1.Development and application of an auxiliary device based on embedded microcontroller system for venipuncture
Jing YANG ; Jun JI ; Xiujun CHEN ; Zhihan SHANG ; Wenhui ZHAI ; Ning WANG ; Xiao ZHANG ; Rong ZHANG
China Medical Equipment 2025;22(10):159-162
Objective:To design an auxiliary device based on embedded microcontroller system for venipuncture,which can adjust posture,so as to resolve the problem that occurs failure in puncture due to insufficient exposure of the puncture site in various scenarios.Methods:The device consisted of a support component,an air ring,a component with lifting and angle adjustment,and a pedestal.By advanced embedded microcontroller technique,it can precisely regulate the posture of the support structure of patient's limbs,and fully expose the targeted puncture site,and create more favorable conditions for nurses in performing punctures.A total of 2,482 patients who underwent blood collection at emergency department of the 305th Hospital of the People's Liberation Army from September to October 2024 were selected.The 1,204 patients were enrolled in September were divided into control group(without using the auxiliary device for venipuncture),and the 1,278 patients were enrolled in October were divided into observation group(using the auxiliary device for venipuncture).The puncture's one-time success rates of junior nurses(experience≤3 years)for both groups were compared.Each group respectively selected 150 patients by using the random number table method to conduct investigate,and satisfaction scores for success rate of puncture,and comfort degree of puncture for position,as well as the pain,process and efficiency,were investigated Results:The puncture's one-time success rates of junior nurses for the patients of control and observation groups were respectively 85.05%and 89.36%,with a statistically significant difference(x2=10.35,P<0.05).The satisfaction scores of patients in the observation group were significantly higher than those in the control group,with a statistically significant difference(t=-5.529,P<0.05).Conclusion:This device is simple and convenient in operation,and has favorable stability.It is beneficial to adjust position and exposure puncture site for patients who undergo peripheral venipuncture.It can improve puncture's success rate and patients'satisfaction.
2.An investigation of diagnostic X-ray resources in Jinan in 2023
Guoying NING ; Yujiang GU ; Aihua ZHAI ; Jiangbo XIN ; Yiwen QIN
Chinese Journal of Radiological Medicine and Protection 2025;45(4):341-345
Objective:To investigate the current status of diagnostic X-ray resources in Jinan in order to provide theoretical basis for continuously optimizing the allocation of diagnostic resources and strengthening the management of radiological health and radiation protection.Methods:In accordance with the 2023 Jinan radiation protection monitoring program of medical and health institutions, a survey was carried out for medical institutions involved in diagnostic X-ray examinations (excluding military hospitals and dental clinics) in Jinan by using uniform questionnaires. The survey included the basic situation of diagnostic X-ray institutions, the allocation of diagnostic X-ray equipment, the number of diagnostic staff, and the frequency of diagnositic X-ray examinations.Results:In 2023, there were 298 diagnostic X-ray institutions in Jinan, with 3 494 diagnostic workers and 1 387 items of diagnostic X-ray equipment. The included were 41 tertiary hospitals, 57 secondary hospitals, 110 primary hospitals and 90 unrated hospitals. The tertiary hospitals possessed the largest number of the diagnostic workers and equipment, accounting for 60.99% and 45.35% of the total, respectively. Among all the items of diagnostic X-ray equipment, the number of items of digital radiography equipment ranked top (34.37%), followed by CT machines (24.44%). There were 147.32 items of diagnostic X-ray equipment per million population on average. A total of 8 180 363 individuals received various types of diagnostic X-ray examinations, with CT diagnosis accounting for 46.93% and X-ray for 34.41%. The frequency of diagnostic X-ray examinations was 868.86/1 000 population, including the frequency of CT examinations of 407.76 per 1 000 population.Conclusions:The per capita possession of medical X-ray equipment in Jinan is at a high level. The frequency of medical exposure has increased significantly, especially CT examinations. There is a big gap in diagnostic X-ray resource allocation between different levels of hospitals, so it is necessary to control the resource allocation and strengthen the protection of CT examination on the scientific basis.
