1.A prediction model for mild cognitive impairment risk among the elderly
MA Zongkang ; LIU Xinglang ; LI Huihui ; HE Guowei ; YAN Ping ; ZHANG Chuanrong ; MA Xuan ; CHE Yajie ; YU Shan ; CHEN Fenghui
Journal of Preventive Medicine 2026;38(2):124-129
Objective:
To develop a prediction model for mild cognitive impairment (MCI) risk among the elderly, so as to provide a tool for MCI early screening.
Methods :
From July 2022 to September 2024, a multi-stage stratified random cluster sampling method was used to recruit permanent residents aged ≥65 years from the Xinjiang Uygur Autonomous Region as study participants. Data on sociodemographic characteristics, nutritional status, body composition indices, bone mineral density, and handgrip strength were collected through questionnaires and physical examinations. Sarcopenia was defined based on appendicular skeletal muscle index and handgrip strength. MCI was assessed using the Mini-Mental State Examination, with adjustments for educational level. Participants were randomly divided into a training set and a validation set in a 7∶3 ratio. LASSO regression and multivariable logistic regression models were employed to screen for predictors and construct an MCI risk prediction model. The predictive performance of the model was evaluated using receiver operating characteristic (ROC) curve and decision curve analysis (DCA).
Results:
A total of 1 641 participants were surveyed, including 755 males (46.01%) and 886 females (53.99%). The majority of participants were aged 65-<75 years, comprising 1 154 individuals (70.32%). MCI was detected in 517 participants, corresponding to a detection rate of 31.51%. Resultsfrom LASSO regression and multivariate logistic regression analysis showed that residence (rural, OR = 2.323, 95% CI: 1.682-3.210), age (75-<85 years, OR = 1.405, 95% CI: 1.019-1.937; ≥85 years, OR = 3.655, 95% CI: 1.696-7.875), educational level (primary school, OR = 0.341, 95% CI: 0.247-0.472; junior high school, OR = 0.255, 95% CI: 0.160-0.408; high school, OR = 0.286, 95% CI: 0.154-0.531; bachelor's degree or above, OR = 0.120, 95% CI: 0.041-0.351), history of alcohol consumption (yes, OR = 3.216, 95% CI: 2.164-4.779), risk of malnutrition (yes, OR = 1.464, 95% CI: 1.064-2.014), sarcopenia (yes, OR = 3.197, 95% CI: 2.332-4.385), and waist-to-hip ratio (abnormal, OR = 1.540, 95% CI: 1.159-2.048) were identified as predictive factors for MCI among the elderly. In the training set, the area under the ROC curve, sensitivity, and specificity were 0.788, 0.719, and 0.712, respectively. In the validation set, the corresponding values were 0.784, 0.913, and 0.542, respectively. DCA demonstrated that the model provided a higher clinical net benefit for predicting MCI risk when the risk threshold probability ranged from 0.124 to 0.764.
Conclusion
The prediction model developed in this study demonstrates good discriminative ability and clinical utility, indicating its substantial value for predicting the MCI risk among the elderly.
