1.Current status and influencing factors of knowledge-attitude-practice in myopia prevention and control among children and adolescents in Ningbo
Jue WANG ; Xiaotian LIU ; Xia JIN ; Yanli ZHANG ; Hongjun LI ; Honger SUN ; Aiai CHEN ; Yuan TANG
International Eye Science 2026;26(3):518-522
AIM:To investigate the current status and influencing factors of knowledge-attitude-practice in myopia prevention and control among children and adolescents in Ningbo City, thereby providing a scientific basis for formulating targeted prevention strategies.METHODS: Children and adolescents aged 6-12 years old were selected from the medical-school collaborative myopia prevention network in Ningbo City between August 2024 and May 2025 using stratified cluster sampling. Information on myopia prevention knowledge(15 items)and practice(9 items)was collected through questionnaire surveys. Logistic regression models were used to analyze factors influencing myopia occurrence in children and adolescents.RESULTS: A total of 664 children and adolescents aged 6-12 years were enrolled in this study. Participants were divided by age into three groups: 6-7 years old(n=221), 8-9 years old(n=221), and 10-12 years old(n=222). Of the 664 questionnaires distributed, 637 valid questionnaires were returned(201 from the 6-7 age group, 235 from the 8-9 age group, and 201 from the 10-12 age group), yielding an effective response rate of 95.9%. Based on myopia screening results, the non-myopic group comprised 203 participants(31.9%), including 100 males and 103 females, with a mean age of 8.82±1.98 years old. The myopic group comprised 434 participants(68.1%), including 213 males and 221 females, with a mean age of 9.10±1.95 years old. The myopia prevalence rates in the 6-7, 8-9, and 10-12 age groups were 37.8%(76/201), 71.9%(169/235), and 94.0%(189/201), respectively(P<0.001). Regarding the knowledge and practice of myopia prevention, the overall awareness rate in the non-myopic group(59.7%±9.7%)was significantly higher than that in the myopic group(48.7%±8.5%; P<0.001). Additionally, the non-myopic group scored higher on the key practice of “regular eye examinations”(4.27±0.96)compared to the myopic group(4.10±1.05; P<0.05). Logistic regression analysis indicated that age was the primary risk factor for myopia occurrence.CONCLUSION: Age is the dominant factor in the onset of myopia, and there is a phenomenon of “knowledge-practice gap”; the traditional health education model has limitations, and a precise prevention and control system based on developmental patterns should be established.
3.Treatment of irreducible intertrochanteric femoral fractures in elderly by novel bone hook combined with finger-guided technique.
Zenghui ZHANG ; Tichao HAN ; Wei LI ; Yangyang ZHOU ; Junjun LIU ; Nannan LI ; Tiantian REN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(1):53-58
OBJECTIVE:
To investigate the feasibility and effectiveness of the novel bone hook combined with finger-guided technique in the treatment of irreducible intertrochanteric femoral fractures in elderly.
METHODS:
Between January 2021 and August 2023, 23 elderly patients with irreducible intertrochanteric femoral fractures were treated with the novel bone hook combined with finger-guided technique. There were 10 males and 13 females; the age ranged from 68 to 93 years (mean, 76.2 years). The time from injury to operation ranged from 36 to 76 hours (mean, 51.2 hours). According to the classification standard proposed by TONG Dake et alin 2021, there were 10 cases of typeⅠA, 1 case of typeⅠB, 6 cases of type ⅡA, 4 cases of type ⅡB, and 2 cases of type ⅡC. The operation time, intraoperative blood loss, intraoperative fluoroscopy frequences, and quality of fracture reduction were recorded. The fracture healing time and occurrence of postoperative complications were observed during follow-up. At last follow-up, the Harris scoring system was used to evaluate the hip joint function.