3.Development and application of an auxiliary device based on embedded microcontroller system for venipuncture
Jing YANG ; Jun JI ; Xiujun CHEN ; Zhihan SHANG ; Wenhui ZHAI ; Ning WANG ; Xiao ZHANG ; Rong ZHANG
China Medical Equipment 2025;22(10):159-162
Objective:To design an auxiliary device based on embedded microcontroller system for venipuncture,which can adjust posture,so as to resolve the problem that occurs failure in puncture due to insufficient exposure of the puncture site in various scenarios.Methods:The device consisted of a support component,an air ring,a component with lifting and angle adjustment,and a pedestal.By advanced embedded microcontroller technique,it can precisely regulate the posture of the support structure of patient's limbs,and fully expose the targeted puncture site,and create more favorable conditions for nurses in performing punctures.A total of 2,482 patients who underwent blood collection at emergency department of the 305th Hospital of the People's Liberation Army from September to October 2024 were selected.The 1,204 patients were enrolled in September were divided into control group(without using the auxiliary device for venipuncture),and the 1,278 patients were enrolled in October were divided into observation group(using the auxiliary device for venipuncture).The puncture's one-time success rates of junior nurses(experience≤3 years)for both groups were compared.Each group respectively selected 150 patients by using the random number table method to conduct investigate,and satisfaction scores for success rate of puncture,and comfort degree of puncture for position,as well as the pain,process and efficiency,were investigated Results:The puncture's one-time success rates of junior nurses for the patients of control and observation groups were respectively 85.05%and 89.36%,with a statistically significant difference(x2=10.35,P<0.05).The satisfaction scores of patients in the observation group were significantly higher than those in the control group,with a statistically significant difference(t=-5.529,P<0.05).Conclusion:This device is simple and convenient in operation,and has favorable stability.It is beneficial to adjust position and exposure puncture site for patients who undergo peripheral venipuncture.It can improve puncture's success rate and patients'satisfaction.
4.Intravoxel Incoherent Motion Quantitative Parameters Combined with Pathological Grading for Assessing the Survival Prognosis of Hepatocellular Carcinoma
Xuelian SHI ; Yingmin ZHAI ; Hui LIU ; Jiangyang PAN ; Ning ZHANG ; Gaofeng SHI
Chinese Journal of Medical Imaging 2025;33(3):260-266
Purpose To explore the predictive value of intravoxel incoherent motion quantitative parameters and pathological grading for the survival prognosis of patients with hepatocellular carcinoma(HCC)after surgery.Materials and Methods A retrospective analysis was performed on 65 patients with HCC who had complete imaging data and underwent radical surgery at the Fourth Hospital of Hebei Medical University from October 2018 to November 2019.All patients were followed up for a 5-year survival period.The receiver operating characteristic curve was used to determine the optimal cut-off values for intravoxel incoherent motion quantitative parameters,including standard apparent diffusion coefficient(sADC),diffusion coefficient(D),pseudo-diffusion coefficient(D*)and perfusion fraction(F).Univariate and multivariate Cox regression analyses were performed to select independent predictive factors affecting the overall survival time of HCC patients after surgery.Results Univariate Cox regression analysis showed that pathological grading(HR=1.588,95%CI 0.936-2.692,P=0.086),microscopic vascular invasion(HR=2.512,95%CI 1.308-4.823,P=0.006),neutrophil-to-lymphocyte ratio(HR=1.752,95%CI 1.000-3.068,P=0.050),sADC(HR=0.433,95%CI 0.235-0.796,P=0.007),D(HR=0.262,95%CI 0.121-0.565,P<0.001)and F(HR=2.268,95%CI 1.259-4.087,P=0.006)were all prognostic factors.Multivariate Cox regression analysis showed that pathological grade(grade Ⅲ and Ⅳ)was the independent risk factor for the survival prognosis of patients after HCC surgery(HR=1.748,95%CI 1.003-3.045,P=0.049);the D value>0.916×10-3 mm2/s was the independent protective factor for their survival prognosis(HR=0.249,95%CI 0.113-0.550,P<0.001).Conclusion The pathological grade(Ⅲ/Ⅳ)as an independent risk factor and higher D values as a protective factor are the independent predictors of survival and prognosis of patients with HCC after surgery,and the combination of the two can provide a reference for clinical prognosis assessment.
