1.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
2.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
3.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
4.Safety and effectiveness of lecanemab in Chinese patients with early Alzheimer's disease: Evidence from a multidimensional real-world study.
Wenyan KANG ; Chao GAO ; Xiaoyan LI ; Xiaoxue WANG ; Huizhu ZHONG ; Qiao WEI ; Yonghua TANG ; Peijian HUANG ; Ruinan SHEN ; Lingyun CHEN ; Jing ZHANG ; Rong FANG ; Wei WEI ; Fengjuan ZHANG ; Gaiyan ZHOU ; Weihong YUAN ; Xi CHEN ; Zhao YANG ; Ying WU ; Wenli XU ; Shuo ZHU ; Liwen ZHANG ; Naying HE ; Weihuan FANG ; Miao ZHANG ; Yu ZHANG ; Huijun JU ; Yaya BAI ; Jun LIU
Chinese Medical Journal 2025;138(22):2907-2916
INTRODUCTION:
Lecanemab has shown promise in treating early Alzheimer's disease (AD), but its safety and efficacy in Chinese populations remain unexplored. This study aimed to evaluate the safety and 6-month clinical outcomes of lecanemab in Chinese patients with mild cognitive impairment (MCI) or mild AD.
METHODS:
In this single-arm, real-world study, participants with MCI due to AD or mild AD received biweekly intravenous lecanemab (10 mg/kg). The study was conducted at Hainan Branch, Ruijin Hospital Shanghai Jiao Tong University School of Medicine. Patient enrollment and baseline assessments commenced in November 2023. Safety assessments included monitoring for amyloid-related imaging abnormalities (ARIA) and other adverse events. Clinical and biomarker changes from baseline to 6 months were evaluated using cognitive scales (mini-mental state examination [MMSE], montreal cognitive assessment [MoCA], clinical dementia rating-sum of boxes [CDR-SB]), plasma biomarker analysis, and advanced neuroimaging.
RESULTS:
A total of 64 patients were enrolled in this ongoing real-world study. Safety analysis revealed predominantly mild adverse events, with infusion-related reactions (20.3%, 13/64) being the most common. Of these, 69.2% (9/13) occurred during the initial infusion and 84.6% (11/13) did not recur. ARIA-H (microhemorrhages/superficial siderosis) and ARIA-E (edema/effusion) were observed in 9.4% (6/64) and 3.1% (2/64) of participants, respectively, with only two symptomatic cases (one ARIA-E presenting with headache and one ARIA-H with visual disturbances). After 6 months of treatment, cognitive scores remained stable compared to baseline (MMSE: 22.33 ± 5.58 vs . 21.27 ± 4.30, P = 0.733; MoCA: 16.38 ± 6.67 vs . 15.90 ± 4.78, P = 0.785; CDR-SB: 2.30 ± 1.65 vs . 3.16 ± 1.72, P = 0.357), while significantly increasing plasma amyloid-β 42 (Aβ42) (+21.42%) and Aβ40 (+23.53%) levels compared to baseline.
CONCLUSIONS:
Lecanemab demonstrated a favorable safety profile in Chinese patients with early AD. Cognitive stability and biomarker changes over 6 months suggest potential efficacy, though high dropout rates and absence of a control group warrant cautious interpretation. These findings provide preliminary real-world evidence for lecanemab's use in China, supporting further investigation in larger controlled studies.
REGISTRATION
ClinicalTrials.gov , NCT07034222.
Humans
;
Alzheimer Disease/drug therapy*
;
Male
;
Female
;
Aged
;
Middle Aged
;
Cognitive Dysfunction/drug therapy*
;
Aged, 80 and over
;
Amyloid beta-Peptides/metabolism*
;
Biomarkers
;
East Asian People
5.Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience
Peijian WEI ; Yihang LI ; Liang XU ; Junyi WAN ; Fengwen ZHANG ; Gary TSE ; Jeffrey Shi Kai CHAN ; Shouzheng WANG ; Wenbin OUYANG ; Gejun ZHANG ; Fang FANG ; Xiangbin PAN
Korean Circulation Journal 2025;55(3):199-212
Background and Objectives:
There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce.
Methods:
Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66).
Results:
No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs.62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01).In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342).
Conclusions
Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.