RESULTS:
The operation time was 42-95 minutes (mean, 52.1 minutes). The intraoperative blood loss was 40-420 mL (mean, 126.5 mL). Intraoperative fluoroscopy was performed 14-34 times (mean, 20.7 times). According to the criteria proposed by Chang et al, the quality of fracture reduction was rated as good in 20 cases and acceptable in 3 cases. All patients were followed up 6-20 months (mean, 10.2 months). X-ray film showed that all fractures healed with the healing time of 3.0-5.5 months (mean, 4.0 months). At last follow-up, the Harris score of the hip joint ranged from 82 to 97 points (mean, 90.4 points). Among them, 14 cases were rated as excellent and 9 cases as good. No complication such as coxa vara, cutting of the cephalomedullary nail, nail withdrawal, or nail breakage occurred during follow-up.
CONCLUSION
The treatment of elderly patients with irreducible intertrochanteric femoral fractures by using the novel bone hook combined with finger-guided technique can achieve high-quality fracture reduction and fixation, and has a good effectiveness.
Humans
;
Male
;
Female
;
Aged
;
Aged, 80 and over
;
Hip Fractures/diagnostic imaging*
;
Fracture Fixation, Internal/instrumentation*
;
Fracture Healing
;
Treatment Outcome
;
Operative Time
;
Fracture Fixation, Intramedullary/instrumentation*
;
Bone Nails
;
Postoperative Complications/epidemiology*
;
Feasibility Studies
;
Fingers
4.A comparative study of color Doppler ultrasound and CT angiography for preoperative evaluation of perforator vessels in free posterior interosseous artery flap.
Hongquan WANG ; Shanshan LIU ; Yingzhi XIE ; Haoliang HU ; Miaozhong LI
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(4):483-487
OBJECTIVE:
To investigate the accuracy of color Doppler ultrasound (CDU) and CT angiography (CTA) in the preoperative evaluation of perforator vessels in free posterior interosseous artery perforator (PIAP) flaps.
METHODS:
Between January 2020 and December 2023, 19 patients with hand skin and soft tissue defects caused by trauma were admitted. There were 11 males and 8 females, with a median age of 45 years (range, 26-54 years). The interval between injury and admission was 5-11 days (mean, 7.2 days). The skin and soft tissue defects were located on the dorsum of the hand in 8 cases and on the fingers in 11 cases. The size of defect ranged from 4.0 cm×2.5 cm to 7.5 cm×3.5 cm. After locating the perforator vessels through CDU and CTA before operation, the free PIAP flaps were designed to repair hand defects, with the size of 4.5 cm×3.0 cm-7.5 cm×4.0 cm. The defects of donor sites were directly sutured. The number and diameter of perforator vessels in the posterior interosseous artery detected by CDU and CTA were compared. The differences in localization of perforator vessels using CDU and CTA and their clinical effects were also compared to calculate the accuracy and recognition rate. During follow-up, the survival of the skin flap was observed, and the Vancouver scar scale (VSS) score was used to evaluate the healing of the donor site, while the visual analogue scale (VAS) score was used to evaluate the patient's satisfaction with the appearance of the skin flap.
RESULTS:
The number and the diameter of PIAP vessels was 5.8±1.2 and (0.62±0.08) mm assessed by CDU and 5.2±1.0 and (0.60±0.07) mm by CTA, showing no significant difference between the two methods ( P>0.05). The number, course, and distribution of perforator vessels of the PIAP vessels observed during operation were basically consistent with those detected by preoperative CDU and CTA. Compared with intraoperative observation results, the recognition rates of dominant perforating vessels by CDU and CTA were 95.0% (18/19) and 89.5% (17/19), respectively, and the accuracy rates were 100% (19/19) and 84.2% (16/19), with no significant difference between the two methods ( P>0.05). All flaps survived after operation, and all wounds and incisions at donor sites healed by first intention. All patients were followed up 6-13 months (mean, 8.2 months). At last follow-up, the skin flaps had elasticity and soft texture,with the patient satisfaction VAS score of 9.2±0.8. The donor sites had no obvious scar hyperplasia with the VSS score of 11.7±0.9.
CONCLUSION
CDU and CTA accurately identify the dominant perforator vessels and provide reliable information for vessel localization, facilitating precise flap harvesting and minimizing donor site injury. However, CDU offers superior visualization of distal end of perforator vessels in the forearm compared to CTA.