5.Long-term efficacy analysis of narrow-margin hepatectomy intraoperative radiotherapy for hepatocellular carcinoma
Mengyuan LI ; Yanling WU ; Liming WANG ; Fan WU ; Shulian WANG ; Yueping LIU ; Yongwen SONG ; Ning LI ; Yuan TANG ; Hao JING ; Hui FANG ; Ningning LU ; Shunan QI ; Zhuanbo YANG ; Siye CHEN ; Yexiong LI ; Jianxiong WU ; Qinfu FENG ; Yirui ZHAI ; Bo CHEN
Cancer Research and Clinic 2025;37(5):343-350
Objective:To investigate the long-term efficacy, safety and prognostic factors of intraoperative radiotherapy (IORT) for narrow-margin (resection margin < 1 cm) hepatectomy in patients with hepatocellular carcinoma (HCC) during radical surgery.Methods:A retrospective cohort study was conducted. The data of primary HCC patients undergoing radical surgery and narrow-margin hepatectomy IORT in the Cancer Hospital of the Chinese Academy of Medical Sciences from November 2009 to February 2019 were collected. IORT applied 6 MeV or 9 MeV electron beams and a single irradiation was given to the margin. Kaplan-Meier method was used for the overall survival (OS) and disease-free survival (DFS) analysis; log-rank test was used for survival comparison among subgroups. The recurrence patterns and adverse reactions were recorded. Univariate and multivariate Cox proportional hazards models were used to analyze the factors influencing the OS and DFS.Results:A total of 64 patients were enrolled, with the median age [ M ( Q1, Q3)] of 57 years (49, 63) years. All patients included 55 males (85.9%) and 9 females (14.1%). The median dose of IORT was 15 Gy (range: 12-17 Gy). The median follow-up time was 83.3 (64.4, 91.9) months. The 1-year, 3-year, 5-year, 7-year, 10-year OS rates were 90.4%, 80.6%, 75.5%, 71.4% and 47.6%, respectively; the 1-year, 3-year, 5-year, 7-year,10-year DFS rates were 77.8%, 68.1%, 59.6%, 57.6% and 38.4%, respectively. Univariate Cox regression analysis indicated that preoperative serum alpha-fetoprotein (AFP) > 400 ng/ml was an independent risk factor for poor OS (> 400 ng/ml vs. ≤ 400 ng/ml: HR = 6.57, 95% CI: 2.16-19.96, P < 0.001), while not the independent influencing factor of poor DFS ( HR = 1.71, 95% CI: 0.65-4.52, P = 0.277). The age ≤ 60 years or not, gender, viral hepatitis or not, American Joint Committee on Cancer stage, tumor diameter (> 5 cm or not), tumor number, degree of tumor differentiation, microvascular invasion or not, microsatellite nodules or not, anatomical liver resection or not, and the dose of IORT ≤15 Gy or not were not the independent influencing factors of poor OS and DFS (all P > 0.05). Kaplan-Meier method analysis showed that patients with preoperative serum AFP ≤ 400 ng/ml (48 cases) had better OS compared with those with preoperative serum AFP>400 ng/ml (16 cases) (5-year OS rate: 84.8% vs. 44.9%; 7-year OS rate: 79.9% vs.37.4%), and the difference was statistically significant ( P = 0.002). There was no statistically significant difference in the DFS between the 2 groups ( P = 0.134). During the follow-up, 28 patients (43.8%) relapsed, including 17 cases (26.6%) of early recurrence and 11 cases (17.2%) of late recurrence. No marginal recurrence was observed. There were 22 cases (34.4%) of intrahepatic recurrence alone, 2 cases (3.1%) of extrahepatic recurrence and 4 cases (6.3%) of stimutaneous recurrence inside and outside the liver. The 1-, 3-, 5- and 7-year cumulative recurrence rates inside the liver were 19.0%, 27.2%, 37.4% and 39.3% respectively, and the cumulative recurrence rates outside the liver were 6.4%, 8.0%, 9.6% and 9.6% respectively. There were no adverse reactions above grade 3 in the entire group. There were no surgery-related deaths within 30 d after the operation, and no radiation-induced liver disease occurred. Conclusions:Narrow-margin IORT helps HCC patients receiving hepatectomy to achieve favorable long-term survival and adverse reactions are tolerable. It can be used as a safe and effective adjuvant therapy alternative.