6.Clinical efficacy of transcatheter edge-to-edge repair in patients with non-central degenerative mitral regurgitation
Peijian WEI ; Junke CHANG ; Jianrui MA ; Guangzhi ZHAO ; Jing DONG ; Cheng WANG ; Fengwen ZHANG ; Shiguo LI ; Fujian DUAN ; Wenbin OUYANG ; Shouzheng WANG ; Fang FANG ; Xiangbin PAN
Chinese Journal of Cardiology 2025;53(4):373-381
Objective:To evaluate the clinical efficacy of mitral valve transcatheter edge-to-edge repair (TEER) in patients with non-central degenerative mitral regurgitation (DMR).Methods:This retrospective study included patients with non-central DMR who underwent TEER at Fuwai Hospital between January 2021 and February 2024. Patients were categorized into two groups: the commissure-involved group and the non-commissure group, based on whether the mitral valve commissures were involved. Clinical data, surgical outcomes, and echocardiographic findings at 3 months postoperatively were collected and compared, and patients were followed up. The primary endpoint was the procedural success rate at discharge.Results:A total of 59 patients were included, aged (68.6±9.3) years, including 23 females (39%). In the overall study population, 78% (46/59) of patients had severe mitral regurgitation. Forty-two cases were in the non-commissure group, and 17 cases were in the commissure-involved group. Patients in the non-commissure group mainly had lesions in the A1/P1 region, while patients in the commissure-involved group mainly had lesions in the A3/P3 region. There was no significant difference in the procedural success rate at discharge (93% vs. 88%, P=0.95) and the incidence of postoperative complications (5% vs. 6%, P=1.00) between the two groups. Two patients in the commissure-involved group experienced single leaflet device attachment, with one of them requiring conversion to surgical mitral valve surgery; In the non-commissure group, two patients experienced single-valve clamping, and one of them was converted to surgical mitral valve surgery. The follow-up time of the entire cohort was (15.5±10.3) months. In the non-commissure group, 2 patients died and 2 were readmitted. While in the commissure-involved group, no patients died and only 1 patient was readmitted. Conclusion:TEER is an effective treatment for patients with non-central DMR involving the commissures, without increasing the incidence of postoperative complications.
7.Clinical efficacy of transcatheter edge-to-edge repair in patients with non-central degenerative mitral regurgitation
Peijian WEI ; Junke CHANG ; Jianrui MA ; Guangzhi ZHAO ; Jing DONG ; Cheng WANG ; Fengwen ZHANG ; Shiguo LI ; Fujian DUAN ; Wenbin OUYANG ; Shouzheng WANG ; Fang FANG ; Xiangbin PAN
Chinese Journal of Cardiology 2025;53(4):373-381
Objective:To evaluate the clinical efficacy of mitral valve transcatheter edge-to-edge repair (TEER) in patients with non-central degenerative mitral regurgitation (DMR).Methods:This retrospective study included patients with non-central DMR who underwent TEER at Fuwai Hospital between January 2021 and February 2024. Patients were categorized into two groups: the commissure-involved group and the non-commissure group, based on whether the mitral valve commissures were involved. Clinical data, surgical outcomes, and echocardiographic findings at 3 months postoperatively were collected and compared, and patients were followed up. The primary endpoint was the procedural success rate at discharge.Results:A total of 59 patients were included, aged (68.6±9.3) years, including 23 females (39%). In the overall study population, 78% (46/59) of patients had severe mitral regurgitation. Forty-two cases were in the non-commissure group, and 17 cases were in the commissure-involved group. Patients in the non-commissure group mainly had lesions in the A1/P1 region, while patients in the commissure-involved group mainly had lesions in the A3/P3 region. There was no significant difference in the procedural success rate at discharge (93% vs. 88%, P=0.95) and the incidence of postoperative complications (5% vs. 6%, P=1.00) between the two groups. Two patients in the commissure-involved group experienced single leaflet device attachment, with one of them requiring conversion to surgical mitral valve surgery; In the non-commissure group, two patients experienced single-valve clamping, and one of them was converted to surgical mitral valve surgery. The follow-up time of the entire cohort was (15.5±10.3) months. In the non-commissure group, 2 patients died and 2 were readmitted. While in the commissure-involved group, no patients died and only 1 patient was readmitted. Conclusion:TEER is an effective treatment for patients with non-central DMR involving the commissures, without increasing the incidence of postoperative complications.