2.HER2 in Metastatic Colorectal Cancer: Diagnostic and Therapeutic Opportunities and Challenges
Zhao-Tao PAN ; Feng-Yu GAI ; Chen CHEN ; Tong LI ; Yan-Ping QING
Progress in Biochemistry and Biophysics 2026;53(4):936-950
Colorectal cancer (CRC) is the third most commonly diagnosed malignancy and the second leading cause of cancer-related mortality worldwide. Despite therapeutic advancements over recent decades, the prognosis for patients with metastatic CRC (mCRC) remains poor. Approximately 2%-4% of mCRC cases exhibit human epidermal growth factor receptor 2 (HER2) amplification or overexpression, defining a distinct molecular subtype. This HER2-positive status is strongly associated with primary resistance to anti-epidermal growth factor receptor (EGFR) therapies, which are the standard of care for patients with RAS wild-type tumors. Beyond its well-established role in breast and gastric cancers, HER2 has emerged as a pivotal biomarker and actionable therapeutic target in mCRC. However, selecting appropriate treatment strategies remains challenging due to patient heterogeneity and diverse molecular subtypes. This review systematically summarizes the molecular biology, diagnostic strategies, and advances in targeted therapies for HER2-positive mCRC. On the diagnostic front, we discuss the applications of immunohistochemistry (IHC), fluorescence in situ hybridization (FISH), next-generation sequencing (NGS), and circulating tumor DNA (ctDNA) detection technologies. We highlight discrepancies in diagnostic criteria across key clinical trials—such as HERACLES, DESTINY, and MOUNTAINEER—underscoring the urgent need for standardized, CRC-specific definitions to ensure consistent patient selection and comparability of efficacy data across studies. Although NGS enables comprehensive genomic profiling, its cost-effectiveness relative to traditional methods must be carefully considered. Therapeutically, we summarize clinical trial data for HER2-directed agents, including tyrosine kinase inhibitors (TKIs) such as tucatinib and lapatinib, monoclonal antibodies like trastuzumab, bispecific antibodies, and antibody-drug conjugates (ADCs) such as trastuzumab deruxtecan. We review dual-targeting strategies and note recent FDA approvals that represent significant milestones in second-line treatment. Additionally, we explore the potential of combining immune checkpoint inhibitors with HER2-targeted therapies to enhance antitumor immunity through mechanisms including antibody-dependent cellular cytotoxicity (ADCC) and modulation of the tumor microenvironment. ADCs enable precise delivery of cytotoxic payloads, reducing off-target toxicity while effectively inhibiting oncogenic pathways. A substantial portion of this review is dedicated to dissecting the molecular mechanisms underlying primary and acquired resistance to HER2-targeted therapies—persistent challenges that limit clinical benefit. These mechanisms include reactivation of downstream signaling pathways such as PI3K/AKT/mTOR and MAPK, concurrent mutations in genes like KRAS or BRAF, and alterations in HER2 expression that compromise treatment efficacy. For instance, specific HER2 mutations (e.g., L755S) can reduce drug binding affinity, while ctDNA monitoring facilitates early detection of emerging resistance clones during disease progression, thereby enabling timely therapeutic adjustments. Tumor heterogeneity and dynamic interactions with the microenvironment further complicate resistance patterns observed in clinical practice. HER2-targeted therapy represents a new frontier in precision oncology for mCRC, offering renewed hope for improving patient outcomes. Realizing this potential will require continued optimization of diagnostic algorithms and treatment workflows. Future efforts must focus on overcoming resistance, validating liquid biopsy approaches for dynamic monitoring, and establishing unified clinical guidelines. HER2 has become an essential biomarker for stratifying mCRC patients beyond traditional RAS and BRAF status, underscoring the shift from empiric treatment to biomarker-driven precision medicine. International, multidisciplinary collaboration will be critical to validate emerging biomarkers and refine treatment algorithms globally.
3.Analysis of risk factors for obstetric septic shock
Meiling TAN ; Xueyuan HU ; Yiqing XIONG ; Mingyu ZHENG ; Ping YAN ; Dan WANG
Academic Journal of Naval Medical University 2025;46(11):1496-1501
Objective To explore the risk factors for obstetric septic shock.Methods The clinical data of 122 obstetric sepsis patients from Jan.2013 to Apr.2025 were retrospectively analyzed.The patients were assigned to shock group(n=26)or non-shock group(n=96)based on whether they progressed to septic shock.Variables including age,body mass index,multiple pregnancy,sequential organ failure assessment(SOFA)score,organ dysfunction status,white blood cell count(WBC),neutrophil count(NEU),neutrophil ratio,platelet count,procalcitonin,C-reactive protein,lactate(Lac),and D-dimer were recorded.Multivariate logistic regression analysis was used to identify the independent risk factors for obstetric septic shock.The predictive efficacy of these factors was evaluated using receiver operating characteristic(ROC)curve analysis.Results The proportions of patients aged≥35 years,and those with respiratory,cardiac,or central nervous system dysfunction,were significantly higher in the shock group than in the non-shock group,and the SOFA score,WBC,NEU,neutrophil ratio and Lac level were significantly higher in the shock group(all P<0.05).Multivariate logistic regression analysis showed that increased NEU(odds ratio[OR]=1.093,95%confidence interval[CI]1.022-1.169,P=0.010)and age≥35 years(OR=3.433,95%CI 1.112-10.602,P=0.032)were independent risk factors for obstetric septic shock.ROC curve analysis showed that NEU had predictive value for obstetric septic shock(area under curve=0.741,95%CI 0.634-0.848),with an optimal cut-offvalue of 17.17×109/L.Conclusion Increased NEU and age≥35 years are independent risk factors for obstetric septic shock.NEU has predictive value for the development of obstetric septic shock and may serve as an important indicator for clinical assessment and timely treatment.
