1.Optimization of extraction process for Shenxiong Huanglian Jiedu Granules based on AHP-CRITIC hybrid weighting method, grey correlation analysis, and BP-ANN.
Zi-An LI ; De-Wen LIU ; Xin-Jian LI ; Bing-Yu WU ; Qun LAN ; Meng-Jia GUO ; Jia-Hui SUN ; Nan-Yang LIU ; Hui PEI ; Hao LI ; Hong YI ; Jin-Yu WANG ; Liang-Mian CHEN
China Journal of Chinese Materia Medica 2025;50(10):2674-2683
By employing the analytic hierarchy process(AHP), the CRITIC method(a weight determination method based on indicator correlations), and the AHP-CRITIC hybrid weighting method, the weight coefficients of evaluation indicators were determined, followed by a comprehensive score comparison. The grey correlation analysis was then performed to analyze the results calculated using the hybrid weighting method. Subsequently, a backpropagation-artificial neural network(BP-ANN) model was constructed to predict the extraction process parameters and optimize the extraction process for Shenxiong Huanglian Jiedu Granules(SHJG). In the extraction process, an L_9(3~4) orthogonal experiment was designed to optimize three factors at three levels, including extraction frequency, water addition amount, and extraction time. The evaluation indicators included geniposide, berberine, ginsenoside Rg_1 + Re, ginsenoside Rb_1, ferulic acid, and extract yield. Finally, the optimal extraction results obtained by the orthogonal experiment, grey correlation analysis, and BP-ANN method were compared, and validation experiments were conducted. The results showed that the optimal extraction process involved two rounds of aqueous extraction, each lasting one hour; the first extraction used ten times the amount of added water, while the second extraction used eight times the amount. In the validation experiments, the average content of each indicator component was higher than the average content obtained in the orthogonal experiment, with a higher comprehensive score. The optimized extraction process parameters were reliable and stable, making them suitable for subsequent preparation process research.
Drugs, Chinese Herbal/analysis*
;
Neural Networks, Computer
2.Fangxia Dihuang Formula regulates PERK/eIF2α axis-mediated microglial polarization in treatment of breast cancer complicated by depression.
Hong-Qiao FAN ; Ying-Yi FAN ; Xiao-Hua PEI
China Journal of Chinese Materia Medica 2025;50(14):4015-4025
Study on the mechanism of Fangxia Dihuang Formula(FXDH) in treating breast cancer complicated with depression through the regulation of M1/M2 microglial polarization via the PERK/eIF2α axis. In addition to control group and 4T1 group, a mouse model of breast cancer complicated with depression was established using 4T1 cells combined with corticosterone. The mice were divided into model group, PERK/eIF2α signaling axis agonist(CCT020312, 2 mg·kg~(-1)·d~(-1)) group, CCT020312(2 mg·kg~(-1)·d~(-1)) + FXDH(13.65 g·kg~(-1)·d~(-1)) group, FXDH(13.65 g·kg~(-1)·d~(-1)) group, FXDH(13.65 g·kg~(-1)·d~(-1)) + Capecitabine Tablets(CAP, 390 mg·kg~(-1)·d~(-1)) group, and Fluoxetine Hydrochloride Capsules(FXT, 2.6 mg·kg~(-1)·d~(-1)) + CAP(390 mg·kg~(-1)·d~(-1)) group, with continuous intervention for 21 d. Depression-like behaviors in mice were assessed through sugar preference test and open field test. Hematoxylin-eosin(HE) staining was used to evaluate the morphology of tumor and hippocampal DG region neurons. Nissl staining was employed to detect changes in Nissl bodies in the hippocampal CA3 region. Immunofluorescence was used to observe cluster of differentiation 86(CD86)/ionized calcium-binding adapter molecule 1(Iba-1) and cluster of differentiation 206(CD206)/Iba-1 in hippocampal tissue. Real-time fluorescence quantitative polymerase chain reaction(RT-qPCR) was used to detect the mRNA expression of M1-type microglia [interleukin-6(IL-6), tumor necrosis factor-α(TNF-α)] and M2-type [arginase-1(Arg-1), IL-10] in hippocampal tissue. Western blot was used to detect the protein expression of key factors in the PERK/eIF2α axis, including PERK, eIF2α, activating transcription factor 4(ATF4), and C/EBP homologous protein(CHOP) in hippocampal tissue. The results showed that compared to model group/CCT020312 + FXDH group, FXDH group increased sugar preference index, total movement distance, central zone distance, and central zone entries; reduced tumor mass and volume; tumor cells were sparsely arranged, with a smaller nuclear-to-cytoplasmic ratio and reduced nuclear division figures, increased Nissl body count, and alleviated neuronal nuclear pyknosis; increased CD206-positive M2-type microglia expression, decreased CD86/Iba-1-positive M1-type microglia expression; reduced IL-6 and TNF-α mRNA expression, and increased Arg-1 and IL-10 mRNA expression; downregulated PERK, eIF2α, ATF4, and CHOP protein expression levels. The results indicate that the mechanism of FXDH in treating breast cancer complicated with depression may be related to inhibiting the activity of the PERK/eIF2α axis, reducing the proportion of M1-type microglia, increasing the proportion of M2-type microglia, thereby suppressing neuronal immune inflammation, improving depressive symptoms, and subsequently delaying the progression of breast cancer.