Humans
;
Female
;
Male
;
Adult
;
Perforator Flap/blood supply*
;
Middle Aged
;
Ultrasonography, Doppler, Color/methods*
;
Computed Tomography Angiography/methods*
;
Soft Tissue Injuries/diagnostic imaging*
;
Hand Injuries/diagnostic imaging*
;
Plastic Surgery Procedures/methods*
;
Hand/surgery*
;
Preoperative Care
;
Arteries/diagnostic imaging*
5.Functional perforator flap: concept and clinical applications.
Hu JIAO ; Mengqing ZANG ; Lu ZHOU ; Shengyang JIN ; Jiadong PAN ; Miao WANG ; Xin WANG ; Yuanbo LIU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(9):1076-1085
OBJECTIVE:
To review the clinical applications of functional perforator flaps in restoring human body functions.
METHODS:
An extensive literature review was conducted on both domestic and international publications to summarize the clinical use of functional perforator flaps for functional restoration.
RESULTS:
Perforator flaps are among the most commonly used flaps in reconstructive surgery. Beyond providing soft tissue repair, they are increasingly employed to reconstruct diverse bodily functions, leading us to propose the concept of the "functional perforator flap". Although various forms of functional perforator flaps are currently utilized, reports are predominantly scattered case studies, lacking systematic organization. Commonly used functional perforator flaps can be categorized into five types: chimeric perforator flaps, perforator flaps for nerve function restoration, perforator flaps for lymphatic drainage enhancement, flow-through perforator flaps, and perforator flaps for restoring bone and joint motion. These flaps significantly broaden the application scope of perforator flaps, elevating the goal of reconstruction from mere wound repair to achieving repair concurrent with functional reconstruction.
CONCLUSION
The application of various functional perforator flap designs significantly improves wound reconstruction outcomes and represents an effective approach for managing complex defects. Future developments will undoubtedly see more forms of functional perforator flaps reported to meet increasingly sophisticated reconstructive demands.
Humans
;
Perforator Flap/blood supply*
;
Plastic Surgery Procedures/methods*
;
Soft Tissue Injuries/surgery*
;
Skin Transplantation/methods*
;
Wound Healing
6.Clinical observation of free rectus femoris flap for repair of surgical defect in pharyngo-laryngeal malignant tumor.
Wen LI ; Zhe CHEN ; Jiayan WANG ; Xiaojiao LAN ; Zila PURA ; Xiaoxing XIONG ; Liu YANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(11):1452-1458
OBJECTIVE:
To explore the feasibility and effectiveness of repairing surgical defect in pharyngo-laryngeal malignant tumor with free rectus femoris flap.
METHODS:
The clinical data of 34 patients with surgical defects in pharyngo-laryngeal malignant tumor who met the selection criteria between July 2014 and August 2024 were retrospectively analyzed. There were 25 males and 9 females, aged 25-82 years, with a median age of 54 years. The disease duration ranged from 2 months to 2 years, with a median of 7 months. The tumor locations included the oropharynx, hypopharynx, cervical esophagus, and larynx. Pathological types included squamous cell carcinoma (29 cases), myoepithelial carcinoma (2 cases), adenoid cystic carcinoma (1 case), and diffuse large B-cell lymphoma (2 cases). TNM staging: 16 cases of T 4N 1M 0, 3 cases of T 4N 2M 0, 3 cases of T 4N 0M 0, 10 cases of T 3N 1M 0, and 2 cases of T 3N 0M 0. The 2017 American Joint Committee on Cancer (AJCC) staging was stage Ⅲ in 2 cases and stage Ⅳ in 32 cases. The blood supply of the proximal rectus femoris muscle was observed by enhanced CT of the lower limb vessels before operation, and the surgical defects ranged from 3.0 cm×2.0 cm to 12.0 cm×8.5 cm. The blood supply and perforators of rectus femoris muscle were explored during operation, and the free rectus femoris flap pedicled with the direct vascular stem of rectus femoris muscle was used to repair the defect. For the patients with pharyngeal fistula or obvious neck swelling after operation, the blood supply of the flap was analyzed by vascular enhanced CT to determine the corresponding strategies of nutritional support, anti-infection, dressing change and drainage. Radiotherapy and chemotherapy were supplemented in 27 patients with lymph node metastasis after operation.