4.In-Situ Controlled Growth of NiCr Layered Double Hydroxide Nanosheets on Nichrome Alloy Fibers for Solid Phase Microextraction of Chlorophenols
Hai-Xia LIU ; Hong-Hong RAO ; Fang LIU ; Yan-Ping ZHENG ; Yong-Qiang JIANG
Chinese Journal of Analytical Chemistry 2025;53(3):481-491,后插1-后插4,封3
Nichrome(NiCr)wire with strong mechanical properties,excellent flexibility,good corrosion resistance and high thermal stability was selected as a promising fiber substrate to replace the fragile fused-silica counterpart.The NiCr layered double hydroxide nanosheets(NiCr LDHs NSs)were in-situ grown on the NiCr fiber substrate.Then,the extraction performance of the NiCr@NiCr LDHs NSs fiber was evaluated using four kinds of chlorophenol(CPs)as model compounds combined with high performance liquid chromatography-ultraviolet detection(HPLC-UV).The results showed that the assembled fibers exhibited superior extraction selectivity and enhanced extraction efficiency for CPs in comparison to commercial PA,PDMS,and PDMS/DVB fibers.Under the optimized experimental conditions,the established method showed good linearity in the range of 0.2-200 μg/L,with coefficient of determination(R2)>0.9989.The limits of detection(LODs)and limits of quantification(LOQs)were 0.050-0.157 μg/L and 0.165-0.502 μg/L,respectively.Relative standard deviations(RSDs)for intra-day and inter-day analyses ranged from 2.85%to 4.05%and from 3.16%to 4.96%,respectively.The developed method with the constructed fiber was applied to preconcentration and detection of different types of CPs in real water samples,showing satisfactory recoveries ranging from 80.0%to 106.9%,with RSDs of 3.12%-7.81%.Moreover,the NiCr@NiCr LDHs NSs fiber could maintain good extraction performance even after 240 extraction-desorption cycles.
5.Rapid Detection of p53 Gene Based on Rolling Circle Amplification and Berberine Hydrochloride
Jing-Yan ZHANG ; Yu-Ping ZHANG ; Lin-Hui XIE ; Hong ZHOU ; Si-Yao LUO ; Ying-Ping LUO
Chinese Journal of Analytical Chemistry 2025;53(5):785-793
In this work,a rapid and label-free sensing platform was designed for visual detection of p53 gene.The rolling circle amplification(RCA)process of the assay platform was activated by p53 gene to produce long DNA-wires,which could bound with berberine hydrochloride(BBH)and further enhanced its fluorescence.This method showed high sensitivity with a low detection limit of 5.63 pmol/L,and high specificity toward p53 gene over other interference materials,even for single-base mutation gene.The method could realize the visual detection of targets under the illumination of a UV lamp.In addition,the designed fluorescence detection platform was successfully applied to p53 gene analysis in 10% fetal bovine serum samples,and the relative standard deviation and the recoveries were 0.1% -1.2% and 99.5% -104.7%,respectively.This approach had satisfactory characteristics,such as low cost,label-free,rapidity,high sensitivity,good selectivity and anti-interference ability,and reliable detection capability for complex practical samples,demonstrating a promising prospect in the diagnosis and treatment of diseases,especially for cancer.