Animals
;
Drugs, Chinese Herbal/administration & dosage*
;
Female
;
Microglia/cytology*
;
Mice
;
Depression/complications*
;
eIF-2 Kinase/genetics*
;
Humans
;
Breast Neoplasms/psychology*
;
Eukaryotic Initiation Factor-2/genetics*
;
Mice, Inbred BALB C
;
Signal Transduction/drug effects*
;
Cell Line, Tumor
3.Regulatory effects of Dangua Humai Oral Liquid on gut microbiota and mucosal barrier in mice with glucolipid metabolism disorder.
Zhuang HAN ; Lin-Xi JIN ; Zhi-Ta WANG ; Liu-Qing YANG ; Liang LI ; Yi RUAN ; Qi-Wei CHEN ; Shu-Hong YAO ; Xian-Pei HENG
China Journal of Chinese Materia Medica 2025;50(15):4315-4324
The gut microbiota regulates intestinal nutrient absorption, participates in modulating host glucolipid metabolism, and contributes to ameliorating glucolipid metabolism disorder. Dysbiosis of the gut microbiota can compromise the integrity of the intestinal mucosal barrier, induce inflammatory responses, and exacerbate insulin resistance and abnormal lipid metabolism in the host. Dangua Humai Oral Liquid, a hospital-developed formulation for regulating glucolipid metabolism, has been granted a national invention patent and demonstrates significant clinical efficacy. This study aimed to investigate the effects of Dangua Humai Oral Liquid on gut microbiota and the intestinal mucosal barrier in a mouse model with glucolipid metabolism disorder. A glucolipid metabolism disorder model was established by feeding mice a high-glucose and high-fat diet. The mice were divided into a normal group, a model group, and a treatment group, with eight mice in each group. The treatment group received a daily gavage of Dangua Humai Oral Liquid(20 g·kg~(-1)), while the normal group and model group were given an equivalent volume of sterile water. After 15 weeks of intervention, glucolipid metabolism, intestinal mucosal barrier function, and inflammatory responses were evaluated. Metagenomics and untargeted metabolomics were employed to analyze changes in gut microbiota and associated metabolic pathways. Significant differences were observed between the indicators of the normal group and the model group. Compared with the model group, the treatment group exhibited marked improvements in glucolipid metabolism disorder, alleviated pathological damage in the liver and small intestine tissue, elevated expression of recombinant claudin 1(CLDN1), occluding(OCLN), and zonula occludens 1(ZO-1) in the small intestine tissue, and reduced serum levels of inflammatory factors lipopolysaccharides(LPS), lipopolysaccharide-binding protein(LBP), interleukin-6(IL-6), and tumor necrosis factor-α(TNF-α). At the phylum level, the relative abundance of Bacteroidota decreased, while that of Firmicutes increased. Lipid-related metabolic pathways were significantly altered. In conclusion, based on the successful establishment of the mouse model of glucolipid metabolism disorder, this study confirmed that Dangua Humai Oral Liquid effectively modulates gut microbiota and mucosal barrier function, reduces serum inflammatory factor levels, and regulates lipid-related metabolic pathways, thereby ameliorating glucolipid metabolism disorder.