6.Expert consensus on intraoperative repositioning for patients with spine fracture and dislocation (version 2025)
Dongmei BIAN ; Ke SUN ; Ningbo CHEN ; Caixia BAI ; Miao WANG ; Yafeng QIAO ; Fei WANG ; Hong WANG ; Feng TIAN ; Mei YAN ; Meng BAI ; Linjuan ZHANG ; Liyan ZHAO ; Yaqing CUI ; Xue JIANG ; Leling FENG ; Ning NING ; Junqin DING ; Lan WEI ; Yonghua ZHAI ; Yu ZENG ; Zengmei ZHANG ; Jiqun HE ; Fenggui BIE ; Hong CHEN ; Zengyan WANG ; Li LI ; Li ZHANG ; Yaying ZHOU ; Bing SHAO ; Ying WANG ; Caixia XIE ; Yanfeng YAO ; Jingjing AN ; Wen SHI ; Xiongtao LIU ; Xiaoyan AN ; Ning NAN ; Lan LI ; Xiaohui GOU ; Qiaomei LI ; Xiuting WU ; Yuqin ZHANG ; Jing LIU ; Fusen XIANG ; Xu XU ; Na MEI ; Jiao ZHOU ; Shan FAN ; Qian WANG ; Shuixia LI
Chinese Journal of Trauma 2025;41(2):138-147
Spine fracture and dislocation are common traumatic spinal conditions that often require surgical intervention due to compromised spinal stability. Surgical approaches include anterior, posterior, and combined anterior-posterior spinal procedures. According to the specific surgical requirements, patients may be placed in the prone position or repositioned between prone and supine positions during surgery. Intraoperative repositioning has become an essential step in patient positioning. However, during repositioning, patients with spinal fracture and dislocation are at increased risk for complications such as hemodynamic instability, nerve injury, and pressure injuries to the skin and soft tissue. Notably, due to the instability of the spinal cord, even minor manipulations can further exacerbate the damage, potentially leading to severe outcomes like paraplegia. Although the current clinical guidelines provide instructive recommendations for standard position, there remains no specific protocols for intraoperative repositioning in patients with spine fracture and dislocation. With a concern for the lack of clinical studies on positioning techniques, risk prevention, and operational norms for special patients, no applicable guidelines or standards are available. A consensus was required to provide clinical reference, meet the requirements of surgical treatment, and minimize the safety risks of patients caused by improper placement of positions. Professional Committee of Operating Room Nursing of Shaanxi Nursing Association organized experts in nursing management and operating room nursing from major hospitals across China to formulate Expert consensus on intraoperative repositioning for patients with spinal fracture and dislocation ( version 2025). The consensus provides 11 recommendations covering pre-repositioning preparation, intraoperative maneuvers, and post-repositioning observation, aiming to provide references for clinical standardization of the intraoperative repositioning process and protection of patients′ safety.
7.Role of Toll-like receptor 4 in regulation of homocysteine-induced ferroptosis in macrophages
Jun-jie ZHAI ; Shaoying WEN ; Xinru LI ; Rui SUN ; Ning QI ; Qifan ZHANG ; Li YANG ; Hui HUANG ; Lingju MA ; Yinju HAO ; Yideng JIANG ; Guizhong LI ; Shengchao MA
The Journal of Practical Medicine 2025;41(3):313-321
Objective To investigate the role of Toll-like receptor 4(TLR4)in the regulation of homocys-teine(Hcy)-induced ferroptosis in macrophages.Methods Mouse macrophage cells RAW264.7 were cultured and divided into control group,Hcy intervention group(Hcy group),and Hcy plus ferroptosis inhibitor group(Hcy+Fer-1 group).After transfection with interference fragments,macrophages were treated with Hcy,and then divided into control group,Hcy intervention group(Hcy group),TLR4 interference negative control plus Hcy intervention group(si-NC+Hcy group),and TLR4 interference plus Hcy intervention group(si-TLR4+Hcy group).Macrophages were transfected with overexpression lentivirus and treated with Hcy,then were divided into control group,Hcy intervention group(Hcy group),a TLR4 overexpression negative control plus Hcy intervention group(OE-NC+Hcy group),and a TLR4 overexpression