RESULTS:
All the 34 patients were followed up 1-10 years, with an average of 3 years. The flap was found to be necrotic by fibrolaryngoscopy at 1 week after operation in 2 cases, and the incision healed after dressing change and nutritional support, and no reoperation was performed. The flap was in good condition at 1 week after operation in 4 cases, and the signs of gradual necrosis of the flap were found within 1 month after operation, of which 2 cases were healed after dressing change, 1 case was removed the necrotic tissue by reoperation, and 1 case was healed after pectoralis major myocutaneous flap was used to repair the pharyngeal tissue defect. The flaps survived in 28 cases, including 4 cases of pharyngeal fistula, which healed by dressing change. Twenty-two cases achieved satisfactory results in swallowing or phonation. Two patients with total laryngectomy and voice reconstruction underwent reoperation to seal the voice tube because of postoperative aspiration. During the follow-up, 1 case had tracheal stomal recurrence, 2 cases had bone metastasis, and 1 case had bone and lung metastasis.
CONCLUSION
The free rectus femoris flap has good flexibility, the volume of the flap is easy to adjust, and the incision of the donor site is concealed, which is expected to become a new choice for the repair of the surgical defect in pharyngo-laryngeal malignant tumor.
Humans
;
Male
;
Middle Aged
;
Female
;
Aged
;
Adult
;
Plastic Surgery Procedures/methods*
;
Retrospective Studies
;
Laryngeal Neoplasms/pathology*
;
Aged, 80 and over
;
Pharyngeal Neoplasms/pathology*
;
Free Tissue Flaps/blood supply*
;
Quadriceps Muscle/transplantation*
;
Surgical Wound/surgery*
;
Treatment Outcome
7.A finite element biomechanical study of anterior transpedicular root screw plate fixation system in the lower cervical spine.
Xiao-Ping XU ; Zhi-Peng HOU ; Liu-Jun ZHAO
China Journal of Orthopaedics and Traumatology 2025;38(8):848-855
OBJECTIVE:
To establish a two-segment vertebrectomy model using the finite element method, and to measure and compare the biomechanical properties of the lower cervical anterior transpedicular root screw (ATPRS) plate system, lower cervical anterior pedicle screw (ATPS) plate system, and lower cervical anterior cervical locked-plate (ACLP) system on this model.
METHODS:
CT data of the cervical spine (C0-T1) from a 34-year-old healthy adult male volunteer were collected. A nonlinear complete model of the lower cervical spine (C3-C7) was established using Mimics 10.01 software, based on which the ATPRS fixation model, ATPS fixation model, and ACLP fixation model were constructed respectively. An axial pressure of 75 N and a pure couple moment of 1.5 N·m were applied to C3 to make the model perform flexion-extension, left-right lateral bending, and left-right rotation movements. The range of motion (ROM) and stress distribution of each model under different working conditions were compared.
RESULTS:
The ROM of the C4-C7 segments in the ACLP group, ATPS group, and ATPRS group was reduced to 0.65° (-95.2%), 0.58° (-95.7%), and 0.62° (-95.4%) respectively compared with the intact model during flexion-extension movement;during lateral bending movement, it was reduced to 0.58° (-95.2%), 0.51°(-95.8%), and 0.60° (-95.1%) respectively;during rotation movement, it was reduced to 1.17° (-89.6%), 1.26° (-88.8%), and 1.27°(-88.7%) respectively. In terms of the stress on the titanium mesh graft, the ATPS group and ATPRS group had the maximum load during extension and the minimum load during flexion. Compared with the ACLP group, the stress on the titanium mesh graft in ATPS and ATPRS decreased by (-33.7%) and (-15.8%) in flexion, (-29.4%) and (-13.2%) in extension, (-26.2%) and (-23.4%) in lateral bending, and (-18.8%) and (-5.4%) in rotation, respectively. In terms of bone-screw interface stress, the peak bone stress near the C7 screw in the ACLP group, ATPS group, and ATPRS group increased by 49.2%, 45.0%, and 47.6% respectively compared with the peak bone stress near the C4 screw during extension. However, during flexion and lateral bending, there was no significant difference in the peak bone stress near the C4 and C7 screws. During rotation, the difference between the peak bone stress near the C4 screw and that near the C7 screw showed that in the ACLP group, left rotation (37.6%) was similar to right rotation (36.7%), while in the ATPS group and ATPRS group, left rotation was lower than right rotation.