6.Study on Colorimetric Sensor Array Based on Enzymatic Method for Highly Selective Detection of Sarin
Lian-Bo JIANG ; Guo-Hong LIU ; Zhuang-Hu XU ; Jian LI ; Yong-Ling SHEN ; Cai-Xia XU ; Chuan-Qin ZANG ; Yan-Hua XIAO ; Dan-Ping LI ; Ting LIANG
Chinese Journal of Analytical Chemistry 2025;53(5):832-841,中插21-中插23
Sarin(GB)is a typical representative of nerve agents with high toxicity,and very low amount can cause death.GB can cause water and atmospheric environment poisoning,so the detection of GB in water and air is of great significance.In this work,a colorimetric sensor array(CSA)based on GB inhibition of cholinesterase activity was constructed to detect GB with high selectivity.A 4×4 colorimetric array was constructed using acetylcholinesterase(AChE),butyryl cholinesterase(BuChE)and the corresponding substrate acetylthiocholine iodide(S-ACh),butyryl thiocholine iodide(S-BCh),acetylcholine chloride(ACh),butyryl choline chloride(BCh)and 2,6-dichloroindophenol ethyl ester(DCIE).The linear curve of the sensor was Y=131.3×lgC+271.6(R2=0.997),where Y was the array response Euclidean distance,C was the concentration of GB(mg/L),the linear range was 0.03?0.32 mg/L,and the detection limit was 27.6 μg/L.The method could effectively distinguish chemical warfare agents(CWA)such as VX,Soman(GD),mustard gas(HD),Louie reagent(L),and had high anti-interference ability,sensitivity and good repeatability.It was successfully applied to the detection of GB in simulated water and simulated air samples,and the sample recovery rate was 97.2% ?100.9%.This method would be potentially applied to the field rapid detection of nerve agents.
7.Highly Sensitive Detection of Water in Organic Solvents Using Pyrene-Phenol-based Fluorescent Probe
Jing LIANG ; Yan-Li WANG ; Cui-Wen JIANG ; Xiao-Chuan HUANG ; Li TANG ; Tao LI ; Yu YA ; De-Jiao NING ; Li-Ping XIE ; Fei-Yan YAN
Chinese Journal of Analytical Chemistry 2025;53(6):894-902,中插1-中插5
A pyrene-phenol-based fluorescent probe PyP which showed typical intramolecular charge transfer(ICT)and monomer-excimer activities was synthesized by using pyrene carboxaldehyde hydrazone and 4-tert-butyl-2,6-diformylphenol as the raw materials.The effects of solvents on PyP were studied,and the results showed that the color of protic polar solvents(Ethanol,N,N-dimethylformamide,methanol and H2O)were successfully identified.Based on the solvent polarity-regulated PyP monomer-excimer switching,the rapid and highly sensitive ratiometric probe,"Turn-off"and"Turn-on"multimodal probes were established for detection of trace water content in organic solvents(Dimethyl sulfoxide,N,N-dimethylformamide,ethanol and methanol),with detection limits(3σ/k)of 0.0021%,0.046%,0.062%and 0.024%.The method was successfully used to detect water content in dimethyl sulfoxide,N,N-dimethy lformamide,ethanol and methanol commercial organic solvents,with recoveries ranging from 97.2%to 108.0%.The developed method showed good accuracy and stability,and had good application prospect.