Animals
;
Gastrointestinal Microbiome/drug effects*
;
Mice
;
Intestinal Mucosa/microbiology*
;
Male
;
Drugs, Chinese Herbal/administration & dosage*
;
Mice, Inbred C57BL
;
Humans
;
Glycolipids/metabolism*
;
Lipid Metabolism/drug effects*
;
Administration, Oral
;
Disease Models, Animal
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Effects of honey-processed Astragalus on energy metabolism and polarization of RAW264.7 cells
Hong-chang LI ; Ke PEI ; Wang-yang XIE ; Xiang-long MENG ; Zi-han YU ; Wen-ling LI ; Hao CAI
Acta Pharmaceutica Sinica 2025;60(2):459-470
In this study, RAW264.7 cells were employed to investigate the effects of honey-processed
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
9.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
10.Clinical efficacy of Fu's subcutaneous needling based on "multi-joint muscle spiral balance chain" theory for cervical vertigo and its effect on blood flow velocity of vertebral artery.
Meng GONG ; Zhixiang LIU ; Pei LI ; Renyan XIAO ; Peng JIA ; Hong GUO ; Song JIN
Chinese Acupuncture & Moxibustion 2025;45(1):13-18
OBJECTIVE:
To observe the clinical efficacy of Fu's subcutaneous needling based on "multi-joint muscle spiral balance chain" theory for cervical vertigo (CV) and its effect on blood flow velocity of vertebral artery.
METHODS:
A total of 60 patients with CV were randomized into a Fu's subcutaneous needling group and a medication group, 30 cases in each one. In the Fu's subcutaneous needling group, Fu's subcutaneous needling was delivered at Dazhui (GV14), the flexible tube was retained for 5 min after sweeping manipulation, and the treatment was given once every other day, 3 times a week for 3 weeks. In the medication group, betahistine mesylate tablet and diclofenac sodium dual-release enteric capsule were taken orally for continuous 3 weeks. Before treatment, after treatment, and in follow-up of one month after treatment completion, the scores of dizziness handicap inventory (DHI) and visual analogue scale (VAS) were observed; before and after treatment, the blood flow velocity of vertebral artery was measured by transcranial Doppler, and the clinical efficacy was evaluated after treatment in the two groups.
RESULTS:
After treatment and in follow-up, each item scores and total scores of DHI were decreased compared with those before treatment in the two groups (P<0.05); the VAS scores after treatment in the two groups, as well as the VAS score in follow-up of the Fu's subcutaneous needling group, were decreased compared with those before treatment (P<0.05). In the Fu's subcutaneous needling group, after treatment and in follow-up, the physical scores and the total scores of DHI, and the VAS scores were lower than those in the medication group (P<0.05); in follow-up, the emotional and functional scores of DHI were lower than those in the medication group (P<0.05). After treatment, the mean blood flow velocity (Vm) of the left vertebral artery (LVA) and the right vertebral artery (RVA) was increased compared with that before treatment in the two groups (P<0.05), and the Vm of LVA and RVA in the Fu's subcutaneous needling group was higher than that in the medication group (P<0.05). The total effective rate was 100.0% (30/30) in the Fu's subcutaneous needling group, which was superior to 73.3% (22/30) in the medication group (P<0.05).
CONCLUSION
Fu's subcutaneous needling based on the "multi-joint muscle spiral balance chain" theory can effectively alleviate the vertigo and neck pain, and improve the blood flow velocity of vertebral artery in CV patients, and has a long-term therapeutic effect.
Humans
;
Female
;
Male
;
Middle Aged
;
Acupuncture Therapy/instrumentation*
;
Vertebral Artery/physiopathology*
;
Adult
;
Vertigo/physiopathology*
;
Aged
;
Blood Flow Velocity
;
Treatment Outcome
;
Acupuncture Points
;
Young Adult

Result Analysis
Print
Save
E-mail