8.Early clinical outcomes of the domestic KokaclipTM transcatheter edge-to-edge mitral valve repair system for severe degenerative mitral regurgitation: A single-arm, prospective, single-group target value clinical trial
Tong TAN ; Bingqi FU ; Peijian WEI ; Nianjin XIE ; Haozhong LIU ; Xiaoyi LI ; Shengwen WANG ; Haijiang GUO ; Jian LIU ; Jimei CHEN ; Jian ZHUANG ; Huiming GUO
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2024;31(02):269-275
Objective To summarize and analyze the preliminary clinical outcomes of the KokaclipTM transcatheter edge-to-edge mitral valve repair system for severe degenerative mitral regurgitation (DMR). Methods This study was a single-arm, prospective, single-group target value clinical trial that enrolled patients who underwent the KokaclipTM transcatheter edge-to-edge repair (TEER) system for DMR in the Department of Heart Surgery of Guangdong Provincial People's Hospital, Guangdong Cardiovascular Institute from June 2022 to January 2023. Differences in the grade of mitral regurgitation (MR) during the perioperative and follow-up periods were compared, and the incidences of adverse events such as all-cause death, thoracotomy conversion, reoperation, and severe recurrence of MR during the study period were investigated. Results The enrolled patient population consisted of 14 (50.0%) females with a mean age of 70.9±5.4 years. Twenty-eight (100.0%) patients were preoperatively diagnosed with typeⅡ DMR, with a prolapse width of 12.5 (11.0, 16.1) mm, a degree of regurgitation 4+ leading to pulmonary venous reflux, and a New York Heart Association cardiac function class≥Ⅲ. All patients completed the TEER procedure successfully, with immediate postoperative improvement of MR to 0, 1+, and 2+ grade in 2 (7.1%), 21 (75.0%), and 5 (17.9%) patients, respectively. Mitral valve gradient was 2.5 (2.0, 3.0) mm Hg. Deaths, thoracotomy conversion, or device complications such as unileaflet clamping, clip dislodgement, or leaflet injury were negative. Twenty-eight (100.0%) patients completed at least 3-month postoperative follow-up with a median follow-up time of 5.9 (3.6, 6.8) months, during which patients had a mean MR grade of 1.0+ (1.0+, 2.0+) grade and a significant improvement from preoperative values (P<0.001). There was no recurrence of ≥3+ regurgitation, pulmonary venous reflux, reoperation, new-onset mitral stenosis, or major adverse cardiovascular events. Twenty-two (78.6%) patients’ cardiac function improved to classⅠorⅡ. Conclusion The domestic KokaclipTM TEER system has shown excellent preliminary clinical results in selected DMR patients with a high safety profile and significant improvement in MR. Additional large sample volume, prospective, multicenter studies, and long-term follow-up are expected to validate the effectiveness of this system in the future.
9.Echo-guiding percutaneous aortic stent implantation for coarctation of the aortic: A case report
Junke CHANG ; Peijian WEI ; Yaoxing LU ; Fengwen ZHANG ; Fang FANG ; Chuangshi WANG ; Shouzheng WANG ; Wenbin OUYANG ; Junyi WAN ; Xiangbin PAN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2024;31(02):325-328
Currently, transcatheter intervention has emerged as a first-line treatment for coarctation of the aortic. Due to the radiation exposure associated with catheter interventional therapy, there are numerous restrictions, which harms both patients and medical personnel and is dependent on sizable radiation apparatus. Here, we report for the first time a case of echo-guiding percutaneous aortic stent implantation for a 27 years female patient of reproductive age. After discharge, the patient's aortic coarctation pressure decreased to 18 mm Hg, and the surgical results were satisfactory.
10.Clinical efficacy of percutaneous balloon mitral valvuloplasty under echocardiographic guidance for moderate to severe mitral stenosis during pregnancy
Peijian WEI ; Wenchao LI ; Hang LI ; Fang FANG ; Fengwen ZHANG ; Wenbin OUYANG ; Shiguo LI ; Deyuan ZHANG ; Yixian LIN ; Xiangbin PAN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2024;31(09):1333-1337
Objective To investigate the effect of percutaneous balloon mitral valvuloplasty under echocardiographic guidance for patients with moderate to severe mitral stenosis during pregnancy. Methods A retrospective observational study was conducted to include pregnant women who were diagnosed with moderate to severe mitral stenosis and underwent percutaneous balloon mitral valvuloplasty under echocardiographic guidance in Fuwai Hospital from August 2018 to June 2022, and their baseline characteristics, surgical outcomes, echocardiographic results, and follow-up results were analyzed. Results A total of 3 pregnant women aged 30-35 years, with gestational age of 19-26 weeks, and New York Heart Association (NYHA) function class Ⅲ were included. All the procedures were successfully performed. The mitral valve orifice area increased from 0.9 cm2 preoperatively to 2.1 cm2 postoperatively. The mean transvalvular pressure gradient decreased from 15.0 mm Hg preoperatively to 6.7 mm Hg postoperatively. No perioperative adverse events occurred. The follow-up time ranged from 3 to 48 months. All patients delivered uneventfully and returned to normal life, with maternal-fetal safety. Conclusion Percutaneous balloon mitral valvuloplasty under echocardiographic guidance is a feasible and effective procedure for the treatment of patients with moderate to severe mitral stenosis in pregnancy, with satisfactory maternal-fetal outcomes.

Result Analysis
Print
Save
E-mail