicated serum in vitro. Human sperm quality was evaluated by computer assisted semen analysis (CASA) and the sperm move high test. Results The co-cultured Bushengyijing Fang medicated serum significantly increased the sperm motion velocity (VAP, VCL, VSL) (P

Result Analysis
Print
Save
E-mail