8.Synthesis of A New Naphthalenesulfonamide-based"Turn-on"Fluorescent Probe for Rapid Detection of Glyphosate
Rong-Rong ZHAO ; Hong-Lin LIU ; Ying-Ping HUANG ; Cui-Wen DENG ; Song-Yan LI ; Shui-Lian YU ; Mao-Sheng TAO ; Yi-Qun TIAN ; Xi YUAN
Chinese Journal of Analytical Chemistry 2025;53(6):903-913
Widespread utilization of glyphosate has led to environmental residues,posing potential threats to ecological systems and human health.Traditional methods for detection of glyphosate are limited by specialized equipment and operational techniques,resulting in inefficient responses.Therefore,it is urgent to develop a convenient,sensitive and accurate detection method for detection of glyphosate.Herein,a new naphthalenesulfonamide-based"Turn-on"fluorescent probe was synthesized using 2-chloroaniline and dansyl chloride as raw materials through a one-step process,which showed a good linear relationship between the glyphosate concentration in concentration range of 0.003-70 μmol/L and the fluorescence intensity(R2=0.995),with a detection limit of 2.73 nmol/L(S/N=3).Analytical techniques such as nuclear magnetic resonance(NMR)spectroscopy and high-resolution mass spectrometry(HRMS)were used to investigate the interaction mechanism between the fluorescent probe and glyphosate.The results indicated that a nucleophilic substitution reaction occurred between the probe and the secondary amine(—NH—)of glyphosate,inducing a photoinduced electron transfer(PET)effect which enhanced the fluorescence intensity by 11.2 times.The probe showed good anti-interference ability towards coexisting metal ions,anions and pesticides in water.When applied to determination of glyphosate in the samples such as tap water,river water(Xiangxi River Reservoir),soil,soybeans,and corn,the spiking recoveries ranged from 94.7%to 109.9%,demonstrating the high accuracy and broad applicability of this detection method.A portable test strip based on this fluorescent probe was developed for rapid semi-quantitative analysis of glyphosate.The developed method was rapid,sensitive,and portable,providing theoretical and technical support for on-site measurement of environmental contaminants.
9.Validation and Forensic Application of a Domestic Human DNA Quantitative De-tection Kit
Jing CHEN ; Ya-Ping WANG ; Yun-Peng FENG ; Xiao-Xin HU ; Zhen-Jun JIA ; Hong-Di LIU ; An-Xin YAN ; Yong-Jiu LI ; Zhu PENG ; Zhi-Fang LIU ; Jian-Gang CHEN
Journal of Forensic Medicine 2025;41(3):252-259
Objective To verify the efficacy of a domestic human DNA quantification kit based on real-time fluorescence quantitative PCR in detecting the total human DNA concentration,male DNA concen-tration in mixed male/female DNA samples,the degree of DNA degradation and inhibitor tolerance.Methods Samples with different concentrations,different male/female ratios,different concentrations of inhibitors,and different degradation degrees were tested using the domestic human DNA quantification kit based on real-time fluorescence quantitative PCR.This kit was compared with a similar product on the market and was applied to the detection of DNA from real cases.Results This human DNA quan-tification kit can effectively detect human DNA as low as 0.001 65 ng/μL,and 6.25 pg/μL of male DNA in mixed samples with a male-to-female ratio of 1∶15 000.Even when the sample contains as high as 400 ng/μL of humic acid or 1 000 μmol/L of hemin alone,the DNA concentration can still be accurately detected.The degradation index can effectively characterize the degradation degree of the sample.This kit has been successfully applied in forensic practice.Conclusion This human DNA quan-tification kit is accurate and reliable in detection.It can accurately reflect the degradation of DNA and inhibitor tolerance.It has good performance in quantitative accuracy,determination of the male/female ratio in mixed samples,and inhibitor tolerance.It has application potential in forensic case examination.
10.Research Progress of Chirp ABR and Its Application in Forensic Auditory Identi-fication
Yan GAO ; Fang CHEN ; Wen-Tao XIA ; Xiao-Ping YANG ; Ze-Yu WANG ; Ze-Ren YANG ; Xia LIU ; Yan-Liang SHENG
Journal of Forensic Medicine 2025;41(4):387-393
The objective assessment of hearing loss is one of the critical components in forensic clini-cal research.Auditory brainstem response(ABR)is an important method for objectively assessing hearing levels.It is divided into various types based on different stimulus signals,each with its own characteris-tics and applications.Among them,narrow-band Chirp ABR,due to its frequency specificity,fulfills the basic requirements for objective assessment of forensic audiology,promising to be an important method of objective hearing assessment in forensic medicine.This article reviews the development history,charac-teristics and clinical applications of Chirp ABR,and envisions its application prospects in forensic audi-tory identification.


Result Analysis
Print
Save
E-mail