CONCLUSION
Compared with the ACLP group, the ATPS group and ATPRS group have greater fixation stiffness and more stable fixation. However, in rotational movement, due to the uneven distribution of fixation stiffness, the stress distribution during torsion is uneven, but it is still better than the ACLP group. This indicates that ATPRS, like ATPS, has good primary stability, providing favorable conditions for bone graft fusion.
Humans
;
Finite Element Analysis
;
Male
;
Cervical Vertebrae/physiopathology*
;
Adult
;
Biomechanical Phenomena
;
Bone Plates
;
Bone Screws
;
Range of Motion, Articular
;
Fracture Fixation, Internal
8.A finite element method biomechanical study of a new type of composite anterior cervical internal fixation methods.
Zhi-Peng HOU ; Sen-Qi YE ; Ji-Hui ZHANG ; Liu-Jun ZHAO ; Yong-Jie GU ; Liang YU
China Journal of Orthopaedics and Traumatology 2025;38(11):1156-1163
OBJECTIVE:
To compare the biomechanical properties of four internal fixation methods in a lower cervical spine injury model using the finite element method.
METHODS:
Cervical CT data of a 28-year-old healthy adult male were utilized to establish a finite element model of the normal cervical spine and a lower cervical spine three-column injury model. Four internal fixation methods were then applied to the three-column injury model, resulting in four groups:Group A, anterior cervical locked-plate(ACLP) fixation system model(anterior approach);Group B, posterior cervical pedicle screw fixation model (posterior approach);Group C, combined anterior and posterior cervical pedicle screw fixation model; Group D, Novel composite anterior cervical internal fixation model. A 75 N axial compressive load and a 1.0 N·m pure moment were applied to the upper surface of the cervical spine model to simulate flexion, extension, rotation, and lateral bending movements. The intervertebral range of motion(ROM) and stress distribution of the internal fixators under different motion conditions were compared across all models.
RESULTS:
Compared with the normal model, the reductions in overall intervertebral ROM for each group under flexion, extension, rotation, and lateral bending were as follows:Group A, 24.04°, 23.12°, 6.24°, and 9.06°;Group B, 24.42°, 24.34°, 6.48°, and 9.20°;Group C, 25.43°, 25.29°, 7.17°, and 9.57°;Group D, 24.75°, 25.5°, 6.71°, and 9.12°. The peak stress values of the internal fixators in each group were:Group A, 53.9 MPa, 79.9 MPa, 61.4 MPa, and 80.3 MPa;Group B, 218.3 MPa, 105.4 MPa, 206.6 MPa, and 186.8 MPa;Group C, 40.8 MPa, 97.2 MPa, 47.1 MPa, and 39.4 MPa;Group D, 93.0 MPa, 144.0 MPa, 64.8 MPa, and 106.3 MPa.
CONCLUSION
The biomechanical properties of the novel composite anterior cervical internal fixation method are similar to those of the combined anterior-posterior fixation method, and superior to both the anterior cervical ACLP plate-screw fixation and posterior cervical pedicle screw fixation methods.
Humans
;
Finite Element Analysis
;
Cervical Vertebrae/physiopathology*
;
Male
;
Biomechanical Phenomena
;
Adult
;
Fracture Fixation, Internal/methods*
;
Range of Motion, Articular
9.Application of the distraction support in intramedullary nailing treatment for tibial shaft fracture.