plus Hcy intervention group(OE-TLR4+Hcy group).After 48 hours of intervention,real-time fluorescent quantitative PCR and western blot were used to detect the expression levels of TLR4 in macrophages treated with Hcy;western blot was used to detect the expression levels of ferroptosis-related proteins ACSL4,GPX4,and FTH1 in macrophages,and ferrous ion assay kit to detect the concentration of Fe2+in macrophages;reactive oxygen species(ROS)assay kit and laser confocal microscopy were used to detect the content of intracellular reactive oxygen species.Results Compared with those in the control group,the expression level of the pro-ferroptosis protein ACSL4 was increased in the Hcy group(P<0.05),while the expression levels of anti-ferroptosis proteins GPX4 and FTH1 were decreased(P<0.05);the concentration of Fe2+was increased(P<0.05),and the content of ROS was increased.Meanwhile,the protein and mRNA expres-sion levels of TLR4 were both increased in the Hcy group(P<0.05).After macrophages were transfected with TLR4 interference fragments,compared with those in the si-NC+Hcy group,the expression levels of GPX4 and FTH1 were increased(P<0.05);the expression level of ACSL4 was decreased(P<0.05);the concentration of Fe2+was decreased(P<0.05),and the content of ROS was reduced in the si-TLR4+Hcy group.After macro-phages were transfected with TLR4 overexpression lentivirus,compared with those in the OE-NC+Hcy group,the expression levels of GPX4 and FTH1 were decreased(P<0.05),and the expression level of ACSL4 was increased(P<0.05)in the OE-TLR4+Hcy group.Conclusion Hcy induces the occurrence of ferroptosis in macrophages,and Toll-like receptor 4 has a positive feedback regulatory effect on ferroptosis in macrophages.
8.Comparison of the effect of metal prefabricated crowns and 3M350 universal resin on the dental caries of deciduous teeth
Chaonan ZHAO ; Ning YAO ; Liyun ZHAI ; Yang XU ; Zhimin DING
Journal of Chinese Physician 2025;27(2):201-205
Objective:To compare the effect of metal prefabricated crowns and 3M350 universal resin on the dental caries of deciduous teeth.Methods:Retrospective analysis was performed on the clinical data of 89 children with proximal molar caries restoration admitted to Nantong Stomatological Hospital from January 2020 to January 2022. According to treatment methods, they were divided into observation group (metal prefabricated crowns restoration treatment, 49 cases of 49 teeth) and control group (3M350 universal resin restoration treatment, 40 cases of 40 teeth). The repair effect, occlusal function, periodontal index, treatment satisfaction and complications were compared.Results:The success rate of repair in the observation group (93.88%, 46/49) was higher than that in the control group (77.50%, 31/40), and the difference was statistically significant ( P<0.05). The maximum biting force and masticatory efficiency of the two groups after treatment were higher than those before treatment, and the observation group was higher than the control group, and the difference was statistically significant (all P<0.05). Comparison of periodontal indexes between the experimental and control groups comparison of probing depth (PD), plaque index (PLI), and bleeding index (BI) between the two groups before treatment, the differences were not statistically significant (all P>0.05); after treatment, PD, PLI, and BI were lower in both groups, and lower in the experimental group (all P<0.05). The total satisfaction of the observation group (87.76%, 43/49) was higher than that of the control group (65.00%, 26/40), and the difference was statistically significant ( P<0.05). The incidence of complications in the observation group (6.12%, 3/49) was lower than that in the control group (22.50%, 9/40), and the difference was statistically significant ( P<0.05). Conclusions:Compared with 3M350 general purpose resin, metal prefabricated crowns has better repairing effect and lower complication rate on adjacent caries of deciduous teeth, so it can be widely used in clinic.