Liwei YAO ; Haijiao MAO ; Wenwei DONG ; Zeting WU ; Qing LIU
Chinese Journal of Traumatology 2025;28(2):113-117
PURPOSE:
This study aims to investigate the efficacy of novel distraction support (DS) in intramedullary nailing treatment for tibial shaft fracture.
METHODS:
The random controlled trial included adult patients with tibial shaft fractures who were treated with intramedullary nailing at the trauma center between July 2013 and December 2018. Participants were randomly assigned to either control group (n=43) or DS group (n=42) based on whether DS was used during the operation. All surgical procedures were conducted by a single, experienced surgeon. Parameters such as hospital stay, blood loss, operative time, infection, delayed union, and malalignment were recorded for assessment. Shapiro-Wilk test was used to assess normality, and the F test was adopted to measure variance homogeneity. Continuous variables were presented as mean±standard deviation and compared via independent samples t-tests. Categorical variables are expressed as percentages. The Pearson's Chi-squared or Fisher's exact test was used for categorical variables n (%). Two-sided p<0.05 indicated statistical significance.
RESULTS:
A total of 85 participants were enrolled in the study. All cases achieved acceptable reduction. The operative time was significantly shorter in the DS group than in control group ((75.3±10.5) min vs. (90.4±15.5) min, p<0.001). Additionally, the DS group showed lesser blood loss ((60.1±27.2) mL vs. (85.4±25.4) mL, p<0.001). No significant differences were observed between the 2 groups in terms of hospital stay ((9.4±2.7) days vs. (10.2±3.1) days, p=0.370), infection (3 (7.1%) vs. 2 (4.7%), p=0.978), delayed union (2 (4.8%) vs. 5 (11.6%), p=0.450), and malalignment (3 (7.1%) vs. 5 (11.6%), p=0.713).
CONCLUSION
The use of DS in intramedullary nailing surgery is effective. The application of this DS system may represent a valuable addition to future clinical practice.
Humans
;
Fracture Fixation, Intramedullary/methods*
;
Tibial Fractures/surgery*
;
Male
;
Female
;
Adult
;
Middle Aged
;
Operative Time
;
Length of Stay
;
Young Adult
;
Osteogenesis, Distraction/methods*
10.Hemolytic disease of the fetus and newborn caused by Rh system anti-c antibodies: a case report and literature review
Luyan CHEN ; Dong XIANG ; Dingfeng LYU ; Zhenyun LIU ; Xinyi ZHU ; Shuan TAO ; Qiming YING ; Wei LIANG
Chinese Journal of Blood Transfusion 2025;38(6):843-848
Objective: To summarize the laboratory findings of a case of hemolytic disease of the fetus and newborn (HDFN) caused by Rh system anti-c antibodies and to review the literature, so as to explore the characteristics of anti-c HDFN. Methods: The ABO blood type, Rh blood type, direct antiglobulin test (DAT) results, and the presence of unexpected antibodies and their titers were determined by serological methods. The cases of anti-c HDFN in our laboratory in China and abroad were statistically analyzed, and the incidence of severe HDFN caused by anti-c, anti-D and anti-E was compared. Results: The blood type of the child was B (Rh CcDee) with a positive DAT. Anti-c antibody was detected in both serum and eluate, with a serum antibody titer of 4. The mother’s blood type was AB (Rh CCDee) with a negative DAT, and anti-c antibody was detected in the serum with a titer of 128. Among 20 cases of anti-c HDFN, 17 were DAT positive, and 9 (45%, 9/20) underwent blood transfusion or exchange transfusion. The incidence of severe HDFN was 47.60% (10/21) for anti-c, 47.60% (10/21) for anti-D and 31.30% (5/16) for anti-E. Conclusion: Maternal pregnancy and/or blood transfusion are the main reasons for the production of Rh alloantibodies such as anti-c. The prevention and management of anti-c should be similar to that of anti-D. Rh antigen-matched (five antigens of Rh blood group) transfusion is necessary for women of childbearing age to avoid antibody production, and Rh typing and antibody screening during prenatal examination is recommended to ensure early detection, intervention and treatment.

Result Analysis
Print
Save
E-mail