9.Analysis of tear film stability and corneal nerve changes in patients with Parkinson's disease
Yujie* LI ; Cancan* SHI ; Haoyu ZHAI ; Xiaofan YU ; Xinke LI ; Ning MU ; Mingxin LI ; He WANG
International Eye Science 2025;25(2):206-212
AIM: To assess the stability of the tear film and the characteristics of corneal nerves in patients with Parkinson's disease(PD).METHODS: This cross-sectional observational study included 72 PD patients and 50 healthy controls. Disease severity was determined using the Hoehn-Yahr(H-Y)scale, dividing patients into mild and moderate PD groups. Dry eye symptoms were evaluated via the ocular surface disease index(OSDI)questionnaire, while tear secretion was quantified using the Schirmer I test. Ocular surface damage was assessed through staining scores, and comprehensive ocular examinations were performed utilizing the LipiView ocular surface interferometer and an ocular surface analyzer. Corneal nerve parameters were examined using corneal confocal microscopy in conjunction with automated analysis software ACCMetrics, with correlations drawn between these parameters, PD course, and severity.RESULTS: PD patients exhibited significantly elevated OSDI scores, indicative of more pronounced dry eye symptoms compared to the control group(F=70.290, P<0.01). Tear film stability was markedly compromised, with significantly shorter tear film breakup time and increased corneal fluorescein staining, both showing statistically significant differences relative to controls(all P<0.01). Tear secretion indices, including Schirmer I test results and tear meniscus height, were significantly reduced in PD patients(all P<0.01), whereas lipid secretion indices, such as lipid layer thickness and meibomian gland dropout score, did not show significant variation. Corneal nerve analysis revealed significant reductions in corneal nerve fiber density, nerve branch density, fiber length, and total branch density in PD patients compared to controls(all P<0.01). Furthermore, blink frequency was markedly prolonged(F=62.353, P<0.01). Correlation analysis demonstrated a significant relationship between alterations in tear film stability and both disease duration and H-Y scores.CONCLUSION: PD patients have obvious dry eye manifestations in the early stage of the disease, including the reduction of tear film stability and corneal nerve fiber density, and gradually aggravate with the progress of the disease. Neurodegenerative disease-related dry eye needs to be diagnosed early and actively treated.
10.Expert consensus on intraoperative repositioning for patients with spine fracture and dislocation (version 2025)
Dongmei BIAN ; Ke SUN ; Ningbo CHEN ; Caixia BAI ; Miao WANG ; Yafeng QIAO ; Fei WANG ; Hong WANG ; Feng TIAN ; Mei YAN ; Meng BAI ; Linjuan ZHANG ; Liyan ZHAO ; Yaqing CUI ; Xue JIANG ; Leling FENG ; Ning NING ; Junqin DING ; Lan WEI ; Yonghua ZHAI ; Yu ZENG ; Zengmei ZHANG ; Jiqun HE ; Fenggui BIE ; Hong CHEN ; Zengyan WANG ; Li LI ; Li ZHANG ; Yaying ZHOU ; Bing SHAO ; Ying WANG ; Caixia XIE ; Yanfeng YAO ; Jingjing AN ; Wen SHI ; Xiongtao LIU ; Xiaoyan AN ; Ning NAN ; Lan LI ; Xiaohui GOU ; Qiaomei LI ; Xiuting WU ; Yuqin ZHANG ; Jing LIU ; Fusen XIANG ; Xu XU ; Na MEI ; Jiao ZHOU ; Shan FAN ; Qian WANG ; Shuixia LI
Chinese Journal of Trauma 2025;41(2):138-147
Spine fracture and dislocation are common traumatic spinal conditions that often require surgical intervention due to compromised spinal stability. Surgical approaches include anterior, posterior, and combined anterior-posterior spinal procedures. According to the specific surgical requirements, patients may be placed in the prone position or repositioned between prone and supine positions during surgery. Intraoperative repositioning has become an essential step in patient positioning. However, during repositioning, patients with spinal fracture and dislocation are at increased risk for complications such as hemodynamic instability, nerve injury, and pressure injuries to the skin and soft tissue. Notably, due to the instability of the spinal cord, even minor manipulations can further exacerbate the damage, potentially leading to severe outcomes like paraplegia. Although the current clinical guidelines provide instructive recommendations for standard position, there remains no specific protocols for intraoperative repositioning in patients with spine fracture and dislocation. With a concern for the lack of clinical studies on positioning techniques, risk prevention, and operational norms for special patients, no applicable guidelines or standards are available. A consensus was required to provide clinical reference, meet the requirements of surgical treatment, and minimize the safety risks of patients caused by improper placement of positions. Professional Committee of Operating Room Nursing of Shaanxi Nursing Association organized experts in nursing management and operating room nursing from major hospitals across China to formulate Expert consensus on intraoperative repositioning for patients with spinal fracture and dislocation ( version 2025). The consensus provides 11 recommendations covering pre-repositioning preparation, intraoperative maneuvers, and post-repositioning observation, aiming to provide references for clinical standardization of the intraoperative repositioning process and protection of patients′ safety.

Result Analysis
Print
Save
E-mail